SafeSite ® LED Area Light for Indoor and Outdoor Hazardous Locations

SafeSite® LED Area Light www.dialight.com2 Features & Benefits

  • L70 rated for >100,000 hours @ 25°C
  • 5 year full performance warranty
  • Instant on/off operation
  • Superior color rendering index compared to HPS, LPS, MV
  • Mercury free
  • Resistant to shock and vibration
  • Temperature compensation technology for longer life
  • Factory sealed
  • Low T rating compared to traditional fixtures
  • Wide Throw (Aisle Way) optic model available View the full case studies at: Diamond Pet Foods - www.dialight.com/news/details/diamond_pet_foods_case_study LANXESS - www.dialight.com/news/details/LANXESS_case_study MedSafe - www.dialight.com/news/details/medsafe_case_study About Dialight Dialight (LSE: DIA.L) is leading the energy efficient LED lighting revolution around the world for industrial and hazardous areas as well as transportation and infrastructure applications. For 40 years it has been committed to the development of LED lighting solutions that enable organizations to vastly reduce energy use and maintenance needs, improve safety, ease disposal and reduce CO2 emissions. Value Proposition
  • Improve safety, color quality
  • Improve temperature rating (T-rating)
  • Lower total cost of ownership, quick ROI
  • Lower energy consumption by > 50%
  • Significantly reduce CO2 emissions History at a Glance 1938 → Dialight founded in Brooklyn, NY 1971 → LED Circuit Board Indicator 1994 → LED Transit Vehicle Signals 1995 → LED Traffic Signals 2000 → FAA certified LED Obstruction Lights 2007 → LED Lighting for Hazardous Locations 2009 → LED High Bay Fixtures 2012 → Full performance 10-year warranty 2013 → Controls for LED Lighting 2014 → 125 Lumens per Watt SafeSite®
  • LED lighting for hazardous locations DuroSite®
  • LED lighting for general Industrial locations Vertically Focused Regulated Primary Markets
  • Oil, Gas & Petrochemical
  • Power Generation
  • Mining
  • Chemical
  • Pharmaceutical
  • Water & Sewage
  • Food & Beverage Secondary Markets
  • Manufacturing
  • Warehousing
  • Cold Storage
  • Data Centers

SafeSite® LED Area Light Class I Div. 2 Mechanical Information Fixture Weight: 10 lbs (4.5 kg) - Polycarbonate lens models 12 lbs (5.5 kg) - Glass lens models Shipping Weight: 12 lbs (5.5 kg) - Polycarbonate lens models 14 lbs (6.3 kg) - Glass lens models Mounting: (1) Threaded 3/4” NPT rear (Units with retrofit adaptors also available) Cabling: 10' (3.5m) SOOW Power Cord Electrical specifications Operating Voltage: 100 - 277V AC, 50/60 Hz 347 - 480V AC, 50/60 Hz Power Consumption: See ordering information Operating Temp: -40°F to +149°F (-40°C to +65°C) Harmonics: IEC 61000-3-2 Noise Requirements/ EMC: FCC Title 47, Subpart B, Section 15, class A device. RF Immunity; 10V/m, 80MHz-1GHz Surge Protection 100 - 277V AC 50/60Hz: 1 kV line to line 2 kV line to ground 347 - 480V AC 50/60Hz: 6 kV line to line 6 kV line to ground THD 100 - 277V AC 50/60Hz: <20% 347 - 480V AC 50/60Hz: <20% Power Factor: > 0.9 Construction Housing: Powder coated copper free aluminum Finish: Polyester / epoxy powder coat gray RAL 7040 for superior corrosion resistance Lens: HZD - Hard coated polycarbonate (or glass) HZF - Polycarbonate with antistatic coating Photometric Information CRI: 70 CCT Standard: 5,000K (cool white) 4,000K (neutral white) Optics: 180° forward throw 360° circular pattern Wide Throw (Aisle Way) pattern IES Files: Available upon request All values typical unless otherwise stated All Lumen Values are typical (tolerance +/- 10%) Certifications

  • Class I, Div 2, Groups A, B, C, D
  • Class II, Div 1
  • Class II, Div 2
  • Class III, Div 1
  • Class III, Div 2
  • UL 844
  • UL 1598/A
  • CSA 22.2 No. 137-M1981
  • ABS Design Assessed: # 12-HS942957-PDA
  • IP 66
  • NEMA 4X Application: The SafeSite® LED area light represents the future of energy efficient \\ facility illumination for hazardous locations worldwide. The Class I, Div 2 LED area lighting fixture consumes at least 50% less energy compared to traditional HID light sources, while reducing maintenance and carbon emissions. This light incorporates both cutting edge LED technology along with proprietary optics to achieve area lighting comparable with other traditional light sources. Whether your application is in a refinery, oil platform, chemical plant or any other Class I, Div 2 application, this fixture offers improved performance across the board. 10.6 [270] 9.7 [245] 6.0 [152] 6.6 [169] Ø.213 [5,41]

4 PLACES

3/4” NPT REAR ENTRANCE 2.0[51] Dimensions in Inches [mm] Patent Pending Temperature Ratings Ambient Temperature Range T4a Temperature Code Ambient Temperature Range T5 Temperature Code www.dialight.com 3

SafeSite® LED Area Light Class I Div. 1 / Class II Div. 1 Application: The SafeSite® LED area light represents the future of energy efficient facility illumination for hazardous locations worldwide. The Class I, Div 1 LED area lighting fixture consumes at least 50% less energy compared to traditional HID light sources, while reducing maintenance and carbon emissions. This light incorporates both cutting edge LED technology along with proprietary optics to achieve area lighting comparable with other traditional light sources. Whether your application is in a refinery, oil platform, chemical plant or any other Class I, Division 1 application, this fixture offers improved performance across the board. 10.7 [272] 9.7 [246] 6.0 [152] 5.8 [148] Ø.213 [5,41] Ø.197 [5] 2.0 [51] Patent Pending Certifications

  • Class I, Div 1, Groups B, C, D
  • Class II, Div 1, Groups E, F, G
  • UL 844
  • UL 1598/A
  • CSA 22.2 No. 137-M1981
  • CSA 22.2 No. 25-1966
  • ABS Design Assessed: # 12-HS942957-PDA
  • IP 66
  • NEMA 4X www.dialight.com4 Temperature Ratings Ambient Temperature Range T4a Temperature Code Ambient Temperature Range T5 Temperature Code Mechanical Information Fixture Weight: 14.5 lbs (6.58 kg) Shipping Weight: 16.5 lbs (7.48kg) Mounting: (1) Threaded 3/4” NPT rear Cabling: 10' (3.5m) SOOW Power Cord Electrical specifications Operating Voltage: 100 - 277V AC, 50/60 Hz 347 - 480V AC, 50/60 Hz Power Consumption: See ordering information Operating Temp: -40°F to +149°F (-40°C to +65°C) Harmonics: IEC 61000-3-2 Noise Requirements/ EMC: FCC Title 47, Subpart B, Section 15, class A device. RF Immunity; 10V/m, 80MHz-1GHz Surge Protection 100 - 277V AC 50/60Hz: 1 kV line to line 2 kV line to ground 347 - 480V AC 50/60Hz: 6 kV line to line 6 kV line to ground THD 100 - 277V AC 50/60Hz: <20% 347 - 480V AC 50/60Hz: <20% Power Factor: > 0.9 Construction Housing: Powder coated copper free aluminum Finish: Polyester / epoxy powder coat gray RAL 7040 for superior corrosion resistance Lens: Glass Photometric Information CRI: 70 CCT Standard: 5,000K (cool white) 4,000K (neutral white) Optics: 180° forward throw 360° circular pattern IES Files: Available upon request All values typical unless otherwise state All Lumen Values are typical (tolerance +/- 10%) Dimensions in Inches [mm]

1180° optical pattern models are optimized for a 45° mounting angle 2Part numbers listed in the above table are cool white. For neutral white model replace the 5th character with N Ex: HZF2C2N becomes HZF2N2N 3All lumen values are typical (tolerance +/- 10%) 4Part numbers listed in the above table are 100-277 VAC. For 347-480 VAC model replace the 6th character with 9 Ex: HZF2C9N For Dialight’s complete list of DLC qualified products, please click this link: www.dialight.com/Assets/News_And_Events/DLC_Par t_Number_List.xls SafeSite® LED Area Light

Ordering Information

www.dialight.com 5 Part Number CID1 CID2 CIID1 CIID2 CIIID1 CIIID2 Voltage Group B (Hydrogen) Optical Pattern1 Lens CCT2 Lumen3 Wattage LPW Class I, Div 2 Fixtures - 100 - 277V AC HZDFC2G • 100 - 277V AC 360 Glass CW 7,250 69 105 HZD9C2G • 100 - 277V AC 360 Glass CW 6,000 58 103 HZD5C2G • 100 - 277V AC 360 Glass CW 5,200 48 108 HZD3C2G • 100 - 277V AC 360 Glass CW 4,100 38 108 HZD1C2G • 100 - 277V AC 360 Glass CW 2,200 21 105 HZDFC2N • 100 - 277V AC 360 Polycarbonate CW 6,750 69 98 HZD9C2N • 100 - 277V AC 360 Polycarbonate CW 6,000 58 103 HZD5C2N • 100 - 277V AC 360 Polycarbonate CW 5,000 48 104 HZD3C2N • 100 - 277V AC 360 Polycarbonate CW 4,000 38 105 HZD1C2N • 100 - 277V AC 360 Polycarbonate CW 2,200 21 105 HZDEC2G • 100 - 277V AC 180 Glass CW 6,750 69 98 HZD8C2G • 100 - 277V AC 180 Glass CW 5,700 58 98 HZD4C2G • 100 - 277V AC 180 Glass CW 4,700 48 98 HZD2C2G • 100 - 277V AC 180 Glass CW 3,700 38 97 HZD0C2G • 100 - 277V AC 180 Glass CW 2,200 21 105 HZDEC2N • 100 - 277V AC 180 Polycarbonate CW 6,500 69 94 HZD8C2N • 100 - 277V AC 180 Polycarbonate CW 5,600 58 97 HZD4C2N • 100 - 277V AC 180 Polycarbonate CW 4,700 48 98 HZD2C2N • 100 - 277V AC 180 Polycarbonate CW 3,700 38 97 HZD0C2N • 100 - 277V AC 180 Polycarbonate CW 2,200 21 105 HZDWC2N • 100 - 277V AC Wide Throw Polycarbonate CW 4,100 60 68

Part Number CID1 CID2 CIID1 CIID2 CIIID1 CIIID2 Voltage Group B (Hydrogen) Optical Pattern1 Lens CCT2 Lumen3 Wattage LPW Class I, Div 2 / Class II, Div 1 / Class II, Div 2 / Class III, Div 1 / Class III, Div 2 Fixtures - 100 - 277V AC HZFFC2N ••• • • 100 - 277V AC 360 Polycarbonate CW 6,750 69 98 HZF9C2N ••• • • 100 - 277V AC 360 Polycarbonate CW 6,000 58 103 HZF5C2N ••• • • 100 - 277V AC 360 Polycarbonate CW 5,000 48 104 HZF3C2N ••• •• 100 - 277V AC 360 Polycarbonate CW 4,000 38 105 HZF1C2N ••• •• 100 - 277V AC 360 Polycarbonate CW 2,200 21 105 HZFEC2N ••• • • 100 - 277V AC 180 Polycarbonate CW 6,500 69 97 HZF8C2N ••• • • 100 - 277V AC 180 Polycarbonate CW 5,600 58 97 HZF4C2N ••• • • 100 - 277V AC 180 Polycarbonate CW 4,700 48 98 HZF2C2N ••• • • 100 - 277V AC 180 Polycarbonate CW 3,700 38 97 HZF0C2N ••• • • 100 - 277V AC 180 Polycarbonate CW 2,200 21 105 HZFWC2N ••• • • 100 - 277V AC Wide Throw Polycarbonate CW 4,100 60 68 Class I, Div 1 / Class II Div. 1 Fixtures - 100 - 277V AC HZCFC2N • • 100 - 277V AC 360 Glass CW 7,250 69 105 HZC9C2N •• 100 - 277V AC 360 Glass CW 6,000 58 103 HZC5C2N •• 100 - 277V AC 360 Glass CW 5,000 48 107 HZC3C2N •• 100 - 277V AC 360 Glass CW 4,100 38 108 HZC1C2N •• 100 - 277V AC 360 Glass CW 2,200 21 105 HZP9C2N •• 100 - 277V AC • 360 Glass CW 6,100 58 105 HZP5C2N •• 100 - 277V AC • 360 Glass CW 5,200 48 108 HZP3C2N •• 100 - 277V AC • 360 Glass CW 4,100 38 108 HZP1C2N •• 100 - 277V AC • 360 Glass CW 2,200 21 105 HZCEC2N •• 100 - 277V AC 180 Glass CW 6,750 69 98 HZC8C2N •• 100 - 277V AC 180 Glass CW 5,700 58 98 HZC4C2N •• 100 - 277V AC 180 Glass CW 4,700 48 98 HZC2C2N •• 100 - 277V AC 180 Glass CW 3,700 38 97 HZC0C2N •• 100 - 277V AC 180 Glass CW 2,200 21 105 HZP8C2N •• 100 - 277V AC • 180 Glass CW 5,700 58 98 HZP4C2N •• 100 - 277V AC • 180 Glass CW 4,700 48 98 HZP2C2N •• 100 - 277V AC • 180 Glass CW 3,700 38 97 HZP0C2N •• 100 - 277V AC • 180 Glass CW 2,200 21 105 1180° optical pattern models are optimized for a 45° mounting angle 2Part numbers listed in the above table are cool white. For neutral white model replace the 5th character with N Ex: HZF2C2N becomes HZF2N2N 3All lumen values are typical (tolerance +/- 10%) 4Part numbers listed in the above table are 100-277 VAC. For 347-480 VAC model replace the 6th character with 9 Ex: HZF2C9N For Dialight’s complete list of DLC qualified products, please click this link: www.dialight.com/Assets/News_And_Events/DLC_Par t_Number_List.xls SafeSite® LED Area Light 6 www.dialight.com

www.dialight.com SafeSite® LED Area Light Part Number Description Kit Includes Stanchion Mount Junction Box - Class I Div. 2, Class II Div. 1, CLass II Div. 2 HZXSTAN100S 1.00" ( 1.315" Pole OD) Slip-Fit Stanchion Mount Junction Box Junction box mounting hardware (requires bracket HZXW3 or HZXW7 not included ) HZXSTAN125S 1.25" ( 1.660" Pole OD) Slip-Fit Stanchion Mount Junction Box HZXSTAN150S 1.50" ( 1.900" Pole OD) Slip-Fit Stanchion Mount Junction Box HZXSTAN200S 2.00" ( 2.375" Pole OD) Slip-Fit Stanchion Mount Junction Box HZXSTAN100T 1.00" ( 1.315" Pole OD) NPT Threaded Stanchion Mount Junction Box HZXSTAN125T 1.25" ( 1.660" Pole OD) NPT Threaded Stanchion Mount Junction Box HZXSTAN150T 1.50" ( 1.900" Pole OD) NPT Threaded Stanchion Mount Junction Box HZXSTAN200T 2.00" ( 2.375" Pole OD) NPT Threaded Stanchion Mount Junction Box Wall/Pole Mount Junction Box - Class I Div. 2 HZXJB075 0.75" Ceiling / Wall / Pole Mount Junction Box Junction box HZXJB100 1.00" Pole Mount Junction Box HZXJB125 1.25" Pole Mount Junction Box HZXJB150 1.50" Pole Mount Junction Box Wall/Pole Mount Junction Box and Photocell - Class I Div. 2 HZXJB075PC1 0.75" Ceiling / Wall / Pole Mount Junction Box - with 120V AC Photocell Junction box 120V AC photocell HZXJB100PC1 1.00" Pole Mount Junction Box - with 120V AC Photocell HZXJB125PC1 1.25" Pole Mount Junction Box - with 120V AC Photocell HZXJB150PC1 1.50" Pole Mount Junction Box - with 120V AC Photocell Mounting Brakets (0, 45, 90 angles) HZXW3 Stainless steel bracket Bracket Mounting hardwareHZXW7 Aluminum bracket HZXW4 Stainless steel bracket with pipe clamp Bracket Pipe clamp Mounting hardwareHZXW8 Aluminum bracket with pipe clamp Safety Cable Kit HZXSAFEKIT Safety cable kit

2 Eyelets

2 Safety cables

HZXSAFETABS Safety Tabs 2 Eyelets Mounting Hardware Conduit Pipe Clamp Stanchion Junction Box

www.dialight.com HZXW3, HZXW4, HZXW7, AND HZXW8 .25" thick; HZXW4 and HZWX8 will mount to 1.5" conduit and comes with pipe mount clamps. SafeSite® LED Area Light Bracket Dimensions HZXSTANXXXX HZXJBXXX and HZXJBXXXXXX HZXSAFEKIT and HZXSAFETABS HZXSAFETABS & HZXSAFEKIT (Run properly rated secondary retention cable through hole in optional safety tab eyelets)

www.dialight.com 9 SafeSite® LED Area Light Mounting Options Part Number1 Description Kit Includes HZXTHAP Retrofit adapter (see chart below for compatability) Retrofit wiring box HZXTHCH Retrofit adapter (see chart below for compatability) Retrofit wiring box HZXTHKL Retrofit adapter (see chart below for compatability) Retrofit wiring box HZXTHG Retrofit adapter (see chart below for compatability) Retrofit wiring box 1HZFXXXX and HZDXXXX models can be ordered with factory installed retrofit adapter by adding C, A, K, or G to the end of the part number. HZD8C2N becomes HZD8C2NC. For more information please refer to www.dialight.com/assets/brochures_and_catalogs/illumination/mdtfhzralx001.pdf Retrofit Options (Available factory installed on fixtures) Mounting Compatibility HZXTHAP Pendant Ceiling Wall Stanchion KPA-75 KPC-75 KPWB-75 KPS-125 KPA-100 KPC-100 KPWB-100 KPS-150 KPAF-75 KPST-125 KPAF-100 KPST-150 KPCH-75 KPCH-100 HZXTHCH Pendant Ceiling Wall Stanchion Quad Mount APM2 CM2 TWM2 JM5 QM25 APM3 CM3 TWM3 PM5 HPM2 HZXTHKL Pendant Ceiling Wall Stanchion VMA2B VMX2B VMB2B VMD4B VMA3B VMX3B VMB3B VMD5B VMC2B VMX6B VMS5B VMC3B VMX7B VMF2B VMX8B VMF3B VMX9B Retrofit Adapter HZXTHG Pendant Ceiling Wall Stanchion Quad Mount 3P 3F 3C 3W 5S 4P 4F 4C 4W 6S

Class I, Div 2 Models SafeSite® LED Area Light Mounting Height Lumens Wattage lm/W Mounting Heights 7,000 69 101 20’ 10’ 6,000 58 103 5,000 48 104 4,000 38 105 2,200 21 105 Iso-Illuminance Candela Plots HZD8C2N - 180o Pattern 180 o Pattern Mounted at 45o Mounting Height Multiplier 10 4.000 15’ 1.778 20’ 1.000 25’ 0.640 Examples shown are mounted at 20 ft Distance of grid is equal to Mounting Height HZD9C2N - 360o Pattern 360 o Optical Pattern Mounting Height Multiplier 10 4.000 15’ 1.778 20’ 1.000 25’ 0.640 Examples shown are mounted at 20 ft Distance of grid is equal to Mounting Height HZD4C2N - 180o Pattern 180 o Pattern Mounted at 45o Mounting Height Multiplier 10 2.250 15’ 1.000 20’ 0.563 25’ 0.360 Examples shown are mounted at 15 ft Distance of grid is equal to Mounting Height www.dialight.com10

HZD5C2N - 360o Pattern 360 o Optical Pattern Mounting Height Multiplier 10’ 2.250 15’ 1.000 20’ 0.563 25’ 0.360 Examples shown are mounted at 15 ft Distance of grid is equal to Mounting Height SafeSite® LED Area Light Measurement Data Iso-Illuminance Candela Plots HZD2C2N - 180o Pattern 180 o Pattern Mounted at 45o Mounting Height Multiplier 10’ 1.000 15’ 0.444 20’ 0.250 25’ 0.160 Examples shown are mounted at 10 ft Distance of grid is equal to Mounting Height HZD3C2N - 360o Pattern 360 o Optical Pattern Mounting Height Multiplier 10’ 1.000 15’ 0.444 20’ 0.250 25’ 0.160 Examples shown are mounted at 10 ft Distance of grid is equal to Mounting Height HZDWC2N - Wide Throw (Asile Way) Pattern Wide Throw (Asile Way) pattern Mounting Height Multiplier 10’ 1.000 15’ 0.444 20’ 0.250 25’ 0.160 Examples shown are mounted at 10 ft Distance of grid is equal to Mounting Height www.dialight.com 11

www.dialight.com Iso-Illuminance Candela Plots SafeSite® LED Area Light Measurement Data Class I, Div 1 Models HZC8C2N - 180o Pattern 180 o Pattern Mounted at 45o Mounting Height Multiplier 10’ 4.000 15’ 1.778 20’ 1.000 25’ 0.640 Examples shown are mounted at 20 ft Distance of grid is equal to Mounting Hieght HZC9C2N - 360o Pattern 360 o Optical Pattern Mounting Height Multiplier 10’ 4.000 15’ 1.778 20’ 1.000 25’ 0.640 Examples shown are mounted at 20 ft Distance of grid is equal to Mounting Height HZC4C2N - 180o Pattern 180 o Pattern Mounted at 45o Mounting Height Multiplier 10’ 2.250 15’ 1.000 20’ 0.563 25’ 0.360 Examples shown are mounted at 15ft Distance of grid is equal to Mounting Height HZC5C2N - 360o Pattern 360 o Optical Pattern Mounting Height Multiplier 10’ 2.250 15’ 1.000 20’ 0.563 25’ 0.360 Examples shown are mounted at 15 ft Distance of grid is equal to Mounting Height Dialight reserves the right to make changes at any time in order to supply the best product possible. The most current version of this document will always be available at: www.dialight.com/Assets/Brochures_And_Catalogs/Illumination/MDTFHZHAZX001.pdf Warranty Statement: EXCEPT FOR THE WARRANTY EXPRESSLY PROVIDED FOR [HEREIN/ABOVE/BELOW], DIALIGHT DISCLAIMS ANY AND ALL OTHER W ARRANTIES, EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, TITLE, AND NONINFRINGEMENT. MDTFHZHAZX001_G