Features

 package: SMD ceramic package with silicon resin with lens  typical Radiant Power: 332 mW at 400 mA and up to 746 mW at 1 A  feature of the device: small size high-flux LED for slim designs  centroid wavelength: 656 nm  viewing angle: 80°  technology: Thinfilm InGaAlP  typical optical efficiency: 39 % at 400 mA  grouping parameter: radiant power  assembly methods: suitable for SMT assembly methods  soldering methods: Reflow soldering  preconditioning: acc. to JEDEC Level 2  taping: 12-mm tape with 600/reel, ø180 mm  ESD-withstand voltage: up to 8 kV acc. to JESD22-A114-D  Superior Corrosion Robustness: details see page 10

Applications

 effect lighting  horticultural lighting  shoplighting  stage lighting  architectural lighting

Anm.: Die oben genannten Typbezeichnungen umfassen die bes tellbaren Selektionen. Diese bestehen aus wenigen Helligkeitsgruppen (siehe Seite 5 für nähere Informationen). Es wird nur eine einzige Helligkeitsgruppe pro Gurt geliefert. Z.B.: LH CP7P-1T3T-1 bedeutet, dass auf dem Gurt nur eine der Helligkeitsgruppen -1T, -2T oder 3T enthalten ist. Um die Liefersicherheit zu gewährleisten, können einzelne Helligkeitsgruppen nicht bestellt werden. Gleiches gilt für die Farben, bei denen Wellenlängeng ruppen gemessen und gruppiert werden. Pro Gurt wird nur eine Wellenlängengruppe geliefert. Z.B.: LH CP7P-1T3T-1 bedeutet, dass das Bauteil innerhalb der auf Seite 4 spezifizierten Grenzen geliefert wird. Note: The above Type Numbers represent the order groups which include only a few brightness groups (see page 5 for explanation). Only one group will be shipped on each reel (there will be no mixing of two groups on each reel). E.g. LH CP7P-1T3T-1 means that only one group -1, -2T or 3T will be shippable for any one reel. In order to ensure availability, single brightness groups will not be orderable. In a similar manner for colors where wavelength groups are measured and binned, single wavelength groups specified limits as stated on page 4. Bestellinformation

Ordering Information

Strahlungsleistung1) Seite 20 Radiant Power1) page 20 IF = 400 mA ΦE (mW) Bestellnummer Ordering Code min typ max LH CP7P-1T3T-1 hyper red 280 320 400 Q65111A0296

(TS=25°C) Bezeichnung Parameter Symbol Symbol Werte Values Einheit Unit Betriebstemperatur Operating temperature range Top – 40 … + 110 °C Lagertemperatur Storage temperature range Tstg – 40 … + 110 °C Sperrschichttemperatur Junction temperature Tj + 125 °C Durchlassstrom (min.) Forward current (max.) (TS=25°C) IF 100 1000 mA mA Stoßstrom Surge current t ≤ 10 μs, D = 0.1; TS=25°C IFM 2000 mA Sperrspannung Reverse voltage (TS=25°C) VR not designed for reverse operation V

(TS = 25 °C) Bezeichnung Parameter Symbol Symbol Werte Values Einheit Unit Wellenlänge des emittierten Lichtes Wavelength at peak emission (typ.) IF = 400 mA λpeak 660 nm Dominantwellenlänge3) Seite 17 Dominant wavelength3) page 17 (typ.) IF = 400 mA λdom λdom λdom 645 nm Schwerpunktwellenlänge3) Seite 17 (min. Centroid wavelength3) page 17 (typ.) IF = 400 mA (max. λcent λcent λcent 646 656 666 nm nm nm Spektrale Bandbreite bei 50 % Φrel max (typ.) Spectral bandwidth at 50 % Φrel max IF = 400 mA Δλ 25 nm Abstrahlwinkel bei 50 % ΙV (Vollwinkel) (typ.) Viewing angle at 50 % ΙV 2ϕ 80 Grad deg. Durchlassspannung4) Seite 17 (min.) Forward voltage4) page 17 (typ.) IF = 400 mA (max.) VF VF VF 2.0 2.15 2.6 V V V Sperrstrom Reverse current (max.) IR IR not designed for reverse operation Temperaturkoeffizient von λcentroid (typ.) Temperature coefficient of λcentroid IF = 400 mA; –10°C ≤ T ≤ 100°C TCλcent 0.13 nm/K Wärmewiderstand Thermal resistance Sperrschicht/Lötpad (typ.) Junction/solder point (max.) Rth JS Rth JS 9.4* K/W K/W *Rth(max) basiert auf statistischen Werten Rth(max) is based on statistic values

Helligkeits-Gruppierungsschema Brightness Groups Helligkeitsgruppe Brightness Group Strahlungsleistung1) Seite 17 Radiant Power1) page 17 ΦE (mW) 280 … 315 315 … 355 355 … 400 Anm.: Die Standardlieferform von Serientypen beinhaltet eine Familiengruppe. Diese besteht aus 3 Helligkeitsgruppen. Einzelne Helligkeitsgruppen sind nicht bestellbar. Note: The standard shipping format for serial types includes a family group of 3 individual brightness groups. Individual brightness groups cannot be ordered. Gruppenbezeichnung auf Etikett Group Name on Label Beispiel: 1T Example: 1T Helligkeitsgruppe Brightness Group Anm.: In einer Verpackungseinheit / Gurt ist immer nur eine Gruppen für jede Selektion enthalten. Note: No packing unit / tape ever contains more than one group for each selection.

Relative spektrale Emission2) Seite 17 Relative Spectral Emission2) page 17 V(λ) = spektrale Augenempfindlichkei t / Standard eye response curve Φrel = f (λ); TS = 25 °C; IF = 400 mA Abstrahlcharakteristik2) Seite 17 Radiation Characteristic2) page 17 Ιrel = f (ϕ); TS = 25°C 400 500 600 relΦ 100 Vλ 700 nm λ 800 OHL04492 OHL04325 100˚ 90˚ 80˚ 70˚ 60˚ 50˚ 0.2 0.4 0.6 0.8 1.0ϕ

Durchlassstrom2) Seite 17 Forward Current2) page 17 IF = f (VF); TS = 25 °C Relative Strahlungsleistung2) Seite 17 Relative Radiant Power2) page 17 ΦE/ΦE(400 mA) = f (IF); TS = 25 °C OHL04584 FI V mA 1.6 FV 200 400 600 800 1000 OHL04397 IF 100 mA 0.5 1.0 1.5 2.0 2.5 E ΦE ( Φ )IF 300 500 700 1000

Relative Spannung2) Seite 17 Relative Voltage2) page 17 ΔVF = VF - VF(25 °C) = f (Tj); IF = 400 mA Relative Strahlungsleistung2) Seite 17 Relative Radiant Power2) page 17 ΦE/ΦE(25 °C) = f (Tj); IF = 400 mA -40-0.15 ˚C Tj OHL04394 V FVΔ -20 0 20 40 60 80 120 -0.10 -0.05 0.05 0.10 0.15 0.25 OHL04396 Φ ( E E Φ j 0-20-40 T 80604020 ˚C 120 0.2 0.4 0.6 0.8 1.0 1.2 jT )

Maximal zulässiger Durchlassstrom Max. Permissible Forward Current IF = f (TS) Zulässige Impulsbelastbarkeit IF = f (tp) Permissible Pulse Handling Capability Duty cycle D = parameter, TS = 25 °C Zulässige Impulsbelastbarkeit IF = f (tp) Permissible Pulse Handling Capability Duty cycle D = parameter, TS = 85 °C 600 Do not use current below 100 mA 200 400 200 0 ˚C10060 80 TS 140 mA 1200 800 IF OHL04649 0.8 -5 FI A tp s OHL04184 -410 -310 -210 -110 010 110 21010 Pt =D T T tP IF 0.01 0.33 0.5 0.2 0.1 0.02 D 0.005 0.05 0.9 1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.1 0.8 -5 FI A tp s OHL04183 -410 -310 -210 -110 010 110 21010 Pt =D T T tP IF 0.01 0.33 0.5 0.2 0.1 0.02 D 0.005 0.05 0.9 1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.1

Maßzeichnung5) Seite 17 Package Outlines5) page 17 Anm.: Die LED enthält ein ESD-Bauteil, das parallel zum Chip geschalten ist. Note: LED is protected by ESD device whic h is connected in parallel to LED-Chip. Anm.: Das Gehäuse ist für Ultras challreinigung nicht geeignet Note: Package not suitalbe for ultra sonic cleaning Kathodenkennung: Markierung Cathode mark: mark Gewicht / Approx. weight: 25 mg Korrosionsfestigkeit besser als EN 60068-2-60 (method 4): mit erweitertem Korrosionstest: 40°C / 90%rh / 15ppm H2S / 336 h Corrosion robustness better than EN 60068-2-60 (method 4): with enhanced corrosion test: 40°C / 90%rh / 15ppm H2S / 336 h

Gurtung / Polarität und Lage5) Seite 16 Verpackungseinheit 600/Rolle, ø180 mm Method of Taping / Polarity and Orientation5) page 16 Packing unit 600/reel, ø180 mm

Empfohlenes Lötpaddesign5) Seite 16 Reflow Löten Recommended Solder Pad5) page 16 Reflow Soldering Anm.: Weitere Informationen finden Sie in der Applik ationsschrift „Handling and Processing Details for Ceramic LEDs“ Note: For further information please refer to our Application Note „Handling and Processing Details for Ceramic LEDs“

Lötbedingungen Vorbehandlung nach JEDEC Level 2 Soldering Conditions Preconditioning acc. to JEDEC Level 2 Reflow Lötprofil für bleifreies Löten (nach J-STD-020D.01) Reflow Soldering Profile for lead free soldering (acc. to J-STD-020D.01) Profile Feature Pb-Free (SnAgCu) Assembly Recommendation Max. Ratings Ramp-up Rate to Preheat*) 25°C to 150°C 2°C / s 3°C / s Time ts from TSmin to TSmax (150°C to 200°C 100 s min. 60 s max. 120 s Ramp-up Rate to Peak*) 180°C to TP 2°C / s 3°C / s Liquidus Temperture TL 217°C Time tL above TL 80 s max. 100 s Peak Temperature TP 245°C max. 260°C Time tP within 5°C of the specified peak temperature TP - 5K 20 s min. 10 s max. 30 s Ramp-down Rate* TP to 100°C

3 K / s 6 K / s maximum

Time 25°C to Peak temperature max. 8 min. All temperatures refer to the center of the package, measured on the top of the component * slope calculation ΔT/Δt: Δt max. 5 sec; fulfillment for the whole T-range 00 s OHA04525 100 150 200 250 300 50 100 150 200 250 300 t T St t Pt Tp240 ˚C 217 ˚C 245 ˚C 25 ˚C L

Barcode-Produkt-Etikett (BPL) Barcode-Product-Label (BPL) Gurtverpackung Tape and Ree Tape dimensions in mm (inch) W P0 P1 P2 D0 E F 4 ± 0.1 (0.157 ± 0.004) 8 ± 0.1 (0.315 ± 0.004) 2 ± 0.05 (0.079 ± 0.002) 1.5 + 0.1 (0.059 + 0.004) 1.75 ± 0.1 (0.069 ± 0.004) 5.5 ± 0.05 (0.217 ± 0.002) Reel dimensions in mm (inch) A W Nmin W1 W2 max OHA04563 (G) GROUP: 1234567890(1T) LOT NO: (9D) D/C: 1013 (X) PROD NO: 11058300 (6P) BATCH NO: 1004067407 LMW CNAP OSLON RoHS Compliant BIN1: EA-5O-0-140-D ML Temp ST 260 ˚C R Pack: R18 DEMY 022 B_R999_1880.1642 R 2000(Q)QTY: Semiconductors OSRAM Opto EA-5O-0-D W FE Direction of unreeling N A OHAY0324 Label Gurtvorlauf: Leader: Trailer: Gurtende: 13.0 Direction of unreeling ±0.25 160 mm 160 mm 400 mm 400 mm 12+ 0.3 – 0.1

Trockenverpackung und Materialien Dry Packing Process and Materials Anm.: Feuchteempfindliche Produkte sind verpackt in eine m Trockenbeutel zusammen mit einem Trockenmittel und einer Feuchteindikatorkarte Bezüglich Trockenverpackung finden Sie weitere Hinweise im Internet und in unserem Short Form Catalog im Kapitel “Gurtung und Verpackung” unter dem Punkt “T rockenverpackung”. Hier sind Normenbezüge, unter anderem ein Auszug der JEDEC-Norm, enthalten. Note: Moisture-sensitve product is packed in a dr y bag containing desiccant and a humidity card. Regarding dry pack you will find further information in the internet and in the Short Form Catalog in chapter “Tape and Reel” under the topic “Dry Pack”. Here you will also find the normative references like JEDEC. Kartonverpackung und Materialien Transportation Packing and Materials Dimensions of transportation box in mm (inch) Breite / Width Länge / length Höhe / height OHA00539 OSRAM Moisture-sensitive label or print Barcode label Desiccant Humidity indicator Barcode label OSRAM Please check the HIC immidiately after bag opening. Discard if circles overrun. Avoid metal contact. WET Do not eat. Comparator check dot parts still adequately dry. examine units, if necessary examine units, if necessary 15% 10%bake units bake units If wet, change desiccant If wet, Humidity Indicator MIL-I-8835 If wet, M oisture Level 3 Floor tim e 168 Hours M oisture Level 6 Floor tim e 6 Hours a) Hum idity Indicator Card is > 10% when read at 23 ˚C ± 5 ˚C, or reflow, vapor-phase reflow, or equivalent processing (peak package 2. After this bag is opened, devices that will be subjected to infrared 1. Shelf life in sealed bag: 24 m onths at < 40 ˚C and < 90% relative hum idity (RH). M oisture Level 5a at factory conditions of (if blank, seal date is identical with date code). a) M ounted within b) Stored at body tem 3. Devices require baking, before m ounting, if: Bag seal date M oisture Level 1 M oisture Level 2 M oisture Level 2a4. If baking is required, b) 2a or 2b is not m et. Date and tim e opened: reference IPC/JEDEC J-STD-033 for bake procedure. Floor tim e see below If blank, see bar code label Floor tim e > 1 Year Floor tim e 1 Year Floor tim e 4 W eeks10% RH. M oisture Level 4 M oisture Level 5 ˚C). OPTO SEMICONDUCTORS MOISTURE SENSITIVE This bag contains CAUTIO N Floor tim e 72 Hours Floor tim e 48 Hours Floor tim e 24 Hours 30 ˚C/60% RH. LEVEL If blank, see bar code label OHA02044 PACKVAR: R077Additional TEXT P-1+Q-1 Multi TOPLED Muster OSRAM Opto Semiconductors (6P) BATCH NO: (X) PROD NO: (9D) D/C: 11(1T) LOT NO: 210021998 123GH1234 0 245 (Q)QTY: 2000 0144 (G) GROUP:

260 C RT

240 C R

220 C R

MLBin3:Bin2: Q-1-20 Bin1: P-1-20 LSY T676 2 2a Temp ST R18 DEMY PACKVAR: R077Additional TEXT P-1+Q-1 Multi TOPLED Muster OSRAM Opto Semiconductors (6P) BATCH NO: (X) PROD NO: (9D) D/C: 11(1T) LOT NO: 21002 1998 123GH1234 0 245 (Q)QTY: 2000 0144 (G) GROUP: MLBin3:Bin2: Q-1-20 Bin1: P-1-20 LSY T676 2 2a Temp ST R18 DEMY OSRAM Packing Sealing label Barcode label M oisture Level 3 Floor tim e 16 8 H ours M oisture Level 6 Floor tim e 6 Hours a) H um idity Ind ica tor Card is > 10% when read at 23 ˚C ± 5 , or reflo w, vapor-ph ase re flow, or equivalent processing (pe ak packa ge 2. After this bag is op en ed, d evices th at w ill be subjecte d to infrare d 1. S helf life in sealed bag: 24 m onths at < 40 ˚C an d < 90% relative hum idity (R H). M oisture Level 5a at facto ry conditions of (if blan k, se al date is id entical w ith date code). a) M oun ted within b) Stored at body tem 3. D evi ces requ ire b aking , before m ounting, if: Bag seal date M oisture Level 1 M oistu re Le vel 2 M ois tu re Level 2 a4. If ba king is requ ired, b) 2a or 2b is no t m et. Date a nd tim e ope ne refe rence IPC /JED EC J-STD-03 3 for ba ke procedure. Floo r tim e see b elow If blank, see ba r co de label Floor tim e > 1 Year Floo r tim e 1 Y ear Floor time 4 We eks10% R M oisture Le vel 4 Moisture Lev el ˚C). OPT O S EMICO NDUC TORS MOISTURE SE NSIT IVE This bag containsCAUTION Floor tim e

72 Hours

e 24 Ho urs 30 ˚C/60% RH LEVEL If blank, see bar code label Barcode label

Wegen der Streichung der LED aus der IEC 60825 erfolgt die Bewertung der Augensicherheit nach dem Standard IEC 62471:2006 ("photobiological safety of lamps and lamp systems") Im Risikogruppensystem dieser CIE- Norm erfüllen die in diesem Datenblatt angegebenen LED die "exempt risk"- Gruppe (die die sich im "sichtbaren" Spektralbereich auf eine Expositionsdauer von 10000 s bezieht). Unter realen Umständen (für Expositionsdauer, Augenpupille, Betrachtungsabstand) geht damit von diesen Bauelementen keinerlei Augengefährdung aus. Grundsätzlich sollte jedoch erwähnt werden, dass intensive Lichtquellen durch ihre Blendwirkung ein hohes sekundäres Gefahrenpotenzial besitzen. Wie nach dem Blick in andere hel le Lichtquellen (z.B. Autoscheinwerfer) auch, können temporär eingeschränktes Sehverm ögen und Nachbilder je nach Situation zu Irritationen, Belästigungen, Beeinträchtigungen oder sogar Unfällen führen. Due to the cancellation of the LED from IEC 60825, the ev aluation of eye safety occurs according to the standard IEC 62471:2006 ("photobiological safety of lamps and lamp systems"). Within the risk grouping system of this CIE standard, the LEDs specified in this data sheet fall into the "exempt risk" group (relating to devices in the visible spectrum with an expos ure time of 10000 s). Under real circumstances (for exposure time, eye pupils, observation distance), it is assumed that no endangerment to the eye exists from these devices. As a matter of principle, however, it should be mentioned that intense light sources ha ve a high secondary exposure potential due to their blinding effect. As is also true when view ing other bright light sources (e.g. headlights), temporary reduction in visual acuity and afterimages can occur, l eading to irritation, annoyance, visual impairment, and even accidents, depending on the situation. Attention please! The information describes the type of component and shall not be considered as assured characteristics. Terms of delivery and rights to change design reserved. Due to technical requirements components may contain dangerous substances. For information on the types in question please contact our Sales Organization. If printed or downloaded, please find the latest version in the Internet. Packing Please use the recycling operators known to you. We can also help you – get in touch with your nearest sales office. By agreement we will take packing material back, if it is sorted. You must bear the costs of transport. For packing material that is returned to us unsorted or which we are not obliged to accept, we shall have to invoice you for any costs incurred. Components used in life-support devices or systems must be expressly authorized for such purpose! Critical components6) page 17 may only be used in life-support devices or systems ´7) page 17 with the express written approval of OSRAM OS. Revision History: 2011-03-21 Previous Version: 2010-10-28 Page Subjects (changes since last revision) Date of change all Preliminary Datasheet created 2010-06-11 16 eye safety information corrected 2010-08-03

1 Typical Luminous Flux, optical efficiency updated 2010-08-19

16 eye safety information updated 2010-08-31 16 eye safety information corrected 2010-09-09 all Final datasheet created 2010-10-28 1, 14 Taping corrected 2011-03-21 9 Max. Permissible Forward Current updated 2011-03-21

12 Note added 2011-03-21

Fußnoten: 1) Helligkeitswerte werden während eines Strompulses einer typischen Dauer von 25 ms, mit einer internen Reproduzierbarkeit von +/- 8 % und einer erweiterten Messunsicherheit von +/- 11 % gemessen (gemäß GUM mit Erweiterungsfaktor k = 3). 2) Wegen der besonderen Prozessbedingungen bei der Herstellung von LED können typische technische oder abgeleitete Parameter nur aufgrund statistischer Werte wiedergegeben werden. Diese stimmen nicht notwendigerweise mit den Werten jedes einzelnen Produktes überein, dessen Werte sich von typischen oder abgeleiteten Werten unterscheiden können. Falls erforderlich, z.B. aufgrund technischer Verbesserungen, werden diese typischen Werte ohne weitere Ankündigung geändert. 3) Die dominante Wellenlänge wird während eines Strompulses einer typischen Dauer von 25 ms, mit einer internen Reproduzierbarkeit von +/- 0,5 nm und einer erweiterten Messunsicherheit von +/- 1 nm gemessen (gemäß GUM mit Erweiterungsfaktor k = 3). 4) Vorwärtsspannungen werden während eines Strompulses einer typischen Dauer von 8 ms, mit einer internen Reproduzierbarkeit von +/- 0,05 V und einer erweiterten Messunsicherheit von +/- 0,1 V gemessen (gemäß GUM mit Erweiterungsfaktor k=3). 5) Maße werden wie folgt angegeben: mm (inch) 6) Ein kritisches Bauteil ist ein Bauteil, das in lebenserhaltenden Apparaten oder Systemen eingesetzt wird und dessen Defekt voraussichtlich zu einer Fehlfunktion dies es lebenserhaltenden Apparates oder Systems führen wird oder die Sicherheit oder Effektivität dieses Apparates oder Systems beeinträchtigt. 7) Lebenserhaltende Apparate oder Systeme sind für (a) die Implantierung in den menschlichen Körper oder (b) für die Lebenserhaltung bestimmt. Falls sie versagen, kann davon ausgegangen werden, dass die Gesundheit und das Leben des Patienten in Gefahr ist. Published by OSRAM Opto Semiconductors GmbH Leibnizstraße 4, D-93055 Regensburg www.osram-os.com © All Rights Reserved. Remarks: 1.) Brightness values are measured during a current pulse of typical 25 ms, with an internal reproducibility of +/- 8 % and an expanded uncertainty of +/- 11 % (acc. to GUM with a coverage factor of k = 3). 2) Due to the special conditions of the manufacturing processes of LED, the typical or calculated data of technical parameters can only reflect statistical figures. These do not necessarily correspond to the actual parameters of each single product, which could differ from the typical or calculated data of the typical characeristic line. If requested, e.g. because of technical improvements, these typ. data will be changed without any further notice. 3) The dominant wavelength is measured at a current pulse of typical 25 ms, with an internal reproducibility of +/- 0,5 nm and an expanded uncertainty of +/- 1 nm (acc. to GUM with a coverage factor of k=3). 4) The forward voltage is measured during a current pulse of typical 8 ms, with an internal reproducibility of +/- 0,05 V and an expanded uncertainty of +/- 0,1 V (acc. to GUM with a coverage factor of k=3). 5) Dimensions are specified as follows: mm (inch) 6) A critical component is a component used in a life-support device or system whose failure can reasonably be expected to cause the failure of that life-support device or system, or to affect its safety or the effectiveness of that device or system. 7) Life support devices or systems are intended (a) to be implanted in the human body, or (b) to support and/or maintain and sustain human life. If they fail, it is reasonable to assume that the health and the life of the user may be endangered.