LW541C OSRAM

Document overview

  • Manufacturer or author: Provided By www.digicamel.com(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 14

Technical content

Features

 package: colorless, clear 5 mm (T1¾) package  feature of the device: narrow viewing angle, solder leads without stand-off  color coordinates: x = 0.32, y = 0.31 acc. to CIE 1931 (white)  typ. color temperature: 6500 K  color reproduction index: 80  viewing angle: 20°  technology: InGaN  optical efficiency: 20 lm/W  grouping parameter: Partial Flux, color coordinates  soldering methods: TTW soldering  packing: bulk, available taped on reel  ESD-withstand voltage: up to 2 kV acc. to JESD22-A114-D

Applications

 outdoor displays  optical indicators  signal and symbol luminaire  marker lights (e.g. steps, exit ways, etc.)  lighting for special effects (e.g. starry sky)  substitute for miniature flashlight  furniture lighting (e.g. glass cupboards)

Anm.: Da die Gruppierung der LEDs in Lux mit der innovativen Partial Flux-Methode erfolgt, wurden Vergleichsmessungen an Bauteilen jeweils mit dem "Partial Flux"-Testkopf und dem "Standard LED"-Testkopf (gemäß CIE-127-B) durchgeführt. Der Vergleich soll als Orientierung dienen, er stellt keine eins-zu-eins-Korrelati on dar. Ziel dieses Vergleichs ist ein besseres Verständnis des Lichtflusses in [lux] in Relation zu den Lichtstärkewerten in [cd]. Das Verhältnis von typischen Werten, die mit dem "Partial Flux" gemessen werden, zu denen, die mit dem Standard-Messkopf gemessen werden, ist [lux] x 1.4 =[mcd]. Die oben genannten Typbezeichnungen umfassen die beste llbaren Selektionen. Diese bestehen aus wenigen Helligkeitsgruppen (siehe Seite 6 für nähere Informationen). Es wird nur eine einzige Helligkeitsgruppe pro Gurt geliefert. Z.B.: LW 541C-AWBW-6K9L bedeutet, dass auf dem Gurt nur eine der Helligkeitsgruppen AW oder BW enthalten ist. Um die Liefersicherheit zu gewährleisten, können einzelne Helligkeitsgruppen nicht bestellt werden. Gleiches gilt für die Farben, bei denen Farbortgruppen gemessen und gruppiert werden. Pro Gurt wird nur eine Farbortgruppe geliefert. Z.B.: LW 541C-AWBW-6K9L bedeutet, dass auf dem Gurt nur eine der Farbortgruppen -6K, -6L, -7K, -7L, -8K, -8L, -9K oder -9L enthalten ist (siehe Seite 5 für nähere Information). Um die Liefersicherheit zu gewährleisten, können einzelne Farbortgruppen nicht bestellt werden. Note: As the innovative partial flux method is applied to the grouping of LEDs in lux, some measurements were made in order to compare the results of the “Partial Flux” testhead to the “standard LED” testhead (in compliance with CIE-127-B). The comparison should be used for a better understanding of partial flux in [lux] in relation to the values stated in luminous intensity [cd]. It should not be taken as a one-to-one correlation. The ratio of typi cal values measured with the “Partial Flux” testhead and the normal LED testhead is [lux] x 1.4 =[mcd]. The above Type Numbers represent the order groups which include only a few brightness groups (see page 6 for explanation). Only one group will be shipped on each reel (t here will be no mixing of two groups on each reel). E.g. LW 541C-AWBW-6K9L means that only one group AW or BW shippable for any one reel. In order to ensure availability, single brightness groups will not be orderable. In a similar manner for colors where chromaticity coor dinate groups are measured and binned, single chromaticity coordinate groups will be sh ipped on any one reel. E.g. LW 541C-AWCW-6K9L means that only 1 chromaticity coordinate group -6K, -6L, -7K, -7L, -8K, -8L, -9K or -9L will be shippable (see page 5 for explanation). In order to ensure availability, single chromaticity coordinate groups will not be orderable. Bestellinformation

Ordering Information

Gehäuse- farbe Color of Package Partieller Lichtfluss Seite 14 Partial Flux1) page 14 IF = 20 mA EV [lux] Lichtstrom2) Seite 14 Luminous Flux 2) page 14 IF = 20 mA ΦV (mlm) Bestellnummer Ordering Code !LW 541C-AWBW-6K9L !LW 541C-BWDW-6K9L !LW 541C-AWDW-6K9L white colorless clear 1120 ...2800 1800 ...7100 1120 ...7100 820 (typ.) 1870 (typ.) 1725 (typ.) Q65110A3605 Q65110A3606 Q65110A2887 !Abgekündigt nach OS-PD-2008-008 - wird nicht ersetzt werden Obsolete acc. to OS-PD-2008-008 - no replacement Letzte Bestellung / Last Order: 2009-01-10 Letzte Lieferung / Last Delivery: 2009-07-10

Operating temperature range Top – 40 … + 100 °C Lagertemperatur Storage temperature range Tstg – 40 … + 100 °C Sperrschichttemperatur Junction temperature Tj + 100 °C Durchlassstrom Forward current (TA=25°C) IF 20 mA Stoßstrom Surge current t ≤ 10 μs, D = 0.005, TA=25°C IFM 200 mA Sperrspannung3) Seite 14 Reverse voltage3) page 14 (TA=25°C) VR 5 V Leistungsaufnahme Power consumption (TA=25°C) Ptot 85 mW Wärmewiderstand4) Seite 14 Thermal resistance4) page 14 Sperrschicht/Umgebung5) Seite 14 Junction/ambient5) page 14 Sperrschicht/Lötpad Junction/solder point Rth JA Rth JS 450 230 K/W K/W

(TA = 25 °C) Bezeichnung Parameter Symbol Symbol Wert Value Einheit Unit Farbkoordinate x nach CIE 19316) Seite 14 Chromaticity coordinate x acc. to CIE 19316) page 14 IF = 20 mA x 0.32 – Farbkoordinate y nach CIE 19316) Seite 14 Chromaticity coordinate y acc. to CIE 19316) page 14 IF = 20 mA y 0.31 – Abstrahlwinkel bei 50 % IV (Vollwinkel) Viewing angle at 50 % IV 2ϕ 20 Grad deg. Durchlassspannung7) Seite 14 (min.) Forward voltage7) page 14 (typ.) IF = 20 mA (max.) VF VF VF 3.0 3.6 4.1 V V V Sperrstrom (typ.) Reverse current (max.) VR = 5 V IR IR 0.01 μA μA Temperaturkoeffizient von x Temperature coefficient of x IF = 20 mA; –10°C ≤ T ≤ 100°C TCX –0.1 10-3/K Temperaturkoeffizient von y Temperature coefficient of y IF = 20 mA; –10°C ≤ T ≤ 100°C TCY –0.2 10-3/K Temperaturkoeffizient von VF Temperature coefficient of VF ) IF = 20 mA; –10°C ≤ T ≤ 100°C TCV –5.0 mV/K Optischer Wirkungsgrad (typ.) Optical efficiency IF = 20 mA ηopt 20 lm/W

Farbortgruppen5) Seite 14 Chromaticity Coordinate Groups5) page 14 Gruppe Group Cx Cy Gruppe Group Cx Cy 6K 0.313 0.284 8K 0.352 0.344 0.310 0.297 0.338 0.342 0.330 0.330 0.364 0.380 0.330 0.310 0.360 0.357 6L 0.310 0.297 8L 0.345 0.352 0.307 0.312 0.347 0.371 0.330 0.347 0.367 0.401 0.330 0.330 0.364 0.380 7K 0.330 0.310 9K 0.360 0.357 0.330 0.330 0.364 0.380 0.338 0.342 0.375 0.395 0.352 0.344 0.370 0.370 7L 0.330 0.330 9L 0.364 0.380 0.330 0.347 0.367 0.401 0.347 0.371 0.379 0.420 0.345 0.352 0.375 0.395 OHA15327 520 530 540 550 560 570 580 590 600 610 620 630 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 510 500 490 480 470 450 460 0.29 0.25 Cy Cx Cx Cy 0.39 0.27 0.29 0.31 0.33 0.35 0.37 0.39 0.41 0.43 0.45 0.30 0.31 0.32 0.33 0.34 0.35 0.36 0.37 0.38 0.26 0.30 0.28 0.34 0.32 0.44 0.38 0.36 0.42 0.40

Helligkeits-Gruppierungsschema Brightness Groups Helligkeitsgruppe Brightness Group Partieller Lichtfluss1)Seite 14 Partial Flux1) page 14 EV [lux] Lichtstärke2) Seite 14 Luminous Intensity2)page 14 IV (mcd) Lichtstrom2) Seite 14 Luminous Flux2) page 14 ΦV (mlm) AW BW CW DW 1120 ... 1800 1800 ... 2800 2800 ... 4500 4500 ... 7100 2050 (typ.) 3220 (typ.) 5100 (typ.) 8120 (typ.) 610 (typ.) 970 (typ.) 1530 (typ.) 2450 (typ.) Anm.: Die Standardlieferform von Serientypen beinha ltet entweder eine untere Familiengruppe, eine obere Familiengruppe oder eine Sammelgruppe, die aus nur 2, 3 bzw. 4 Helligkeitsgruppen bestehen. Einzelne Helligkeitsgruppen sind nicht bestellbar. Note: The standard shipping format for serial types includes either a lower family group, an upper family group or a grouping of all individual groups of 2, 3 or 4 brightness groups. Individual brightness groups cannot be ordered. Gruppenbezeichnung auf Etikett Group Name on Label Beispiel: BW-8L Example: BW-8L Helligkeitsgruppe Brightness Group Farbortgruppe Chromaticity Coordinate Group BW 8L Anm.: In einer Verpackungseinheit / Gurt ist immer nur eine Gruppe für jede Selektion enthalten. Note: No packing unit / tape ever contains more than one group for each selection.

Prinzipieller Messaufbau für Partial Flux Messung Schematic test method for partial flux measurement d OHAY0908 = 40˚θ Referenzebene des Detektors (ø14 mm) Reference layer of detector (ø14 mm)

Relative spektrale Emission2) Seite 14 Relative Spectral Emission2) page 14 V(λ) = spektrale Augenempfindlichkeit / Standard eye response curve Irel = f (λ); TA = 25 °C; IF = 20 mA Abstrahlcharakteristik2) Seite 14 Radiation Characteristic2) page 14 Irel = f (ϕ); TA = 25 °C 400 λ OHL01461 I 100 rel nm Vλ 450 500 550 600 650 700 750 OHL00209 100˚ 90˚ 80˚ 70˚ 60˚ 50˚ 0.2 0.4 0.6 0.8 1.0 ϕ

Durchlassstrom2) Seite 14 Forward Current2) page 14 IF = f (VF); TA = 25 °C Farbortverschiebung2) Seite 14 Chromaticity Coordinate Shift2) page 14 x, y = f (IF); TA = 25 °C Relative Lichtstärke2) 8) Seite 14 Relative Luminous Intensity2) 8) page 14 IV/IV(20 mA) = f (IF); TA = 25 °C Relative Lichtstärke2) Seite 14 Relative Luminous Intensity2) page 14 IV/IV(25 °C) = f (Tj); IF = 20 mA OHL11462 2.0 IF VF 10-1 100 mA OHL00655 0.30401 0 2 0 30 x, y 50mA 0.306 0.308 0.310 0.312 0.314 0.316 0.318 0.324 x y FI OHL01518 100 -110 51 0 1 100 V (20 mA)I IV 101 mA IF 102 OHL02870 -60 T V (25 ˚C)I IV -40 -20 0 20 40 60 100 0.2 0.4 0.6 0.8 1.0 1.2 1.4 j

Maximal zulässiger Durchlassstrom Max. Permissible Forward Current IF = f (TA) Zulässige Impulsbelastbarkeit IF = f (tp) Permissible Pulse Handling Capability Duty cycle D = parameter, TA= 25 °C Zulässige Impulsbelastbarkeit IF = f (tp) Permissible Pulse Handling Capability Duty cycle D = parameter, TA= 85 °C temp. solder point 40200 T S 1008060 ˚C T IF mA OHL10179 temp. ambientTA TA TS OHL02004 10-5 pt FI 10-4 10-3 10-2 10-1 100 1010 A 210s D tP T Pt IF 0.01 0.05 0.2 0.1 0.005 0.02 0.5 D = 0.05 0.10 0.15 0.20 0.25 0.35 OHL02005 10-5 pt FI 10-4 10-3 10-2 10-1 100 1010 A 210s D tP T Pt IF 0.01 0.05 0.2 0.1 0.005 0.02 0.5 D = 0.05 0.10 0.15 0.20 0.25 0.35

Maßzeichnung9) Seite 14 Package Outlines9) page 14 Kathodenkennung: kürzerer Lötspieß Cathode mark: short solder lead Gewicht / Approx. weight: 0.35 g Empfohlenes Lötpaddesign9) Seite 14 Wellenlöten (TTW) Recommended Solder Pad9) page 14 TTW Soldering 0.4 (0.016) 0.6 (0.024) 5.5 (0.217) 5.9 (0.232) Area not flat 8.2 (0.323) 9.0 (0.354) ø4.8 (0.189) ø5.1 (0.201) 7.8 (0.307) 7.5 (0.295) 27.0 (1.063) 29.0 (1.142) spacing 2.54 (0.100) 0.8 (0.031) 0.4 (0.016) 0.4 (0.016) 0.6 (0.024) 1.2 (0.047) 1.8 (0.071) Cathode GEXY6713 4 (0.157) OHLPY985 4.8 (0.189)

Lötbedingungen Soldering Conditions Wellenlöten (TTW) ( nach CECC 00802) TTW Soldering ( acc. to CECC 00802) OHLY0598 50 100 150 200 250 100 150 200 250 300 T t C s 235 C 10 s C... 260 1. Welle 1. wave 2. Welle 2. wave

5 K/s 2 K/sca 200 K/s

CC... 130100

2 K/s

Zwangskühlung forced cooling Normalkurve standard curve Grenzkurven limit curves

Attention please! The information describes the type of component and shall not be considered as assured characteristics. Terms of delivery and rights to change design reserv ed. Due to technical requirements components may contain dangerous substances. For information on the types in question please contact our Sales Organization. If printed or downloaded, please find the latest version in the Internet. Packing Please use the recycling operators known to you. We can also help you – get in touch with your nearest sales office. By agreement we will take packing material back, if it is sorted. You must bear the costs of tr ansport. For packing material that is returned to us unsorted or which we are not obliged to accept, we shall have to invoice you for any costs incurred. Components used in life-support devices or system s must be expressly authorized for such purpose! Critical components10) page 14 may only be used in life-support devices or systems 11) page 14 with the express written approval of OSRAM OS. Revision History: 2008-07-07 Previous Version: 2007-08-10 Page Subjects (changes since last revision) Date of change 1, 4 correct calculation of optical efficiency 2005-11-19 all Product Discontinuation OS-PD-2008-008 2008-07-07 Patent List Patent No. US 6 066 861 US 6 277 301 US 6 245 259 US 6 576 930

Fußnoten: 1) Helligkeitswerte werden mit einer Stromeinprägedauer von 25 ms und einer Genauigkeit von ± 11% ermittelt. 2) Wegen der besonderen Prozessbedingungen bei der Herstellung von LED können typische oder abgeleitete technische Parameter nur aufgrund statistischer Werte wiedergegeben werden. Diese stimmen nicht notwendigerweise mit den Werten jedes einzelnen Produktes überein, dessen Werte sich von typischen und abgeleiteten Werten oder typischen Kennlinien unterscheiden können. Falls erforderlich, z.B. aufgrund technischer Verbesserungen, werden diese typischen Werte ohne weitere Ankündigung geändert. 3) Die LED kann kurzzeitig in Sperrichtung betrieben werden. 4) Rth erhöht sich um 13 K/W pro mm Beinchenlänge. Minimale Beinchenlänge, Entfernung vom Verguss ist 0 mm. 5) RthJA ergibt sich bei Montage auf PC-Board FR 4 (Padgröße ≥ 16 mm2 je Pad) Minimale Beinchenlänge, Entfernung vom Verguss ist 0 mm. 6) Farbortgruppen werden mit einer Stromeinprägedauer von 25 ms und einer Genauigkeit von ±0,01 ermittelt. 7) Durchlassspannungen werden mit einer Stromeinprägedauer von 1 ms und einer Genauigkeit von ±0,1 V ermittelt. 8) Im gestrichelten Bereich der Kennlinien muss mit erhöhten Helligkeitsunterschieden zwischen Leuchtdioden innerhalb ei ner Verpackungseinheit gerechnet werden. Dimmverhältnis im Gleichstrom-Betrieb max. 5:1 9) Maße werden wie folgt angegeben: mm (inch) 10) Ein kritisches Bauteil ist ein Bauteil, das in lebenserhaltenden Apparaten oder Systemen eingesetzt wird und dessen Defekt voraussichtlich zu einer Fehlfunktion dieses lebenserhaltenden Apparates oder Systems führen wird oder die Sicherheit oder Effektivit ät dieses Apparates oder Systems beeinträchtigt. 11) Lebenserhaltende Apparate oder Systeme sind für (a) die Implantierung in den menschlichen Körper oder (b) für die Lebenserhaltung bestimmt. Falls sie versagen, kann davon ausgegangen werden, dass die Gesundheit und das Leben des Patienten in Gefahr ist. Published by OSRAM Opto Semiconductors GmbH Wernerwerkstrasse 2, D-93049 Regensburg www.osram-os.com © All Rights Reserved. Remarks: 1) Brightness groups are test ed at a current pulse duration of 25 ms and a tolerance of ± 11%. 2) Due to the special conditions of the manufacturing processes of LED, the ty pical data or calculated correlations of technical pa rameters can only reflect statistical figures. These do not necessarily correspond to the actual parameters of each single product, which could differ from the typical data and calculated correlations or the typical characteristic line. If requested, e.g. because of technical improvements, these typ. data will be changed without any further notice. 3) Driving the LED in reverse direction is suitable for short term application. 4) Each additional 1 mm of lead length increases R th by 13 K/W. Minimum lead length, distance from resin 0 mm 5) RthJA results from mounting on PC board FR 4 (pad size ≥ 16 mm2 per pad) Minimum lead length, distance from resin 0 mm 6) Chromaticity coordinate groups are tested at a current pulse duration of 25 ms and a tolerance of ±0.01. 7) Forward voltage are tested at a current pulse duration of 1 ms and a tolerance of ±0.1 V. 8) In the range where the line of the graph is broken, you must expect higher bright ness differences between single LEDs within one packing unit. Dimming range for direct current mode max. 5:1 9) Dimensions are specified as follows: mm (inch). 10) A critical component is a component used in a life-support device or system whose failure can reasonably be expected to cause the failure of that life-support device or system, or to affect its safety or the effectiveness of that device or system. 11) Life support devices or systems are intended (a) to be implanted in the human body, or (b) to support and/or maintain and sustain human life. If they fail, it is reasonable to assume that the health and the life of the user may be endangered.