IBC Module
5:1 Intermediate Bus Converter Module: Up to 750 W Output


Page 1 of 14
Page 2
SPECIFICATIONS
All specifications valid at 48 VIN , 100% rated load and 25 °C ambient, unless otherwise indicated.

[a] Does not exceed IPC-9592 derating guidelines. At 70 °C ambient, full power operation may exceed IPC-9592 guidelines, but does not exceed component ratings, does not activate OTP and does not compromise reliability.
Page 2 of 14
Page 3
All specifications valid at 48 VIN, 100% rated load and 25 °C ambient, unless otherwise indicated.


Page 3 of 14
Page 4

IPC-9592A, Based on Class II Category 2 the following detail is applicable. – Pre-conditioning required

Page 4 of 14
Page 5
WAVEFORMS


Figure 2 — Efficiency vs. output current, 55 °C ambient
Figure 1 — Efficiency vs. output current, 25 °C ambient


Figure 4 — Inrush current at high line 15% load; 5 A/div,
Figure 3 — Efficiency vs. output current, 70 °C ambient
Max load capacitance


Figure 6 — Turn on delay time;
Figure 5 — Input reflected ripple current at nominal line, full load.
VIN turn on delay at nominal line, 15% load
See Fig 22 for setup.
Page 5 of 14
Page 6
WAVEFORMS (CONT.)


Figure 8 — Output voltage rise time at nominal line, 10% load
Figure 7 — Turn on delay time; Enable turn on delay at nominal line,
0 load capacitance
15% load, 0 load capacitance


Figure 10 — Undershoot at turn off at nominal line, 15% load
Figure 9 — Overshoot at turn on at nominal line, 15% load
0 load capacitance
0 load capacitance


Figure 12 — Load transient response; Full load to 75%; nominal line
Figure 11 — Load transient response; nominal line Load step 75–100%
Page 6 of 14
Page 7
WAVEFORMS (CONT.)

Figure 13 — Load transient response; nominal line
Load step 0–25%; 10 A/div

Figure 15 — Input transient response; Vin step low line to high line at full load

Figure 17 — Three module parallel array test. Vout change when one
module is disabled. Nominal Vin, Iout = 140 A
Page 7 of 14

Figure 14 — Load transient response; 25–0%; nominal line

Figure 16 — Output ripple; Nominal line, full load

Figure 18 — Three module parallel array test. Vout change with two
modules operating and a third module enabled. Nominal Vin, Iout = 140 A
Page 8
WAVEFORMS (CONT.)

Figure 19 — Maximum output power derating vs ambient air temperature.
Transverse airflow, Board and junction temperatures <125 °C. Tested with IBC evaluation board IB048Q096T70N1-CB

Figure 21 — Test circuit; inrush current overshoot

Figure 23 — Test circuit; output voltage ripple
Page 8 of 14

Figure 20 — Maximum output power derating vs ambient air temperature.
Longitudinal airflow, Board and junction temperatures <125 °C. Tested with IBC evaluation board IB048Q096T70N1-CB

Figure 22 — Test circuit; input reflected ripple current
Page 9
THERMAL DATA

Figure 24 — Thermal plot, 200 LFM, 25 °C, 48 Vin, 670 W output power

Figure 26 — Thermal plot, 400 LFM, 25 °C, 48 Vin, 670 W output power

Figure 28 — Thermal plot, 600 LFM, 25 °C, 48 Vin, 670 W output power
Page 9 of 14

Figure 25 — Thermal plot, 200 LFM, 25 °C, 48 Vin, 670 W output power

Figure 27 — Thermal plot, 400 LFM, 25 °C, 48 Vin, 670 W output power

Figure 29 — Thermal plot, 600 LFM, 25 °C, 48 Vin, 670 W output power
Page 10
PIN / CONTROL FUNCTIONS

+In / -In – DC Voltage Input Pins
The IBC input voltage range should not be exceeded. An internal undervoltage/overvoltage lockout function prevents operation outside of the normal operating input range. The IBC turns on within an input voltage window bounded by the “Input under-voltage turn-on” and “Input over-voltage turn-off” levels, as specified. The IBC may be protected against accidental application of a reverse input voltage by the addition of a rectifier in series with the positive input, or a reverse rectifier in shunt with the positive input located on the load side of the input fuse.
The connection of the IBC to its power source should be implemented with minimal distribution inductance. If the interconnect inductance exceeds 100 nH, the input should be bypassed with a RC damper to retain low source impedance and stable operation. With an interconnect inductance of 200 nH, the RC damper may be 47 μF in series with 0.3 Ω. A single electrolytic or equivalent low-Q capacitor may be used in place of the series RC bypass.
EN - Enable/Disable
Negative Logic Option
If the EN port is left floating, the IBC output is disabled. Once this port is- pulled lower than 0.8 Vdc with respect to –In, the output is enabled. The EN port can be driven by a relay, opto-coupler, or open collector transistor. Refer to Figures 6 and 7 for the typical enable / disable characteristics. This
Figure 30 — IBC Pin Designations
port should not be toggled at a rate higher than 1 Hz. The EN port should also not be driven by or pulled up to an external voltage source.
Positive Logic Option
If the EN port is left floating, the IBC output is enabled. Once this port is pulled lower than 1.4 Vdc with respect to –In, the output is disabled. This action can be realized by employing a relay, opto-coupler, or open collector transistor. This port should not be toggled at a rate higher than 1 Hz.
The EN port should also not be driven by or pulled up to an external voltage source. The EN port can source up to 2 mA at 5 Vdc. The EN port should never be used to sink current.
If the IBC is disabled using the EN pin, the module will attempt to restart approximately every 250ms. Once the module has been disabled for at least 250ms, the turn on delay after the EN pin is enabled will be as shown in Figure 7.
+Out / -Out – DC Voltage Output Pins
Total load capacitance at the output of the IBC should not exceed the specified maximum. Owing to the wide bandwidth and low output impedance of the IBC, low frequency bypass capacitance and significant energy storage may be more densely and efficiently provided by adding capacitance at the input of the IBC.
Page 10 of 14
Page 11
APPLICATIONS NOTE
Parallel Operation
The IBC will inherently current share when operated in an array. Arrays may be used for higher power or redundancy in an application. Current sharing accuracy is maximized when the source and load impedance presented to each IBC within an array are equal. The recommended method to achieve matched impedances is to dedicate common copper planes within the PCB to deliver and return the current to the array, rather than rely upon traces of varying lengths. In typical applications the current being delivered to the load is larger than that sourced from the input, allowing narrower traces to be utilized on the input side if necessary. The use of dedicated power
planes is, however, preferable.
One or more IBCs in an array may be disabled without adversely affecting operation or reliability as long as the load does not exceed the rated power of the enabled IBCs.
The IBC power train and control architecture allow bi-directional power transfer, including reverse power processing from the IBC output to its input. The IBC’s ability to process power in reverse improves the IBC transient response to an output load dump.
Thermal Considerations
The temperature distribution of the VI Brick can vary significantly with its input/output operating conditions, thermal management and environmental conditions. Although the PCB is UL rated to 130 °C, it is recommended that PCB temperatures be maintained at or below 125 °C. For maximum long term reliability, lower PCB temperatures are recommended for continuous operation, however, short periods of operation at 125 °C will not negatively impact performance or reliability.
WARNING: Thermal and voltage hazards. The IBC can operate with surface temperatures and operating voltages that may be hazardous to personnel. Ensure that adequate protection is in place to avoid inadvertent contact.
PART NUMBERING
Input Impedance Recommendations
To take full advantage of the IBC capabilities, the impedance presented to its input terminals must be low from DC to approximately 5 MHz. The source should exhibit low inductance and should have a critically damped response. If the interconnect inductance is excessive, the IBC input pins should be bypassed with an RC damper (e.g., 47 μF in series with 0.3 Ω) to retain low source impedance and proper operation. Given the wide bandwidth of the IBC, the source response is generally the limiting factor in the overall system response.
Anomalies in the response of the source will appear at the output of the IBC multiplied by its K factor. The DC resistance of the source should be kept as low as possible to minimize voltage deviations. This is especially important if the IBC is operated near low or high line as the overvoltage/undervoltage detection circuitry could be activated.
Input Fuse Recommendations
The IBC is not internally fused in order to provide flexibility in configuring power systems. However, input line fusing of VI Bricks must always be incorporated within the power system. A fast acting fuse should be placed in series with the +In port. See safety agency approvals.
Application Notes
For IBC and VI Brick application notes on soldering, thermal management, board layout, and system design visit vicorpower.com.

Page 11 of 14
Page 12
MECHANICAL DRAWINGS

Figure 31 — IBC Outline drawing

Figure 32 — IBC outline drawing - baseplate option
Page 12 of 14
Page 13
MECHANICAL DRAWINGS

Figure 33 — IBC PCB recommended hole pattern
Page 13 of 14
Page 14
Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and ac- cessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom power systems.
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication. Vicor reserves the right to make changes to any products, specifications, and product descriptions at any time without notice. Information published by Vicor has been checked and is believed to be accurate at the time it was printed; however, Vicor assumes no responsibility for inaccuracies. Testing and other quality controls are used to the extent Vicor deems necessary to support Vicor’s product warranty. Except where mandated by government requirements, testing of all
parameters of each product is not necessarily performed. Specifications are subject to change without notice.
Vicor’s Standard Terms and Conditions
All sales are subject to Vicor’s Standard Terms and Conditions of Sale, which are available on Vicor’s webpage or upon request.
Product Warranty
In Vicor’s standard terms and conditions of sale, Vicor warrants that its products are free from non-conformity to its Standard Specifications (the “Ex- press Limited Warranty”). This warranty is extended only to the original Buyer for the period expiring two (2) years after the date of shipment and is not transferable. UNLESS OTHERWISE EXPRESSLY STATED IN A WRITTEN SALES AGREEMENT SIGNED BY A DULY AUTHORIZED VICOR SIGNATORY, VICOR DISCLAIMS ALL REPRESENTATIONS, LIABILITIES, AND WARRANTIES OF ANY KIND (WHETHER ARISING BY IMPLICATION OR BY OPERATION OF LAW) WITH RE- SPECT TO THE PRODUCTS, INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OR REPRESENTATIONS AS TO MERCHANTABILITY, FITNESS FOR
PARTICULAR PURPOSE, INFRINGEMENT OF ANY PATENT, COPYRIGHT, OR OTHER INTELLECTUAL PROPERTY RIGHT, OR ANY OTHER MATTER.
This warranty does not extend to products subjected to misuse, accident, or improper application, maintenance, or storage. Vicor shall not be liable for collateral or consequential damage. Vicor disclaims any and all liability arising out of the application or use of any product or circuit and assumes no liability for applications assistance or buyer product design. Buyers are responsible for their products and applications using Vicor products and components. Prior to using or distributing any products that include Vicor components, buyers should provide adequate design, testing and operating safeguards. Vicor will repair or replace defective products in accordance with its own best judgment. For service under this warranty, the buyer must contact
Vicor to obtain a Return Material Authorization (RMA) number and shipping instructions. Products returned without prior authorization will be re- turned to the buyer. The buyer will pay all charges incurred in returning the product to the factory. Vicor will pay all reshipment charges if the product was defective within the terms of this warranty.
Life Support Policy
VICOR’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF VICOR CORPORATION. As used herein, life support de- vices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in a significant injury to the user. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the
failure of the life support device or system or to affect its safety or effectiveness. Per Vicor Terms and Conditions of Sale, the user of Vicor products and components in life support applications assumes all risks of such use and indemnifies Vicor against all liability and damages.
Intellectual Property Notice
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating to the products described in this data sheet. No license, whether express, implied, or arising by estoppel or otherwise, to any intellectual property rights is granted by this document. Interested parties should contact Vicor's Intellectual Property Department. The products described on this data sheet are protected by the following U.S. Patents Numbers: 5,945,130; 6,403,009; 6,710,257; 6,911,848; 6,930,893; 6,934,166; 6,940,013; 6,969,909; 7,038,917; 7,166,898; 7,187,263; 7,361,844; D496,906; D505,114; D506,438; D509,472; and for use under 6,975,098 and 6,984,965.