L6Q ZEMIC

Document overview

  • Manufacturer or author: Provided By www.digicamel.com(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 3

Technical content

Specifications and dimensions are subject to change without notice and do not constitute any liability whatsoever. Zemic Europe B.V. T: +31 76 50 39480 Nr. 2024.-01 L6Q Rev10 info@zemic.nl Page 1/3 www.zemiceurope.com Short Description

  • Aluminium-Alloy IP65 single point load cell Test certificate no. D09-07.06 and
  • Colourless anodized TC7969 Revision 0
  • Suitable for single and double load cell structured C of C no R60/2000-NL1-11.22 platform scales
  • Maximum platform size: 400 x 400 mm Certificate no. 11-104 Available Models Capacity Accuracy Full Article Description 50kg C3/C4 L6Q-C3/C4-50kg-3B6 100kg C3/C4/C5 L6Q-C3/C4/C5-100kg-3B6 150kg C3/C4/C5 L6Q-C3/C4/C5-150kg-3B6 200kg C3/C4/C5 L6Q-C3/C4/C5-200kg-3B6 250kg C3/C4/C5 L6Q-C3/C4/C5-250kg-3B6

Specifications and dimensions are subject to change without notice and do not constitute any liability whatsoever. Zemic Europe B.V. T: +31 76 50 39480 Nr. 2024.-01 L6Q Rev10 info@zemic.nl Page 2/3 www.zemiceurope.com Technical Specifications L6Q Accuracy Class OIML R60 C3 OIML R60 C4 OIML R60 C5 Output Sensitivity ( = FS ) mV/V 2.0 ± 0.2 Maximum Capacity ( Emax ) kg 50, 100, 150, 200, 250 100, 150, 200, 250 Max. Number of Load Cell Intervals nLC 3000 4000 5000 Ratio of min. LC Verification Interval Y = Emax / vmin 10000 15000 20000 Combined Error %FS ≤± 0.023 ≤± 0.0175 ≤± 0.0140 Creep Error (30 minutes) %FS ≤± 0.0245 ≤± 0.0184 ≤± 0.0147 Temperature Effect on Zero (ZTC) %FS/10°C ≤± 0.014 ≤± 0.012 ≤± 0.009 Temperature Effect on Sensitivity (STC) %FS/10°C ≤± 0.0175 ≤± 0.0131 ≤± 0.0105 Zero Balance %FS ≤± 2.0 Safe Overload %FS 120 Ultimate Overload %FS 150 Maximum Deflection mm 0.62 Eccentric Loading Error %Ld/cm ± 0.002 Excitation, Recommended Voltage V 5 ~ 12 Excitation, Maximum Voltage V 18 Input Resistance Ω 406 ± 6 Output Resistance Ω 350 ± 3 Insulation Resistance (50V) MΩ ≥5000 Compensated Temperature °C -10 ~ + 40 Operating Temperature °C -35 ~ + 65 Storage Temperature °C -40 ~ + 70 Load Cell Weight kg 0.64 Element Material Aluminium Ingress Protection (acc. to EN 60529) IP65 Recommended Torque on Fixation Bolts Nm M6: 10 Wiring Features: Cable type: Shielded, 6 conductor cable , conductor AWG 26 Cable diameter: Ø 5.0mm Cable length: 3m Cable jacket: PVC Shield not connected to element 6-Wire Connection Diagram Excitation (+) Sense (+) Signal (-) Sense (-) Excitation (-) Signal (+) Green Blue White Brown Black Red

Specifications and dimensions are subject to change without notice and do not constitute any liability whatsoever. Zemic Europe B.V. T: +31 76 50 39480 Nr. 2024.-01 L6Q Rev10 info@zemic.nl Page 3/3 www.zemiceurope.com Dimensions in mm Front View Top View Side View Isometric View M 0 0 M 0 0 M 0 0 M 0 0