LCYW5SM OSRAM

Document overview

  • Manufacturer or author: Provided By www.digicamel.com(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 22

Technical content

Version 1.2 LCY W5SM Features: Besondere Merkmale:

  • Package: white SMT package, colored diffused silicone resin
  • Gehäusetyp: weißes SMT Gehäuse, farbiger diffuser Silikon-Verguss
  • Technology: ThinGaN • Technologie: ThinGaN
  • Viewing angle at 50 % I V: 120° (Lambertian Emitter)
  • Abstrahlwinkel bei 50 % I V: 120° (Lambertscher Strahler)
  • Color: Cx = 0.56, Cy = 0.42 acc. to CIE 1931 (color on demand yellow)
  • Farbe: Cx = 0.56, Cy = 0.42 nach CIE 1931 (color on demand yellow)
  • Optical efficiency (typ.): 50 lm/W (color on demand yellow)
  • Optischer Wirkungsgrad (typ.): 50 lm/W (color on demand yellow)
  • ESD - withstand voltage: 8 kV acc. to ANSI/ESDA/JEDEC JS-001 (HBM, Class 3B)
  • ESD - Festigkeit: 8 kV nach ANSI/ESDA/JEDEC JS-001 (HBM, Klasse 3B)
  • Corrosion Robustness: Improved corrosion robustness
  • Korrosionsstabilität: Verbesserte Korrosionsstabilität Applications Anwendungen
  • Exterior Automotive Lighting • Automobilbeleuchtung außen

Version 1.2 LCY W5SM

Ordering Information

Type: Luminous Flux 1) page 21 Ordering Code Typ: Lichtstrom 1) Seite 21 Bestellnummer IF = 350 mA ΦV [lm] LCY W5SM-HZJZ-5E-1 39 ... 71 Q65111A2605 Note: The above Type Numbers represent the order gr oups which include only a few brightness groups (se e page 5). Only one group will be shipped on each packing unit (there will be no m ixing of two groups on each packing unit). E. g. LC Y W5SM-HZJZ-5E-1 means that only one group HZ, JX, JY, JZ will be shippabl e for any packing unit. In a similar manner for colors where color chromaticity coordinate groups are measured and binned, single groups will be shipped on any one packing unit. LCY W5SM-HZJZ-5E-1 means that the device will be shipped within the specified li mits. In a similar manner for colors where forward voltage groups are measured and binned, single forward voltage groups will be shipped on any packing unit. E. g. LCY W5SM-HZJZ-5E-1 means that only one forward voltage group 24,64,A4,E4 wi ll be shippable. Anm.: Die oben genannten Typbezeichnungen umfassen die bestellbaren Selektionen. Diese bestehen aus we nigen Helligkeitsgruppen (siehe Seite 5). Es wird nur eine einzige Helligkei tsgruppe pro Verpackungseinheit geliefert. Z. B. LC Y W5SM-HZJZ-5E-1 bedeutet, dass in einer Verpackungseinheit nur eine der Helli gkeitsgruppen HZ, JX, JY, JZ enhalten ist. Gleiches gilt für die Farben, bei denen Farbortgrup pen gemessen und gruppiert werden. Pro Verpackungse inheit wird nur eine Farbortgruppe geliefert. Z.B. LCY W5SM-HZJZ-5E-1 be deutet, dass in einer Verpackungseinheit nur eine d er Farbortgruppen enthalten ist. LCY W5SM-HZJZ-5E-1 bedeutet, dass da s Bauteil innerhalb der spezifizierten Grenzen geli efert wird. Gleiches gilt für die LEDs, bei denen die Durchlass spannungsgruppen gemessen und gruppiert werden. Pro Verpackungseinheit wird nur eine Durchlassspannungsgruppe geliefert. Z. B. LCY W5SM-HZJZ-5E-1 bedeutet, dass nach Durchlassspannungsgruppen gruppiert wird. In einer Verpackungseinheit ist nur eine der Durchlassspannungsgruppen 24,64,A4,E4 ent halten (siehe Seite 5).

Version 1.2 LCY W5SM 2017-06-22 3 Maximum Ratings Grenzwerte Parameter Symbol Values Unit Bezeichnung Symbol Werte Einheit Operating temperature range Betriebstemperatur Top -40 ... 125 °C Storage temperature range Lagertemperatur Tstg -40 ... 125 °C Junction temperature for short time applications * Sperrschichttemperatur für Kurzzeitanwendung * Tj 150 °C Junction temperature Sperrschichttemperatur Tj 135 °C Forward current Durchlassstrom (TS = 25 °C) IF 100 ... 500 mA Surge current Stoßstrom IFM 2500 mA Reverse voltage Sperrspannung (TS = 25 °C) VR not designed for reverse operation V ESD withstand voltage ESD Festigkeit (acc. to ANSI/ESDA/JEDEC JS-001 - HBM, Class 3B) VESD 8 kV Note : *The median lifetime (L70/B50) for Tj = 175°C is 10 0h. Anm : *Die mittlere Lebensdauer (L70/B50) bei Tj = 175°C b eträgt 100h.

Version 1.2 LCY W5SM Characteristics (TS = 25 °C; I F = 350 mA) Kennwerte Parameter Symbol Values Unit Bezeichnung Symbol Werte Einheit Chromaticity coordinates acc. to CIE 1931 2) page 21 Farbkoordinaten nach CIE 1931 2) Seite 21 (typ.) (typ.) Cx Cy 0.56 0.42 Viewing angle at 50 % I V Abstrahlwinkel bei 50 % I V (typ.) 2ϕ 120 ° Forward voltage 3) page 21 Durchlassspannung 3) Seite 21 (min.) (typ.) (max.) VF VF VF 2.80 3.20 3.60 V V V Reverse current Sperrstrom IR not designed for reverse operation Real thermal resistance junction / solder point 4) page 21 Realer Wärmewiderstand Sperrschicht / Lötpad 4) Seite 21 (typ.) (max.) Rth JS real Rth JS real 6.4 K/W K/W Note: Individual forward voltage groups see next pa ge Anm.: Durchlassspannungsgruppen siehe nächste Seite

Version 1.2 LCY W5SM 2017-06-22 5 Brightness Groups Helligkeitsgruppen Forward Voltage Groups 3) page 21 Durchlassspannungsgruppen 3) Seite 21 Group Luminous Flux 1) page 21 Luminous Flux 1) page 21 Luminous Intensity 5) page 21 Gruppe Lichtstrom 1) Seite 21 Lichtstrom 1) Seite 21 Lichtstärke 5) Seite 21 (min.) ΦV [lm] (max.) ΦV [lm] (typ.) IV [cd] HZ 39 45 13.9 JX 45 52 16 JY 52 61 18.6 JZ 61 71 21.8 Group Gruppe (min.) VF [V] (max.) VF [V] 24 2.80 3.00 64 3.00 3.20 A4 3.20 3.40 E4 3.40 3.60

Version 1.2 LCY W5SM Color Chromaticity Groups 2) page 21 Farbortgruppen 2) Seite 21 Chromaticity Coordinate Groups 2) page 21 Farbortgruppen 2) Seite 21 Group Gruppe Cx Cy 5E 0.5536 0.4221 0.5705 0.4289 0.5764 0.4075 0.5883 0.4111 OHA04041 520 530 540 550 560 570 580 590 600 610 620 630 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 510 500 490 450 Cx Cy 0.55 Cy Cx E 480 460 470 0.38 0.56 0.57 0.58 0.59 0.39 0.40 0.41 0.42 0.43 0.44 0.45

Version 1.2 LCY W5SM 2017-06-22 7 Group Name on Label Gruppenbezeichnung auf Etikett Example: HZ-5E-24 Beispiel: HZ-5E-24 Brightness Helligkeit Chromaticity Coordinate Farbort Forward Voltage Durchlassspannung HZ 5E 24 Note: No packing unit / tape ever contains more tha n one group for each selection. Anm.: In einer Verpackungseinheit / Gurt ist immer nur eine Gruppe für jede Selektion enthalten.

Version 1.2 LCY W5SM Relative Spectral Emission - V(λ) = Standard eye re sponse curve 5) page 21 Relative spektrale Emission - V(λ) = spektrale Auge nempfindlichkeit 5) Seite 21 Φrel = f (λ); T S = 25 °C; I F = 350 mA Radiation Characteristics 5) page 21 Abstrahlcharakteristik 5) Seite 21 Irel = f (ϕ); T S = 25 °C LCY W5SM 350 400 450 500 550 600 650 700 750 800 λ [ nm ] 0,0 0,2 0,4 0,6 0,8 1,0 Φ rel : Vλ : CoD Chrystal yellow LCY W5SM -100° -90° -80° -70° -60° -50° -40° -30° -20° ϕ [°] 0,0 0,2 0,4 0,6 0,8 1,0 Irel

Version 1.2 LCY W5SM 2017-06-22 9 Forward Current 5) page 21 , 6) page 21 Durchlassstrom 5) Seite 21 , 6) Seite 21 IF = f (V F); T S = 25 °C Relative Luminous Flux 5) page 21 , 6) page 21 Relativer Lichtstrom 5) Seite 21 , 6) Seite 21 ΦV/Φ V(350 mA) = f(I F); T S = 25 °C Chromaticity Coordinate Shift 5) page 21 Farbortverschiebung 5) Seite 21 ΔCx, ΔCy = f(I F); T S = 25 °C LCY W5SM VF [ V] 100 200 300 400

500 IF [ mA ]

100 150 200 250 300 350 400 450 500 IF [ mA ] 0,0 0,2 0,4 0,6 0,8 1,0 1,2 1,4 Φ V Φ V(350 mA ) LCY W5SM 100 150 200 250 300 350 400 450 500 IF [ mA ] -0,03 -0,02 -0,01 0,00 0,01 0,02 0,03 ΔCx ΔCy : Δ Cx : Δ Cy

Version 1.2 LCY W5SM Relative Forward Voltage 5) page 21 Relative Vorwärtsspannung 5) Seite 21 ΔV F = V F - V F(25 °C) = f(T j); I F = 350 mA Relative Luminous Flux 5) page 21 Relativer Lichtstrom 5) Seite 21 ΦV/Φ V(25 °C) = f(T j); I F = 350 mA Chromaticity Coordinate Shift 5) page 21 Farbortverschiebung 5) Seite 21 ΔCx, ΔCy = f(Tj); I F = 350 mA LCY W5SM -40 -20 0 20 40 60 80 100 120 Tj [ °C ] -0,3 -0,2 -0,1 0,0 0,1 0,2 0,3 ΔVF [ V] LCY W5SM -40 -20 0 20 40 60 80 100 120 Tj [ °C ] 0,0 0,2 0,4 0,6 0,8 1,0 1,2 Φ v Φ v(25 °C ) LCY W5SM -40 -20 0 20 40 60 80 100 120 Tj [ °C ] -0,03 -0,02 -0,01 0,00 0,01 0,02 0,03 ΔCx ΔCy : Δ Cx : Δ Cy

Version 1.2 LCY W5SM 2017-06-22 11 Max. Permissible Forward Current Max. zulässiger Durchlassstrom IF = f(T S) Permissible Pulse Handling Capability Zulässige Impulsbelastbarkeit I F = f(t p) D: Duty cycle LCY W5SM 0 20 40 60 80 100 120 T [ °C ] 0,00 0,05 0,10 0,15 0,20 0,25 0,30 0,35 0,40 0,45 0,50 0,55 IF [ A] : Ts 10 -6 10 -5 10 -4 10 -3 0,01 0,1 1 10 Pulse time [ s] 0,5 1,0 1,5 2,0 2,5 3,0 IF [ A] TS = 0°C ... 125°C LCY W5SM : D = 1.0 : D = 0.5 : D = 0.2 : D = 0.1 : D = 0.05 : D = 0.02 : D = 0.01 : D = 0.005

Version 1.2 LCY W5SM Package Outline 7) page 21 Maßzeichnung 7) Seite 21 Approximate Weight: 0.2 g Gewicht: 0.2 g Mark: Cathode Markierung: Kathode Corrosion robustness: Test conditions: 40 °C / 90 % rh / 15 ppm H 2S / 336 h = Stricter than IEC 60068-2-43 (H 2S) [25°C / 75 % rh / 10 ppm H 2S / 21 days] = Regarding relevant gas (H 2S) stricter than EN 60068-2-60 (method 4) [25 °C / 75 % rh / 200 ppb SO 2, 200 ppb NO 2, 10 ppb Cl 2 / 21 days] Korrosionsfestigkeit: Test Kondition: 40°C / 90 % rh / 15 ppm H 2S / 336 h = Besser als IEC 60068-2-43 (H 2S) [25°C / 75 % rh / 10 ppm H 2S / 21 Tage] = Bezogen auf das Gas (H 2S) besser als EN 60068-2-60 (method 4) [25°C / 75 % rh / 200ppb SO 2, 200ppb NO 2, 10ppb Cl 2 / 21 Tage]

Version 1.2 LCY W5SM 2017-06-22 13 Recommended Solder Pad 7) page 21 Reflow soldering Empfohlenes Lötpaddesign 7) Seite 21 Reflow-Löten Note: For superior solder joint connectivity results we recommend soldering under standard nitrogen atmosphere. Package not suitable for ultra sonic cleaning. Anm.: Um eine verbesserte Lötstellenkontaktierung zu erreichen, empfehlen wir, unter Standard- Stickstoffatmosphäre zu löten. Das Gehäuse ist für Ultraschallreinigung nicht geeignet. Solder resist Freies Kupfer Bare Copper Lötpasten Schablone Solder paste stencil Lötstopplack OHAY0681 0.3 (0.012) Kupfer Copper 1.6 (0.063) 11.6 (0.457) 12.0 (0.472) 2.3 (0.091) 2.3 (0.091) 10 (0.394) 1.6 (0.063) 11.6 (0.457)

3 Lötstellen

ø4.0 (0.157) Heatsink attachø4.0 (0.157) ø2.5 (0.098)

Version 1.2 LCY W5SM Reflow Soldering Profile Reflow-Lötprofil Product complies to MSL Level 2 acc. to JEDEC J-STD -020E 00 s OHA04525 100 150 200 250 300 50 100 150 200 250 300 t T St t Pt Tp240 ˚C 217 ˚C 245 ˚C 25 ˚C L OHA04612 Profile Feature Profil-Charakteristik Ramp-up rate to preheat*) 25 °C to 150 °C 2 3 K/s Time tS TSmin to TSmax tS tL tP TL TP 100 12060 10 20 30 80 100 217 2 3 245 260 3 6 Time 25 °C to T P Time within 5 °C of the specified peak temperature TP - 5 K Ramp-down rate* TP to 100 °C All temperatures refer to the center of the package, measured on the top of the component * slope calculation DT/ Dt: Dt max. 5 s; fulfillment for the whole T-range Ramp-up rate to peak*) TSmax to T P Liquidus temperature Peak temperature Time above liquidus temperature Symbol Symbol Unit Einheit Pb-Free (SnAgCu) Assembly Minimum MaximumRecommendation K/s K/s s s s s 480

Version 1.2 LCY W5SM 2017-06-22 15 Taping 7) page 21 Gurtung 7) Seite 21 OHAY0508 4 (0.157) 6.35 (0.250) 8 (0.315) 1.75 (0.069) 11.5 (0.453) 12.4 (0.488) 24 (0.945) 0.3 (0.012) 0.3 (0.012) 1.9 (0.075) 7.35 (0.289) Cathode/Collector Side

Version 1.2 LCY W5SM Tape dimensions [mm] Gurtmaße [mm] Tape dimensions in mm Reel dimensions [mm] Rollenmaße [mm] Reel dimensions in mm Tape and Reel Gurtverpackung 24 mm tape with 800 pcs. on ∅ 180 mm reel W P0 P1 P2 D0 E F or 12 ± 0.1 A W Nmin W1 W2max 180 24 60 / 100 24.4 + 2 30.4 W F E Direction of unreeling N A OHAY0324 Label Leader: Trailer: 13.0 Direction of unreeling ±0.25 min. 160 mm * min. 400 mm * *) Dimensions acc. to IEC 60286-3; EIA 481-D

Version 1.2 LCY W5SM 2017-06-22 17 Barcode-Product-Label (BPL) Barcode-Produkt-Etikett (BPL) Dry Packing Process and Materials Trockenverpackung und Materialien Note: Moisture-sensitive product is packed in a dry bag c ontaining desiccant and a humidity card. Regarding dry pack you will find further informatio n in the internet and in the Short Form Catalog in chapter “Tape and Reel” under the topic “Dry Pack”. Here you will also find the normative refere nces like JEDEC. Anm.: Feuchteempfindliche Produkte sind verpackt in einem Trockenbeutel zusammen mit einem Trockenmittel und einer Feuchteindikatorkarte. Bezüglich Trockenverpackung finden Sie weitere Hinw eise im Internet und in unserem Short Form Catalog im Kapitel “Gurtung und Verpackung” unter dem Punkt “Trockenverpackung”. Hier sind Norm enbezüge, unter anderem ein Auszug der JEDEC-Norm, enthalten. OHA00539 OSRAM Moisture-sensitive label or print Barcode label Desiccant Humidity indicator Barcode label OSRAM Please check the HIC immidiately after bag opening. Discard if circles overrun. Avoid metal contact. WET Do not eat. Comparatorcheck dot parts still adequately dry. examine units, if necessary examine units, if necessary 15% 10%bake units bake units If wet, change desiccant If wet, Humidity Indicator MIL-I-8835 If wet, Moisture Level 3 Floor time 168 Hours Moisture Level 6 Floor time 6 Hours a) Humidity Indicator Card is > 10% when read at 23 ˚C ± 5 ˚C, or reflow, vapor-phase reflow, or equivalent processing (peak package2. After this bag is opened, devices that will be subjected to infrared 1. Shelf life in sealed bag: 24 months at < 40 ˚C and < 90% relative humidity (RH). Moisture Level 5a at factory conditions of (if blank, seal date is identical with date code). a) Mounted within b) Stored at body temp. 3. Devices require baking, before mounting, if: Bag seal date Moisture Level 1 Moisture Level 2 Moisture Level 2a 4. If baking is required, b) 2a or 2b is not met. Date and time opened: reference IPC/JEDEC J-STD-033 for bake procedure. Floor time see below If blank, see bar code label Floor time > 1 Year Floor time 1 Year Floor time 4 Weeks 10% RH._< Moisture Level 4 Moisture Level 5 ˚C). OPTO SEMICONDUCTORS MOISTURE SENSITIVE This bag containsCAUTION Floor time 72 Hours Floor time 48 Hours Floor time 24 Hours 30 ˚C/60% RH._< LEVEL If blank, seebar code label

Version 1.2 LCY W5SM Transportation Packing and Materials Kartonverpackung und Materialien Dimensions of transportation box in mm Width Length Height Breite Länge Höhe 195 ± 5 195 ± 5 42 ± 5 OHA02044 PACKVAR:R077Additional TEXT P-1+Q-1Multi TOPLED Muster OSRAM OptoSemiconductors (6P) BATCH NO: (X) PROD NO: (9D) D/C: 1 1(1T) LOT NO: 210021998 123GH1234 0 2 4 5 (Q)QTY: 2000 0144 (G) GROUP:

260 C RT240 C R

220 C RML

Bin3:Bin2: Q-1-20Bin1: P-1-20 LSY T676 2 2a Temp ST R18 DEMY PACKVAR:R077Additional TEXT P-1+Q-1Multi TOPLED Muster OSRAM OptoSemiconductors (6P) BATCH NO: (X) PROD NO: (9D) D/C: 1 1(1T) LOT NO: 210021998 123GH1234 0 2 4 5 (Q)QTY: 2000 0144 (G) GROUP: Bin3:Bin2: Q-1-20Bin1: P-1-20 LSY T676 2 2a Temp ST R18 DEMY OSRAM Packing Sealing label Barcode label Moisture Level 3 Floor time 168 Hours Moisture Level 6 Floor time 6 Hours a) Humidity Indicator Card is > 10% when read at 23 ˚C ± 5 ˚C, or reflow, vapor-phase reflow, or equivalent processing (peak package2. After this bag is opened, devices that will be subjected to infrared 1. Shelf life in sealed bag: 24 months at < 40 ˚C and < 90% relative humidity (RH). Moisture Level 5a at factory conditions of (if blank, seal date is identical with date code). a) Mounted within b) Stored at body temp. 3. Devices require baking, before mounting, if: Bag seal date Moisture Level 1 Moisture Level 2 Moisture Level 2a 4. If baking is required, b) 2a or 2b is not met. Date and time opened: reference IPC/JEDEC J-STD-033 for bake procedure. Floor time see below If blank, see bar code label Floor time > 1 Year Floor time 1 Year Floor time 4 Weeks 10% RH._< Moisture Level 4 Moisture Level 5 ˚C). OPTO SEMICONDUCTORS MOISTURE SENSITIVE This bag containsCAUTION Floor time 72 Hours Floor time 48 Hours Floor time 24 Hours 30 ˚C/60% RH._< LEVEL If blank, seebar code label Barcode label

Version 1.2 LCY W5SM 2017-06-22 19 Notes Hinweise The evaluation of eye safety occurs according to th e standard IEC 62471:2008 ("photobiological safety of lamps and lamp systems"). Within the risk grouping system of this CIE standard, the LED specified in this data sheet fall into the class Exempt group (exposure time 10000 s). Under real circumstances (for exposure time, eye pupils, observation distance), it is assumed that no endangerment to the eye exists from these devices. As a matter of principle, however, it should be mentioned that intense light sources have a high secondary exposure potential due to their blinding effect. As is also true when viewing other bright light sources (e.g. headlights ), temporary reduction in visual acuity and afterimage s can occur, leading to irritation, annoyance, visual impairment, and even accidents, depending on the situation. Die Bewertung der Augensicherheit erfolgt nach dem Standard IEC 62471:2008 ("photobiological safety of lamps and lamp systems"). Im Risikogruppensystem dieser CIE- Norm erfüllen die in diesem Datenblatt angegebenen LEDs folgende Gruppenanforderung - Exempt group (Expositionsdauer 10000 s). Unter realen Umständen (für Expositionsdauer, Augenpupille, Betrachtungsabstand) geht damit von diesen Bauelementen keinerlei Augengefährdung aus. Grundsätzlich sollte jedoch erwähnt werden, dass intensive Lichtquellen durch ihre Blendwirkung ein hohes sekundäres Gefahrenpotenzial besitzen. Nach einem Blick in eine helle Lichtquelle (z.B. Autoscheinwerfer), kann ein temporär eingeschränktes Sehvermögen oder auch Nachbilder zu Irritationen, Belästigungen, Beeinträchtigungen oder sogar Unfällen führen. Subcomponents of this LED contain, among other substances, goldplated and Ag-filled materials. In spite of the improved corrosion stability of this LED, it can be affected by environments that contain very high concentrations of aggressive substances. Therefore, we recommend avoiding aggressive atmospheres during storage, production and use. Einzelkomponenten dieser LED enthalten u.a. goldbeschichtete und Ag-gefüllte Materialien. Trotz der verbesserten Korrosionsstabilität dieser LED können Einzelkomponenten durch sehr hohe Konzentration aggressiver Substanzen angegriffen werden. Aus diesem Grund wird empfohlen, aggressive Umgebungen während der Lagerung, Produktion und im Betrieb zu vermeiden. For further application related informations please visit www.osram-os.com/appnotes Für weitere applikationsspezifische Informationen besuchen Sie bitte www.osram-os.com/appnotes

Version 1.2 LCY W5SM Disclaimer Disclaimer Language english will prevail in case of any discrepancies or deviations between the two languag e wordings. Attention please! The information describes the type of component and shall not be considered as assured characteristics. Terms of delivery and rights to change design reserved. Due to technical requirements components may contain dangerous substances. For information on the types in question please con tact our Sales Organization. If printed or downloaded, please find the latest ve rsion in the Internet. Packing Please use the recycling operators known to you. We can also help you – get in touch with your nearest sales office. By agreement we will take packing material back, if it is sorted. You must bear the costs of transport. For packing material that is returned to us unsorted or which we are not obliged to accept, we shall have to invo ice you for any costs incurred. Components used in life-support devices or systems must be expressly authorized for such purpose! Critical components* may only be used in life-suppo rt devices** or systems with the express written appro val of OSRAM OS. *) A critical component is a component used in a life-support device or system whose failure can reasonably be expected to cause the failure of that life-support device or system, or to affect its saf ety or the effectiveness of that device or system. **) Life support devices or systems are intended (a ) to be implanted in the human body, or (b) to support and/or maintain and sustain human life. If they fai l, it is reasonable to assume that the health and the life o f the user may be endangered. Bei abweichenden Angaben im zweisprachigen Wortlaut haben die Angaben in englischer Sprache Vorrang. Bitte beachten! Lieferbedingungen und Änderungen im Design vorbehalten. Aufgrund technischer Anforderungen können die Bauteile Gefahrstoffe enthalten. Für wei tere Informationen zu gewünschten Bauteilen, wenden Sie sich bitte an unseren Vertrieb. Falls Sie dieses Datenblatt ausgedruckt oder heruntergeladen haben, finden Sie die aktuellste Version im Internet. Verpackung Benutzen Sie bitte die Ihnen bekannten Recyclingwege. Wenn diese nicht bekannt sein sollte n, wenden Sie sich bitte an das nächstgelegene Vertriebsbüro. Wir nehmen das Verpackungsmaterial zurück, falls dies vereinbart wurde und das Materia l sortiert ist. Sie tragen die Transportkosten. Für Verpackungsmaterial, das unsortiert an uns zurückgeschickt wird oder das wir nicht annehmen müssen, stellen wir Ihnen die anfallenden Kosten in Rechnung. Bauteile, die in lebenserhaltenden Apparaten und Systemen eingesetzt werden, müssen für diese Zwecke ausdrücklich zugelassen sein! Kritische Bauteile* dürfen in lebenserhaltenden Apparaten und Systemen** nur dann eingesetzt werden, wenn ein schriftliches Einverständnis von OSRAM OS vorliegt. *) Ein kritisches Bauteil ist ein Bauteil, das in lebenserhaltenden Apparaten oder Systemen eingesetzt wird und dessen Defekt voraussichtlich z u einer Fehlfunktion dieses lebenserhaltenden Apparates oder Systems führen wird oder die Sicherheit oder Effektivität dieses Apparates oder Systems beeinträchtigt. **) Lebenserhaltende Apparate oder Systeme sind für (a) die Implantierung in den menschlichen Körper od er (b) für die Lebenserhaltung bestimmt. Falls Sie versagen, kann davon ausgegangen werden, dass die Gesundheit und das Leben des Patienten in Gefahr is t.

Version 1.2 LCY W5SM 2017-06-22 21 Glossary Glossar 1) Brightness: Brightness values are measured during a current pulse of typically 25 ms, with an interna l reproducibility of ± 8 % and an expanded uncertaint y of ± 11 % (acc. to GUM with a coverage factor of k = 3). 1) Helligkeit: Helligkeitswerte werden während eines Strompulses einer typischen Dauer von 25 ms, mit einer internen Reproduzierbarkeit von ± 8 % und einer erweiterten Messunsicherheit von ± 11 % gemessen (gemäß GUM mit Erweiterungsfaktor k = 3). 2) Chromaticity coordinate groups: Chromaticity coordinates are measured during a current pulse of typically 25 ms, with an internal reproducibility o f ± 0.005 and an expanded uncertainty of ± 0.01 (acc. to GUM with a coverage factor of k = 3). 2) Farbortgruppen: Farbkoordinaten werden während eines Strompulses einer typischen Dauer von 25 ms, mit einer internen Reproduzierbarkeit von ± 0,005 und einer erweiterten Messunsicherheit von ± 0,01 gemessen (gemäß GUM mit Erweiterungsfaktor k = 3). 3) Forward Voltage: The forward voltage is measured during a current pulse of typically 8 ms, with an internal reproducibility of ± 0.05 V and an expande d uncertainty of ± 0.1 V (acc. to GUM with a coverage factor of k = 3). 3) Durchlassspannung: Vorwärtsspannungen werden während eines Strompulses einer typischen Dauer von 8 ms, mit einer internen Reproduzierbarkeit von ± 0,05 V und einer erweiterten Messunsicherheit von ± 0,1 V gemessen (gemäß GUM mit Erweiterungsfaktor k = 3). 4) Thermal Resistance: Rth max is based on statistic values (6σ). 4) Wärmewiderstand: Rth max basiert auf statistischen Werten (6σ). 5) Typical Values: Due to the special conditions of the manufacturing processes of LED, the typical data or calculated correlations of technical parameters can only reflect statistical figures. These do not necessarily correspond to the actual parameters of each single product, which could differ from the typical data and calculated correlations or the typ ical characteristic line. If requested, e.g. because of technical improvements, these typ. data will be changed without any further notice. 5) Typische Werte: Wegen der besonderen Prozessbedingungen bei der Herstellung von LED können typische oder abgeleitete technische Parameter nur aufgrund statistischer Werte wiedergegeben werden. Diese stimmen nicht notwendigerweise mit den Werten jedes einzelnen Produktes überein, dessen Werte sich von typischen und abgeleiteten Werten oder typischen Kennlinien unterscheiden können. Falls erforderlich, z.B. aufgrund technischer Verbesserungen, werden diese typischen Werte ohne weitere Ankündigung geändert. 6) Characteristic curve: In the range where the line of the graph is broken, you must expect higher differences between single LEDs within one packing unit. 6) Kennlinien: Im gestrichelten Bereich der Kennlinien muss mit erhöhten Abweichungen zwischen Leuchtdioden innerhalb einer Verpackungseinheit gerechnet werden. 7) Tolerance of Measure: Unless otherwise noted in drawing, tolerances are specified with ±0.1 and dimensions are specified in mm. 7) Maßtoleranz: Wenn in der Zeichnung nicht anders angegeben, gilt eine Toleranz von ±0,1. Maße werden in mm angegeben.

Version 1.2 LCY W5SM Published by OSRAM Opto Semiconductors GmbH Leibnizstraße 4, D-93055 Regensburg www.osram-os.com © All Rights Reserved.