HGTP12N60C3 INTERSIL

Document overview

  • PDF pages: 6

Technical content

Page 1

Data Sheet

24A, 600V, UFS Series N-Channel IGBTs

The HGTP12N60C3 and HGT1S12N60C3S are MOS gated high voltage switching devices combining the best features of MOSFETs and bipolar transistors. These devices have the high input impedance of a MOSFET and the low on-state conduction loss of a bipolar transistor. The much lower on-state voltage drop varies only moderately between 25oC and 150oC.

The IGBT is ideal for many high voltage switching applications operating at moderate frequencies where low conduction losses are essential, such as: AC and DC motor controls, power supplies and drivers for solenoids, relays and contactors.

Formerly Developmental Type TA49123.

Ordering Information

PART NUMBER PACKAGE BRAND
HGTP12N60C3 TO-220AB P12N60C3
HGT1S12N60C3S TO-263AB S12N60C3

NOTE: When ordering, use the entire part number. Add the suffix 9A to obtain the TO-263AB variant in Tape and Reel, i.e., HGT1S12N60C3S9A.

Symbol

C

G

E

January 2000

File Number 4040.4

Features

  • 24A, 600V at TC = 25oC
  • 600V Switching SOA Capability
  • Typical Fall Time. . . . . . . . . . . . . . . . 230ns at TJ = 150oC
  • Short Circuit Rating
  • Low Conduction Loss

Packaging

JEDEC TO-220AB

EMITTER

COLLECTOR

GATE

COLLECTOR

(FLANGE)

JEDEC TO-263AB

COLLECTOR

(FLANGE)

GATE EMITTER

INTERSIL CORPORATION IGBT PRODUCT IS COVERED BY ONE OR MORE OF THE FOLLOWING U.S. PATENTS

4,364,073

4,417,385

4,430,792

4,443,931

4,466,176

4,516,143

4,532,534

4,587,713

4,598,461

4,605,948

4,620,211

4,631,564

4,639,754

4,639,762

4,641,162

4,644,637

4,682,195

4,684,413

4,694,313

4,717,679

4,743,952

4,783,690

4,794,432

4,801,986

4,803,533

4,809,045

4,809,047

4,810,665

4,823,176

4,837,606

4,860,080

4,883,767

4,888,627

4,890,143

4,901,127

4,904,609

4,933,740

4,963,951

4,969,027

CAUTION: These devices are sensitive to electrostatic discharge; follow proper ESD Handling Procedures.

1-888-INTERSIL or 321-724-7143 | Copyright © Intersil Corporation 2000

Page 2

Absolute Maximum Ratings TC = 25oC, Unless Otherwise Specified HGTP12N60C3, HGT1S12N60C3S UNITS Collector to Emitter Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .BVCES 600 V Collector Current Continuous At TC = 25oC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IC25 24 A At TC = 110oC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IC110 12 A Collector Current Pulsed (Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ICM 96 A Gate to Emitter Voltage Continuous. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .VGES ±20 V Gate to Emitter Voltage Pulsed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VGEM ±30 V Switching Safe Operating Area at TJ = 150oC (Figure 14) . . . . . . . . . . . . . . . . . . . . . . SSOA 24A at 600V Power Dissipation Total at TC = 25oC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PD 104 W Power Dissipation Derating TC > 25oC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.83 W/oC Reverse Voltage Avalanche Energy. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EARV 100 mJ Operating and Storage Junction Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . TJ, TSTG -40 to 150 oC Maximum Lead Temperature for Soldering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TL 260 oC Short Circuit Withstand Time (Note 2) at VGE = 15V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .tSC 4 µs Short Circuit Withstand Time (Note 2) at VGE = 10V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .tSC 13 µs CAUTION: Stresses above those listed in “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress only rating and operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. NOTES: 1. Repetitive Rating: Pulse width limited by maximum junction temperature. 2. VCE(PK) = 360V, TJ = 125oC, RG = 25Ω.
Electrical Specifications TC = 25oC, Unless Otherwise Specified
PARAMETER SYMBOL TEST CONDITIONS MIN TYP MAX UNITS
Collector to Emitter Breakdown Voltage BVCES IC = 250µA, VGE = 0V 600 - - V
Emitter-Collector Breakdown Voltage BVECS IC = 10mA, VGE = 0V 24 30 - V
Collector to Emitter Leakage Current ICES VCE = BVCES TC = 25oC - - 250 µA
VCE = BVCES TC = 150oC - - 1.0 mA
Collector to Emitter Saturation Voltage VCE(SAT) IC = IC110, VGE = 15V TC = 25oC - 1.65 2.0 V
TC = 150oC - 1.85 2.2 V
Gate to Emitter Threshold Voltage VGE(TH) IC = 250µA, VCE = VGE TC = 25oC 3.0 5.0 6.0 V
Gate to Emitter Leakage Current IGES VGE = ±20V - - ±100 nA
Switching SOA SSOA TJ = 150oC RG = 25Ω VGE = 15V L = 100µH VCE(PK) = 480V 80 - - A
VCE(PK) = 600V 24 - - A
Gate to Emitter Plateau Voltage VGEP IC = IC110, VCE = 0.5 BVCES - 7.6 - V
On-State Gate Charge QG(ON) IC = IC110, VCE = 0.5 BVCES VGE = 15V - 48 55 nC
VGE = 20V - 62 71 nC
Current Turn-On Delay Time td(ON)I TJ = 150oC, ICE = IC110, VCE(PK) = 0.8 BVCES, VGE = 15V, RG = 25Ω, L = 100µH - 14 - ns
Current Rise Time trI - 16 - ns
Current Turn-Off Delay Time td(OFF)I - 270 400 ns
Current Fall Time tfI - 210 275 ns
Turn-On Energy EON - 380 - µJ
Turn-Off Energy (Note 3) EOFF - 900 - µJ
Thermal Resistance RθJC - - 1.2 oC/W
NOTE: 3. Turn-Off Energy Loss (EOFF) is defined as the integral of the instantaneous power loss starting at the trailing edge of the input pulse and ending at the point where the collector current equals zero (ICE = 0A). The HGTP12N60C3 and HGT1S12N60C3S were tested per JEDEC standard No. 24-1 Method for Measurement of Power Device Turn-Off Switching Loss. This test method produces the true total Turn-Off Energy Loss. Turn-On losses include diode losses.

Page 3

PDF page 3 diagram

Page 4

PDF page 4 diagram

Page 5

PDF page 5 diagram

Page 6

Test Circuit and Waveform

L = 100µH

RHRP1560

RG = 25Ω

+

VDD = 480V

-

FIGURE 18. INDUCTIVE SWITCHING TEST CIRCUIT

Handling Precautions for IGBTs

Insulated Gate Bipolar Transistors are susceptible to gate-insulation damage by the electrostatic discharge of energy through the devices. When handling these devices, care should be exercised to assure that the static charge built in the handler’s body capacitance is not discharged through the device. With proper handling and application procedures, however, IGBTs are currently being extensively used in production by numerous equipment manufacturers in military, industrial and consumer applications, with virtually no damage problems due to electrostatic discharge. IGBTs can be handled safely if the following basic precautions are taken: 1. Prior to assembly into a circuit, all leads should be kept

shorted together either by the use of metal shorting springs or by the insertion into conductive material such as “ECCOSORBD LD26” or equivalent. 2. When devices are removed by hand from their carriers, the hand being used should be grounded by any suitable means - for example, with a metallic wristband. 3. Tips of soldering irons should be grounded. 4. Devices should never be inserted into or removed from circuits with power on. 5. Gate Voltage Rating - Never exceed the gate-voltage rating of VGEM. Exceeding the rated VGE can result in permanent damage to the oxide layer in the gate region. 6. Gate Termination - The gates of these devices are essentially capacitors. Circuits that leave the gate open-

circuited or floating should be avoided. These conditions can result in turn-on of the device due to voltage buildup on the input capacitor due to leakage currents or pickup. 7. Gate Protection - These devices do not have an internal monolithic zener diode from gate to emitter. If gate protection is required an external zener is recommended.

90%

10%

VGE

EOFF EON

VCE

90%

10%

ICE

td(OFF)I

trI

tfI

td(ON)I

FIGURE 19. SWITCHING TEST WAVEFORMS

Operating Frequency Information

Operating frequency information for a typical device Figure 13) is presented as a guide for estimating device performance for a specific application. Other typical frequency vs collector current (ICE) plots are possible using the information shown for a typical unit in Figures 4, 7, 8, 11 and 12. The operating frequency plot (Figure 13) of a typical device shows fMAX1 or fMAX2 whichever is smaller at each point. The information is based on measurements of a typical device and is bounded by the maximum rated junction temperature.

fMAX1 is defined by fMAX1 = 0.05/(tD(OFF)I+ tD(ON)I). Deadtime (the denominator) has been arbitrarily held to 10% of the on- state time for a 50% duty factor. Other definitions are possible. tD(OFF)I and tD(ON)I are defined in Figure 19. Device turn-off delay can establish an additional frequency limiting condition for an application other than TJM. tD(OFF)I is important when controlling output ripple under a lightly loaded condition.

fMAX2 is defined by fMAX2 = (PD - PC)/(EOFF + EON). The allowable dissipation (PD) is defined by PD = (TJM - TC)/RθJC. The sum of device switching and conduction losses must not exceed PD. A 50% duty factor was used (Figure 13) and the conduction losses (PC) are approximated by PC = (VCE x ICE)/2. EON and EOFF are defined in the switching waveforms shown in Figure 19. EON is the integral of the instantaneous power loss (ICE x VCE) during turn-on and EOFF is the integral of the instantaneous power loss (ICE x VCE) during turn-off. All tail losses are included in the calculation for EOFF; i.e. the collector current equals zero (ICE = 0).

All Intersil semiconductor products are manufactured, assembled and tested under ISO9000 quality systems certification. Intersil semiconductor products are sold by description only. Intersil Corporation reserves the right to make changes in circuit design and/or specifications at any time without notice. Accordingly, the reader is cautioned to verify that data sheets are current before placing orders. Information furnished by Intersil is believed to be accurate and reliable. However, no responsibility is assumed by Intersil or its subsidiaries for its use; nor for any infringements of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of Intersil or its subsidiaries.

For information regarding Intersil Corporation and its products, see web site www.intersil.com

ECCOSORBD™ is a Trademark of Emerson and Cumming, Inc.