LSN2A MURATA

Document overview

  • Manufacturer or author: Provided By www.digicamel.com(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 15

Technical content

www.murata-ps.com/rohs www.murata-ps.com www.murata-ps.com Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000 LSN2 Series Non-isolated, DOSA-SIP , 6/10/16A Selectable-Output DC/DC Converters MDC_LSN2.B06 Page 1 of 15 ORDERING GUIDE SUMMARY Model V OUT Range I OUT Range V IN Range Ripple/Noise Effi ciency LSN2-T/6-W3 0.75-3.3V 0-6A 2.4-5.5V 15mVp-p 94% LSN2-T/6-D12 0.75-5V 0-6A 8.3-14V 15mVp-p 93% LSN2-T/10-W3 0.75-3.3V 0-10A 2.4-5.5V 15mVp-p 95% LSN2-T/10-D12 0.75-5V 0-10A 8.3-14V 30mVp-p 95% LSN2-T/16-W3 0.75-3.3V 0-16A 2.4-5.5V 25mVp-p 95% LSN2-T/16-D12 0.75-5V 0-16A 8.3-14V 30mVp-p 94% MECHANICAL CHARACTERISTICS INPUT CHARACTERISTICS Parameter Typ. @ 25°C, full load Notes Voltage Range 2.4-5.5 or 8.3-14V 5V or 12V nominal models Current, full power 4.22 to 11.12A Model dependent Undervoltage Shutdown Included With autorestart hysteresis Short Circuit Current 60mA Output is short circuited Remote On/Off Control Positive or negative polarity Default polarity is positive OUTPUT CHARACTERISTICS Parameter Typ. @ 25°C, full load Notes Voltage 0.75-3.3 or 0.75-5V User adjustable, model dependent Current 0-6, 0-10 or 0-16A Three ranges, model dependent Power Dissipation 20, 33, 52W max. Three values, model dependent Accuracy ±2% of V NOM 50% load Ripple & Noise 15-75mVpp Model dependent Line and Load Regulation ±0.03% Overcurrent Protection Hiccup autorecovery Continuous short circuit protection Overtemperature Protection +115°C shutdown Effi ciency (minimum) 92-93% Model dependent Effi ciency (typical) 94-95% Model dependent GENERAL SPECIFICATIONS Parameter Typ. @ 25°C, full load Notes Transient Response 25μsec 50% load step to 2% of fi nal value Operating Temperature Range –40 to +85°C With 200 lfm airfl ow Safety (designed to meet) UL/IEC/EN 60950-1 And CSA C22.2-No.234 EMI (designed to meet) FCC pt.15, class B May need external fi lter Pb Lead-free construction/attach

FEATURES

■ User-selectable outputs: 0.75-5V (D12 models) or 0.75-3.3V (W3 models) ■ 6, 10 or 16A maximum output current ■ Double lead free to RoHS standards ■ Selectable phased start-up sequencing and tracking ■ Wide range VIN 8.3-14V or 2.4-5.5V ■ Up to 52 Watts total output power ■ Very high effi ciency up to 95% ■ Starts up into pre-biased load ■ Fast settling, high di/dt IOUT slew rate PRODUCT OVERVIEW These miniature point-of-load (POL) switching DC/DC converters are ideal regulation and supply elements for distributed power and intermedi- ate bus architectures. Fully compatible with the Distributed-power Open Standards Alliance specifi cation (www.dosapower.com), LSN2’s can power CPU’s, programmable logic and mixed- voltage systems with little heat and low noise. A typical application uses a master isolated 12 or 5Vdc supply and individual LSN2 converters for local 1.8 and 3.3Vdc supplies. All system isolation resides in the central supply, leaving lower cost POL regulation at the load. The LSN2’s can deliver very high power (to 52 Watts) in a tiny area with- out heat sinking or external components. They feature quick transient response (to 25μsec) and very fast current slew rates (to 20A/μsec). Typical Unit Ḥ

Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000www.murata-ps.com LSN2 Series Non-isolated, DOSA-SIP , 6/10/16A Selectable-Output DC/DC Converters MDC_LSN2.B06 Page 2 of 15 PERFORMANCE SPECIFICATIONS AND ORDERING GUIDE /g99 Root Model /g105 Output Input Effi ciency Package (Case/ Pinout) VOUT (Volts) IOUT (Amps) Power (Watts) R/N (mVp-p) /g100 Regulation /g101VIN Nom. (Volts) Range /g103 (Volts) IIN /g102 (mA/A)Typ. Max. Line Load Min. Typ. LSN2-T/30-D12 0.8-5 30 150 Please refer to the separate LSN2-T/30 data sheet. ➀ Typical at TA = +25°C under nominal line voltage and full-load conditions, unless noted. All models are tested and specifi ed with external 22μF tantalum input and output capacitors. These capacitors are necessary to accommodate our test equipment and may not be required to achieve specifi ed performance in your applications. See I/O Filtering and Noise Reduction. “Nominal” output is 3.3V (W3 models) or 5V (D12 models) ➁ Ripple/Noise (R/N) is tested/specifi ed over a 20MHz bandwidth and may be reduced with external fi ltering. See I/O Filtering and Noise Reduction for details. ➂ These devices have no minimum-load requirements and will regulate under no-load conditions. Regula- tion specifi cations describe the output-voltage deviation as the line voltage or load is varied from its nominal/midpoint value to either extreme. ➃ Nominal line voltage, no-load/full-load conditions. ➄ V IN must be /g1160.5V greater than VOUT. ➅ LSN2-TXX-D12 effi ciencies are shown at 5VOUT. ➆ These are not complete model numbers. Please refer to the Part Number Structure when ordering. PART NUMBER STRUCTURE Maximum Rated Output: Current in Amps Non-Isolated Through-hole Output Confi guration: L = Unipolar Low Voltage Nominal Output Voltage: 0.75-3.3 Volts (W3) 0.75-5 Volts (D12) L SN2 - / D12-T 16 N G Input Voltage Range: D12 = 8.3-14 Volts (12V nominal) W3 = 2.4-5.5 Volts (5V nominal) On/Off Polarity: Blank = Positive polarity N = Negative polarity Power Good Output: Blank = Omitted G = Installed ➂ These devices have no minimum-load requirements and will regu- late under no-load conditions. Regulation specifi cations describe the output-voltage deviation as the line voltage or load is varied from its nominal/midpoint value to either extreme. ➃ Nominal line voltage, no-load/full-load conditions. ➄ V IN must be /g1160.5V greater than VOUT. ➅ LSN2-TXX-D12 effi ciencies are shown at 5VOUT. ➆ These are not complete model numbers. Please refer to the Part Number Structure when ordering. Note: Some model number combinations may not be available. Contact Murata Power Solutions for further information. C RoHS-6 hazardous substance compliant

Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000www.murata-ps.com LSN2 Series Non-isolated, DOSA-SIP , 6/10/16A Selectable-Output DC/DC Converters MDC_LSN2.B06 Page 3 of 15 Performance/Functional Specifi cations(1) Current Limit Inception: (98% of VOUT) LSN2-T/6 models 11-13 Amps (cold startup)

11 Amps (after warm up)

LSN2-T/10 models 18.75 Amps (cold startup)

16.75 Amps (after warm up)

LSN2-T/16 models 24 Amps (cold startup)

21 Amps (after warm up)

Short Circuit Mode (6) Short Circuit Current Output 600mA Protection Method (17) Hiccup autorecovery on overload removal Short Circuit Duration Continuous, no damage (output shorted to ground) Prebias Startup (16) Converter will start up if the external output voltage is less than V NOM Sequencing Slew Rate 2V max. per millisecond Startup delay until sequence start 10 milliseconds Tracking accuracy, rising input V OUT = ±100mV of Sequence In Tracking accuracy, falling input V OUT = ±200mV of Sequence In Sequence pin input impedance 400k /g58 to 1M/g58 Remote Sense to VOUT 0.5V max. (7) Power Good Output (14) TRUE (OK) = open drain (“G” suffi x) FALSE (not OK) = Signal Ground to 0.4V Power_Good Confi guration MOSFET to ground with external user pullup, 10mA max. sink DYNAMIC CHARACTERISTICS Dynamic Load Response 25μsec to ±2% of fi nal value (50-100-50% load step, di/dt = 20A/msec) Start-Up Time 4-7msec for V OUT = nominal (V IN on to VOUT regulated or On/Off to VOUT) Switching Frequency LSN2-T/6 models 315kHz LSN2-T/10 and -T/16 models 230kHz ENVIRONMENTAL Calculated MTBF (4) TBC Hours Operating Temperature Range (Ambient) No derating, natural convection –40 to +63°C, vertical mount, 2.5V OUT (9) With derating See Derating Curves Operating PC Board Temperature –40 to +100°C max. (12) Storage Temperature Range –55 to +125°C Thermal Protection/Shutdown +115°C Relative Humidity To +85% / +85°C PHYSICAL Outline Dimensions See Mechanical Specifi cations Removable Heat Shield Nylon 46 Pin Material Tin-plated copper alloy Weight 0.28 ounces (7.8 grams) Electromagnetic Interference FCC part 15, class B, EN55022 (conducted and radiated) (may need external fi lter) Safety UL/cUL 60950-1, CSA-C22.2 No.234 IEC/EN 60950-1 Flammability Rating UL94V-0 INPUT Input Voltage Range See Ordering Guide Isolation Not isolated, input and output commons are internally connected Start-Up Threshold W3 Models 2.2 Volts 12V Models 8 Volts Undervoltage Shutdown W3 Models 2.0 Volts 12V Models 7.5 Volts Overvoltage Shutdown None Refl ected (Back) Ripple Current (2) 10-70mAp-p (model dependent) Internal Input Filter Type Capacitive Reverse Polarity Protection See fuse information Input Current: Full Load Conditions See Ordering Guide Inrush Transient 0.1A 2sec Shutdown Mode (Off, UV, OT) 5mA Output Short Circuit 60mA No Load W3 models 50mA 12V models 100mA Low Line (V IN = VMIN) LSN2-T/6-W3 5.54 Amps LSN2-T/6-D12 3.85 Amps LSN2-T/10-W3 9.14 Amps LSN2-T/10-D12 6.31 Amps LSN2-T/16-W3 14.63 Amps LSN2-T/16-D12 10.2 Amps Remote On/Off Control: (5) Positive Logic (no model suffi x) OFF = ground pin to +0.8V max. ON = open pin or +2.5V min. to +V IN max. Negative Logic (“N” model suffi x) ON = open pin to +0.3V max. OFF = +2.5V min. to +V IN max. Current 1mA max. OUTPUT Voltage Output Range See Ordering Guide Minimum Loading No minimum load Accuracy (50% load) ±2% of V NOM Voltage Adjustment Range (13) See Ordering Guide Temperature Coeffi cient ±0.02% of V OUT range per °C Ripple/Noise (20 MHz bandwidth) See Ordering Guide and (8) Line/Load Regulation (See Tech Notes) See Ordering Guide and (10) Effi ciency See Ordering Guide Maximum Capacitive Loading: (15) LSN2-T/6 models: Cap-ESR = 0.001 to 0.01 /g58 3000μF Cap-ESR >0.01 /g58 5000μF LSN2-T/10 and -T/16 models: Cap-ESR = 0.001 to 0.01 /g58 5000μF Cap-ESR >0.01 /g58 10,000μF

Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000www.murata-ps.com LSN2 Series Non-isolated, DOSA-SIP , 6/10/16A Selectable-Output DC/DC Converters MDC_LSN2.B06 Page 4 of 15 (1) All models are tested and specifi ed with external 1 || 10μF ceramic/tantalum output capacitors and a 22μF external input capacitor. All capacitors are low ESR types. These capacitors are necessary to accommodate our test equipment and may not be required to achieve specifi ed performance in your applications. All models are stable and regulate within spec under no-load conditions. General conditions for Specifi cations are +25°C, V IN = nominal, VOUT = nominal, full load. “Nominal” output voltage is +5V for D12 models and +3.3V for W3 models. (2) Input Back Ripple Current is tested and specifi ed over a 5-20MHz bandwidth. Input fi ltering is CIN = 2 x 100μF tantalum, CBUS = 1000μF electrolytic, LBUS = 1μH. (3) Note that Maximum Power Derating curves indicate an average current at nominal input voltage. At higher temperatures and/or lower airfl ow, the DC/DC converter will tolerate brief full current outputs if the total RMS current over time does not exceed the derating curve. (4) Mean Time Before Failure is calculated using the Telcordia (Belcore) SR-332 Method 1, Case 3, ground fi xed conditions, TPCBOARD = +25°C, full output load, natural air convection. (5) The On/Off Control may be driven with external logic or by applying appropriate external voltages which are referenced to –Input Common. The On/Off Control Input should use either an open collector/open drain transistor or logic gate which does not exceed +VIN. A 68K/g58 external pullup resistor to +VIN will cause the “ON” state for negative logic models. (6) Short circuit shutdown begins when the output voltage under increasing load degrades approxi- mately 2% from the selected setting. (7) If Sense is connected remotely at the load, up to 0.5 Volts difference is allowed between the Sense and +VOUT pins to compensate for ohmic voltage drop in the power lines. A larger voltage drop may cause the converter to exceed maximum power dissipation. (8) Output noise may be further reduced by adding an external fi lter. See I/O Filtering and Noise Reduction. (9) All models are fully operational and meet published specifi cations, including “cold start” at –40°C. VOUT is nominal. (10) Regulation specifi cations describe the deviation as the line input voltage or output load current is varied from a nominal midpoint value to either extreme. (11) Other input or output voltage ranges are available under scheduled quantity special order. (12) Maximum PC board temperature is measured with the sensor in the center. (13) Do not exceed maximum power specifi cations when adjusting the output trim. (14) When Sequencing is not used, the Power Good output is TRUE at any time the output is within approximately ±10% of the voltage set point. Power Good basically indicates if the converter is in regulation. Power Good detects Over Temperature if the PWM has shut down due to OT. Power Good does not directly detect Over Current. If Sequencing is in progress, Power Good will falsely indicate TRUE (valid) before the output reaches its setpoint. Ignore Power Good if Sequencing is in transition. (15) The maximum output capacitive loads depend on the the Equivalent Series Resistance (ESR) of the external output capacitor. (16) Do not use Pre-bias startup and sequencing together. See Technical Notes below. (17) After short circuit shutdown, if the load is partially removed such that the load still exceeds the overcurrent (OC) detection, the converter will remain in hiccup restart mode. (18) For best noise performance, leave the Track/Sequence pin OPEN when not used. PERFORMANCE/FUNCTIONAL SPECIFICATION NOTES ABSOLUTE MAXIMUM RATINGS Input Voltage (Continuous or transient) W3 models +7 Volts 12V models +15 Volts On/Off Control –0.3V min. to +V IN max. Input Reverse Polarity Protection See Fuse section Output Current (7) Current-limited. Devices can withstand sustained short circuit without damage. Storage Temperature –55 to +125°C Lead Temperature See soldering guidelines These are stress ratings. Exposure of devices to greater than any of these conditions may adversely affect long-term reliability. Proper operation under conditions other than those listed in the Performance/Functional Specifi cations Table is not implied. Soldering Guidelines Murata Power Solutions recommends the specifi cations below when installing these converters. These specifi cations vary depending on the solder type. Exceeding these specifi cations may cause damage to the product. Be cautious when there is high atmo- spheric humidity. We strongly recommend a mild pre-bake (100° C. for 30 minutes). Your production environment may differ; therefore please thoroughly review these guidelines with your process engineers. Wave Solder Operations for through-hole mounted products (THMT) For Sn/Ag/Cu based solders: Maximum Preheat Temperature 115° C. Maximum Pot Temperature 270° C. Maximum Solder Dwell Time 7 seconds For Sn/Pb based solders: Maximum Preheat Temperature 105° C. Maximum Pot Temperature 250° C. Maximum Solder Dwell Time 6 seconds

Figure 1. LSN2 Series Simplifi ed Schematic ceramic/tantalum output capacitors and a 22μF tantalum input capacitor. put capacitors are specifi ed for low ESR and full-range frequency response. fi ltering techniques, the simplest being the installation of external I/O caps. (at appropriate frequencies), low ESR, and high rms-ripple-current ratings. confi guration may necessitate additional considerations.

Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000www.murata-ps.com LSN2 Series Non-isolated, DOSA-SIP , 6/10/16A Selectable-Output DC/DC Converters MDC_LSN2.B06 Page 8 of 15 never absolutely constant, the converter may start up at some times and not at others. Solutions To improve start up, review the conditions above. One of the better solutions is to place a moderate size capacitor very close to the input terminals. You may need two parallel capacitors. A larger electrolytic or tantalum cap sup- plies the surge current and a smaller parallel low-ESR ceramic cap gives low AC impedance. Too large an electrolytic capacitor may have higher internal impedance (ESR) and/or lower the start up slew rate enough to upset the DC/ DC’s controller. Make sure the capacitors can tolerate refl ected switching cur- rent pulses from the converter. The capacitors will not help if the input source has poor regulation. A converter which starts successfully at 3.3 Volts will turn off if the input voltage decays to below the input voltage theshold, regardless of external capacitance. Increase the input start up voltage if possible to raise the downward voltage spike. Also, make sure that the input voltage ramps up in a reasonably short time (less than a few milliseconds). If possible, move the input source closer to the converter to reduce ohmic losses in the input wiring. Remember that the input current is carried both by the wiring and the ground plane return. Make sure the ground plane uses adequate thickness copper. Run additional bus wire if necessary. Any added output capacitor should use just enough capacitance (and no more) to reduce output noise at the load and to avoid marginal thresh- old noise problems with external logic. An output cap will also “decouple” inductive reactance in the load. Certain kinds of electronic loads include “constant current” characteristics which destabilize the output with insuf- fi cient capacitance. If the wiring to the eventual load is long, consider placing this decoupling cap at the load. Use the Remote Sense input to avoid ohmic voltage drop errors. An elegant solution to start up problems is to apply the input voltage with the Remote On/Off control fi rst in the off setting (for those converters with an On/Off Control). After the specifi ed start-up delay (usually under 20 mSec), turn on the converter. The controller will have already been stabilized. The short delay will not be noticed in most applications. Be aware of applications which need “power management” (phased start up). Finally, it is challenging to model some application circuits with absolute fi delity. How low is the resistance of your ground plane? What is the inductance (and distributed capacitance) of external wiring? Even a detailed mathematical model may not get all aspects of your circuit. Therefore it is diffi cult to give cap values which serve all applications. Some experimentation may be required. Pre-Biased Startup Newer systems with multiple power voltages have an additional problem besides startup sequencing. Some sections have power already partially ap- plied (possibly because of earlier power sequencing) or have leakage power present so that the DC/DC converter must power up into an existing voltage. This power may either be stored in an external bypass capacitor or supplied by an active source. This “pre-biased” condition can also occur with some types of program- mable logic or because of blocking diode leakage or small currents passed The highest temperatures in LSN2 SIPs occur at their output inductor, whose heat is generated primarily by I 2R losses. The derating curves were developed using thermocouples to monitor the inductor temperature and varying the load to keep that temperature below +110°C under the assorted conditions of air fl ow and air temperature. Once the temperature exceeds +115°C (approx.), the thermal protection will disable the converter. Automatic restart occurs after the temperature has dropped below +110°C. As you may deduce from the derating curves and observe in the effi ciency curves on the following pages, LSN2 SIPs maintain virtually constant effi cien- cy from half to full load, and consequently deliver very impressive temperature performance even if operating at full load. Lastly, when LSN2 SIPs are installed in system boards, they are obviously subject to numerous factors and tolerances not taken into account here. If you are attempting to extract the most current out of these units under demand- ing temperature conditions, we advise you to monitor the output-inductor temperature to ensure it remains below +110°C at all times. Start Up Considerations When power is fi rst applied to the DC/DC converter, operation is different than when the converter is running and stabilized. There is some risk of start up diffi culties if you do not observe several application features. Lower output voltage converters may have more problems here since they tend to have higher output currents. Operation is most critical with any combination of the following external factors: 1 – Low initial input line voltage and/or poor regulation of the input source. 2 – Full output load current on lower output voltage converters. 3 – Slow slew rate of input voltage. 4 – Longer distance to input voltage source and/or higher external input source impedance. 5 – Limited or insuffi cient ground plane. External wiring that is too small. 6 – Too small external input capacitance. Too high ESR. 7 – High output capacitance causing a start up charge overcurrent surge. 8 – Output loads with excessive inductive reactance or constant current characteristics. If the input voltage is already at the low limit before power is applied, the start up surge current may instantaneously reduce the voltage at the input terminals to below the specifi ed minimum voltage. Even if this voltage depres- sion is very brief, this may interfere with the on-board controller and possibly cause a failed start. Or the converter may start but the input current load will now drive the input voltage below its running low limit and the converter will shut down. If you measure the input voltage before start up with a Digital Voltmeter (DVM), the voltage may appear to be adequate. Limited external capacitance and/or too high a source impedance may cause a short downward spike at power up, causing an instantaneous voltage drop. Use an oscilloscope not a DVM to observe this spike. The converter’s soft-start controller is sensitive to input voltage. What matters here is the actual voltage at the input terminals at all times. Symptoms of start-up diffi culties may include failed started, output oscil- lation or brief start up then overcurrent shutdown. Since the input voltage is

converter sinks current at start up. transient once the input power is applied and the startup sequence begins. an external active power source. external pre-biased active source. leakage currents. Test your application to be sure. external DC trim voltage applied between the Trim input and Power Common. the output range is 0.75 to 5 Volts. proper regulation, do not exceed the 3.3V output. need to vary this resistance slightly to achieve your desired output setting. Two different trim equations are used for the W3 and D12 models. Two different trim equations are used for the W3 and D12 models. Output subsystems may need +5V. Finally, peripherals use 5V and/or 12V. Figure 6. Trim Connections

between these power sources and relative voltage differences between them. mands out of disk and peripheral controllers until they are ready to go to work. cause interface logic to send a wrong “epitaph” command. by Sequencing or Tracking circuits. Some systems combine both methods. tor the output voltages of all downstream POL’s with an A/D converter system. ing and fabricating external power controls such as high-current MOSFET’s. POL may stabilize in 15 milliseconds whereas another takes 50 milliseconds. logic sequencer or rewriting software. Sequence/Track input is very fast (milliseconds). require more complex timing than that shown here. Figure 7. Power Up/Down Sequencing Controller

Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000www.murata-ps.com LSN2 Series Non-isolated, DOSA-SIP , 6/10/16A Selectable-Output DC/DC Converters MDC_LSN2.B06 Page 14 of 15 MECHANICAL SPECIFICATIONS Case B11 Case B12 DIMENSIONS ARE IN INCHES (MM) 2%!26)%7 -AXIMUM 4YPICAL %130 %130 " ! " ! 490 4YPICAL 2%!26)%7 I/O CONNECTIONS Pin Function P69 1 +Output 2V OUT Tr im

3 Common

B Power Good* 4 +Input

5 On/Off Control

  • Power Good output is optional. If not installed, the pin is omitted. I/O CONNECTIONS Pin Function P68 Pin Function P68 1 +Output 6 Common 2 +Output 7 +Input 3 +Sense In 8 +Input 4 +Output B V TRACK/Sequence

5 Common 9 Trim

A Power Good Out * 10 On/Off Control * Power Good output is optional. If not installed, the pin is omitted. 10/16 Amp Models

6 Amp Models

Dimensions are in inches (mm shown for ref. only). Components are shown for reference only. Tolerances (unless otherwise specified): .XX ± 0.02 (0.5) Angles ± 2˚

Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifi cations are subject to change without notice. © 2009 Murata Power Solutions, Inc. USA: Mansfi eld (MA), Tel: (508) 339-3000, email: sales@murata-ps.com Canada: Toronto, Tel: (866) 740-1232, email: toronto@murata-ps.com UK: Milton Keynes, Tel: +44 (0)1908 615232, email: mk@murata-ps.com France: Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: france@murata-ps.com Germany: München, Tel: +49 (0)89-544334-0, email: munich@murata-ps.com Japan: Tokyo, Tel: 3-3779-1031, email: sales_tokyo@murata-ps.com Osaka, Tel: 6-6354-2025, email: sales_osaka@murata-ps.com China: Shanghai, Tel: +86 215 027 3678, email: shanghai@murata-ps.com Guangzhou, Tel: +86 208 221 8066, email: guangzhou@murata-ps.com Singapore: Parkway Centre, Tel: +65 6348 9096, email: singapore@murata-ps.com Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfi eld, MA 02048-1151 U.S.A. Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356 www.murata-ps.com email: sales@murata-ps.com ISO 9001 and 14001 REGISTERED Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000www.murata-ps.com 03/20/09 LSN2 Series Non-isolated, DOSA-SIP , 6/10/16A Selectable-Output DC/DC Converters MDC_LSN2.B06 Page 15 of 15 Output Current (Amps) Ambient Temperature (˚C) –40 25 30 35 40 45 50 55 60 65 70 75 80 85 6.5 5.5 4.5 400 lfm 200 lfm 100 lfm Natural Convection LSN2-T/6-D12 Maximum Current Temperature Derating V OUT = 5V (air flow from input to output) Output Current (Amps) Ambient Temperature (˚C) –40 25 30 35 40 45 50 55 60 65 70 75 80 85 6.5 5.5 4.5 100 lfm Natural Convection LSN2-T/6-D12 Maximum Current Temperature Derating V OUT = 0.75V (air flow from input to output) ,3. %FFICIENCYVS,INE6OLTAGEAND,OAD#URRENT —#6 /54 ,OAD#URRENT!MPS %FFICIENCY 6). 6). 6). ,3. %FFICIENCYVS,INE6OLTAGEAND,OAD#URRENT —#6 /54 ,OAD#URRENT!MPS %FFICIENCY 6). 6). 6). Typical Performance Curves 03/20/09