Specifications and dimensions are subject to change without notice and do not constitute any liability whatsoever. Zemic Europe B.V. T: +31 76 50 39480 Nr. 2022.12 JB05A Rev5 info@zemic.nl Page 1/2 www.zemiceurope.com Short Description

  • Junction box, fit for 4-wire and 6-wire load cells
  • Easy installation
  • Cast aluminium housing
  • Black protective coating Available Models Model Amount of Connections Full Article Description Part Number JB05A 4 JB05A-4 30050300

6 JB05A-6 30050400

8 JB05A-8 30050500

Detailed Specifications JB05A Load Cell Output Resistance Range Ω 340 to 1100 Load Cell Input Resistance Range Ω 340 to 1100 Excitation, Recommended Voltage V(AC&DC) 5 to 17 Excitation, Maximum V(AC&DC) 18 Load Cell Sensitivity Range mV/V 0.6 – 3 Cable Diameter Ø mm 4.8 to 8 Correction Method Signal trim Temperature Range, Operating °C -35 ~ +65 Ingress Protection IP66 Housing Connected to Shield Yes External Grounding Yes