Specifications and dimensions are subject to change without notice and do not constitute any liability whatsoever. Zemic Europe B.V. T: +31 76 50 39480 Nr. 2023.12 L6F Rev7 info@zemic.nl Page 1/3 www.zemiceurope.com Short Description
- Aluminium-alloy IP65 single point load cell Test certificate no. D09-06.10
- Colourless anodized C of C no R60/2000-CN1-06.01
- Suitable for mobile weighing systems, floor scales, belt scales, hopper and tank scales, etc.
- Maximum platform size: o for 50kg – 200kg: 600 x 600 mm o for 250kg – 500kg: 600 x 800 mm o for 750kg – 2000kg: 1200 x 1200 mm Available Models Capacity Accuracy Full Article Description 50kg C3 L6F-C3-50kg-3B6 100kg C3 L6F-C3-100kg-3B6 150kg C3 L6F-C3-150kg-3B6 200kg C3 L6F-C3-200kg-3B6 250kg C3 L6F-C3-250kg-3B6 500kg C3 L6F-C3-500kg-3B6 750kg C3 L6F-C3-750kg-3B6(-W1) 1000kg C3 L6F-C3-1000kg-3B6 2000kg C3 L6F-C3-2000kg-3B6
Specifications and dimensions are subject to change without notice and do not constitute any liability whatsoever. Zemic Europe B.V. T: +31 76 50 39480 Nr. 2023.12 L6F Rev7 info@zemic.nl Page 2/3 www.zemiceurope.com Technical Specifications L6F Accuracy Class OIML R60 C3 Output Sensitivity ( = FS ) mV/V 2.0 ± 0.2 Maximum Capacity ( Emax ) kg 50, 100, 150, 200, 250, 500, 750, 1000, 2000 Max. Number of Load Cell Intervals nLC 3000 Ratio of min. LC Verification Interval Y = Emax / vmin 7000 Combined Error %FS ≤± 0.02 Creep Error (30 minutes) %FS ≤± 0.0167 Temperature Effect on Zero (ZTC) %FS/10°C ≤± 0.02 Temperature Effect on Sensitivity (STC) %FS/10°C ≤± 0.0175 Zero Balance %FS ≤± 2.0 Safe Overload %FS 120 Ultimate Overload %FS 150 Maximum Deflection mm 50kg: ~0.21 250kg: ~0.34 2t: 0.4 ~ 0.5 Eccentric Loading Error %Ld/cm ± 0.002 Excitation, Recommended Voltage V 5 ~ 12 Excitation, Maximum Voltage V 18 Input Resistance Ω 406 ± 6 Output Resistance Ω 350 ± 3 Insulation Resistance (50V) MΩ ≥5000 Compensated Temperature °C -10 ~ + 40 Operating Temperature °C -35 ~ + 65 Storage Temperature °C -40 ~ + 70 Load Cell Weight kg 50kg - 200kg: ~1.1 250kg - 500kg: 1.8 750kg - 2t: 3.7 Element Material Aluminium Ingress Protection (acc. to EN 60529) IP65 Recommended Torque on Fixation Bolts Nm M12: 100 M16: 160 Wiring Features: Cable type: Shielded, 6 conductor cable , conductor AWG 24 Cable diameter: Ø 6.2mm Cable length: 3.0m Cable jacket: PVC Shield not connected to element 6-Wire Connection Diagram Excitation (+) Sense (+) Signal (-) Sense (-) Excitation (-) Signal (+) Red Brown White Yellow Black Blue
Specifications and dimensions are subject to change without notice and do not constitute any liability whatsoever. Zemic Europe B.V. T: +31 76 50 39480 Nr. 2023.12 L6F Rev7 info@zemic.nl Page 3/3 www.zemiceurope.com Dimensions in mm Front View Side View Top View Isometric View Dimension Capacity H H1 L W W1 M 50kg – 200kg 75 50 156 44 24 M12 250kg – 500kg, 750kg-W1 95 70 146 60 36 M12 750 – 2000kg 125 95 176 76 46 M16