ILR SCHURTER
Document overview
- PDF pages: 1
Technical content
Page 1
Pulse Transformers
Cost optimized pulse transformers for THT mounting, short rise time

Description
- High insulation rating (>2.2 kVAC) between the primary and the secondary windings - Small coupling capacitances between primary and secondary windings limit transient feedback from the power supply side to the control electronics - Cost optimized design - The defined partial discharge voltage guarantees an effecively unlimited serviceable live Standards - VDE 110b
Technical Data Rated voltage
up to 500 VAC
Voltage Time Integral
150 - 300 Vµs
Pulse Rise Time
0.1 - 0.3 µs
Turns Ratio
1:1, 2:1, 3:1, 1:1:1
Terminal technic
THT
Weight
7 g
Material: Housing
Plastics
Sealing Compound
UL 94V-0
Dimensions Case 05-7
max. 17.5
max. 11.5

1) Prim.
Variants Tr [μs] Iign [A] UVAC [V] Uisol Us x Tw Ls [mH] RP [Ω] RS [Ω] Turns Ratio
[Vμs] [kV]
1:1 0.2 1.0 500 3.2 300 2.5 0.7 0.7
ILR
www.schurter.com/pg85
Applications
- Galvanic separation of drive- and power-circuit - Mainly used in ignition circuits with Thyristors, Triacs, power transistors and IGBT's - DC/DC converters - Line coupling transformers in high speed data transmission References General Product Information Weblinks Approvals, RoHS, CHINA-RoHS, e-Store, Distributor-Stock-Check
Climatic Category
25/100/21 acc. to IEC 60068-1
Allowable Operation Temp.
-25 °C to 100 °C
Case 05-8
max. 17.5 max. 11.5

1) Prim.
CC [pF] Pm [W]
Weight [g] Packing unit [pcs.]
Housing Order Number
60 0.5 7 50 05-7 ILR-11-0001
The specifications, descriptions and illustrations indicated in this document are based on
EMC Products
current information. All content is subject to modifications and amendments.