DATASHEET SEARCH SITE
Document overview
- PDF pages: 8
Technical content
Page 1
FEATURES
- Fast recovery time characteristic

- Electrically isolated base plate
- Large creepage distance between terminal
- Simplified mechanical designs, rapid assembly
- UL approved file E78996
- Compliant to RoHS directive 2002/95/EC
- Designed and qualified for industrial level
DESCRIPTION/APPLICATIONS
The dual diode series configuration (HFA200FA120P) is
| PRODUCT SUMMARY | |
| V R | 1200 V |
| V (typical) F | 2.7 V |
| t (typical) rr | 150 ns |
| I at T F(DC) C | 100 A at 69 °C |
used for output rectification or freewheeling/clamping operation and high voltage application. The semiconductor in the SOT-227 package is isolated from the copper base plate, allowing for common heatsinks and compact assemblies to be built. These modules are intended for general applications such as HV power supplies, electronic welders, motor control and inverters.
| ABSOLUTE MAXIMUM RATINGS | ||||
|---|---|---|---|---|
| PARAMETER | SYMBOL | TEST CONDITIONS | MAX. | UNITS |
| Cathode to anode voltage | V R | 1200 | V | |
| Continuous forward current | I F | T = 69 °C C | 100 | A |
| Single pulse forward current | I FSM | T = 25 °C J | 900 | |
| Maximum repetitive forward current | I FRM | Rated V square wave, 20 kHz, T = 60 °C R, C | 150 | |
| Maximum power dissipation | P D | T = 25 °C C | 416 | W |
| T = 100 °C C | 166 | |||
| RMS isolation voltage | V ISOL | Any terminal to case, t = 1 minute | 2500 | V |
| Operating junction and storage temperature range | T , T J Stg | - 55 to 150 | °C | |
| ELECTRICAL SPECIFICATIONS (T = 25 °C unless otherwise specified) J | ||||||
| PARAMETER | SYMBOL | TEST CONDITIONS | MIN. | TYP. | MAX. | UNITS |
| Cathode to anode breakdown voltage | V BR | I = 100 μA R | 1200 | - | - | V |
| Forward voltage | V FM | I = 100 A F | - | 2.68 | 3.6 | |
| I = 200 A F | - | 3.37 | 4.7 | |||
| I = 100 A, T = 150 °C F J | - | 2.7 | 2.9 | |||
| Reverse leakage current | I RM | V = V rated R R | - | 10 | 75 | μA |
| T = 125 °C, V = V rated J R R | - | 2 | - | mA | ||
Page 2
| DYNAMIC RECOVERY CHARACTERISTICS (T = 25 °C unless otherwise specified) J | |||||||
| PARAMETER | SYMBOL | TEST CONDITIONS | MIN. | TYP. | MAX. | UNITS | |
| Reverse recovery time | t rr | T = 25 °C J | I = 50 A F dI /dt = - 200 A/μs F V = 200 V R | - | 150 | - | ns |
| T = 125 °C J | - | 237 | - | ||||
| Peak recovery current | I RRM | T = 25 °C J | - | 14 | - | A | |
| T = 125 °C J | - | 21 | - | ||||
| Reverse recovery charge | Q rr | T = 25 °C J | - | 1050 | - | nC | |
| T = 125 °C J | - | 2430 | - | ||||
| THERMAL - MECHANICAL SPECIFICATIONS | ||||||
| PARAMETER | SYMBOL | TEST CONDITIONS | MIN. | TYP. | MAX. | UNITS |
| Junction to case, single leg conducting | R thJC | - | - | 0.3 | °C/W | |
| Junction to case, both legs conducting | - | - | 0.15 | |||
| Case to heatsink | R thCS | Flat, greased and surface | - | 0.05 | - | |
| Weight | - | 30 | - | g | ||
| Mounting torque | - | 1.3 | - | Nm | ||
Page 3


Fig. 1 - Typical Forward Voltage Drop Characteristics
Fig. 2 - Typical Values of Reverse Current vs.
Reverse Voltage

Fig. 3 - Maximum Thermal Impedance ZthJC Characteristics


Fig. 4 - Maximum Allowable Case Temperature vs.
Fig. 5 - Forward Power Loss Characteristics
Average Forward Current
Page 4


Fig. 6 - Typical Reverse Recovery Time vs. dIF/dt
Fig. 7 - Typical Stored Charge vs. dIF/dt

Fig. 8 - Typical Peak Recovery Current vs. dIF/dt
Note (1) Formula used: TC = TJ - (Pd + PdREV) x RthJC; Pd = Forward power loss = IF(AV) x VFM at (IF(AV)/D) (see fig. 5); PdREV = Inverse power loss = VR1 x IR (1 - D); IR at VR1 = Rated VR
Page 5

Fig. 9 - Reverse Recovery Parameter Test Circuit

Fig. 10 - Reverse Recovery Waveform and Definitions
Page 6
ORDERING INFORMATION TABLE

| HF | A | 200 | FA | 120 | P |
| 1 2 3 4 5 6 | |||||

CIRCUIT CONFIGURATION

| LINKS TO RELATED DOCUMENTS | |
| Dimensions | www.vishay.com/doc?95036 |
| Packaging information | www.vishay.com/doc?95037 |
Page 7
Outline Dimensions
SOT-227
DIMENSIONS in millimeters (inches)

Notes
- Dimensioning and tolerancing per ANSI Y14.5M-1982
- Controlling dimension: millimeter
For technical questions, contact: indmodules@vishay.com
Document Number: 95036 Revision: 28-Aug-07
Page 8
Legal Disclaimer Notice
Vishay
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase, including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining applications or for any other application in which the failure of the Vishay product could result in personal injury or death. Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
Material Category Policy
Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as RoHS-Compliant fulfill the definitions and restrictions defined under Directive 2011/65/EU of The European Parliament and of the Council of June 8, 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment (EEE) - recast, unless otherwise specified as non-compliant.
Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU.
Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as Halogen-Free follow Halogen-Free requirements as per JEDEC JS709A standards. Please note that some Vishay documentation may still make reference to the IEC 61249-2-21 definition. We confirm that all the products identified as being compliant to IEC 61249-2-21 conform to JEDEC JS709A standards.
Revision: 02-Oct-12
Document Number: 91000