Document overview

  • PDF pages: 19

Technical content

Page 1

PDF page 1 diagram

Description

The IMX15, IMS15, and IMY15 Series of board mountable 15 Watt DC-DC converters have been designed according to the latest industry requirements and standards. The converters are particularly suitable for use in mobile or stationary applications in transport, railways, industry, or telecommunication, where variable input voltages or high transient voltages are prevalent. Covering a total input voltage range from 8.4 up to 150 V with different models, the converters are available with single and electrically-isolated double outputs from 3.3 up to 48 V, externally adjustable, with flexible load distribution on doubleoutput models. A shutdown input allows for remote on/off.

Features include efficient input and output filtering and consistently high efficiency over the entire input voltage range, high reliability, and excellent dynamic response to load and line changes. The converters have been approved by CSA. 20IMS/20IMX15 and 40IMS/40IMX15 models provide supplementary insulation. Connected to a secondary circuit, these models provide SELV

Table of Contents

Page

Description ............................................................................. 1 Model Selection ..................................................................... 2 Functional Description ........................................................... 4 Electrical Input Data ............................................................... 5 Electrical Output Data ............................................................ 8 Auxiliary Functions ............................................................... 13

Features

  • RoHS lead-free-solder and lead-solder-exempted products are available.
  • Wide input voltage ranges up to 150 VDC
  • 1 or 2 isolated outputs up to 48 V
  • 1500 to 3000 VAC I/O voltage withstand test
  • Emissions EN 55022 level A
  • Immunity to IEC/EN 61000-4-2,-3,-4,-5, and -6
  • Fire&smoke as per EN 45545
  • High efficiency (typ. 86%)
  • Input undervoltage lockout
  • Shutdown input, adjustable output voltages
  • Flex power: Flexible load distribution on outputs
  • Outputs no-load, overload, and short-circuit proof
  • Operating ambient temperature –40 to 85 °C
  • Thermal protection
  • 2" x 1.6" case with 10.5 mm profile
  • Supplementary insulation: 20/40IMX15 models, double or reinforced insulation: 110IMY15 models Safety-approved to IEC 60950-1 and UL/CSA 60950 -1 2nd Edition

1

1 110IMY15 models

outputs, even if the bus voltage at the converter input exceeds the SELV-limit of 60 VDC. The 110IMY15 models provide double insulation and are CE marked. They may be connected to a rectified 110 VAC source without any further isolation barrier. The circuitry is comprised of integrated planar magnetics. All components are automatically assembled and solidly soldered onto a single PCB without any wire connection. Magnetic feedback ensures maximum reliability and repeatability in the control loop over all operating conditions. Careful consideration of possible thermal stress ensures the absence of hot spots providing long life in environments, where temperature cycles are frequent. The thermal design allows

operation at full load up to an ambient temperature of 71 °C in free air without using any potting material. For extremely high vibration environments the case has holes for screw mounting.

Page

Electromagnetic Compatibility (EMC) .................................. 14 Immunity to Environmental Conditions ................................ 16 Mechanical Data .................................................................. 17 Safety and Installation Instructions ...................................... 18 Description of Options ......................................................... 19 Accessories.......................................................................... 19

Copyright © 2017, Bel Power Solutions Inc. All rights reserved.

Page 1 of 19

Page 2

Model Selection

Table 1: Model Selection

PDF page 2 diagram

Flexible load distribution on dual and double outputs possible; up to 75% of the total output power Po nom on one of the 2 outputs. 1 IMX/IMY15-0503 models have reduced load distribution flexibility; 1.8 A max. on one of the 2 outputs. The total output power should not exceed Po nom. See Description of Options. 2 Short-time operation down to Vi = 14.4 V possible (Po reduced to approx. 85% of Po nom) 3 Short-time operation down to Vi = 43.2 V possible (Po reduced to approx. 85% of Po nom) and up to 154 V 4 Initial start-up at 9 V, main output voltage regulation down to 8.4 V 5 Efficiency at TA = 25 °C, Vi nom, Io nom. 6 SR Models with synchronos rectifier. For the RoHS version of such models, add -G !

Preferred for new designs. NFND Not for new designs. Replace 24IMS15 models by 20IMX15 and 48IMS15 by 40IMX15;

Replace 20IMX15-05, 40IMX15-05, 110IMY15-05 by models with synchronos rectifierSR; for new designs, chose always the RoHS version !

Page 2 of 19

Page 3

RoHS-Compliant Models The type designation of RoHS-compliant models (compliant for the restriction of all six substances) for the IMX/IMY15 Series ends with "G". However, in single-output models with 3.3 V or 5.1 V output an extra hyphen (-) is added after the existing "G", which already signifies a synchronous rectifierSR. This is an exception to our normal nomenclature to identify this type of product, since G is already used to designate products for higher output current fitted with a synchronous rectifier. Some examples – 20IMX15-05-8R-G designates a standard version with RoHS compliance for all six substances. – 20IMX15-05-8RG designates a synchronous rectifierSR version which is not RoHS-compliant.

– 20IMX15-05-8RG-G designates a synchronous rectifierSR version and RoHS compliant for all six substances. – 20IMX15-05-05-8G designates a double-output model with RoHS compliance for all six substances – 110IMY15-24-24-8RG designates a double-output model with RoHS compliance for all six substances.

Part Number Description

40 IMX15 - 05 -8 R G Z -G

xxix

PDF page 3 diagram

Input voltage range Vi

8.4 to 36 V ...................................................... 20 14 to 36 V ....................................................... 24 16.8 to 75 V .................................................... 40 36 to 75 V ....................................................... 48 50 to 150 V ................................................... 110

Series

IMX15, IMS15, IMY15

Output voltage of output 1............................03, 05, 12, 15, 24 Hyphen designating double-output models with two

electrically isolated outputs ...............................-

Output voltage of output 2............................03, 05, 12, 15, 24 Operating ambient temperature range TA

– 40 6 to 85 °C ..................................................-8 6 – 40to 71 °C.....................................................-9 2

Options and features:

R input and magnetic feedback....................... R Synchronous rectification ................................ G Inhibit ................................................................. i Open frame ......................................................Z RoHS-compliant for all 6 substances........ G or -G Not applicable to -0503 models. They have a common ground. 1 IMS15 models are not recommended for new designs. 2 Standard for single-output and -0503 models 3 Option i replaces the standard shutdown function; see Description of Options. 4 RoHS models with synchronous rectifier end as an exception with -G. 5 Only –25 °C for older -8RGSR models (Rev. < BA); see table 7a.

6

Note: The sequence of options must follow the order above !

Examples: 20 IMX15-05-05-8G: DC-DC converter, input 9 to 36 V, 2 galvanically isolated outputs each providing 5 V, 1.3 A,

RoHS-compliant 110IMY15-0503-8RG: DC-DC converter, input 50 to 150 V, 2 outputs with common return providing +5.1 V, 1.5 A and +3.3 V, 1.5 A, RoHS-compliant. Converter fitted with magnetic feedback for tight output voltage regulation.

Product Marking The converters without option Z are marked with basic type designation, input and output voltages and currents, applicable safety approval and recognition marks, patent nos., company logo, date code, and serial number.

Page 3 of 19

Page 4

Functional Description

The IMX15/IMS15/IMY15 Series of DC-DC converters are magnetic feedback-controlled flyback converters using current mode PWM (Pulse Width Modulation). The -05- and -0503- output voltage models exhibit an active magnetic feedback loop via a pulse transformer, resulting in very tight regulation of the output voltage (see the block diagrams). The output voltages of these models can be adjusted via the R-input. The R-input is referenced to the secondary side and allows for programming the output voltages in the range of approximately 80 to 105% of Vo nom, using either an external resistor or an external voltage source. Several single-output models with 3.3 or 5.1 V output exhibit a

synchronous rectifier to improve the efficiency. The voltage regulation on the double-output models is achieved with an auxiliary winding of the main transformer. The output voltages can be adjusted via the Trim input, which is referenced to the primary side and allows for programming the output voltage in the range of 100 to 105% of Vo nom via an external resistor, or within 75 to 105% if using an external voltage source. The load regulation output characteristic allows for paralleling of one or more double-output models with equal output voltage. Current limitation is provided by the primary circuit, thus limiting the total output power of double-output models. The shutdown

input allows remote converter on/off. Overtemperature protection will disable the converter under excessive overload conditions with automatic restart.

PDF page 4 diagram

Fig. 1 Block diagram of single-output models

PDF page 4 diagram

Fig. 2 Block diagram of -0503-models

PDF page 4 diagram

Fig. 3 Block diagram of double-output models

Page 4 of 19

Page 5

Electrical Input Data

General conditions: – TA = 25 °C, unless TC is specified. – Shut-down pin left open-circuit. – Trim or R input left open-circuit.

Table 2a: Input data of IMX15 and IMY15 models

Input 20IMX 40IMX 110IMY Unit
Characteristics Conditions min typ max min typ max min typ max
V i Input voltage range 1 T – T A min A max I = 0 – I o o nom 9 5, 7 36 16.8 5, 6 75 50 5 150 8 V
V i nom Nominal input voltage 20 40 110
V i sur Repetitive surge voltage Abs. max input (3 s) 40 100 168
t startup Converter start-up time 2 Switch on Worst case condition at V min, I = I i o o nom 0.25 0.5 0.25 0.5 0.5 0.8 s
SD high 0.1 0.1 0.1
t rise Rise time 2 V , resistive load i nom 5 5 5 ms
I , capac. load o nom 10 20 10 20 10 20
I i o No-load input current I = 0, V – V o i min i max 65 45 15 mA
I irr Reflected ripple current I = 0 – I o o nom 30 30 20 mA pp
I inr p Inrush peak current 3 V = V i i nom 8 9 10 A
C i Input capacitance for surge calculation 1.5 0.75 0.35 µF
V–– SD Shut-down voltage Converter disabled –10 to 0.7 –10 to 0.7 –10 to 0.7 V
Converter operating open or 2 – 20 open or 2 – 20 open or 2 – 20
R–– SD Shut-down input resistance approx. 10 approx. 10 approx. 10 kΩ
I–– SD Input current, when disabled V – V i min i max SD connected to Vi– 10 3 1 mA
f s Switching frequency V – V , i min i max I = 0 – I o o nom approx. 300 approx. 300 approx. 300 kHz
V i RFI Input RFI level conducted EN 55032 4 A A A

If Vo is set above Vo nom by use of the R or Trim input, Vi min will be proportionately increased. 1 Measured with resistive and max. admissible capacitive load. Valid for models with rev. AI or greater. 2 Source impedance according to ETS 300132-2, version 4.3. 3 Measured with a ceramic capacitor Ci directly across input; output lead length 0.1 m, leads twisted. Double-output models with both 4 outputs in parallel. Ci is specified in table 11. Input undervoltage lockout at typ. 80% of Vi min. 5 Short time operation down to Vi min >14.4 V possible. Po reduced to approx. 85% of Po nom. 6 Initial start-up at Vi = 9 V, main output voltage regulation down to 8.4 V

7 Short time operation up to 154 V possible for 2 s. 8

Page 5 of 19

Page 6

Table 2b: Input Data of IMS15 models; general conditions as in table 2a

Input 24IMS 48IMS Unit
Characteristics Conditions min typ max min typ max
V i Input voltage range 1 T – T A min A max I = 0 – I o o nom 14 36 36 75 V
V i nom Nominal input voltage 24 48
V i sur Repetitive surge voltage Abs. max input (3 s) 50 100
t startup Converter start-up time 2 Switch on Worst case condition at V min, I = I i o o nom 0.25 0.5 0.25 0.5 s
SD high 0.1 0.1
t rise Rise time 2 V , resistive load i nom 5 5 ms
I , capac. load o nom 10 20 10 20
I i o No-load input current I = 0, V – V o i min i max 20 40 10 20 mA
I irr Reflected ripple current I = 0 – I o o nom 30 30 mA pp
I inr p Inrush peak current 3 V = V i i nom 5 4.5 A
C i Input capacitance for surge calculation 4 2 µF
V–– SD Shut-down voltage Converter disabled –10 to 0.7 –10 to 0.7 V
Converter operating open or 2 – 20 open or 2 – 20
R–– SD Shut-down input resistance approx. 10 approx. 10 kΩ
I–– SD Input current, when disabled V – V i min i max SD connected to Vi– 1.2 3 1.2 3 mA
f s Switching frequency V – V , i min i max I = 0 – I o o nom approx. 300 approx. 300 kHz
V i RFI Input RFI level conducted EN 55022 4 A A

If Vo is set above Vo nom by use of the R or Trim input, Vi min will be proportionately increased. 1 Measured with resistive and max. admissible capacitive load. 2 Source impedance according to ETS 300132-2, version 4.3. 3 Measured with a ceramic capacitor Ci directly across input; output lead length 0.1 m, leads twisted. Double-output models with both 4 outputs in parallel. Ci is specified in table 11. Input undervoltage lockout at typ. 80% of Vi min. 5

Page 6 of 19

Page 7

Inrush Current The inrush current has been made as low as possible by choosing a very small input capacitance. A series resistor may be installed in the input line to further reduce this current.

PDF page 7 diagram

Fig. 4 Typical inrush current at Vi nom, Po nom versus time (40IMX15). Source impedance according to ETS 300132-2 at Vi nom.

PDF page 7 diagram

Vo nom

Fig. 5 Converter start-up and rise time

Input Undervoltage Lockout A special feature of these converters is the accurate undervoltage lockout protection, which protects against large currents caused by operation at low voltages. This ensures easier start-up in distributed power systems.

Tab. 3: Turn on and turn off voltage

Model Turn on Turn off Unit
min max min max
20IMX15 7.5 8 7 7.5 V
24IMS15 12.5 13.5 12 13
40IMX15 12.5 13.5 12 13
48IMS15 31.5 32.5 31 32
110IMY15 40 42.5 38 40.5

Fuse and Reverse Polarity Protection The built-in suppressor diode also provides for reverse polarity protection at the input by conducting current in the reverse direction. An external fuse is required to limit this current. Table 4: Recommended external fuses

Model Fuse type
20IMX15 F 4.0 A
24IMS15 F 3.15 A
40IMX15, 48IMS15 F 2.0 A
110IMY15 F 1.0 A

Input Transient Voltage Protection A built-in suppressor diode provides effective protection against input transients, which typically occur in many installations. Table 5: Built-in transient voltage suppressor

Type Breakdown voltage V [V] Br nom Peak power at 1 ms P [W] p Peak pulse current I [A] pp
20IMX15 40 1500 22
24IMS15 53 600 7.7
40IMX15 100 1500 9.7
48IMS15 100 600 4.1
110IMY15 168 600 0.5

For very high energy transients as for example to achieve compliance to IEC/EN 61000-4-5 (see table Electromagnetic Immunity), an external inductor and a capacitor are required, see Fig. 6. The components are specified in table 6.

PDF page 7 diagram

Fig. 6 Example for external circuitry to achieve better transient immunity. Values of components in the table below.

Table 6: Components for external circuitry for IEC/EN 61000-4-5, level 3 compliance.

Model Inductor (L) Capacitor (C)
20IMX15 220 µH, 2.7 A 2 x 330 µF, 63 V
24IMS15 220 µH, 1.3 A 2 x 330 µF, 63 V
40IMX15 220 µH, 1.3 A 2 x 330 µF, 100 V
48IMS15 220 µH, 1 A 2 x 330 µF, 100 V
110IMY15 220 µH, 0.4 A 2 x 330 µF, 200 V

Page 7 of 19

Page 8

Electrical Output Data

We recommend connecting an external 1 µF ceramic capacitor across the output pins. General conditions: – TA = 25 °C, unless TC is specified – Shutdown pin and Trim or R pin left open-circuit (not connected)

Table 7a: Output data for single-output models -03-8RG 1 and 05-8RG 1

Output 3.3 V 5.1 V Unit
Characteristics Conditions min typ max min typ max
V o Output voltage V i nom I = 0.5 I o o nom 3.25 3.35 5.05 5.15 V
I o nom Output current 20IMX 40IMX /110IMY V to V i min i max 4.5 3.5 A
4.5 3.5
I o L Current limit 2 V , T = 25 °C i nom C V ≤ 93% V o o nom 6.0 4.6
∆V o Line/load regulation V to V , i min i max (0.1 to 1) I o nom ±0.5 ±0.5 %
V o Output voltage noise V to V 4 i min i max I = I o o nom 5 100 100 mV pp
60 60
V o L Output overvoltage limit. 3 115 130 115 130 %
C o ext Admissible capacitive load 0 4000 6 0 4000 6 µF
V o d Dynamic load regulation Voltage deviat. V i nom I ↔ 1/2 I o nom o nom IEC/EN 61204 ±250 ±250 mV
t o d Recovery time 1 1 ms
α Vo Temperature coefficient ∆V /∆T o C V to V i min i max (0.1 to 1) I o nom ±0.02 ±0.02 %/K

SR Models -8RG (synchr. rectifier) have a minimum case and operating temperature of –25 °C. If the revision is BA (or later), it is –40 °C. 1 The current limit is primary side controlled. In the event of a sustained overload condition the thermal protection may cause the converter 2 to shut down (restart after cooling down). The overvoltage protection is via a primary side second regulation loop. It is not tracking with R control. 3 BW = 20 MHz 4 Measured with a probe according to EN 61204 5 Co ext is limited to 3000 µF, if Vi >125 V or TA < 25 °C 6

Page 8 of 19

Page 9

Table 7b: Output data for -05-8R and -0503-8R models; general conditions as in table 7a

PDF page 9 diagram

Flexible load distribution: Io max for one of the 2 outputs; however the total load should not exceed Po nom specified in the table Model 1 Selection. The current limit is primary-side controlled. 2 For -0503-models: total capacitive load of both outputs. 3 For -0503-models: Conditions for specified output. Other output loaded with constant current Io = 0.5 Io nom. 4 BW = 20 MHz 5 Measured with a probe according to EN 61204 6 The overvoltage protection is via a primary side second regulation loop. It is not tracking with R control. 7

Page 9 of 19

Page 10

able 7c: Output data for double-output models; general conditions as in table 7a

Output 2 ××××× 5 V 2 ××××× 12 V 2 ××××× 15 V 2 ××××× 24 V Unit
Characteristics Conditions min typ max min typ max min typ max min typ max
V o1 Output 1 24IMS/48IMS other models V i nom I = 0.5 I o o nom 4.95 5.05 11.88 12.12 14.85 15.15 23.70 24.30 V
4.95 5.05 11.90 12.10 14.88 15.12 23.80 24.20
V o2 Output 2 24IMS/48IMS other models 4.94 5.06 11.84 12.16 14.80 15.20 23.64 24.36
4.94 5.06 11.88 12.12 14.85 15.15 23.75 24.25
I o nom Output current 1 20IMX other models V – V i min i max 2 ××××× 1.3 2 ××××× 0.65 2 ××××× 0.50 2 ××××× 0.32 A
2 ××××× 1.4 2 ××××× 0.70 2 ××××× 0.56 2 ××××× 0.35
I oL Current limit 2, 4 20IMX 24IMS/48IMS 40IMX/110IMY V i nom V ≤ 93% V o1 o nom 3.0 1.6 1.3 0.85
3.5 1.9 1.6 0.95
3.2 1.7 1.4 0.90
∆V o1 Line/load regulation 8 output 1 output 2 V – V , I i min i max o nom ±1 ±1 ±1 ±1 %
∆V o2 V , (0.1 – 1) I i nom o nom ±3 ±3 ±3 ±3
V o1/2 Output voltage noise V – V 5 i min i max I = I o o nom 6 80 120 150 240 mV pp
40 60 70 120
V o L Output overvoltage limit 7 8 Min. load 1% 115 130 115 130 115 130 115 130 %
C o ext Admissible capacitive load 3 0 4000 0 680 0 470 0 180 µF
V o d Dynamic load regulation Voltage deviat. V i nom I ↔ 1/2 I o nom o nom ±250 ±300 ±300 ±600 mV
t o d Recovery time 1 1 1 1 ms
α Vo Temperature coefficient ∆V /∆T o C V – V i min i max (0.1 – 1) I o nom ±0.02 ±0.02 ±0.02 ±0.02 %/K

Flexible load distribution: Each output of double-output models is capable of delivering 75% of the total output power; however the total 1 load should not exceed Po nom specified in the table Model Selection. The current limit is primary-side controlled. 2 Measured with both outputs connected in parallel. 3 Conditions for specified output. Other output loaded with constant current Io = 0.5 Io nom. 4 BW = 20 MHz 5 Measured with a probe according to EN 61204 6 The overvoltage protection is via a primary side second regulation loop, not tracking with Trim or R control. 7 At start-up occurs a short overshoot at the output. 8

Page 10 of 19

Page 11

Thermal Considerations If a converter, mounted on a PCB, is located in free, quasistationary air (convection cooling) at the indicated maximum

TA max (see table Temperature

ambient temperature specifications) and is operated at its nominal input voltage and output power, the case temperature measured at the measuring point of case temperature TC (see Mechanical Data) will approach the indicated value TC max after the warmup phase. However, the relationship between TA and TC depends heavily on the conditions of operation and integration into a system. The thermal conditions are influenced by input voltage, output current, airflow, temperature of surrounding components and surfaces, and the properties of the printed circuit board. TA max is therefore only an indicative value. Caution: The case temperature TC measured at the measuring

point of case temperature TC (see Mechanical Data) may under no circumstances exceed the specified maximum value. The installer must ensure that under all operating conditions TC remains within the limits stated in the table Temperature specifications.

Po/Po max

PDF page 11 diagram

Fig. 7 Maximum output power versus ambient temperature

Overtemperature Protection The converters are protected from possible overheating by means of an internal temperature monitoring circuit. It shuts down the converter above the internal temperature limit, and attempts to automatically restart in short intervals. This feature helps protect against excessive internal temperatures, which could occur during heavy overload conditions.

Output Overvoltage Protection The output of single-output models as well as -0503- and -05- 05-models are protected against overvoltage by a second control loop. In the event of an overvoltage on one of the outputs, the converter will shut down and attempt to restart in short intervals. Doubel-output models (except -0503- and -05-05-models) are protected against overvoltage by a Zener diode across the second output. Under worst case conditions the Zener diode will become a short circuit. Since with double-output models both outputs track each other, the protection diode is only provided in one of the outputs. The main purpose of this feature is to protect against possible overvoltage, which could

occur due to a failure in the control logic. This protection circuit is not designed to withstand externally applied overvoltages.

Short Circuit Behavior The current limit characteristic shuts down the converter, whenever a short circuit is applied to its output. It acts selfprotecting, and automatically recovers after removal of the overload condition (hiccup mode).

Parallel and Series Connection The outputs of one or several single- or double-output models

Vo [%]

PDF page 11 diagram

Fig. 8 Overload switch-off (hiccup mode); typical values

can be connected in series without any precautions, taking into consideration that the highest output voltage should remain below 42 V to ensure that the output remains SELV. Both outputs of the same converter with equal voltage (e.g. 5 V / 5 V) can be connected in parallel and will share their output currents equally. Parallel operation of single or double outputs of two or more converters with the same output voltage may cause start-up problems at initial start-up. This is only advisable in applications, where one converter is able to deliver the full load current as, for example, required in true redundant systems. Note: If the 2nd output of double-output models (except 0503) is not

used, connect it in parallel to the 1st output.

Typical Performance Curves General conditions: – TA = 25 ºC, unless TC is specified. – Shutdown pin left open-circuit. – Trim or R input not connected.

PDF page 11 diagram

0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4 A

Fig. 9 Vo versus Io (typ) of converters with Vo = 5.1 V (110IMY15-05-8R)

Page 11 of 19

Page 12

V

PDF page 12 diagram

0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 A

Fig. 10 Vo versus Io (typ.) of double-output models (2 x 12 V), with both outputs in parallel (110IMY15-12-12-8)

V

PDF page 12 diagram

0.5 0.6 0.7 A

0.3 0.4

0.1 0.2

Fig. 11 Cross load regulation Vo1 versus Io1 (typ.) for various Io2 (2 x 12 V).

%

PDF page 12 diagram

1 Po/Po nom

0.25

0.5

0.75

Fig. 12a Efficiency versus input voltage and load. Typical values (40IMX15-12-12-8).

%

PDF page 12 diagram

1 Po/Po nom

0.25

0.5

0.75

Fig. 12b Efficiency versus input voltage and load. Typical values (110IMY15-12-12-8)

%

PDF page 12 diagram

1 Io1/Io1 nom

0.5

0.75

0.25

Fig. 12c Efficiency versus input voltage and load. Typical values (48IMS15-12-12-9)

PDF page 12 diagram

Fig. 13 Flexible load distribution on double-outputs models with option R (110IMY15-12-12-8R): Load variation from 0 to 150% of Io1 nom on output 1; output 2 loaded with 50% of Io2 nom.

Page 12 of 19

Page 13

Auxiliary Functions

Shutdown Function The outputs of the converters may be enabled or disabled by means of a logic signal (TTL, CMOS, etc.) applied to the shutdown pin. If this function is not required, the shut-down pin should be left open-circuit.

  • Converter operating:

2.0 to 20 V

  • Converter disabled:

–10 to +0.7 V

Adjustable Output Voltage

  • R input for single-output models and -0503-models
  • Trim input for double-output models

As a standard feature, the single- and double-output models offer adjustable output voltage(s) by using the control input R or Trim. If the control input is left open-circuit, the output voltage is set to Vo nom. For output voltages Vo > Vo nom, the minimum input voltage Vi min (see Electrical Input Data) increases

proportionally to Vo/Vo nom. Single-output models with synchronous rectifier (G): The R input is referenced to the secondary side of the converter. Adjustment of the output voltage is possible by means of an external resistor connected between the R pin and either Vo+ or Vo–. Note: For models with synchronous rectifier the logic for Vo adjustment differs from other models with R input.

PDF page 13 diagram

Fig. 14 Output voltage control for single-output models with synchronous rectifier.

Table 8: Vo versus Vext approximate values

PDF page 13 diagram

All other models fitted with R-input: The R input is referenced to the secondary side of the converter. Adjustment of the output voltage is possible by means of either an external resistor or a voltage source.

a) Adjustment by means of an external resistor Rext. Depending upon the value of the required output voltage, the resistor shall be connected: either: Between the R pin and Vo– to achieve an output voltage adjustment range of Vo ≈ 80 to 100 % of Vo nom. Vo Rext1 ≈ 4 kΩ • ––––––––– Vo nom – Vo or: Between the R pin and Vo+ to achieve an output voltage range of Vo ≈ 100 to 105% of Vo nom.

(Vo – 2.5V) Rext2 ≈ 4 kΩ • –––––––––––––––––– 2.5 V • (Vo/Vo nom – 1) b) Adjustment by means of an external voltage Vext between Vo– and R pin. The control voltage range is 1.96 to 2.62 V and allows for adjustment in the range of Vo ≈ 80 to 105% of Vo nom. Vo • 2.5 V Vext ≈ –––––––– Vo nom Attempting to adjust the output below this range will cause the converter to shut down (hiccup mode). Note: Applying an external control voltage >2.75 V may damage the converter.

06029e

Vi+ Vi– V = 2.5 V 4 kΩ ref + Control logic Vo+ R ext2 R + R ext1 – Vo–

Vext

Fig. 15 Output voltage control for single-output models, -0503-models, and double-output models by means of the R input.

Double-output models with Trim input: The Trim input is referenced to the primary side. The figure below shows the topology. Adjustment is possible trough either an external resistor or an external voltage source Vext.

06089a

Vi+ Trim R ext Vi– Control circuit V 2.5 V ref Vo1+
Vo1– Vo2+ Vo2–

+ Vext –

Fig. 16 Output voltage control for double-output models (with Trim input) by means of the Trim input.

Page 13 of 19

Page 14

a) Adjustment by means of an external resistor Rext: Programming of the output voltage by means of an external resistor Rext is possible within 100 to 105% of Vo nom. Rext should be connected between the Trim pin and Vi–. Connection of Rext to Vi+ may damage the converter. The table below indicates suitable resistor values for typical output voltages under nominal conditions (Vi nom, Io = 0.5 Io nom) with either parallel-connected outputs or equal-load conditions on both outputs. Table 9a: Rext for Vo > Vo nom; approximate values (Vi nom, Io1, 2 = 0.5 Io1/2 nom )

V [% V ] o o nom R ext [kΩΩΩΩΩ]
105 to 108 (107 typically) 105 104 103 102 101 100 0 1.5 5.6 12 27 68 ∞

Electromagnetic Compatibility (EMC)

A suppressor diode together with an input filter forms an effective protection against high input transient voltages, which

Electromagnetic Immunity

Table 10: Immunity type tests

b) Adjustment by an external voltage source Vext: For programming the output voltage in the range 75 to 105% of Vo nom, a source Vext (0 to 20 V) is required, connected between the Trim pin and Vi–. The table below indicates values Vo versus Vext (nominal conditions Vi nom, Io = 0.5 Io nom), with either parallel-connected outputs or equal load conditions on both outputs. Applying a control voltage >20 V will set the converter into a hiccup mode. Direct paralleling of the Trim pins of parallel connected converters is possible.

Table 9b: Vo versus Vext for Vo = 75 to 105% Vo nom; typical values (Vi nom, Io1/2 = 0.5 Io1/2 nom)

PDF page 14 diagram

typically occur in many installations, but especially in batterydriven mobile applications.

Phenomenon Standard Class Level Coupling mode 2 Value applied Waveform Source Imped. Test procedure In oper. Perf. crit. 3
Electrostatic discharge to case IEC/EN 61000-4-2 2 contact discharge (R pin open) 4000 V p 1/50 ns 330 Ω 150 pF 10 positive and 10 negative discharges yes B
3 air discharge (R pin open) 8000 V p
Electromagnetic field IEC/EN 61000-4-3 x 5 3 6 antenna 20 V/m 5 3 V/m 6 AM 80% 1 kHz n.a. 80 to 1000 MHz yes A
ENV 50204 3 antenna 10 V/m PM, 50% duty cycle, 200 Hz repetition frequ. n.a. 900 MHz yes A
Electrical fast transients/burst IEC/EN 61000-4-4 3 4 direct +i/–i 2000 V 4 p bursts of 5/50 ns 5 kHz rep. rate transients with 15 ms burst duration and a 300 ms period 50 Ω 60 s positive 60 s negative transients per coupling mode yes A
Surges IEC/EN 61000-4-5 2 3 1 +i/–i 1000 V p 2000 V 1 p 1.2/50 µs 2 Ω 18 µF 5 pos. and 5 neg. surges yes B
RF conducted immunity IEC/EN 61000-4-6 3 2 6 +i/–i 10 VAC 3 VAC 6 AM modulated 80%, 1 kHz 150 Ω 0.15 to 80 MHz yes A

External components required; see Fig. 6 and table 6. 1 i = input, o = output. 2 A = normal operation, no deviation from specs., B = temporary deviation from specs. possible. 3 Corresponds to the railway standard EN 50121-3-2:2006, table 9.3. Corresponds to the railway standard EN 50121-3-2:2006, table 9.1. Valid for 24IMS15 and 48IMS15

Page 14 of 19

Page 15

Conducted Emissions

PMM 8000 PLUS Date: 24.04.06 Time: 16:23

dbµV

Name: 20d12_1

20IMX15-12-12-8 Peak

PDF page 15 diagram

Fig. 17a Typ. disturbance voltage (peak) at pos. input according to EN 55011/032, measured at Vi nom and Io nom. Output leads 0.1 m, twisted, input capacitors see table 11 (20IMX15-12-12-8)

Date: 24.04.06 Time: 15:2 PMM 8000 PLUS Name: 40d12_1 40IMX15-12-12-8 Peak

dbµV

PDF page 15 diagram

Fig. 17b Typ. disturbance voltage (peak) at pos. input according to EN 55011/032, measured at Vi nom and Io nom. Output leads 0.1 m, twisted, input capacitors see table 11 (40IMX15-12-12-8)

Date: 25.04.06 Time: 08:07 PMM 8000 PLUS

dbµV

Peak

Name: 110d12_1 110IMY15-12-12-9

PDF page 15 diagram

Fig. 17c Typ. disturbance voltage (peak) at pos. input according to EN 55011/032, measured at Vi nom and Io nom. Output leads 0.1 m, twisted, input capacitors see table 11 (110IMY15-12-12-8)

Table 11: External capacitors across the input to comply with EN 55011/EN 55032, Class A, conducted; see fig. 17.

Model Ceramic ML Electrolytic capacitor
20IMX15, 24IMS15 0.47 µF/50 40IMX15, 48IMS15 0.33 µF/10 110IMY15 0.15 µF/20 V 220 µF/50 V 0 V 220 µF/100 V 0 V 4.7 µF/200 V

Date: 02.05.06 Time: 09:58 PMM 8000 PLUS

dbµV

Name: 40d12_4 40IMX15-12-12-8-Peak

PDF page 15 diagram

Fig. 18 Typ. disturbance voltage (peak) at input according to EN 55011/022, measured at Vi nom and Io nom. Output leads 0.1 m, twisted, input filter as in fig. 19 (40IMX15-12-12-8)

PDF page 15 diagram

Fig. 19 Example for external circuitry to comply with EN 55011/ EN 55032, Class B, conducted. This filter was designed for a 40IMX15-12-12-8. All capacitors are rated to 100 V, the chokes to 1.5 A.

Page 15 of 19

Page 16

Immunity to Environmental Conditions

Table 12: Mechanical and climatic stress

Test Method Standard Test Conditions Status
Cab Damp heat steady state IEC/EN 60068-2-78 MIL-STD-810D sect. 507.2 Temperature: 40 ±2 •C Relative humidity: 93 +2/-3 % Duration: 56 days Converter not operating
Ea Shock (half-sinusoidal) IEC/EN 60068-2-27 MIL-STD-810D sect. 516.3 Acceleration amplitude: 50 g = 490 m/s2 n Bump duration: 11 ms Number of bumps: 18 (3 each direction) Converter operating
Fc Vibration (sinusoidal) IEC/EN 60068-2-6 Acceleration amplitude: 0.35 mm (10 to 60 Hz) 5 g = 49 m/s2 (60 to 2000 Hz) n Frequency (1 Oct/min): 10 to 2000 Hz Test duration: 7.5 h (2.5 h each axis) Converter operating
Fda Random vibration wide band reproducibility high IEC/EN 60068-2-35 Acceleration spectral density: 0.05 g 2/Hz n Frequency band: 20 to 500 Hz Acceleration magnitude: 4.9 g n rms Test duration: 3 h (1 h each axis) Converter operating
-- Salt mist test sodium chloride (NaCl) solution EN 50155:2007, clause 12.2.10 class ST2 Temperature: 35 ±2 °C Duration: 16 h Converter not operating

Temperatures

Table 14: Temperature specifications Valid for air pressure of 800 to 1200 hPa (800 to 1200 mbar)

Temperature -9 -8 Unit
Characteristics Conditions min max min max
T A Ambient temperature Operational 1 –40 71 –40 2, 3 85 °C
T C Case temperature –40 95 –40 2, 3 105
T S Storage temperature Non operational –55 85 –55 85

See Thermal Considerations 1 Start-up at –55 °C, except models with synchronous rectifier SR 2 –25 °C for all models with synchronous rectifier SR with Revision < BA. 3

Reliability

Table 13: MTBF

Model Standard Ground Benign Ground Fixed Ground Mobile Unit
T = 40 °C C T = 40 °C C T = 70 °C C T = 50 °C C
20IMX15-12-12-8 MIL-HDBK-217F 697 000 366 000 229 000 312 000 h
20IMX15-15-15-8 Belcore 2 345 000 1 172 000 632 000 317 000
48IMS15-05-05-9 MIL-HDBK-217F 535 000 283 000 179 000 245 000
110IMY15-05-8R MIL-HDBK-217F 485 000 255 000 167 000 223 000
Belcore 1 547 000 774 000 394 000 206 000

Page 16 of 19

Page 17

Mechanical Data

Dimensions in mm (inches). Tolerances ±0.3 mm, unless otherwise noted.

European Projection

Measuring point of case temperature TC

0.8 (0.03")

PDF page 17 diagram

Fig. 20

Case IMX15, IMS15, IMY15

Material: Fortron 1140L6

Weight: <35 g

0.8 (0.03")

PDF page 17 diagram

8.9 ±0.3 (0.35")

≥5 (0.19")

Fig. 21

Open frame (option Z)

for holes with

Page 17 of 19

Page 18

Safety and Installation Instructions

Pin allocation Table 15: Pin allocation

Pin Standard and Option Z single double -0503-
1 Vi+ Vi+ Vi+
2 Vi– Vi– Vi–
3 - Trim n.c.
4 SD SD SD
5 - - -
6 - - -
11 - Vo1+ Vo2+
12 - Vo1– Go
13 Vo+ Vo2+ Vo1+
15 Vo– Vo2– Go
17 R n.c. R
PDF page 18 diagram

Fig. 22 Footprint

Installation Instructions Installation must strictly follow the national safety regulations in compliance with the enclosure, mounting, creepage, clearance, casualty, markings and segregation requirements of the end-use application. The converter must be connected to a secondary circuit. Do not open the converter. Ensure that a converter failure (e.g., by an internal short-circuit) does not result in a hazardous condition.

Input Fuse To prevent excessive current flowing through the input supply lines in case of a malfunction an external fuse should be installed in a non-earthed input supply line; see table 4.

Standards and Approvals The converters are approved according to IEC 60950-1 and UL/ CSA 60950-1 2nd Edition. 110IMY models are fitted with a CE mark.

The converters have been evaluated for:

  • Building in
  • Supplementary insulation input to output, based on their maximum input voltage (IMX15, IMS15)
  • Reinforced insulation input to output, based on their maximum input voltage (IMY15 models)
  • Pollution degree 2 environment (not option Z)
  • Connecting the input to a secondary circuit subject to a maximum transient rating of 1500 V (IMX15, IMS15)
  • Connecting the input to a secondary circuit subject to a maximum transient rating of 2500 V (IMY15)

The converters are subject to manufacturing surveillance in accordance with the above mentioned UL standards and with ISO9001:2008.

Railway Applications To comply with railway standards, all components are coated with a protective lacquer (except option Z).

Protection Degree and Cleaning Liquids The protection degree of the converters is IP 40, except openframe models (option Z). In order to avoid possible damage, any penetration of cleaning fluids should be prevented, since the power supplies are not hermetical sealed. However, open-frame models (option Z) leave the factory unlacquered; they may be lacquered by the customer, for instance together with the mother board. Cleaning liquids are not permitted – except washing at room temperature with isopropyl alcohol. If necessary, the mother board must be cleaned, before fitting the open-frame converter. Note: Cleaning liquids may damage the adhesive joints of the

ferrite cores.

Isolation The electric strength test is performed in the factory as routine test in accordance with EN 50514 and IEC/EN 60950. The Company will not honor any warranty claims resulting from incorrectly executed electric strength field tests.

Table 16: Electric strength test voltages

Characteristic IMS15 Input to output Out IMX15 IMY15 output put toUnit
Factory test ≥1 s Equivalent DC voltage 1.2 1.51 3.0 0.1 kVAC
(1.7) (2.1) (4.2) 0.15 kVDC
Insulation resistance at 500 VDC >100 >100 >100 - MΩ
Partial discharge extinction voltage Consult the Company - kV

1 1.5 kVAC according to IEC 60950, sect. 6.2, Telecom equipment; type test with 1.5 kVAC / 60 s (IEE 802.3). IMX15 units produced before 2013 were tested only with 1.2 kVAC. 2 The test voltage between outputs is not applied as routine test.

Page 18 of 19

Page 19

Description of Options

Table 17: Survey of options

Option Function of option Characteristic
-9 Temperature range, NFND See table Temperatures specifications
i Inhibit Replaces the shutdown function with inverted logic
Z Open frame See Mechanical Data

Option -9 versus -8 IMX15 and IMY15 models with -9 (not for new designs) have a limited temperature range. Standard models with suffix -8 are rated up to TA = 85 °C; see table Temperature specifications.

Option i: Inhibit Replaces the shut-down function with inverted logic. The output(s) of the converter may be enabled or disabled by

PDF page 19 diagram

Fig. 23 If the inhibit function is not used, the inhibit pin should be connected to Vi–.

Accessories

Supports are available for chassis mounting CMBIMX15 (HZZ00626) and for DIN-rail mounting DMBIMX15 (HZZ00625). They exhibit the connectors and allow for placing different external components. For details see our Mounting Supports Data Sheet BCD20007 on our website.

means of a logic signal (TTL, CMOS, etc.) applied to the inhibit pin. No output voltage overshoot will occur, when the converter is turned on. If the inhibit function is not required, the inhibit pin should be connected to Vi– to enable the output (active low logic, fail safe). Voltage on pin i: Converter operating:

–10 V to 0.8 V 2.4 V to Vi max (<75 V) or

Converter inhibited:

pin i left open-circuit.

Option Z Open frame and not lacquered. This option can be chosen for mounting onto a mother board, which is subject to be lacquered. See Protection Degree and Cleaning Liquids (page 18).

Option G or -G Products RoHS-compliant for all 6 substances. See RoHS- Compliant Models (page 3) for the correct denotation.

PDF page 19 diagram

Fig. 24 DIN-rail mounting support DMBIMX15

NUCLEAR AND MEDICAL APPLICATIONS - These products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. Copyright © 2017, Bel Power Solutions Inc. All rights reserved.