Version 1.2 LCB M67C - CoD blue Cx=0.2 / Cy=0.3 Features: Besondere Merkmale:
- Package: white SMT package, colored diffused resin
- Gehäusetyp: weißes SMT Gehäuse, farbiger diffuser Verguss
- Technology: InGaN • Technologie: InGaN
- Viewing angle at 50 % I V: 120° (Lambertian Emitter)
- Abstrahlwinkel bei 50 % I V: 120° (Lambertscher Strahler)
- Color: Cx = 0.20, Cy = 0.30 acc. to CIE 1931 (color on demand blue)
- Farbe: Cx = 0.20, Cy = 0.30 nach CIE 1931 (color on demand blau)
- Corrosion Robustness: Improved corrosion robustness
- Korrosionsstabilität: Verbesserte Korrosionsstabilität Applications Anwendungen
- Automotive Interior Lighting • Automobilbeleuchtung i nnen
- Dashboard Backlighting • Instrumentenbeleuchtung
- Pushbuttons and Switches • Schalter und Taster
- Signal and Symbol Luminary • Signal- und Symbolleuch ten
Version 1.2 LCB M67C - CoD blue Cx=0.2 / Cy=0.3
Ordering Information
Type: Luminous Intensity 1) page 22 Ordering Code Typ: Lichtstärke 1) Seite 22 Bestellnummer IF = 10 mA IV [mcd] LCB M67C-R2S2-2J8L-1 140 ... 280 Q65111A4881 Note: The above Type Numbers represent the order gr oups which include only a few brightness groups (see page 5). Only one group will be shipped on each packing unit (there will be no mixing of two groups on each packing unit). E. g. LCB M67C-R2S2-2J8L-1 means t hat only one group R2, S1, S2 will be shippable for any packing unit. In order to ensure avail ability, single brightness groups will not be ordera ble. In a similar manner for colors where color chromaticity coordinate groups are measured and binned, single group s will be shipped on any one packing unit. LCB M67C-R2S2-2J8L-1 means that the device wil l be shipped within the specified limits. In order t o ensure availability, single color chromaticity groups groups will not be orderable. In a similar manner for colors where forward voltage grou ps are measured and binned, single forward voltage group s will be shipped on any packing unit. E. g. LCB M67C-R2S2-2J8L-1 means that only one forward voltage group 26,86,E6 will be shippable. In o rder to ensure availability, single forward voltage groups will not be orderable (see page 5). Anm.: Die oben genannten Typbezeichnungen umfassen di e bestellbaren Selektionen. Diese bestehen aus wenige n Helligkeitsgruppen (siehe Seite 5). Es wird nur eine einzige Helligkeitsgruppe pro Verpackun gseinheit geliefert. Z. B. LCB M67C-R2S2-2J8L-1 bede utet, dass in einer Verpackungseinheit nur eine der Helligkeitsgruppen R2, S1, S2 enhalten i st. Um die Liefersicherheit zu gewährleisten, können ei nzelne Helligkeitsgruppen nicht bestellt werden. Gleiches gilt für die Farben, bei denen Farbortgruppe n gemessen und gruppiert werden. Pro Verpackungseinheit wird nur eine Farbortgruppe geliefert. Z.B. LCB M67C-R2S2-2J8L-1 bedeutet, dass in einer Ver packungseinheit nur eine der Farbortgruppen enthalten i st. LCB M67C-R2S2-2J8L-1 bedeutet, dass das Bauteil innerhalb der spezifizierten Grenzen geliefert wird. Um die Liefersicherheit zu gewährleisten, können einzelne Farbortgruppen nicht bestellt werden. Gleiches gilt für die LEDs, bei denen die Durchlassspannu ngsgruppen gemessen und gruppiert werden. Pro Verpack ungseinheit wird nur eine Durchlassspannungsgruppe geliefert. Z. B. LCB M67C-R2S 2-2J8L-1 bedeutet, dass nach Durchlassspannungsgruppen gruppiert wird. In einer Verpackungseinheit ist nur eine der Durchlassspannungsgru ppen 26,86,E6 enthalten (siehe Seite 5). Um die Lief ersicherheit zu gewährleisten, können einzelne Durchlassspannungsgruppen nicht direkt bestel lt werden.
Version 1.2 LCB M67C - CoD blue Cx=0.2 / Cy=0.3 2014-10-30 3 Maximum Ratings Grenzwerte Parameter Symbol Values Unit Bezeichnung Symbol Werte Einheit Operating temperature range Betriebstemperatur Top -40 ... 100 °C Storage temperature range Lagertemperatur Tstg -40 ... 100 °C Junction temperature Sperrschichttemperatur Tj 110 °C Forward current Durchlassstrom (TS = 25 °C) IF 20 mA Surge current Stoßstrom IFM 300 mA Reverse voltage 2) page 22 Sperrspannung 2) Seite 22 (TS = 25 °C) VR 5 V ESD withstand voltage ESD Festigkeit (acc. to ANSI/ESDA/JEDEC JS-001 - HBM, Class VESD 2 kV
Version 1.2 LCB M67C - CoD blue Cx=0.2 / Cy=0.3 Characteristics (TS = 25 °C; I F = 10 mA) Kennwerte Parameter Symbol Values Unit Bezeichnung Symbol Werte Einheit Chromaticity coordinates acc. to CIE 1931 3) page 22 Farbkoordinaten nach CIE 1931 3) Seite 22 (typ.) (typ.) Cx Cy 0.2 0.3 Viewing angle at 50 % I V Abstrahlwinkel bei 50 % I V (typ.) 2ϕ 120 ° Forward voltage 4) page 22 Durchlassspannung 4) Seite 22 (min.) (typ.) (max.) VF VF VF 2.80 3.00 3.70 V V V Reverse current Sperrstrom (VR = 5 V) (typ.) (max.) IR IR 0.01 µA µA Real thermal resistance junction / ambient 5) page 22 , 6) page 22 Realer Wärmewiderstand Sperrschicht / Umgebung 5) Seite 22 , 6) Seite 22 (max.) R th JA real 530 K/W Real thermal resistance junction / solder point 6) page 22 Realer Wärmewiderstand Sperrschicht / Lötpad 6) Seite 22 (max.) R th JS real 280 K/W Note: Individual forward voltage groups see next pa ge Anm.: Durchlassspannungsgruppen siehe nächste Seite
Version 1.2 LCB M67C - CoD blue Cx=0.2 / Cy=0.3 2014-10-30 5 Brightness Groups Helligkeitsgruppen Forward Voltage Groups 4) page 22 Durchlassspannungsgruppen 4) Seite 22 Group Luminous Intensity 1) page 22 Luminous Intensity 1) page 22 Luminous Flux 7) page 22 Gruppe Lichtstärke 1) Seite 22 Lichtstärke 1) Seite 22 Lichtstrom 7) Seite 22 (min.) Iv [mcd] (max.) Iv [mcd] (typ.) ΦV [mlm] R2 140 180 480 S1 180 224 610 S2 224 280 760 Note: The standard shipping format for serial types inclu des either a lower family group, an upper family group or a grouping of all individual brightness groups of only a few brightness groups. Individual brightness g roups cannot be ordered. Anm.: Die Standardlieferform von Serientypen beinhalte t entweder eine untere Familiengruppe, eine obere Fa miliengruppe oder eine Sammelgruppe, die aus nur wenigen Helligkeitsgruppen besteht. Einzelne Hel ligkeitsgruppen sind nicht bestellbar. Group Gruppe (min.) VF [V] (max.) VF [V] 26 2.80 3.10 86 3.10 3.40 E6 3.40 3.70
Version 1.2 LCB M67C - CoD blue Cx=0.2 / Cy=0.3 Color Chromaticity Groups 3) page 22 Farbortgruppen 3) Seite 22 Chromaticity Coordinate Groups 3) page 22 Farbortgruppen 3) Seite 22 Group Gruppe Cx Cy Group Gruppe Cx Cy Group Gruppe Cx Cy OHA04401 520 530 540 550 560 570 580 590 600 610 620 630 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 510 500 490 450 Cx Cy Cx E 480 460 470 Cy 0.16 2K 2J 3L 3K 0.17 0.18 0.19 0.20 0.21 0.22 0.21 0.22 0.23 0.24 0.25 0.26 0.27 0.28 0.29 0.30 0.31 0.32 0.33
Version 1.2 LCB M67C - CoD blue Cx=0.2 / Cy=0.3 2014-10-30 7 Group Gruppe Cx Cy Group Gruppe Cx Cy Group Gruppe Cx Cy
Version 1.2 LCB M67C - CoD blue Cx=0.2 / Cy=0.3 Group Name on Label Gruppenbezeichnung auf Etikett Example: R2-2J-26 Beispiel: R2-2J-26 Brightness Helligkeit Chromaticity Coordinate Farbort Forward Voltage Durchlassspannung R2 2J 26 Note: No packing unit / tape ever contains more than on e group for each selection. Anm.: In einer Verpackungseinheit / Gurt ist immer nur eine Gruppe für jede Selektion enthalten.
Version 1.2 LCB M67C - CoD blue Cx=0.2 / Cy=0.3 2014-10-30 9 Relative Spectral Emission - V(λ) = Standard eye re sponse curve 7) page 22 Relative spektrale Emission - V(λ) = spektrale Auge nempfindlichkeit 7) Seite 22 Irel = f (λ); T S = 25 °C; I F = 10 mA Radiation Characteristics 7) page 22 Abstrahlcharakteristik 7) Seite 22 Irel = f (ϕ); T S = 25 °C LCB M67C 350 400 450 500 550 600 650 700 750 800 λ [nm] 0,0 0,2 0,4 0,6 0,8 1,0 Ire l : Co D b lu e : Vλ 0.2 0.4 1.0 0.8 0.6 ϕ 1.0 0.8 0.6 0.4 50˚ 60˚ 70˚ 80˚ 90˚ 100˚
Version 1.2 LCB M67C - CoD blue Cx=0.2 / Cy=0.3 Forward Current 7) page 22 Durchlassstrom 7) Seite 22 IF = f (V F); T S = 25 °C Relative Luminous Intensity 7) page 22 , 8) page 22 Relative Lichtstärke 7) Seite 22 , 8) Seite 22 IV/I V(10 mA) = f(I F); T S = 25 °C Chromaticity Coordinate Shift 7) page 22 Farbortverschiebung 7) Seite 22 ΔCx, ΔCy = f(I F); T S = 25 °C VF [V] ΙF [mA] LCB M67C 2 3 4 5 10 20 30 40 50 100 IF [mA] 0,2 0,3 0,4 0,5 10 IV I V(10 mA ) LC B M67C 20 40 60 80 10 0 IF [mA] -0,03 -0,02 -0,01 0,00 0,01 0,02 0,03 ∆Cx ∆Cy : ∆C x : ∆C y Measured for K Colorbins
Version 1.2 LCB M67C - CoD blue Cx=0.2 / Cy=0.3 2014-10-30 11 Relative Forward Voltage 7) page 22 Relative Vorwärtsspannung 7) Seite 22 ΔV F = V F - V F(25 °C) = f(T j); I F = 10 mA Relative Luminous Intensity 7) page 22 Relative Lichtstärke 7) Seite 22 IV/I V(25)°C = f(T j); I F = 10 mA Chromaticity Coordinate Shift 7) page 22 Farbortverschiebung 7) Seite 22 ΔCx, ΔCy = f(Tj); I F = 10 mA -40 -20 0 20 40 60 80 100 120 Tj [°C] -0,20 -0,15 -0,10 -0,05 0,00 0,05 0,10 0,15 0,20 0,25 0,30 VF-VF (25°C) [V] LCB M67C -40 -20 0 20 40 60 80 100 120 Tj [ °C] 0,0 0,2 0,4 0,6 0,8 1,0 1,2 1,4 Iv I v(25 °C ) LC B M67C -40 -20 0 20 40 60 80 100 120 Tj [°C ] -0,03 -0,02 -0,01 0,00 0,01 0,02 0,03 ∆Cx ∆Cy : ∆ C x : ∆ C y Measured for K Colorbins
Version 1.2 LCB M67C - CoD blue Cx=0.2 / Cy=0.3 Max. Permissible Forward Current Max. zulässiger Durchlassstrom IF = f (T) Permissible Pulse Handling Capability Zulässige Impulsbelastbarkeit I F = f(t p) D: Duty cycle, T S = 25 °C Permissible Pulse Handling Capability Zulässige Impulsbelastbarkeit I F = f(t p) D: Duty cycle, T S = 85 °C temp. solder point 40200 T S 1008060 ˚C T IF mA OHL01850 temp. ambientTA TA TS OHL01977 10-5 pt FI 10-4 10-3 10-2 10-1 100 1010 A 210 s D tP T Pt IF 0.01 0.05 0.2 0.1 0.005 0.02 0.5 D = 0.05 0.10 0.15 0.20 0.25 0.35 OHL01977 10-5 pt FI 10-4 10-3 10-2 10-1 100 1010 A 210 s D tP T Pt IF 0.01 0.05 0.2 0.1 0.005 0.02 0.5 D = 0.05 0.10 0.15 0.20 0.25 0.35
Version 1.2 LCB M67C - CoD blue Cx=0.2 / Cy=0.3 2014-10-30 13 Package Outline 9) page 22 Maßzeichnung 9) Seite 22 Approximate Weight: 7 mg Gewicht: 7 mg Mark: bevelled edge (Cathode) Markierung: abgeschrägte Ecke (Kathode) Corrosion robustness: Test conditions: 40 °C / 90 % rh / 15 ppm H 2S / 336 h = Stricter than IEC 60068-2-43 (H 2S) [25°C / 75 % rh / 10 ppm H 2S / 21 days] = Regarding relevant gas (H 2S) stricter than EN 60068-2-60 (method 4) [25 °C / 75 % rh / 200 ppb SO 2, 200 ppb NO 2, 10 ppb Cl 2 / 21 days] Korrosionsfestigkeit: Test Kondition: 40°C / 90 % rh / 15 ppm H 2S / 336 h = Besser als IEC 60068-2-43 (H 2S) [25°C / 75 % rh / 10 ppm H 2S / 21 Tage] = Bezogen auf das Gas (H 2S) besser als EN 60068-2-60 (method 4) [25°C / 75 % rh / 200ppb SO 2, 200ppb NO 2, 10ppb Cl 2 / 21 Tage]
Version 1.2 LCB M67C - CoD blue Cx=0.2 / Cy=0.3 Recommended Solder Pad 9) page 22 Reflow soldering Empfohlenes Lötpaddesign 9) Seite 22 Reflow-Löten Note: For superior solder joint connectivity results we recommend soldering under standard nitrogen atmosphere. Package not suitable for ultra sonic cleaning. Anm.: Um eine verbesserte Lötstellenkontaktierung zu erreichen, empfehlen wir, unter Standard- Stickstoffatmosphäre zu löten. Das Gehäuse ist für Ultraschallreinigung nicht geeignet. OHLPY978 Paddesign for improved heat dissipation Cu-area > 16 mm Cu-Fläche > 16 mm Wärmeableitung Padgeometrie für verbesserte Lötstopplack Solder resist 0.8 (0.031) 2.8 (0.110) 1 (0.039) 2.8 (0.110) 0.8 (0.031) 1 (0.039)
Version 1.2 LCB M67C - CoD blue Cx=0.2 / Cy=0.3 2014-10-30 15 Reflow Soldering Profile Reflow-Lötprofil Preconditioning: JEDEC Level 2 acc. to JEDEC J-STD- 020D.01 00 s OHA04525 100 150 200 250 300 50 100 150 200 250 300 t T St t Pt Tp240 ˚C 217 ˚C 245 ˚C 25 ˚C L OHA04612 Profile Feature Profil-Charakteristik Ramp-up rate to preheat*) 25 °C to 150 °C 2 3 K/s Time tS TSmin to TSmax tS tL tP TL TP 100 12060 10 20 30 80 100 217 2 3 245 260 3 6 Time 25 °C to T P Time within 5 °C of the specified peak temperature TP - 5 K Ramp-down rate* TP to 100 °C All temperatures refer to the center of the package, measured on the top of the component * slope calculation DT/ Dt: Dt max. 5 s; fulfillment for the whole T-range Ramp-up rate to peak*) TSmax to T P Liquidus temperature Peak temperature Time above liquidus temperature Symbol Symbol Unit Einheit Pb-Free (SnAgCu) Assembly Minimum MaximumRecommendation K/s K/s s s s s 480
Version 1.2 LCB M67C - CoD blue Cx=0.2 / Cy=0.3 Taping 9) page 22 Gurtung 9) Seite 22 OHAY0225 1.5 (0.059) 2 (0.079) 4 (0.157) 1.55 (0.061) 4 (0.157) 3.5 (0.138) 1.75 (0.069) 8 (0.315) 2.35 (0.093) Cathode/Collector Side
Version 1.2 LCB M67C - CoD blue Cx=0.2 / Cy=0.3 2014-10-30 17 Tape dimensions in mm Tape dimensions in mm Reel dimensions in mm Reel dimensions in mm Tape and Reel Gurtverpackung 8 mm tape with 3000 pcs. on ∅ 180 mm reel W P0 P1 P2 D0 E F or 4 ± 0.1 A W Nmin W1 W2max 180 8 60 8.4 + 2 14.4 W F E Direction of unreeling N A OHAY0324 Label Leader: Trailer: 13.0 Direction of unreeling ±0.25 min. 160 mm * min. 400 mm * *) Dimensions acc. to IEC 60286-3; EIA 481-D
Version 1.2 LCB M67C - CoD blue Cx=0.2 / Cy=0.3 Barcode-Product-Label (BPL) Barcode-Produkt-Etikett (BPL) Dry Packing Process and Materials Trockenverpackung und Materialien Note: Moisture-sensitive product is packed in a dry bag containing desiccant and a humidity card. Regarding dry pack you will find further informatio n in the internet and in the Short Form Catalog in chapter “Tape and Reel” under the topic “Dry Pack”. Here you will also find the normative references like JEDEC. Anm.: Feuchteempfindliche Produkte sind verpackt in einem Trockenbeutel zusammen mit einem Trockenmittel und einer Feuchteindikatorkarte. Bezüglich Trockenverpackung finden Sie weitere Hinw eise im Internet und in unserem Short Form Catalog im Kapitel “Gurtung und Verpackung” unter d em Punkt “Trockenverpackung”. Hier sind Normenbezüge, unter anderem ein Auszug der JEDEC-No rm, enthalten. OHA04563 (G) GROUP: 1234567890(1T) LOT NO: (9D) D/C: 1234 (X) PROD NO:123456789 (6P) BATCH NO:1234567890 LX XXXX RoHS Compliant BIN1: XX-XX-X-XXX-X ML X Temp ST XXX °C X Pack: RXX DEMY XXX X_X123_1234.1234 X 9999(Q)QTY: Semiconductors OSRAM Opto XX-XX-X-X EXAMPLE X_X123_1234.1234 XX_X123_1234.1234 X EXAMPLEEXAMPLEEXAMPLE XXXXXX X_X123_1234.1234 XX_X123_1234.1234 X XX-XX-X-XXX-XX-X-X EXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLE XXXXXX X_X123_1234.1234 XX_X123_1234.1234 X XX-XX-X-XXX-XX-X-X EXAMPLE Pack: RXX DEMY XXX X_X123_1234.1234 XX_X123_1234.1234 X XX-XX-X-X EXAMPLE Pack: RXXPack: RXX DEMY DEMY EXAMPLE 12341234 EXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLE EXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLE 12341234 EXAMPLE Pack: RXXPack: RXX DEMY DEMY EXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLE (9D) D/C:(9D) D/C: EXAMPLEEXAMPLEEXAMPLEEXAMPLE (9D) D/C:12341234 EXAMPLEEXAMPLEEXAMPLEEXAMPLE (9D) D/C:(9D) D/C: EXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLE12345678901234567890EXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLE(6P) BATCH NO:(6P) BATCH NO:12345678901234567890 SemiconductorsSemiconductors EXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLEEXAMPLE(6P) BATCH NO:(6P) BATCH NO:12345678901234567890EXAMPLE SemiconductorsSemiconductors OSRAM OptoOSRAM Opto EXAMPLEEXAMPLE12345678901234567890 X_X123_1234.1234 X Pack: RXX DEMY X_X123_1234.1234 X (9D) D/C:1234(9D) D/C: 1234567890(6P) BATCH NO:1234567890 OSRAM Opto XXX X_X123_1234.1234 X XX-XX-X-X Pack: RXX DEMY Semiconductors OHA00539 OSRAM Moisture-sensitive label or print Barcode label Desiccant Humidity indicator Barcode label OSRAM Please check the HIC immidiately after bag opening. Discard if circles overrun. Avoid metal contact. WET Do not eat. Comparatorcheck dot parts still adequately dry. examine units, if necessary examine units, if necessary 15% 10%bake units bake units If wet, change desiccant If wet, Humidity Indicator MIL-I-8835 If wet, Moisture Level 3 Floor time 168 Hours Moisture Level 6 Floor time 6 Hours a) Humidity Indicator Card is > 10% when read at 23 ˚C ± 5 ˚C, or reflow, vapor-phase reflow, or equivalent processing (peak package2. After this bag is opened, devices that will be subjected to infrared 1. Shelf life in sealed bag: 24 months at < 40 ˚C and < 90% relative humidity (RH). Moisture Level 5a at factory conditions of (if blank, seal date is identical with date code). a) Mounted within b) Stored at body temp. 3. Devices require baking, before mounting, if: Bag seal date Moisture Level 1Moisture Level 2Moisture Level 2a 4. If baking is required, b) 2a or 2b is not met. Date and time opened: reference IPC/JEDEC J-STD-033 for bake procedure. Floor time see below If blank, see bar code label Floor time > 1 YearFloor time 1 YearFloor time 4 Weeks 10% RH._< Moisture Level 4Moisture Level 5 ˚C). OPTO SEMICONDUCTORS MOISTURE SENSITIVE This bag containsCAUTION Floor time 72 HoursFloor time 48 HoursFloor time 24 Hours 30 ˚C/60% RH. LEVEL If blank, seebar code label
Version 1.2 LCB M67C - CoD blue Cx=0.2 / Cy=0.3 2014-10-30 19 Transportation Packing and Materials Kartonverpackung und Materialien Dimensions of transportation box in mm Width / Breite Length / Länge Height / Höhe 200 ± 5 195 ± 5 30 ± 5 OHA02044 PACKVAR:R077Additional TEXT P-1+Q-1Multi TOPLED Muster OSRAM OptoSemiconductors (6P) BATCH NO: (X) PROD NO: (9D) D/C: 11(1T) LOT NO: 210021998 123GH1234 0 24 5 (Q)QTY: 2000 0144 (G) GROUP:
260 C RT240 C R
220 C RML
Bin3:Bin2: Q-1-20Bin1: P-1-20 LSY T676 22a Temp ST R18 DEMY PACKVAR:R077Additional TEXT P-1+Q-1Multi TOPLED Muster OSRAM OptoSemiconductors (6P) BATCH NO: (X) PROD NO: (9D) D/C: 1 1(1T) LOT NO: 210021998 123GH1234 0 2 4 5 (Q)QTY: 2000 0144 (G) GROUP: Bin3:Bin2: Q-1-20Bin1: P-1-20 LSY T676 22a Temp ST R18 DEMY OSRAM Packing Sealing label Barcode label Moisture Level 3 Floor time 168 Hours Moisture Level 6 Floor time 6 Hours a) Humidity Indicator Card is > 10% when read at 23 ˚C ± 5 ˚C, or reflow, vapor-phase reflow, or equivalent processing (peak package2. After this bag is opened, devices that will be subjected to infrared 1. Shelf life in sealed bag: 24 months at < 40 ˚C and < 90% relative humidity (RH). Moisture Level 5a at factory conditions of (if blank, seal date is identical with date code). a) Mounted within b) Stored at body temp. 3. Devices require baking, before mounting, if: Bag seal date Moisture Level 1Moisture Level 2Moisture Level 2a 4. If baking is required, b) 2a or 2b is not met. Date and time opened: reference IPC/JEDEC J-STD-033 for bake procedure. Floor time see below If blank, see bar code label Floor time > 1 YearFloor time 1 YearFloor time 4 Weeks 10% RH._< Moisture Level 4Moisture Level 5 ˚C). OPTO SEMICONDUCTORS MOISTURE SENSITIVE This bag containsCAUTION Floor time 72 HoursFloor time 48 HoursFloor time 24 Hours 30 ˚C/60% RH. LEVEL If blank, seebar code label Barcode label
Version 1.2 LCB M67C - CoD blue Cx=0.2 / Cy=0.3 Notes Hinweise The evaluation of eye safety occurs according to the standard IEC 62471:2008 ("photobiological safety of lamps and lamp systems"). Within the risk grouping system of this CIE standard, the LED specified in this data sheet fall into the class Exempt group (exposure time 10000 s). Under real circumstances (for exposure time, eye pupils, observation distance), it is assumed that no endangerment to the eye exists from these devices. As a matter of principle, however, it should be mentioned that intense light sources have a high secondary exposure potential due to their blinding effect. As is also true when viewing other bright light sources (e.g. headlights), temporary reduction in visual acuity and afterimages can occur, leading to irritation, annoyance, visual impairment, and even accidents, depending on the situation. Die Bewertung der Augensicherheit erfolgt nach dem Standard IEC 62471:2008 ("photobiological safety of lamps and lamp systems"). Im Risikogruppensystem dieser CIE- Norm erfüllen die in diesem Datenblatt angegebenen LEDs folgende Gruppenanforderung - Exempt group (Expositionsdauer 10000 s). Unter realen Umständen (für Expositionsdauer, Augenpupille, Betrachtungsabstand) geht damit von diesen Bauelementen keinerlei Augengefährdung aus. Grundsätzlich sollte jedoch erwähnt werden, dass intensive Lichtquellen durch ihre Blendwirkung ein hohes sekundäres Gefahrenpotenzial besitzen. Nach einem Blick in eine helle Lichtquelle (z.B. Autoscheinwerfer), kann ein temporär eingeschränktes Sehvermögen oder auch Nachbilder zu Irritationen, Belästigungen, Beeinträchtigungen oder sogar Unfällen führen. For further application related informations please visit www.osram-os.com/appnotes Für weitere applikationsspezifische Informationen besuchen Sie bitte www.osram-os.com/appnotes
Version 1.2 LCB M67C - CoD blue Cx=0.2 / Cy=0.3 2014-10-30 21 Disclaimer Disclaimer Attention please! The information describes the type of component and shall not be considered as assured characteristics. Terms of delivery and rights to change design reserved. Due to technical requirements components may contain dangerous substances. For information on the types in question please con tact our Sales Organization. If printed or downloaded, please find the latest version in the Internet. Packing Please use the recycling operators known to you. We can also help you – get in touch with your nearest sales office. By agreement we will take packing material back, if it is sorted. You must bear the costs of transport. For packing material that is returned to us unsorted or which we are not obliged to accept, we shall have to invo ice you for any costs incurred. Components used in life-support devices or systems must be expressly authorized for such purpose! Critical components* may only be used in life-suppo rt devices** or systems with the express written appro val of OSRAM OS. *) A critical component is a component used in a life-support device or system whose failure can reasonably be expected to cause the failure of that life-support device or system, or to affect its safety or the effectiveness of that device or system. **) Life support devices or systems are intended (a) to be implanted in the human body, or (b) to support and/ or maintain and sustain human life. If they fail, it i s reasonable to assume that the health and the life o f the user may be endangered. Bitte beachten! Lieferbedingungen und Änderungen im Design vorbehalten. Aufgrund technischer Anforderungen können die Bauteile Gefahrstoffe enthalten. Für wei tere Informationen zu gewünschten Bauteilen, wenden Sie sich bitte an unseren Vertrieb. Falls Sie dieses Datenblatt ausgedruckt oder heruntergeladen haben, finden Sie die aktuellste Version im Internet. Verpackung Benutzen Sie bitte die Ihnen bekannten Recyclingwege. Wenn diese nicht bekannt sein sollten, wenden Sie sich bitte an das nächstgelegene Vertriebsbüro. Wir nehmen das Verpackungsmaterial zurück, falls dies vereinba rt wurde und das Material sortiert ist. Sie tragen die Transportkosten. Für Verpackungsmaterial, das unsortiert an uns zurückgeschickt wird oder das wir nicht annehmen müssen, stellen wir Ihnen die anfallenden Kosten in Rechnung. Bauteile, die in lebenserhaltenden Apparaten und Systemen eingesetzt werden, müssen für diese Zwecke ausdrücklich zugelassen sein! Kritische Bauteile* dürfen in lebenserhaltenden Apparaten und Systemen** nur dann eingesetzt werden, wenn ein schriftliches Einverständnis von OSRAM OS vorliegt. *) Ein kritisches Bauteil ist ein Bauteil, das in lebenserhaltenden Apparaten oder Systemen eingesetzt wird und dessen Defekt voraussichtlich z u einer Fehlfunktion dieses lebenserhaltenden Apparates oder Systems führen wird oder die Sicherheit oder Effektivität dieses Apparates oder Systems beeinträchtigt. **) Lebenserhaltende Apparate oder Systeme sind für (a) die Implantierung in den menschlichen Körper od er (b) für die Lebenserhaltung bestimmt. Falls Sie versagen, kann davon ausgegangen werden, dass die Gesundheit und das Leben des Patienten in Gefahr ist.
Version 1.2 LCB M67C - CoD blue Cx=0.2 / Cy=0.3 Glossary Glossar 1) Brightness: Brightness values are measured during a current pulse of typically 25 ms, with an interna l reproducibility of ± 8 % and an expanded uncertainty of ± 11 % (acc. to GUM with a coverage factor of k = 3). 1) Helligkeit: Helligkeitswerte werden während eines Strompulses einer typischen Dauer von 25 ms, mit einer internen Reproduzierbarkeit von ± 8 % und einer erweiterten Messunsicherheit von ± 11 % gemessen (gemäß GUM mit Erweiterungsfaktor k = 3). 2) Reverse Voltage: Not designed for reverse operation. Continuous reverse voltage can cause migration and LED damage. 2) Sperrspannung: Die LED kann nicht in Sperrrichtung betrieben werden. Kontinuierlicher Rückwärtsbetrieb kann Migration und eine Beschädigung der LED zur Folge haben. 3) Chromaticity coordinate groups: Chromaticity coordinates are measured during a current pulse of typically 25 ms, with an internal reproducibility o f ± 0.005 and an expanded uncertainty of ± 0.01 (acc. to GUM with a coverage factor of k = 3). 3) Farbortgruppen: Farbkoordinaten werden während eines Strompulses einer typischen Dauer von 25 ms, mit einer internen Reproduzierbarkeit von ± 0,005 und einer erweiterten Messunsicherheit von ± 0,01 gemessen (gemäß GUM mit Erweiterungsfaktor k = 3). 4) Forward Voltage: The forward voltage is measured during a current pulse of typically 8 ms, with an internal reproducibility of ± 0.05 V and an expande d uncertainty of ± 0.1 V (acc. to GUM with a coverage factor of k = 3). 4) Durchlassspannung: Vorwärtsspannungen werden während eines Strompulses einer typischen Dauer von 8 ms, mit einer internen Reproduzierbarkeit von ± 0,05 V und einer erweiterten Messunsicherheit von ± 0,1 V gemessen (gemäß GUM mit Erweiterungsfaktor k = 3). 5) Thermal Resistance: RthJA results from mounting on PC board FR 4 (pad size 16mm² per pad) 5) Wärmewiderstand: RthJA ergibt sich bei Montage auf PC-Board FR 4 (Padgröße 16mm² je pad) 6) Thermal Resistance: Rth max is based on statistic values (6σ). 6) Wärmewiderstand: Rth max basiert auf statistischen Werten (6σ). 7) Typical Values: Due to the special conditions of the manufacturing processes of LED, the typical data or calculated correlations of technical parameters can only reflect statistical figures. These do not necessarily correspond to the actual parameters of each single product, which could differ from the typical data and calculated correlations or the typical characteristic line. If requested, e.g. because of technical improvements, these typ. data will be changed without any further notice. 7) Typische Werte: Wegen der besonderen Prozessbedingungen bei der Herstellung von LED können typische oder abgeleitete technische Parameter nur aufgrund statistischer Werte wiedergegeben werden. Diese stimmen nicht notwendigerweise mit den Werten jedes einzelnen Produktes überein, dessen Werte sich von typischen und abgeleiteten Werten oder typischen Kennlinien unterscheiden können. Falls erforderlich, z.B. aufgrund technischer Verbesserungen, werden diese typischen Werte ohne weitere Ankündigung geändert. 8) Relative Brightness Curve: In the range where the line of the graph is broken, you must expect higher brightness differences between single LEDs within one packing unit. 8) Relative Helligkeitskurve: Im gestrichelten Bereich der Kennlinien muss mit erhöhten Helligkeitsunterschieden zwischen Leuchtdioden innerhalb einer Verpackungseinheit gerechnet werden. 9) Tolerance of Measure: Unless otherwise noted in drawing, tolerances are specified with ±0.1 and dimensions are specified in mm. 9) Maßtoleranz: Wenn in der Zeichnung nicht anders angegeben, gilt eine Toleranz von ±0,1. Maße werden in mm angegeben.
Version 1.2 LCB M67C - CoD blue Cx=0.2 / Cy=0.3 2014-10-30 23 Published by OSRAM Opto Semiconductors GmbH Leibnizstraße 4, D-93055 Regensburg www.osram-os.com © All Rights Reserved.