LCBM67S-N2R1-4R6T OSRAM

Document overview

  • Manufacturer or author: Provided By www.digicamel.com(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 22

Technical content

Version 2.3 LCB M67S CoD blue Cx=0.19 / Cy=0.19 Features: Besondere Merkmale:

  • Package: white SMT package, colored diffused resin
  • Gehäusetyp: weißes SMT Gehäuse, farbiger diffuser Verguss
  • Technology: InGaN • Technologie: InGaN
  • Viewing angle at 50 % I V: 120° (Lambertian Emitter)
  • Abstrahlwinkel bei 50 % I V: 120° (Lambertscher Strahler)
  • Color: Cx = 0.19, Cy = 0.19 acc. to CIE 1931 (color on demand blue)
  • Farbe: Cx = 0.19, Cy = 0.19 nach CIE 1931 (color on demand blau)
  • Corrosion Robustness: Improved corrosion robustness
  • Korrosionsstabilität: Verbesserte Korrosionsstabilität Applications Anwendungen
  • Automotive Interior Lighting • Automobilbeleuchtung innen
  • Signal and Symbol Luminary • Signal- und Symbolleuchten
  • Backlighting • Hinterleuchtung
  • Outdoor displays • Informationsanzeigen im Außenbereich

Version 2.3 LCB M67S CoD blue Cx=0.19 / Cy=0.19

Ordering Information

Type: Luminous Intensity 1) page 21 Ordering Code Typ: Lichtstärke 1) Seite 21 Bestellnummer IF = 10 mA IV [mcd] LCB M67S-N2R1-4R6T 35.5 ... 140 Q65111A0445 Note: The above Type Numbers represent the order gr oups which include only a few brightness groups (see page 5). Only one group will be shipped on each packing unit (there will be no m ixing of two groups on each packing unit). E. g. LC B M67S-N2R1-4R6T means that only one group N2, P1, P2, Q1, Q2, R1 will be shippable for any packing unit. In a similar manner for colors where color chromaticity coordinate groups are measured and binned, single groups will be shipped on any one packing unit. LCB M67S-N2R1-4R6T means that the device will be shipped within the specified limits. Anm.: Die oben genannten Typbezeichnungen umfassen die bestellbaren Selektionen. Diese bestehen aus we nigen Helligkeitsgruppen (siehe Seite 5). Es wird nur eine einzige Helligkeitsgruppe pro Verpackungseinheit geliefert. Z. B. LCB M67S-N2R1-4R6T bedeutet, dass in einer Verpackungseinheit nur eine der Helligkeitsgruppen N2, P1, P2, Q1, Q2, R1 enhalten ist. Gleiches gilt für die Farben, bei denen Farbortgrup pen gemessen und gruppiert werden. Pro Verpackungse inheit wird nur eine Farbortgruppe geliefert. Z.B. LCB M67S-N2R1-4R6T be deutet, dass in einer Verpackungseinheit nur eine d er Farbortgruppen enthalten ist. LCB M67S-N2R1-4R6T bedeutet, dass das Bauteil innerhalb der spezifizierten Grenzen geliefert wird.

Version 2.3 LCB M67S CoD blue Cx=0.19 / Cy=0.19 2015-08-20 3 Maximum Ratings Grenzwerte Parameter Symbol Values Unit Bezeichnung Symbol Werte Einheit Operating temperature range Betriebstemperatur Top -40 ... 100 °C Storage temperature range Lagertemperatur Tstg -40 ... 100 °C Junction temperature Sperrschichttemperatur Tj 110 °C Forward current Durchlassstrom (TS = 25 °C) IF 15 mA Surge current Stoßstrom IFM 150 mA Reverse voltage 2) page 21 Sperrspannung 2) Seite 21 (TS = 25 °C) VR 5 V ESD withstand voltage ESD Festigkeit (acc. to ANSI/ESDA/JEDEC JS-001 - HBM) VESD up to 2 kV

Version 2.3 LCB M67S CoD blue Cx=0.19 / Cy=0.19 Characteristics (TS = 25 °C; I F = 10 mA) Kennwerte Parameter Symbol Values Unit Bezeichnung Symbol Werte Einheit Chromaticity coordinates acc. to CIE 1931 3) page 21 Farbkoordinaten nach CIE 1931 3) Seite 21 (typ.) (typ.) Cx Cy 0.19 0.19 Viewing angle at 50 % I V Abstrahlwinkel bei 50 % I V (typ.) 2ϕ 120 ° Forward voltage 4) page 21 Durchlassspannung 4) Seite 21 (min.) (typ.) (max.) VF VF VF 2.70 3.10 3.40 V V V Reverse current Sperrstrom (VR = 5 V) (typ.) (max.) IR IR 0.01 µA µA Real thermal resistance junction / ambient 5) page 21 , 6) page 21 Realer Wärmewiderstand Sperrschicht / Umgebung 5) Seite 21 , 6) Seite 21 (max.) R th JA real 480 K/W Real thermal resistance junction / solder point 6) page 21 Realer Wärmewiderstand Sperrschicht / Lötpad 6) Seite 21 (max.) R th JS real 230 K/W

Version 2.3 LCB M67S CoD blue Cx=0.19 / Cy=0.19 2015-08-20 5 Brightness Groups Helligkeitsgruppen Group Luminous Intensity 1) page 21 Luminous Intensity 1) page 21 Luminous Flux 7) page 21 Gruppe Lichtstärke 1) Seite 21 Lichtstärke 1) Seite 21 Lichtstrom 7) Seite 21 (min.) Iv [mcd] (max.) Iv [mcd] (typ.) ΦV [mlm] N2 35.5 45 120 P1 45 56 150 P2 56 71 190 Q1 71 90 240 Q2 90 112 300 R1 112 140 380

Version 2.3 LCB M67S CoD blue Cx=0.19 / Cy=0.19 Color Chromaticity Groups 3) page 21 Farbortgruppen 3) Seite 21 Chromaticity Coordinate Groups 3) page 21 Farbortgruppen 3) Seite 21 Group Gruppe Cx Cy Group Gruppe Cx Cy Group Gruppe Cx Cy OHA04400 520 530 540 550 560 570 580 590 600 610 620 630 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 510 500 490 450 Cx Cy Cx E 480 460 470 Cy 0.17 0.15 0.18 0.19 0.20 0.21 0.16 0.17 0.18 0.19 0.20 0.21 0.22 0.23 4S 4T 5R 5S 5T 6R 6S 6T

Version 2.3 LCB M67S CoD blue Cx=0.19 / Cy=0.19 2015-08-20 7 Group Name on Label Gruppenbezeichnung auf Etikett Example: N2-4R Beispiel: N2-4R Brightness Helligkeit Chromaticity Coordinate Farbort N2 4R Note: No packing unit / tape ever contains more tha n one group for each selection. Anm.: In einer Verpackungseinheit / Gurt ist immer nur eine Gruppe für jede Selektion enthalten.

Version 2.3 LCB M67S CoD blue Cx=0.19 / Cy=0.19 Relative Spectral Emission - V(λ) = Standard eye response curve 7) page 21 Relative spektrale Emission - V(λ) = spektrale Augenempfindlichkeit 7) Seite 21 Irel = f (λ); T S = 25 °C; I F = 10 mA Radiation Characteristics 7) page 21 Abstrahlcharakteristik 7) Seite 21 Irel = f (ϕ); T S = 25 °C LCB M67S CoD blue SB 350 400 450 500 550 600 650 700 750 800 λ [nm] 0,0 0,2 0,4 0,6 0,8 1,0 I rel : Vλ : CoD blue LCB M67S CoD blue SB -100° -90° -80° -70° -60° -50° -40° -30° -20° ϕ [°] 0,0 0,2 0,4 0,6 0,8 1,0 Irel

Version 2.3 LCB M67S CoD blue Cx=0.19 / Cy=0.19 2015-08-20 9 Forward Current 7) page 21 , 8) page 21 Durchlassstrom 7) Seite 21 , 8) Seite 21 IF = f (V F); T S = 25 °C Relative Luminous Intensity 7) page 21 , 8) page 21 Relative Lichtstärke 7) Seite 21 , 8) Seite 21 IV/I V(10 mA) = f(I F); T S = 25 °C Chromaticity Coordinate Shift 7) page 21 Farbortverschiebung 7) Seite 21 ΔCx, ΔCy = f(I F); T S = 25 °C LCB M67S CoD blue SB VF [V] IF [mA] : CoD blue LCB M67S CoD blue SB 1 2 3 4 5 10 IF [mA] 0,2 0,3 0,4 0,5 IV I V(10 mA ) : CoD blue LCB M67S CoD blue SB 1 15 2 4 6 8 10 12 IF [mA] -0,02 -0,01 0,00 0,01 0,02 ΔCx ΔCy : Δ Cx : Δ Cy

Version 2.3 LCB M67S CoD blue Cx=0.19 / Cy=0.19 Relative Forward Voltage 7) page 21 Relative Vorwärtsspannung 7) Seite 21 ΔV F = V F - V F(25 °C) = f(T j); I F = 10 mA Relative Luminous Intensity 7) page 21 Relative Lichtstärke 7) Seite 21 IV/I V(25)°C = f(T j); I F = 10 mA Chromaticity Coordinate Shift 7) page 21 Farbortverschiebung 7) Seite 21 ΔCx, ΔCy = f(Tj); I F = 10 mA LCB M67S CoD blue SB -40 -20 0 20 40 60 80 100 Tj [°C] -0,2 0,0 0,2 0,4 ΔVF [V] : CoD blue LCB M67S CoD blue SB -40 -20 0 20 40 60 80 100 Tj [°C] 0,0 0,2 0,4 0,6 0,8 1,0 1,2 1,4 Iv I v(25 °C ) : CoD blue LCB M67S CoD blue SB -40 -20 0 20 40 60 80 100 Tj [°C] -0,02 -0,01 0,00 0,01 0,02 ΔCx ΔCy : Cx : Cy

Version 2.3 LCB M67S CoD blue Cx=0.19 / Cy=0.19 2015-08-20 11 Max. Permissible Forward Current Max. zulässiger Durchlassstrom IF = f (T) Permissible Pulse Handling Capability Zulässige Impulsbelastbarkeit I F = f(t p) D: Duty cycle, T S = 25 °C Permissible Pulse Handling Capability Zulässige Impulsbelastbarkeit I F = f(t p) D: Duty cycle, T S = 85 °C temp. solder point 40200 T S 1008060 ˚C T IF mA OHL10266 temp. ambientTA TA TS OHL01983 10-5 pt FI 10-4 10-3 10-2 10-1 100 1010 A 210s D tP T Pt IF 0.01 0.05 0.2 0.1 0.005 0.02 0.5 D = 0.02 0.04 0.06 0.08 0.10 0.12 0.16 OHL01984 10-5 pt FI 10-4 10-3 10-2 10-1 100 1010 A 210s D tP T Pt IF 0.01 0.05 0.2 0.1 0.005 0.02 0.5 D = 0.02 0.04 0.06 0.08 0.10 0.12 0.16

Version 2.3 LCB M67S CoD blue Cx=0.19 / Cy=0.19 Package Outline 9) page 21 Maßzeichnung 9) Seite 21 Approximate Weight: 7 mg Gewicht: 7 mg Mark: bevelled edge (Cathode) Markierung: abgeschrägte Ecke (Kathode) Corrosion robustness: Test conditions: 40 °C / 90 % rh / 15 ppm H 2S / 336 h = Stricter than IEC 60068-2-43 (H 2S) [25°C / 75 % rh / 10 ppm H 2S / 21 days] = Regarding relevant gas (H 2S) stricter than EN 60068-2-60 (method 4) [25 °C / 75 % rh / 200 ppb SO 2, 200 ppb NO 2, 10 ppb Cl 2 / 21 days] Korrosionsfestigkeit: Test Kondition: 40°C / 90 % rh / 15 ppm H 2S / 336 h = Besser als IEC 60068-2-43 (H 2S) [25°C / 75 % rh / 10 ppm H 2S / 21 Tage] = Bezogen auf das Gas (H 2S) besser als EN 60068-2-60 (method 4) [25°C / 75 % rh / 200ppb SO 2, 200ppb NO 2, 10ppb Cl 2 / 21 Tage]

Version 2.3 LCB M67S CoD blue Cx=0.19 / Cy=0.19 2015-08-20 13 Recommended Solder Pad 9) page 21 Reflow soldering Empfohlenes Lötpaddesign 9) Seite 21 Reflow-Löten Note: For superior solder joint connectivity results we recommend soldering under standard nitrogen atmosphere. Package not suitable for ultra sonic cleaning. Anm.: Um eine verbesserte Lötstellenkontaktierung zu erreichen, empfehlen wir, unter Standard- Stickstoffatmosphäre zu löten. Das Gehäuse ist für Ultraschallreinigung nicht geeignet. OHLPY978 Paddesign for improved heat dissipation Cu-area > 16 mm Cu-Fläche > 16 mm Wärmeableitung Padgeometrie für verbesserte Lötstopplack Solder resist 0.8 (0.031) 2.8 (0.110) 1 (0.039) 2.8 (0.110) 0.8 (0.031) 1 (0.039)

Version 2.3 LCB M67S CoD blue Cx=0.19 / Cy=0.19 Reflow Soldering Profile Reflow-Lötprofil Product complies to MSL Level 2 acc. to JEDEC J-STD-020D.01 00 s OHA04525 100 150 200 250 300 50 100 150 200 250 300 t T St t Pt Tp240 ˚C 217 ˚C 245 ˚C 25 ˚C L OHA04612 Profile Feature Profil-Charakteristik Ramp-up rate to preheat*) 25 °C to 150 °C 2 3 K/s Time tS TSmin to TSmax tS tL tP TL TP 100 12060 10 20 30 80 100 217 2 3 245 260 3 6 Time 25 °C to T P Time within 5 °C of the specified peak temperature TP - 5 K Ramp-down rate* TP to 100 °C All temperatures refer to the center of the package, measured on the top of the component * slope calculation DT/ Dt: Dt max. 5 s; fulfillment for the whole T-range Ramp-up rate to peak*) TSmax to T P Liquidus temperature Peak temperature Time above liquidus temperature Symbol Symbol Unit Einheit Pb-Free (SnAgCu) Assembly Minimum MaximumRecommendation K/s K/s s s s s 480

Version 2.3 LCB M67S CoD blue Cx=0.19 / Cy=0.19 2015-08-20 15 Taping 9) page 21 Gurtung 9) Seite 21 OHAY0225 1.5 (0.059) 2 (0.079) 4 (0.157) 1.55 (0.061) 4 (0.157) 3.5 (0.138) 1.75 (0.069) 8 (0.315) 2.35 (0.093) Cathode/Collector Side

Version 2.3 LCB M67S CoD blue Cx=0.19 / Cy=0.19 Tape dimensions [mm] Gurtmaße [mm] Tape dimensions in mm Reel dimensions [mm] Rollenmaße [mm] Reel dimensions in mm Tape and Reel Gurtverpackung 8 mm tape with 3000 pcs. on ∅ 180 mm reel W P0 P1 P2 D0 E F or 4 ± 0.1 A W Nmin W1 W2max 180 8 60 8.4 + 2 14.4 W F E Direction of unreeling N A OHAY0324 Label Leader: Trailer: 13.0 Direction of unreeling ±0.25 min. 160 mm * min. 400 mm * *) Dimensions acc. to IEC 60286-3; EIA 481-D

Version 2.3 LCB M67S CoD blue Cx=0.19 / Cy=0.19 2015-08-20 17 Barcode-Product-Label (BPL) Barcode-Produkt-Etikett (BPL) Dry Packing Process and Materials Trockenverpackung und Materialien Note: Moisture-sensitive product is packed in a dry bag containing desiccant and a humidity card. Regarding dry pack you will find further information in the internet and in the Short Form Catalog in chapter “Tape and Reel” under the topic “Dry Pack”. Here you will also find the normative references like JEDEC. Anm.: Feuchteempfindliche Produkte sind verpackt in einem Trockenbeutel zusammen mit einem Trockenmittel und einer Feuchteindikatorkarte. Bezüglich Trockenverpackung finden Sie weitere Hinweise im Internet und in unserem Short Form Catalog im Kapitel “Gurtung und Verpackung” unter dem Punkt “Trockenverpackung”. Hier sind Normenbezüge, unter anderem ein Auszug der JEDEC-Norm, enthalten. OHA04563 (G) GROUP: 1234567890(1T) LOT NO: (9D) D/C: 1234 (X) PROD NO:123456789 (6P) BATCH NO:1234567890 LX XXXX RoHS Compliant BIN1: XX-XX-X-XXX-X ML X Temp ST XXX °C X Pack: RXX DEMY XXX X_X123_1234.1234 X 9999(Q)QTY: Semiconductors OSRAM Opto XX-XX-X-X EXAMPLE X_X123_1234.1234 XX_X123_1234.1234 X EXAMPLEEXAMPLEEXAMPLE XXX X_X123_1234.1234 X XX-XX-X-X EXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLE XXXXXX X_X123_1234.1234 XX_X123_1234.1234 X XX-XX-X-XXX-XX-X-X EXAMPLE Pack: RXX XXX X_X123_1234.1234 X XX-XX-X-X EXAMPLE Pack: RXXPack: RXX DEMY DEMY EXAMPLE 1234 EXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLE EXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLE 1234 EXAMPLE Pack: RXX DEMY EXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLE (9D) D/C: EXAMPLEEXAMPLEEXAMPLEEXAMPLE (9D) D/C:1234 EXAMPLEEXAMPLEEXAMPLEEXAMPLE (9D) D/C: EXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLE12345678901234567890EXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLE(6P) BATCH NO:1234567890 Semiconductors EXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLE(6P) BATCH NO:(6P) BATCH NO:12345678901234567890EXAMPLE SemiconductorsSemiconductors OSRAM OptoOSRAM Opto EXAMPLEEXAMPLE1234567890 X_X123_1234.1234 X Pack: RXX DEMY X_X123_1234.1234 X (9D) D/C:1234(9D) D/C: 1234567890(6P) BATCH NO:1234567890 OSRAM Opto XXX X_X123_1234.1234 X XX-XX-X-X Pack: RXX DEMY Semiconductors OHA00539 OSRAM Moisture-sensitive label or print Barcode label Desiccant Humidity indicator Barcode label OSRAM Please check the HIC immidiately after bag opening. Discard if circles overrun. Avoid metal contact. WET Do not eat. Comparatorcheck dot parts still adequately dry. examine units, if necessary examine units, if necessary 15% 10%bake units bake units If wet, change desiccant If wet, Humidity Indicator MIL-I-8835 If wet, Moisture Level 3 Floor time 168 Hours Moisture Level 6 Floor time 6 Hours a) Humidity Indicator Card is > 10% when read at 23 ˚C ± 5 ˚C, or reflow, vapor-phase reflow, or equivalent processing (peak package2. After this bag is opened, devices that will be subjected to infrared 1. Shelf life in sealed bag: 24 months at < 40 ˚C and < 90% relative humidity (RH). Moisture Level 5a at factory conditions of (if blank, seal date is identical with date code). a) Mounted within b) Stored at body temp. 3. Devices require baking, before mounting, if: Bag seal date Moisture Level 1 Moisture Level 2 Moisture Level 2a 4. If baking is required, b) 2a or 2b is not met. Date and time opened: reference IPC/JEDEC J-STD-033 for bake procedure. Floor time see below If blank, see bar code label Floor time > 1 Year Floor time 1 Year Floor time 4 Weeks 10% RH._< Moisture Level 4 Moisture Level 5 ˚C). OPTO SEMICONDUCTORS MOISTURE SENSITIVE This bag containsCAUTION Floor time 72 Hours Floor time 48 Hours Floor time 24 Hours 30 ˚C/60% RH._< LEVEL If blank, seebar code label

Version 2.3 LCB M67S CoD blue Cx=0.19 / Cy=0.19 Transportation Packing and Materials Kartonverpackung und Materialien Dimensions of transportation box in mm Width Length Height Breite Länge Höhe 200 ± 5 195 ± 5 30 ± 5 OHA02044 PACKVAR:R077Additional TEXT P-1+Q-1Multi TOPLED Muster OSRAM OptoSemiconductors (6P) BATCH NO: (X) PROD NO: (9D) D/C: 1 1(1T) LOT NO: 210021998 123GH1234 0 2 4 5 (Q)QTY: 2000 0144 (G) GROUP:

260 C RT240 C R

220 C RML

Bin3:Bin2: Q-1-20Bin1: P-1-20 LSY T676 2 2a Temp ST R18 DEMY PACKVAR:R077Additional TEXT P-1+Q-1Multi TOPLED Muster OSRAM OptoSemiconductors (6P) BATCH NO: (X) PROD NO: (9D) D/C: 1 1(1T) LOT NO: 210021998 123GH1234 0 2 4 5 (Q)QTY: 2000 0144 (G) GROUP: Bin3:Bin2: Q-1-20Bin1: P-1-20 LSY T676 2 2a Temp ST R18 DEMY OSRAM Packing Sealing label Barcode label Moisture Level 3 Floor time 168 Hours Moisture Level 6 Floor time 6 Hours a) Humidity Indicator Card is > 10% when read at 23 ˚C ± 5 ˚C, or reflow, vapor-phase reflow, or equivalent processing (peak package2. After this bag is opened, devices that will be subjected to infrared 1. Shelf life in sealed bag: 24 months at < 40 ˚C and < 90% relative humidity (RH). Moisture Level 5a at factory conditions of (if blank, seal date is identical with date code). a) Mounted within b) Stored at body temp. 3. Devices require baking, before mounting, if: Bag seal date Moisture Level 1 Moisture Level 2 Moisture Level 2a 4. If baking is required, b) 2a or 2b is not met. Date and time opened: reference IPC/JEDEC J-STD-033 for bake procedure. Floor time see below If blank, see bar code label Floor time > 1 Year Floor time 1 Year Floor time 4 Weeks 10% RH._< Moisture Level 4 Moisture Level 5 ˚C). OPTO SEMICONDUCTORS MOISTURE SENSITIVE This bag containsCAUTION Floor time 72 Hours Floor time 48 Hours Floor time 24 Hours 30 ˚C/60% RH._< LEVEL If blank, seebar code label Barcode label

Version 2.3 LCB M67S CoD blue Cx=0.19 / Cy=0.19 2015-08-20 19 Notes Hinweise The evaluation of eye safety occurs according to the standard IEC 62471:2008 ("photobiological safety of lamps and lamp systems"). Within the risk grouping system of this CIE standard, the LED specified in this data sheet fall into the class Exempt group (exposure time 10000 s). Under real circumstances (for exposure time, eye pupils, observation distance), it is assumed that no endangerment to the eye exists from these devices. As a matter of principle, however, it should be mentioned that intense light sources have a high secondary exposure potential due to their blinding effect. As is also true when viewing other bright light sources (e.g. headlights), temporary reduction in visual acuity and afterimages can occur, leading to irritation, annoyance, visual impairment, and even accidents, depending on the situation. Die Bewertung der Augensicherheit erfolgt nach dem Standard IEC 62471:2008 ("photobiological safety of lamps and lamp systems"). Im Risikogruppensystem dieser CIE- Norm erfüllen die in diesem Datenblatt angegebenen LEDs folgende Gruppenanforderung - Exempt group (Expositionsdauer 10000 s). Unter realen Umständen (für Expositionsdauer, Augenpupille, Betrachtungsabstand) geht damit von diesen Bauelementen keinerlei Augengefährdung aus. Grundsätzlich sollte jedoch erwähnt werden, dass intensive Lichtquellen durch ihre Blendwirkung ein hohes sekundäres Gefahrenpotenzial besitzen. Nach einem Blick in eine helle Lichtquelle (z.B. Autoscheinwerfer), kann ein temporär eingeschränktes Sehvermögen oder auch Nachbilder zu Irritationen, Belästigungen, Beeinträchtigungen oder sogar Unfällen führen. For further application related informations please visit www.osram-os.com/appnotes Für weitere applikationsspezifische Informationen besuchen Sie bitte www.osram-os.com/appnotes

Version 2.3 LCB M67S CoD blue Cx=0.19 / Cy=0.19 Disclaimer Disclaimer Language english will prevail in case of any discrepancies or deviations between the two language wordings. Attention please! The information describes the type of component and shall not be considered as assured characteristics. Terms of delivery and rights to change design reserved. Due to technical requirements components may contain dangerous substances. For information on the types in question please contact our Sales Organization. If printed or downloaded, please find the latest ver sion in the Internet. Packing Please use the recycling operators known to you. We can also help you – get in touch with your nearest sales office. By agreement we will take packing material back, if it is sorted. You must bear the costs of transport. For packing material that is returned to us unsorted or which we are not obliged to accept, we shall have to invoi ce you for any costs incurred. Components used in life-support devices or systems must be expressly authorized for such purpose! Critical components* may only be used in life-support devices** or systems with the express written approval of OSRAM OS. *) A critical component is a component used in a life-support device or system whose failure can reasonably be expected to cause the failure of that life-support device or system, or to affect its safety or the effectiveness of that device or system. **) Life support devices or systems are intended (a) to be implanted in the human body, or (b) to support and/or maintain and sustain human life. If they fail, it is reasonable to assume that the health and the life of the user may be endangered. Bei abweichenden Angaben im zweisprachigen Wortlaut haben die Angaben in englischer Sprache Vorrang. Bitte beachten! Lieferbedingungen und Änderungen im Design vorbehalten. Aufgrund technischer Anforderungen können die Bauteile Gefahrstoffe enthalten. Für weitere Informationen zu gewünschten Bauteilen, wenden Sie sich bitte an unseren Vertrieb. Falls Sie dieses Datenblatt ausgedruckt oder heruntergeladen haben, finden Sie die aktuellste Version im Internet. Verpackung Benutzen Sie bitte die Ihnen bekannten Recyclingwege. Wenn diese nicht bekannt sein sollten, wenden Sie sich bitte an das nächstgelegene Vertriebsbüro. Wir nehmen das Verpackungsmaterial zurück, falls dies vereinbart wurde und das Material sortiert ist. Sie tragen die Transportkosten. Für Verpackungsmaterial, das unsortiert an uns zurückgeschickt wird oder das wir nicht annehmen müssen, stellen wir Ihnen die anfallenden Kosten in Rechnung. Bauteile, die in lebenserhaltenden Apparaten und Systemen eingesetzt werden, müssen für diese Zwecke ausdrücklich zugelassen sein! Kritische Bauteile* dürfen in lebenserhaltenden Apparaten und Systemen** nur dann eingesetzt werden, wenn ein schriftliches Einverständnis von OSRAM OS vorliegt. *) Ein kritisches Bauteil ist ein Bauteil, das in lebenserhaltenden Apparaten oder Systemen eingesetzt wird und dessen Defekt voraussichtlich zu einer Fehlfunktion dieses lebenserhaltenden Apparates oder Systems führen wird oder die Sicherheit oder Effektivität dieses Apparates oder Systems beeinträchtigt. **) Lebenserhaltende Apparate oder Systeme sind für (a) die Implantierung in den menschlichen Körper od er (b) für die Lebenserhaltung bestimmt. Falls Sie versagen, kann davon ausgegangen werden, dass die Gesundheit und das Leben des Patienten in Gefahr ist.

Version 2.3 LCB M67S CoD blue Cx=0.19 / Cy=0.19 2015-08-20 21 Glossary Glossar 1) Brightness: Brightness values are measured during a current pulse of typically 25 ms, with an internal reproducibility of ± 8 % and an expanded uncertainty of ± 11 % (acc. to GUM with a coverage factor of k = 3). 1) Helligkeit: Helligkeitswerte werden während eines Strompulses einer typischen Dauer von 25 ms, mit einer internen Reproduzierbarkeit von ± 8 % und einer erweiterten Messunsicherheit von ± 11 % gemessen (gemäß GUM mit Erweiterungsfaktor k = 3). 2) Reverse Voltage: Not designed for reverse operation. Continuous reverse voltage can cause migration and LED damage. 2) Sperrspannung: Die LED kann nicht in Sperrrichtung betrieben werden. Kontinuierlicher Rückwärtsbetrieb kann Migration und eine Beschädigung der LED zur Folge haben. 3) Chromaticity coordinate groups: Chromaticity coordinates are measured during a current pulse of typically 25 ms, with an internal reproducibility of ± 0.005 and an expanded uncertainty of ± 0.01 (acc. to GUM with a coverage factor of k = 3). 3) Farbortgruppen: Farbkoordinaten werden während eines Strompulses einer typischen Dauer von 25 ms, mit einer internen Reproduzierbarkeit von ± 0,005 und einer erweiterten Messunsicherheit von ± 0,01 gemessen (gemäß GUM mit Erweiterungsfaktor k = 3). 4) Forward Voltage: The forward voltage is measured during a current pulse of typically 8 ms, with an internal reproducibility of ± 0.05 V and an expande d uncertainty of ± 0.1 V (acc. to GUM with a coverage factor of k = 3). 4) Durchlassspannung: Vorwärtsspannungen werden während eines Strompulses einer typischen Dauer von 8 ms, mit einer internen Reproduzierbarkeit von ± 0,05 V und einer erweiterten Messunsicherheit von ± 0,1 V gemessen (gemäß GUM mit Erweiterungsfaktor k = 3). 5) Thermal Resistance: RthJA results from mounting on PC board FR 4 (pad size 16mm² per pad) 5) Wärmewiderstand: RthJA ergibt sich bei Montage auf PC-Board FR 4 (Padgröße 16mm² je pad) 6) Thermal Resistance: Rth max is based on statistic values (6σ). 6) Wärmewiderstand: Rth max basiert auf statistischen Werten (6σ). 7) Typical Values: Due to the special conditions of the manufacturing processes of LED, the typical data or calculated correlations of technical parameters can only reflect statistical figures. These do not necessarily correspond to the actual parameters of each single product, which could differ from the typical data and calculated correlations or the typi cal characteristic line. If requested, e.g. because of technical improvements, these typ. data will be changed without any further notice. 7) Typische Werte: Wegen der besonderen Prozessbedingungen bei der Herstellung von LED können typische oder abgeleitete technische Parameter nur aufgrund statistischer Werte wiedergegeben werden. Diese stimmen nicht notwendigerweise mit den Werten jedes einzelnen Produktes überein, dessen Werte sich von typischen und abgeleiteten Werten oder typischen Kennlinien unterscheiden können. Falls erforderlich, z.B. aufgrund technischer Verbesserungen, werden diese typischen Werte ohne weitere Ankündigung geändert. 8) Characteristic curve: In the range where the line of the graph is broken, you must expect higher differences between single LEDs within one packing unit. 8) Kennlinien: Im gestrichelten Bereich der Kennlinien muss mit erhöhten Abweichungen zwischen Leuchtdioden innerhalb einer Verpackungseinheit gerechnet werden. 9) Tolerance of Measure: Unless otherwise noted in drawing, tolerances are specified with ±0.1 and dimensions are specified in mm. 9) Maßtoleranz: Wenn in der Zeichnung nicht anders angegeben, gilt eine Toleranz von ±0,1. Maße werden in mm angegeben.

Version 2.3 LCB M67S CoD blue Cx=0.19 / Cy=0.19 Published by OSRAM Opto Semiconductors GmbH Leibnizstraße 4, D-93055 Regensburg www.osram-os.com © All Rights Reserved.