L6P ZEMIC
Document overview
- Manufacturer or author: Provided By www.digicamel.com(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 3
Technical content
Specifications and dimensions are subject to change without notice and do not constitute any liability whatsoever. Zemic Europe B.V. T: +31 76 50 39480 Nr. 2024.01 L6P Rev9 info@zemic.nl Page 1/3 www.zemiceurope.com Short Description
- Low profile, planar beam construction load cell (IP65) Test certificate no. TC8407 Revision 0
- Anodized aluminum alloy C of C no R60/2000-NL1-13.22 Rev. 1
- Suitable for compact scales, bench scales, floor scales, patient beds, counting scales, etc.
- Simple installation and torque-free force application thanks to wing-like mounting arms Available Models Capacity Accuracy Full Article Description 22kg C3 L6P-C3-22kg-1.5P-R1S 45kg C3 L6P-C3-45kg-1.5P-R1S 75kg C3 L6P-C3-75kg-1.5P-R1S 90kg C3 L6P-C3-90kg-1.5P-R1S 110kg C3 L6P-C3-110kg-1.5P-R1S 150kg C3 (Excluded from OIML) L6P-C3-150kg-1.5P-R1S
Specifications and dimensions are subject to change without notice and do not constitute any liability whatsoever. Zemic Europe B.V. T: +31 76 50 39480 Nr. 2024.01 L6P Rev9 info@zemic.nl Page 2/3 www.zemiceurope.com Technical Specifications L6P Accuracy Class OIML R60 C3 C3 Output Sensitivity ( = FS ) mV/V 1.0 ± 0.1 1.0 ± 0.02 Maximum Capacity ( Emax ) kg 22, 45, 75, 90, 110 150 Max. Number of Load Cell Intervals nLC 3000 Ratio of min. LC Verification Interval Y = Emax / vmin 10000 Combined Error %FS ≤± 0.023 Creep Error (30 minutes) %FS ≤± 0.017 Temperature Effect on Zero (ZTC) %FS/10°C ≤± 0.019 Temperature Effect on Sensitivity (STC) %FS/10°C ≤± 0.020 Zero Balance %FS ≤± 5.0 Safe Overload %FS 150 120 Ultimate Overload %FS 300 250 Excitation, Recommended Voltage V 5 ~ 12 Excitation, Maximum Voltage V 18 Input Resistance Ω 1065 ± 15 1080 ± 50 Output Resistance Ω 1000 ± 10 Insulation Resistance (50V) MΩ ≥5000 Compensated Temperature °C -10 ~ + 40 Operating Temperature °C -35 ~ + 65 Storage Temperature °C -35 ~ + 65 Load Cell Weight kg ~0.04 - ~0.07 Element Material Aluminium Ingress Protection (acc. to EN 60529) IP65 Recommended Torque on Fixation Bolts Nm M4: 3 Wiring Features: Cable type: 4 conductor flat ribbon cable , conductor AWG 26 Cable diameter: Ø 1.2mm per conductor Cable length: 1.5m ± 0.1m Cable jacket: N/A 4-Wire Connection Diagram Excitation (+) Signal (-) Excitation (-) Signal (+) Red White Black Green
Specifications and dimensions are subject to change without notice and do not constitute any liability whatsoever. Zemic Europe B.V. T: +31 76 50 39480 Nr. 2024.01 L6P Rev9 info@zemic.nl Page 3/3 www.zemiceurope.com Dimensions in mm Top View Side View Isometric View Dimension Capacity ØD H2 H1 22kg 4.6 -- 3.31 45kg 4.6 -- 4.89 75kg 4.6 -- 6.16 90kg 4.6 -- 6.75 110kg 7.4 3.2 7.58 150kg 7.4 3.2 8.71