LSK376 OSRAM

Document overview

  • Manufacturer or author: Provided By www.digicamel.com(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 12

Technical content

Features

 package: colorless, clear 3 mm (T1) package with specially shaped lens  feature of the device: for backlighting and LCDs with use of a reflector; solder leads with stand-off  wavelength: 633 nm (super-red), 606 nm (orange), 587 nm (yellow)  viewing angle: matched to use with external reflector, see diagram  technology: InGaAlP  optical efficiency: 11 lm/W (yellow, orange), 7 lm/W (super-red)  grouping parameter: luminous flux, wavelength  soldering methods: TTW soldering  packing: bulk, available taped on reel  ESD-withstand voltage: up to 2 kV acc. to JESD22-A114-B

Applications

 backlighting (LCD, switches, keys, displays, illuminated advertising, general lighting)  interior automotive lighting (e.g. dashboard backlighting, etc.)  coupling into light guides

LS K376, LO K376, LY K376, ■ LO_LY K376 abgekündigt nach OS-PD-2006-009 - werden nicht ersetzt werden. LO_LY K376 obsolete acc. to OS-PD-2006-009 - no replacement. Letzte Bestellung / Last Order: 15.04.2007 Letzte Lieferung / Last Delivery: 15.10.2007 Anm.: Die oben genannten Typbezeichnungen umfassen die bestellbaren Selektionen. Diese bestehen aus wenigen Helligkeitsgruppen (siehe Seite 5 für nähere Informationen). Es wird nur eine einzige Helligkeitsgruppe pro Gurt geliefert. Z.B.: LY K376-T1U2-26 bedeutet, dass auf dem Gurt nur eine der Helligkeitsgruppen T1, T2, U1 oder U2 enthalten ist. Um die Liefersicherheit zu gewährleisten, können einzelne Helligkeitsgruppen nicht bestellt werden. Gleiches gilt für die Farben, bei denen Wellenlängengruppen gemessen und gruppiert werden. Pro Gurt wird nur eine Wellenlängengruppe geliefert. Z.B.: LY K376-T1U2-26 bedeutet, dass auf dem Gurt nur eine der Wellenlängengruppen -2, -3, -4, -5 oder -6 enthalten ist (siehe Seite 5 für nähere Information). Z.B.: LS K376-S1T2-1 bedeutet, dass das Bauteil innerhalb der auf Seite 4 spezifizierten Grenzen geliefert wird. Um die Liefersicherheit zu gewährleisten, können einzelne Wellenlängengruppen nicht bestellt werden. Note: The above Type Numbers represent the order groups which include only a few brightness groups (see page 5 for explanation). Only one group will be shipped on each reel (there will be no mixing of two groups on each reel). E.g. LY K376-T1U2-26 means that only one group T1, T2, U1 or U2 will be shippable for any one reel. In order to ensure availability, single brightness groups will not be orderable. In a similar manner for colors where wavelength groups are measured and binned, single wavelength groups will be shipped on any one reel. E.g. LY K376-T1U2-26 means that only 1 wavelength group -2, -3, -4, -5 or -6 will be shippable (see page 5 for explanation). E.g. LS K376-S1T2-1 means that the device will be shiped within the specified limits as stated on page 4. In order to ensure availability, single wavelength groups will not be orderable. Bestellinformation

Ordering Information

Gehäusefarbe Color of Package Lichtstrom1) 2) Seite 12 Luminous Flux 1) 2) page 12 IF = 20 mA ΦV (mlm) Bestellnummer Ordering Code LS K376-T1U2-1 LS K376-S1U2-1 super-red colorless clear 280 ... 710 180 ... 710 Q65110A1380 Q65110A1378 ■LO K376-T1U2-24 ■LO K376-U1V2-24 ■LO K376-T1V2-24 orange colorless clear 280 ... 710 450 ... 1120 280 ... 1120 Q65110A1347 Q65110A1349 Q65110A1348 ■LY K376-T1U2-26 ■LY K376-U1V2-26 ■LY K376-T1V2-26 yellow colorless clear 280 ... 710 450 ... 1120 280 ... 1120 Q65110A1409 Q65110A1411 Q65110A1410

LS K376, LO K376, LY K376, 2007-05-30 3 Grenzwerte Maximum Ratings Bezeichnung Parameter Symbol Symbol Werte Values Einheit Unit LS, LO LY Betriebstemperatur Operating temperature range Top – 55 … + 100 °C Lagertemperatur Storage temperature range Tstg – 55 … + 100 °C Sperrschichttemperatur Junction temperature Tj + 100 °C Durchlassstrom Forward current (TA=25°C) IF 30 mA Stoßstrom Surge current t ≤ 10 μs, D = 0.005, TA=25°C IFM 1 0.2 A Sperrspannung3) Seite 12 Reverse voltage3) page 12 (TA=25°C) VR 12 V Leistungsaufnahme Power consumption (TA=25°C) Ptot 80 mW Wärmewiderstand 4) Seite 12 Thermal resistance4) page 12 Sperrschicht/Umgebung5) Seite 12 Junction/ambient5) page 12 Sperrschicht/Lötpad Junction/solder point Rth JA Rth JS 500 280 K/W K/W

LS K376, LO K376, LY K376, Kennwerte Characteristics (TA = 25 °C) Bezeichnung Parameter Symbol Symbol Werte Values Einheit Unit LS LO LY Wellenlänge des emittierten Lichtes (typ.) Wavelength at peak emission IF = 20 mA λpeak 645 610 591 nm Dominantwellenlänge6) Seite 12 (typ.) Dominant wavelength6) page 12 IF = 20 mA λdom 633 606* 587* nm Spektrale Bandbreite bei 50 % Irel max (typ.) Spectral bandwidth at 50 % Irel max IF = 20 mA Δλ 16 16 15 nm Durchlassspannung7) Seite 12 (min.) Forward voltage7) page 12 (typ.) IF = 20 mA (max.) VF VF VF 1.8 2.0 2.3 1.85 2.0 2.35 1.9 2.0 2.4 V V V Sperrstrom (typ.) Reverse current (max.) VR = 12 V IR IR 0.01 0.01 0.01 μA μA Temperaturkoeffizient von λpeak (typ.) Temperature coefficient of λpeak IF = 20 mA; –10°C ≤ T ≤ 100°C TCλpeak 0.14 0.13 0.13 nm/K Temperaturkoeffizient von λdom (typ.) Temperature coefficient of λdom IF = 20 mA; –10°C ≤ T ≤ 100°C TCλdom 0.05 0.07 0.10 nm/K Temperaturkoeffizient von VF (typ.) Temperature coefficient of VF IF = 20 mA; –10°C ≤ T ≤ 100°C Optischer Wirkungsgrad (typ.) Optical efficiency IF = 20 mA ηopt 7 11 11 lm/W * Einzelgruppen siehe Seite 5 Individual groups on page 5

LS K376, LO K376, LY K376, 2007-05-30 5 Wellenlängengruppen (Dominantwellenlänge)6) Seite 12 Wavelength Groups (Dominant Wavelength)6) page 12 Gruppe Group yellow orange Einheit Unitmin. max. min. max. 2 580 583 600 603 nm 3 583 586 603 606 nm 4 586 589 606 609 nm 5 589 592 nm 6 592 595 nm Helligkeits-Gruppierungsschema Brightness Groups Helligkeitsgruppe Brightness Group Lichtstrom1) Seite 12 Luminous Flux1) page 12 ΦV (mlm) 180 … 224 224 … 280 280 … 355 355 … 450 450 … 560 560 … 710 710 … 900 900 … 1120 Anm.: Die Standardlieferform von Serientypen beinhaltet eine untere Familiengruppe, eine obere Familiengruppe oder eine Sammelgruppe, die aus nur 4 bzw. 6 Helligkeitsgruppen bestehen. Einzelne Helligkeitsgruppen sind nicht bestellbar. Note: The standard shipping format for serial types includes either a lower family group, an upper family group or a grouping of all individual groups of 4 or 6 brightness groups. Individual brightness groups cannot be ordered Gruppenbezeichnung auf Etikett Group Name on Label Beispiel: U1-4 Example: U1-4 Helligkeitsgruppe Brightness Group Wellenlänge Wavelength U1 4 Anm.: In einer Verpackungseinheit / Gurt ist immer nur eine Gruppe für jede Selektion enthalten. Note: No packing unit / tape ever contains more than one group for each selection.

LS K376, LO K376, LY K376, Relative spektrale Emission2) Seite 12 Relative Spectral Emission2) page 12 V(λ) = spektrale Augenempfindlichkeit / Standard eye response curve Irel = f (λ); TA = 25 °C; IF = 20 mA Abstrahlcharakteristik2) Seite 12 Radiation Characteristic2) page 12 Irel = f (ϕ); TA = 25 °C OHL00841 400 100 450 500 550 600 650 700nm Irel λ Vλ yellow orange super-red 0.2 0.4 1.0 0.8 0.6 ϕ 1.0 0.8 0.6 0.4 OHL01277 50˚ 60˚ 70˚ 80˚ 90˚ 100˚

LS K376, LO K376, LY K376, 2007-05-30 7 Durchlassstrom2) Seite 12 Forward Current2) page 12 IF = f (VF); TA = 25 °C Maximal zulässiger Durchlassstrom Max. Permissible Forward Current IF = f (T) Relativer Lichtstrom2) 8) Seite 12 Relative Luminous Flux2) 8) page 12 ΦV/ΦV(20 mA) = f (IF); TA = 25 °C Relativer Lichtstrom2) Seite 12 Relative Luminous Flux2) page 12 ΦV/ΦV(25 °C) = f (Tj); IF = 20 mA OHL00232 10-1 010 110 102 mA FV FI OHL01013 00 20 40 60 80 ˚C 100 T IF temp. ambient temp. solder point A ST T AT ST mA orange super-red 100 10-1 yellow mA1 10 IF V (20 mA) 100 V

101 OHL02379

Φ Φ OHL02175 -20 0 0.4 0.8 20 40 60 1.2 (25 ˚C) V VΦ Φ 1.6 2.0 100 j T orange yellow super-redsuper-red yellow orange

LS K376, LO K376, LY K376, 2007-05-30 8 Zulässige Impulsbelastbarkeit IF = f (tp) Permissible Pulse Handling Capability Duty cycle D = parameter, TA = 25 °C LS, LO Zulässige Impulsbelastbarkeit IF = f (tp) Permissible Pulse Handling Capability Duty cycle D = parameter, TA = 85 °C LS, LO Zulässige Impulsbelastbarkeit IF = f (tp) Permissible Pulse Handling Capability Duty cycle D = parameter, TA = 25 °C LY Zulässige Impulsbelastbarkeit IF = f (tp) Permissible Pulse Handling Capability Duty cycle D = parameter, TA = 85 °C LY OHL00318 FI 10 10-5 -4 -3 10 10 -2 10-1 100 s101 102 pt 0.05 0.5 0.2 0.1 D 0.02 0.01 0.005 -210 -110 010 A D T t = P t T P IF OHL01414 FI 10 10-5 -4 -3 10 10 -2 10-1 100 s101 102 pt 0.05 0.5 0.2 0.1 D 0.02 0.01 0.005 -210 -110 010 A D T t = P t T P IF OHL00316 FI 10 10-5 -4 -3 10 10 -2 10-1 100 s101 102 pt 0.05 0.5 0.2 0.1 D 0.02 0.01 0.005 -210 -110 010 A D T t = P t T P IF OHL01415 FI 10 10-5 -4 -3 10 10 -2 10-1 100 s101 102 pt 0.05 0.5 0.2 0.1 D 0.02 0.01 0.005 -210 -110 010 A D T t = P t T P IF

LS K376, LO K376, LY K376, 2007-05-30 9 Maßzeichnung9) Seite 12 Package Outlines9) page 12 Kathodenkennung: kürzerer Lötspieß Cathode mark: short solder lead Gewicht / Approx. weight: 160 mg Empfohlenes Lötpaddesign9) Seite 12 Wellenlöten (TTW) Recommended Solder Pad9) page 12 TTW Soldering 2.05 (0.081) 2.35 (0.093) 2.9 (0.114) 3.5 (0.138) ø3.1 (0.122) ø2.8 (0.110) 4.8 (0.189) 4.4 (0.173) 3.6 (0.142) 3.2 (0.126) Cathode GEXY6712 spacing 2.54 (0.100) 0.4 (0.016) 0.6 (0.024) 0.7 (0.028) 0.4 (0.016) 0.8 (0.031) 0.4 (0.016) Area not flat 1.1 (0.043) 0.9 (0.035) 1.8 (0.071) 1.2 (0.047) 29.0 (1.142) 27.0 (1.063) 0.6 (0.024) 0.4 (0.016) 4 (0.157) OHLPY985 4.8 (0.189)

LS K376, LO K376, LY K376, Lötbedingungen Soldering Conditions Wellenlöten (TTW) (nach CECC 00802) TTW Soldering (acc. to CECC 00802) OHLY0598 50 100 150 200 250 100 150 200 250 300 T t C s 235 C 10 s C... 260 1. Welle 1. wave 2. Welle 2. wave

5 K/s 2 K/sca 200 K/s

CC... 130100

2 K/s

Zwangskühlung forced cooling Normalkurve standard curve Grenzkurven limit curves

LS K376, LO K376, LY K376, 2007-05-30 11 Attention please! The information describes the type of component and shall not be considered as assured characteristics. . Terms of delivery and rights to change design reserved. Due to technical requirements components may contain dangerous substances. For information on the types in question please contact our Sales Organization. If printed or downloaded, please find the latest version in the Internet. Packing Please use the recycling operators known to you. We can also help you – get in touch with your nearest sales office. By agreement we will take packing material back, if it is sorted. You must bear the costs of transport. For packing material that is returned to us unsorted or which we are not obliged to accept, we shall have to invoice you for any costs incurred. Components used in life-support devices or systems must be expressly authorized for such purpose! Critical components 10) page 12 may only be used in life-support devices or systems 11) page 12 with the express written approval of OSRAM OS. Revision History: 2007-05-30 Previous Version: 2006-10-04 Page Subjects (changes since last revision) Date of change 1, 2 orange, yellow obsolete acc. to OS-PD-2006-009 2006-10-04 2 ordering code cancelled 2007-05-30

LS K376, LO K376, LY K376, 2007-05-30 12 Fußnoten: 1) Helligkeitswerte werden mit einer Stromeinprägedauer von 25 ms und einer Genauigkeit von ± 11% ermittelt. 2) Wegen der besonderen Prozessbedingungen bei der Herstellung von LED können typische oder abgeleitete technische Parameter nur aufgrund statistischer Werte wiedergegeben werden. Diese stimmen nicht notwendigerweise mit den Werten jedes einzelnen Produktes überein, dessen Werte sich von typischen und abgeleiteten Werten oder typischen Kennlinien unterscheiden können. Falls erforderlich, z.B. aufgrund technischer Verbesserungen, werden diese typischen Werte ohne weitere Ankündigung geändert. 3) Die LED kann kurzzeitig in Sperrichtung betrieben werden. 4) Rth erhöht sich um 13 K/W pro mm Beinchenlänge. Minimale Beinchenlänge, Entfernung vom Verguss ist 0 mm. 5) RthJA ergibt sich bei Montage auf PC-Board FR 4(Padgröße ≥ 16 mm2 je Pad) Minimale Beinchenlänge, Entfernung vom Verguss ist 0 mm. 6) Wellenlängen werden mit einer Stromeinprägedauer von 25 ms und einer Genauigkeit von ±1 nm ermittelt. 7) Durchlassspannungen werden mit einer Stromeinprägedauer von 1 ms und einer Genauigkeit von ±0,1 V ermittelt. 8) Im gestrichelten Bereich der Kennlinien muss mit erhöhten Helligkeitsunterschieden zwischen Leuchtdioden innerhalb einer Verpackungseinheit gerechnet werden. 9) Maße werden wie folgt angegeben: mm (inch). 10) Ein kritisches Bauteil ist ein Bauteil, das in lebenserhaltenden Apparaten oder Systemen eingesetzt wird und dessen Defekt voraussichtlich zu einer Fehlfunktion dieses lebenserhaltenden Apparates oder Systems führen wird oder die Sicherheit oder Effektivität dieses Apparates oder Systems beeinträchtigt. 11) Lebenserhaltende Apparate oder Systeme sind für (a) die Implantierung in den menschlichen Körper oder (b) für die Lebenserhaltung bestimmt. Falls sie versagen, kann davon ausgegangen werden, dass die Gesundheit und das Leben des Patienten in Gefahr ist. Published by OSRAM Opto Semiconductors GmbH Wernerwerkstrasse 2, D-93049 Regensburg www.osram-os.com © All Rights Reserved. Remarks: 1) Brightness groups are tested at a current pulse duration of 25 ms and a tolerance of ± 11%. 2) Due to the special conditions of the manufacturing processes of LED, the typical data or calculated correlations of technical parameters can only reflect statistical figures. These do not necessarily correspond to the actual parameters of each single product, which could differ from the typical data and calculated correlations or the typical characteristic line. If requested, e.g. because of technical improvements, these typ. data will be changed without any further notice. 3) Driving the LED in reverse direction is suitable for short term application. 4) Each additional 1 mm of lead length increases R th by 13 K/W. Minimum lead length, distance from resin 0 mm. 5) RthJA results from mounting on PC board FR 4 (pad size ≥ 16 mm2 per pad) Minimum lead length, distance from resin 0 mm. 6) Wavelengths are tested at a current pulse duration of ms and a tolerance of ±1 nm. 7) Forward voltage are tested at a current pulse duration of 1 ms and a tolerance of ±0.1 V. 8) In the range where the line of the graph is broken, you must expect higher brightness differences between single LEDs within one packing unit. 9) Dimensions are specified as follows: mm (inch). 10) A critical component is a component used in a life-support device or system whose failure can reasonably be expected to cause the failure of that life-support device or system, or to affect its safety or the effectiveness of that device or system. 11) Life support devices or systems are intended (a) to be implanted in the human body, or (b) to support and/or maintain and sustain human life. If they fail, it is reasonable to assume that the health and the life of the user may be endangered.