L4006L5 ISC
Document overview
- Manufacturer or author: Provided By www.digicamel.com(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 2
Technical content
isc website:www.iscsemi.com isc & iscsemi is registered trademark isc Triacs L4006L5
FEATURES
- With TO-220AB(Isolated) non insulated package
- Suitable for general purpose AC switching. Which can be used as an ON/OFF function in applications such as static relays, heating regulation,induction motor starting circuits. Or for phase control operation in light dimmers, motor speed controllers etc.
- Minimum Lot-to-Lot variations for robust device performance and reliable operation ABSOLUTE MAXIMUM RATINGS(Ta=25℃) SYMBOL PARAMETER MIN UNIT VDRM Repetitive peak off-state voltage 400 V VRRM Repetitive peak off-state voltage 400 V IT(RMS) RMS on-state current (full sine wave) Tc=95℃ 6 A ITSM Non-repetitive peak on-state current f=50Hz 50 A f=60Hz 60 Tj Operating junction temperature -40~110 ℃ Tstg Storage temperature -40~125 ℃ Rth(j-c) Thermal resistance, junction to case 3.6 ℃/W Rth(j-a) Thermal resistance, junction to ambient 50 ℃/W ELECTRICAL CHARACTERISTICS (TC=25℃ unless otherwise specified) SYMBOL PARAMETER CONDITIONS MAX UNIT IRRM Repetitive peak reverse current VR=VRRM, VR=VRRM, Tj=110℃ 500 uA IDRM Repetitive peak off-state current VD=VDRM, VD=VDRM, Tj=110℃ 500 uA IGT Gate trigger current (Ⅰ—Ⅳ) VD=12V; RL= 60Ω 5 mA IH Holding current IGT= 100mA, Gate Open 10 mA VGT Gate trigger voltage all quadrant VD=12V; RL= 60Ω 2 V VTM On-state voltage IT= 6A; tp= 380μ s 1.6 V
isc website:www.iscsemi.com isc & iscsemi is registered trademark isc Triacs L4006L5 NOTICE: ISC reserves the rights to make changes of the content herein the datasheet at any time without notification. The information contained herein is presented only as a guide for the applications of our products. ISC products are intended for usage in general electronic equipment. The products are not designed for use in equipment which require specialized quality and/or reliability, or in equipment which could have applications in hazardous environments, aerospace industry, or medical field. Please contact us if you intend our products to be used in these special applications. ISC makes no warranty or guarantee regarding the suitability of its products for any particular purpose, nor does ISC assume any liability arising from the application or use of any products, and specifically disclaims any and all liability, including without limitation special, consequential or incidental damages.