MBS1205 LAMBDA
Document overview
- PDF pages: 3
Technical content
Page 1

m Features
(1) For equipment designed to meet EMI regulations
such as VCCI, CISPR, FCC, VDE, etc.
(2) Attenuation effect against high voltage pulse
noise
(3) Attenuates conductive emission from power
supply
(4) Leakage current: 1mA max. (250V, 60Hz)
(5) High shielded effect
m Safety standard
UL1283, CSA Std. C22. 2 No. 8
VDE0565 Teil. 3
)
VDE0565 will transfer to EN133200
on and after July 23, 2003.
m Specifications
| Model Item | MBS-1205-22 | MBS-1210-22 | MBS-1215-22 | MBS-1220-22 | MBS-1230-22 | ||
| 1 | Rated voltage (AC, DC) | 250V | |||||
| 2 | Rated current (AC, DC) | 5A (Note 1) | 10A (Note 1) | 15A (Note 2) | 20A (Note 2) | 30A (Note 2) | |
| 3 | Test voltage (terminal to case, AC 1 minute) | 2500V | |||||
| 4 | Isolation resistance (terminal to case, 500VDC) | 100MΩmin. | |||||
| 5 | Leakage current | 125V, 60Hz | 0.5mA max. | ||||
| 250V, 60Hz | 1mA max. | ||||||
| 6 | DC resistance | 0.15Ωmax. | 0.05Ωmax. | 0.03Ωmax. | 0.02Ωmax. | 0.01Ωmax. | |
| 7 | Temperature rise | 30°C max. | 35°C max. | ||||
| 8 | Operating temperature range | –25 ~ +85°C | |||||
| 9 | Weight (typ) | 310g | 310g | 550g | 550g | 1,100g | |
<=
(Note 1) : Value at Ta 55°C. Refer to the derating curve (A) shown below at Ta > 55°C.
<=
(Note 2) : Value at Ta 50°C. Refer to the derating curve (B) shown below at Ta > 50°C.
m Derating
m Circuit

MBS-1205, -1210, -1215, -1220

R: Breeder resistance

MBS-1230

R: Breeder resistance
v Request customer specification for further details of specifications, outline, characteristics, etc. Read the instruction manual before usage. v Contact us about delivery before ordering.
Page 2
m MBS-1205-22

m MBS-1210-22
Case: Metal
(Unit: mm)
m MBS-1215-22

m MBS-1230-22

Page 3
CHARACTERISTICS
m Typical Insertion Loss
.............. Symmetrical ———— Asymmetrical




Frequency (MHz)