Bulletin PD-2.606 rev. B 05/01

HFA16PA60C

HEXFRED

Ultrafast, Soft Recovery Diode

TM

PDF page 1 diagram

Features

  • Ultrafast Recovery
  • Ultrasoft Recovery
  • Very Low IRRM
  • Very Low Qrr
  • Specified at Operating Conditions

Benefits

  • Reduced RFI and EMI
  • Reduced Power Loss in Diode and Switching
PDF page 1 diagram

Transistor

  • Higher Frequency Operation
  • Reduced Snubbing
  • Reduced Parts Count

Description

International Rectifier's HFA16PA60C is a state of the art center tap ultra fast recovery diode. Employing the latest in epitaxial construction and advanced processing techniques it features a superb combination of characteristics which result in performance which is unsurpassed by any rectifier previously available. With basic ratings of 600 volts and 8 amps per Leg continuous current, the HFA16PA60C is especially well suited for use as the companion diode for IGBTs and MOSFETs. In addition to ultra fast recovery time, the HEXFRED product line features extremely low values of peak recovery current (IRRM) and does not exhibit any tendency to "snap-off" during the tb portion of recovery. The

HEXFRED features combine to offer designers a rectifier with lower noise and significantly lower switching losses in both the diode and the switching transistor. These HEXFRED advantages can help to significantly reduce snubbing, component count and heatsink sizes. The HEXFRED HFA16PA60C is ideally suited for applications in power supplies and power conversion systems (such as inverters), motor drives, and many other similar applications where high speed, high efficiency is needed.

Absolute Maximum Ratings (per Leg)

Parameter Max Units
VR Cathode-to-Anode Voltage 600 V
IF @ TC = 100°C Continuous Forward Current (per Leg) 8 A
IFSM Single Pulse Forward Current 60
IFRM Maximum Repetitive Forward Current 24
PD @ TC = 25°C Maximum Power Dissipation 36 W
PD @ TC = 100°C Maximum Power Dissipation 14
TJ Operating Junction and -55 to +150 °C
TSTG Storage Temperature Range

1

www.irf.com

Page 2

HFA16PA60C

Bulletin PD-2.606 rev. B 05/01

Electrical Characteristics (per Leg) @ TJ = 25°C (unless otherwise specified)

Parameter Min. Typ. Max. Units Test Conditions
VBR Cathode Anode Breakdown Voltage 600 V IR = 100µA
VFM Max Forward Voltage 1.4 1.7 V IF = 8A IF = 16A See Fig. 1 IF = 8A, TJ = 125°C
1.7 2.1
1.4 1.7
IRM Max Reverse Leakage Current 0.3 5 µA VR = VR Rated See Fig. 2 TJ = 125°C, VR = 0.8 x VR Rated D Rated
100 500
CT Junction Capacitance 10 25 pF VR = 200V See Fig. 3
LS Series Inductance 8.0 nH Measured lead to lead 5mm from package body

Dynamic Recovery Characteristics (per Leg) @ TJ = 25°C (unless otherwise specified)

PDF page 2 diagram

Thermal - Mechanical Characteristics

Parameter Min Typ Max Units
Tlead! Lead Temperature 300 °C
RthJC Junction-to-Case, Single Leg Conducting Junction-to-Case, Both Legs Conducting 3.5 K/W
1.75
RthJA" Thermal Resistance, Junction to Ambient 40
RthCS# Thermal Resistance, Case to Heat Sink 0.25
Wt Weight 6 g
0.21 (oz)
Mounting Torque 6 12 Kg-cm
5 10 lbf•in

! 0.063 in. from Case (1.6mm) for 10 sec " Typical Socket Mount # Mounting Surface, Flat, Smooth and Greased

www.irf.com

2

Page 3

PDF page 3 diagram

Forward Voltage Drop - V (V)

FM

Fig. 1 - Maximum Forward Voltage Drop vs. Instantaneous Forward Current, (per Leg)

HFA16PA60C

Bulletin PD-2.606 rev. B 05/01

PDF page 3 diagram

Reverse Voltage - V (V)

R

Fig. 2 - Typical Reverse Current vs. Reverse Voltage, (per Leg)

PDF page 3 diagram

Reverse Voltage - VR ( V ) Reverse Voltage - V (V)

R

Fig. 3 - Typical Junction Capacitance vs.

PDF page 3 diagram

Page 4

HFA16PA60C

Bulletin PD-2.606 rev. B 05/01

PDF page 4 diagram

di /dt - (A/µs) f

Fig. 5 - Typical Reverse Recovery vs. dif/dt,

(per Leg)

PDF page 4 diagram

di /dt - (A/µs) f

Fig. 7 - Typical Stored Charge vs. dif/dt,

(per Leg)

4

PDF page 4 diagram

di /dt - (A/µs) f

Fig. 6 - Typical Recovery Current vs. dif/dt,

(per Leg)

PDF page 4 diagram

di /dt - (A/µs) f

Fig. 8 - Typical di(rec)M/dt vs. dif/dt, (per Leg)

www.irf.com

Page 5

HFA16PA60C

Bulletin PD-2.606 rev. B 05/01

PDF page 5 diagram

REVERSE RECOVERY CIRCUIT

PDF page 5 diagram
  1. dif/dt - Rate of change of current
  1. Qrr - Area under curve defined by trr and IRRM

through zero crossing

trr X IRRM

  1. IRRM - Peak reverse recovery current

Qrr = 2

  1. trr - Reverse recovery time measured from zero crossing point of negative
  1. di(rec)M/dt - Peak rate of change of

going IF to point where a line passing

current during tb portion of trr

through 0.75 IRRM and 0.50 IRRM extrapolated to zero current

Fig. 10 - Reverse Recovery Waveform and

Fig. 9 - Reverse Recovery Parameter Test

Definitions

Circuit

Ordering Information Table

PDF page 5 diagram

www.irf.com

5

Page 6

HFA16PA60C

Bulletin PD-2.606 rev. B 05/01

Outline Table

PDF page 6 diagram

Data and specifications subject to change without notice.

This product has been designed and qualified for Industrial Level.

Qualification Standards can be found on IR's Web site.

IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105

TAC Fax: (310) 252-7309

Visit us at www.irf.com for sales contact information. 05/01