JB06 ZEMIC

Document overview

  • Manufacturer or author: Provided By www.digicamel.com(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

Specifications and dimensions are subject to change without notice and do not constitute any liability whatsoever. Zemic Europe B.V. T: +31 76 50 39480 Nr. 2022.12 JB06 Rev4 info@zemic.nl Page 1/2 www.zemiceurope.com Short Description

  • Junction Box, fit for 4-wire and 6-wire load cells
  • Cast aluminium housing, grey powdercoated
  • Easy installation
  • Surge protection Available Models Model Amount of Connections Full Article Description Part Number JB06C 3 JB06C-3 30060200

4 JB06C-4 30060300

6 JB06C-6 30060400

8 JB06C-8 30060500

Detailed Specifications JB06 Load Cell Output Resistance Range Ω 340 to 1100 Load Cell Input Resistance Range Ω 340 to 1100 Excitation, Recommended Voltage V(AC&DC) 5 to 17 Excitation, Maximum Voltage V(AC&DC) 18 Load Cell Sensitivity Range mV/V 0.6 – 3 Cable Diameter Ø mm 5 - 6.2 Correction Method Signal trim Trimming Range Ω 14 Temperature Range, Operating °C -40 ~ +85 Ingress Protection IP66 Housing Connected to Shield Yes External Grounding Yes