LS336K OSRAM
Document overview
- Manufacturer or author: Provided By www.digicamel.com(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 12
Technical content
Features
package: colored, diffused 3 mm (T1) package feature of the device: high luminous intensity at low currents; solder leads with stand-off wavelength: 630 nm (super-red), 587 nm (yellow) viewing angle: 60° technology: InGaAlP optical efficiency: 6 lm/W (yellow) 5 lm/W (super-red) grouping parameter: luminous intensity, wavelength soldering methods: TTW soldering packing: bulk, available taped on reel ESD-withstand voltage: up to 2 kV acc. to JESD22-A114-B
Applications
optical indicators backlighting (LCD, switches, keys, displays, illuminated advertising, general lighting) interior automotive lighting (e.g. dashboard backlighting, etc.)
LS 336K, LY 336K Anm.: Die oben genannten Typbezeichnungen umfassen die bestellbaren Selektionen. Diese bestehen aus wenigen Helligkeitsgruppen (siehe Seite 5 für nähere Informationen). Es wird nur eine einzige Helligkeitsgruppe pro Gurt geliefert. Z.B.: LY 336K-K1N1-26 bedeutet, dass auf dem Gurt nur eine der Helligkeitsgruppen K1, K2, L1, L2, M1, M2 oder N1 enthalten ist. Um die Liefersicherheit zu gewährleisten, können einzelne Helligkeitsgruppen nicht bestellt werden. Gleiches gilt für die Farben, bei denen Wellenlängengruppen gemessen und gruppiert werden. Pro Gurt wird nur eine Wellenlängengruppe geliefert. Z.B.: LY 336K-K1N1-26 bedeutet, dass auf dem Gurt nur eine der Wellenlängengruppen -2, -3, -4, -5 oder -6 enthalten ist (siehe Seite 5 für nähere Information). Z.B.: LS 336K-J2M2-1 bedeutet, dass das Bauteil innerhalb der auf Seite 4 spezifizierten Grenzen geliefert wird. Um die Liefersicherheit zu gewährleisten, können einzelne Wellenlängengruppen nicht bestellt werden. Note: The above Type Numbers represent the order groups which include only a few brightness groups (see page 5 for explanation). Only one group will be shipped on each reel (there will be no mixing of two groups on each reel). E.g. LY 336K-K1N1-26 means that only one group K1, K2, L1, L2, M1, M2 or N1 will be shippable for any one reel. In order to ensure availability, single brightness groups will not be orderable. In a similar manner for colors where wavelength groups are measured and binned, single wavelength groups will be shipped on any one reel. E.g. LY 336K-K1N1-26 means that only 1 wavelength group -2, -3, -4, -5 or -6 will be shippable (see page 5 for explanation). E.g. LS 336K-J2M2-1 means that the device will be shiped within the specified limits as stated on page 4. In order to ensure availability, single wavelength groups will not be orderable. Bestellinformation
Ordering Information
fläche Color of the Light Emitting Area Lichtstärke1) Seite 12 Luminous Intensity1) page 12 IF = 2 mA IV (mcd) Lichtstrom2) Seite 12 Luminous Flux2) page 12 IF = 2 mA ΦV (mlm) Bestellnummer Ordering Code LS 336K-J2L1-1 LS 336K-K2M1-1 LS 336K-J2M2-1 20 (typ.) 31 (typ. 33 (typ. Q65110A3761 Q65110A0313 Q65110A2835 LY 336K-K1L2-26 LY 336K-L1M2-26 LY 336K-K1N1-26 25 (typ.) 40 (typ.) 47 (typ.) Q65110A3662 Q65110A3663 Q65110A2837 Vergleichstabelle für 10 mA Correllation Table for 10 mA Typ Type IF = 2 mA Emissions- farbe Color of Emission Lichtstärke1) Seite 12 Luminous Intensity 1) page 12 IF = 2 mA IV (mcd) Lichtstärke2) Seite 12 Luminous Intensity 2) page 12 IF = 10 mA IV (mcd) Lichtstrom2) Seite 12 Luminous Flux2) page 12 IF = 10 mA ΦV (mlm) LS 336K-J2L1-1 LS 336K-K2M1-1 LS 336K-J2M2-1 47 (typ.) 75 (typ.) 80 (typ.) 95 (typ.) 150 (typ.) 160 (typ.) LY 336K-K1L2-26 LY 336K-L1M2-26 LY 336K-K1N1-26 60 (typ.) 95 (typ.) 112 (typ.) 120 (typ.) 190 (typ.) 225 (typ.) Siehe auch Grafik auch Seite 7 / see also graph on page 7
LS 336K, LY 336K 2005-04-20 3 Grenzwerte Maximum Ratings Bezeichnung Parameter Symbol Symbol Wert Value Einheit Unit Betriebstemperatur Operating temperature range Top – 55 … + 100 °C Lagertemperatur Storage temperature range Tstg – 55 … + 100 °C Sperrschichttemperatur Junction temperature Tj + 100 °C Durchlassstrom Forward current (TA=25°C) IF 20 mA Stoßstrom Surge current t ≤ 10 µs, D = 0.005, TA=25°C IFM 100 mA Sperrspannung3) Seite 12 Reverse voltage3) page 12 (TA=25°C) VR 12 V Leistungsaufnahme Power consumption (TA=25°C) Ptot 40 mW Wärmewiderstand4) Seite 12 Thermal resistance4) page 12 Sperrschicht/Umgebung5) Seite 12 Junction/ambient5) page 12 Sperrschicht/Lötpad Junction/solder point Rth JA Rth JS 450 230 K/W K/W
LS 336K, LY 336K Kennwerte Characteristics (TA = 25 °C) Bezeichnung Parameter Symbol Symbol Werte Values Einheit Unit LS LY Wellenlänge des emittierten Lichtes (typ.) Wavelength at peak emission IF = 2 mA λpeak 643 591 nm Dominantwellenlänge6) Seite 12 (min.) Dominant wavelength6) page 12 (typ.) IF = 2 mA (max.) λdom λdom λdom 624 630 636 580 587* 595 nm nm nm Spektrale Bandbreite bei 50 % Irel max (typ.) Spectral bandwidth at 50 % Irel max IF = 2 mA ∆λ 16 15 nm Abstrahlwinkel bei 50 % IV (Vollwinkel) (typ.) Viewing angle at 50 % IV 2ϕ 60 60 Grad deg. Durchlassspannung7) Seite 12 (typ.) Forward voltage7) page 12 (max.) IF = 2 mA VF VF 1.8 2.2 1.8 2.2 V V Sperrstrom (typ.) Reverse current (max.) VR = 12 V IR IR 0.01 0.01 µA µA Temperaturkoeffizient von λpeak (typ.) Temperature coefficient of λpeak IF = 2 mA; –10°C ≤ T ≤ 100°C TCλpeak 0.14 0.12 nm/K Temperaturkoeffizient von λdom (typ.) Temperature coefficient of λdom IF = 2 mA; –10°C ≤ T ≤ 100°C TCλdom 0.05 0.09 nm/K Temperaturkoeffizient von VF (typ.) Temperature coefficient of VF IF = 2 mA; –10°C ≤ T ≤ 100°C TCV – 1.8 – 2.1 mV/K Optischer Wirkungsgrad (typ.) Optical efficiency IF = 2 mA ηopt 5 6 lm/W * Einzelgruppen siehe Seite 5 Individual groups on page 5
LS 336K, LY 336K 2005-04-20 5 Wellenlängengruppen (Dominantwellenlänge)6) Seite 12 Wavelength Groups (Dominant Wavelength)6) page 12 Gruppe Group yellow Einheit Unitmin. max. 2 580 583 nm 3 583 586 nm 4 586 589 nm 5 589 592 nm 6 592 595 nm Helligkeits-Gruppierungsschema Brightness Groups Helligkeitsgruppe Brightness Group Lichtstärke1) Seite 12 Luminous Intensity1) page 12 IV (mcd) Lichtstrom2) Seite 12 Luminous Flux2) page 12 ΦV (mlm) 5.6 … 7.1 7.1 … 9.0 9.0 … 11.2 11.2 … 14.0 14.0 … 18.0 18.0 … 22.4 22.4 … 28.0 28.0 … 35.5 13 (typ.) 16 (typ.) 20 (typ.) 25 (typ.) 32 (typ.) 40 (typ.) 50 (typ.) 60 (typ.) Anm.: Die Standardlieferform von Serientypen beinhaltet entweder eine untere Familiengruppe,eine obere Familiengruppe oder eine Sammelgruppe, die aus 4 bzw. 7 Helligkeitsgruppen besteht. Einzelne Helligkeitsgruppen sind nicht bestellbar. Note: The standard shipping format for serial types includes ei ther a lower family group, an upper family group or a grouping of all individual groups of 4 or 7 individual brightness groups. Individual brightness groups cannot be ordered. Gruppenbezeichnung auf Etikett Group Name on Label Beispiel: K2-3 Example: K2-3 Helligkeitsgruppe Brightness Group Wellenlänge Wavelength K2 3 Anm.: In einer Verpackungseinheit / Gurt ist immer nur eine Gruppe für jede Selektion enthalten. Note: No packing unit / tape ever contains more than one group for each selection.
LS 336K, LY 336K Relative spektrale Emission2) Seite 12 Relative Spectral Emission2) page 12 V(λ) = spektrale Augenempfindlichkeit / Standard eye response curve Irel = f (λ); TA = 25 °C; IF = 2 mA Abstrahlcharakteristik2) Seite 12 Radiation Characteristic2) page 12 Irel = f (ϕ); TA = 25 °C OHL00767 400 100 Ιrel λ nm450 500 550 600 650 700 Vλ yellow super-red 0.2 0.4 1.0 0.8 0.6 ϕ 1.0 0.8 0.6 0.4 50˚ 60˚ 70˚ 80˚ 90˚ 100˚
LS 336K, LY 336K 2005-04-20 7 Durchlassstrom2) Seite 12 Forward Current2) page 12 IF = f (VF); TA = 25 °C Relative Lichtstärke2) 8) Seite 12 Relative Luminous Intensity2) 8) page 12 IV/IV(2 mA) = f (IF); TA = 25 °C Relative Lichtstärke2) Seite 12 Relative Luminous Intensity2) page 12 IV/IV(25 °C) = f (Tj); IF = 2 mA 10-3 10-2 100 101
102 OHL00388
1.4 IF VF mA OHL00769 10-1 I 100 mA V (2 mA)I VI F 1012 10 010 110 102 super-red yellow 0.0 OHL00290 T -60 V V (25 ˚C)Ι Ι -40 -20 02 0 4 0 6 0 100 0.5 1.0 1.5 2.5 j
LS 336K, LY 336K 2005-04-20 8 Maximal zulässiger Durchlassstrom Max. Permissible Forward Current IF = f (T) Zulässige Impulsbelastbarkeit IF = f (tp) Permissible Pulse Handling Capability Duty cycle D = parameter, TA = 25 °C Zulässige Impulsbelastbarkeit IF = f (tp) Permissible Pulse Handling Capability Duty cycle D = parameter, TA = 85 °C OHL02441 002 0 4 0 60 I mA F T 100 A TA TS 0.01 0.005 0.05 0.1 0.02 0.5 0.2 1010 0 -2-3-4-5 1010 10 FI A D Pt =D T 210-1 10 tp 10 s 10 OHL02439 T tP IF 0.02 0.04 0.06 0.08 0.10 0.12 0.01 0.005 0.05 0.1 0.02 0.5 0.2 1010 0 -2-3-4-5 1010 10 FI A D Pt =D T 210-1 10 tp 10 s 10 OHL02440 T tP IF 0.02 0.04 0.06 0.08 0.10 0.12
LS 336K, LY 336K 2005-04-20 9 Maßzeichnung9) Seite 12 Package Outlines9) page 12 Kathodenkennung: kürzerer Lötspieß Cathode mark: short solder lead Gewicht / Approx. weight: 0.15 g Empfohlenes Lötpaddesign9) Seite 12 Wellenlöten (TTW) Recommended Solder Pad9) page 12 TTW Soldering 0.4 (0.016) 0.6 (0.024) 3.1 (0.122) 3.4 (0.134) Area not flat 5.7 (0.224) 6.1 (0.240) ø2.7 (0.106) ø2.9 (0.114) 4.8 (0.189) 4.4 (0.173) 3.7 (0.146) 3.5 (0.138) 27.0 (1.063) 29.0 (1.142) 0.8 (0.031) 0.4 (0.016) 0.4 (0.016) 0.7 (0.028) 1.2 (0.047) 1.8 (0.071) GEXY6045 0.9 (0.035) 1.1 (0.043) Cathode spacing 2.54 (0.100) 0.6 (0.024) 0.4 (0.016) 4 (0.157) OHLPY985 4.8 (0.189)
LS 336K, LY 336K Lötbedingungen Soldering Conditions Wellenlöten (TTW) (nach CECC 00802) TTW Soldering (acc. to CECC 00802) OHLY0598 50 100 150 200 250 100 150 200 250 300 T t C s 235 C 10 s C... 260 1. Welle 1. wave 2. Welle 2. wave
5 K/s 2 K/sca 200 K/s
CC... 130100
2 K/s
Zwangskühlung forced cooling Normalkurve standard curve Grenzkurven limit curves
LS 336K, LY 336K 2005-04-20 11 Attention please! The information describes the type of component and shall not be considered as assured characteristics. Terms of delivery and rights to change design reserved. Due to technical requirements components may contain dangerous substances. For information on the types in question please contact our Sales Organization. If printed or downloaded, please find the latest version in the Internet. Packing Please use the recycling operators known to you. We can also help you – get in touch with your nearest sales office. By agreement we will take packing material back, if it is sorted. You must bear the costs of transport. For packing material that is returned to us unsorted or which we are not obliged to accept, we shall have to invoice you for any costs incurred. Components used in life-support devices or systems must be expressly authorized for such purpose! Critical components 10) page 12 may only be used in life-support devices or systems 11) page 12 with the express written approval of OSRAM OS. Revision History: 2007-03-01 Previous Version: 2005-04-05 Page Subjects (major changes since last revision) Date of change 4 min./max. values for dominant wavelength 2004-11-04 2 new brightness groups and ordering codes 2005-04-05 2 new ordering code 2005-04-20
LS 336K, LY 336K 2005-04-20 12 Fußnoten: 1) Helligkeitswerte werden mit einer Stromeinprägedauer von 25 ms und einer Genauigkeit von ± 11% ermittelt. 2) Wegen der besonderen Prozessbedingungen bei der Herstellung von LED können typische oder abgeleitete technische Parameter nur aufgrund statistischer Werte wiedergegeben werden. Diese stimmen nicht notwendigerweise mit den Werten jedes einzelnen Produktes überein, dessen Werte sich von typischen und abgeleiteten Werten oder typischen Kennlinien unterscheiden können. Falls erforderlich, z.B. aufgrund technischer Verbesserungen, werden diese typischen Werte ohne weitere Ankündigung geändert. 3) Die LED kann kurzzeitig in Sperrichtung betrieben werden. 4) Rth erhöht sich um 13 K/W pro mm Beinchenlänge. Minimale Beinchenlänge, Entfernung vom Verguss ist 0 mm. 5) RthJA ergibt sich bei Montage auf PC-Board FR 4 (Padgröße ≥ 16 mm2 je Pad) Minimale Beinchenlänge, Entfernung vom Verguss ist 0 mm. 6) Wellenlängen werden mit einer Stromeinprägedauer von 25 ms und einer Genauigkeit von ±1 nm ermittelt. 7) Durchlassspannungen werden mit einer Stromeinprägedauer von 1 ms und einer Genauigkeit von ±0,1 V ermittelt. 8) Im gestrichelten Bereich der Kennlinien muss mit erhöhten Helligkeitsunterschieden zwischen Leuchtdioden innerhalb einer Verpackungseinheit gerechnet werden. 9) Maße werden wie folgt angegeben: mm (inch) 10) Ein kritisches Bauteil ist ein Bauteil, das in lebenserhaltenden Apparaten oder Systemen eingesetzt wird und dessen Defekt voraussichtlich zu einer Fehlfunktion dieses lebenserhaltenden Apparates oder Systems führen wird oder die Sicherheit oder Effektivität dieses Apparates oder Systems beeinträchtigt. 11) Lebenserhaltende Apparate oder Systeme sind für (a) die Implantierung in den menschlichen Körper oder (b) für die Lebenserhaltung bestimmt. Falls sie versagen, kann davon ausgegangen werden, dass die Gesundheit und das Leben des Patienten in Gefahr ist. Published by OSRAM Opto Semiconductors GmbH Wernerwerkstrasse 2, D-93049 Regensburg www.osram-os.com © All Rights Reserved. Remarks: 1) Brightness groups are tested at a current pulse duration of 25 ms and a tolerance of ± 11%. 2) Due to the special conditions of the manufacturing processes of LED, the typical data or calculated correlations of technical parameters can only reflect statistical figures. These do not necessarily correspond to the actual parameters of each single product, which could differ from the typical data and calculated correlations or the typical characteristic line. If requested, e.g. because of technical improvements, these typ. data will be changed without any further notice. 3) Driving the LED in reverse direction is suitable for short term application. 4) Each additional 1 mm of lead length increases R th by 13 K/W. Minimum lead length, distance from resin 0 mm 5) RthJA results from mounting on PC board FR 4 (pad size ≥ 16 mm2 per pad) Minimum lead length, distance from resin 0 mm 6) Wavelengths are tested at a current pulse duration of ms and a tolerance of ±1 nm. 7) Forward voltage are tested at a current pulse duration of 1 ms and a tolerance of ±0.1 V. 8) In the range where the line of the graph is broken, you must expect higher brightness differences between single LEDs within one packing unit. 9) Dimensions are specified as follows: mm (inch). 10) A critical component is a component used in a life-support device or system whose failure can reasonably be expected to cause the failure of that life-support device or system, or to affect its safety or the effectiveness of that device or system. 11) Life support devices or systems are intended (a) to be implanted in the human body, or (b) to support and/or maintain and sustain human life. If they fail, it is reasonable to assume that the health and the life of the user may be endangered.