HFA15TB60SPBF_11 VISHAY
Document overview
- PDF pages: 9
Technical content
Page 1
HEXFRED®,
Ultrafast Soft Recovery Diode, 15 A
FEATURES

- Ultrafast and ultrasoft recovery
- Very low IRRM and Qrr
- Meets MSL level 1, per J-STD-020, LF maximum peak of 260 °C
- Halogen-free according to IEC61249-2-21 definition
- Compliant to RoHS Directive 2002/95/EC
- Designed and qualified for industrial level
- AEC-Q101 qualified
BENEFITS
- Reduced RFI and EMI
- Reduced power loss in diode and switching transistor
- Higher frequency operation
- Reduced snubbing
- Reduced parts count
DESCRIPTION
| PRODUCT SUMMARY | |
| Package | TO-263AB (D2PAK), TO-262AA |
| I F(AV) | 15 A |
| V R | 600 V |
| V at I F F | 1.7 V |
| t (typ.) rr | 23 ns |
| T max. J | 150 °C |
| Diode variation | Single die |
VS-HFA15TB60SPbF, VS-HFA15TB60-1PbF is a state of the art ultrafast recovery diode. Employing the latest in epitaxial construction and advanced processing techniques it features a superb combination of characteristics which result in performance which is unsurpassed by any rectifier previously available. With basic ratings of 600 V and 15 A continuous current, the VS-HFA15TB60SPbF, VS-HFA15TB60-1PbF is especially well suited for use as the companion diode for IGBTs and MOSFETs. In addition to ultrafast recovery time, the HEXFRED® product line features extremely low values of peak recovery current (IRRM) and does not exhibit any tendency to “snap-off” during the tb
portion of recovery. The HEXFRED features combine to offer designers a rectifier with lower noise and significantly lower switching losses in both the diode and the switching transistor. These HEXFRED advantages can help to significantly reduce snubbing, component count and heatsink sizes. The HEXFRED VS-HFA15TB60SPbF, VS-HFA15TB60-1PbF is ideally suited for applications in power supplies and power conversion systems (such as inverters), motor drives, and many other similar applications where high speed, high efficiency is needed.
| ABSOLUTE MAXIMUM RATINGS | ||||
|---|---|---|---|---|
| PARAMETER | SYMBOL | TEST CONDITIONS | VALUES | UNITS |
| Cathode to anode voltage | V R | 600 | V | |
| Maximum continuous forward current | I F | T = 100 °C C | 15 | A |
| Single pulse forward current | I FSM | 150 | ||
| Maximum repetitive forward current | I FRM | 60 | ||
| Maximum power dissipation | P D | T = 25 °C C | 74 | W |
| T = 100 °C C | 29 | |||
| Operating junction and storage temperature range | T , T J Stg | - 55 to + 150 | °C | |
Page 2
| ELECTRICAL SPECIFICATIONS (T = 25 °C unless otherwise specified) J | |||||||
| PARAMETER | SYMBOL | TEST CONDITIONS | MIN. | TYP. | MAX. | UNITS | |
| Cathode to anode breakdown voltage | V BR | I = 100 μA R | 600 | - | - | V | |
| Maximum forward voltage | V FM | I = 15 A F | See fig. 1 | - | 1.3 | 1.7 | |
| I = 30 A F | - | 1.5 | 2.0 | ||||
| I = 15 A, T = 125 °C F J | - | 1.2 | 1.6 | ||||
| Maximum reverse leakage current | I RM | V = V rated R R T = 125 °C, V = 0.8 x V rated J R R | See fig. 2 | - | 1.0 | 10 | μA |
| - | 400 | 1000 | |||||
| Junction capacitance | C T | V = 200 V R | See fig. 3 | - | 25 | 50 | pF |
| Series inductance | L S | Measured lead to lead 5 mm from package body | - | 8.0 | - | nH | |
| DYNAMIC RECOVERY CHARACTERISTICS (T = 25 °C unless otherwise specified) J | |||||||
| PARAMETER | SYMBOL | TEST CONDITIONS | MIN. | TYP. | MAX. | UNITS | |
| Reverse recovery time See fig. 5 | t rr | I = 1.0 A, dI /dt = 200 A/μs, V = 30 V F F R | - | 23 | - | ns | |
| t rr1 | T = 25 °C J | I = 15 A F dI /dt = 200 A/μs F V = 200 V R | - | 50 | 60 | ||
| t rr2 | T = 125 °C J | - | 105 | 120 | |||
| Peak recovery current See fig. 6 | I RRM1 | T = 25 °C J | - | 4.5 | 6.0 | A | |
| I RRM2 | T = 125 °C J | - | 6.5 | 10 | |||
| Reverse recovery charge See fig. 7 | Q rr1 | T = 25 °C J | - | 84 | 180 | nC | |
| Q rr2 | T = 125 °C J | - | 241 | 600 | |||
| Peak rate of fall of recovery current during t b See fig. 8 | dI /dt1 (rec)M | T = 25 °C J | - | 188 | - | A/μs | |
| dI /dt2 (rec)M | T = 125 °C J | - | 160 | - | |||
| THERMAL - MECHANICAL SPECIFICATIONS | ||||||
| PARAMETER | SYMBOL | TEST CONDITIONS | MIN. | TYP. | MAX. | UNITS |
| Lead temperature | T lead | 0.063" from case (1.6 mm) for 10 s | - | - | 300 | °C |
| Thermal resistance, junction to case | R thJC | - | - | 1.7 | K/W | |
| Thermal resistance, junction to ambient | R thJA | Typical socket mount | - | - | 80 | |
| Thermal resistance, case to heatsink | R thCS | Mounting surface, flat, smooth and greased | - | 0.5 | - | |
| Weight | - | 2.0 | - | g | ||
| - | 0.07 | - | oz. | |||
| Marking device | Case style D2PAK | HFA15TB60S | ||||
| Case style TO-262 | HFA15TB60-1 | |||||
Page 3


Instantaneous Forward Current

Fig. 3 - Typical Junction Capacitance vs. Reverse Voltage

Page 4




Page 5

Fig. 9 - Reverse Recovery Parameter Test Circuit

Fig. 10 - Reverse Recovery Waveform and Definitions
Page 6
ORDERING INFORMATION TABLE

| VS- | HF | A | 15 | TB | 60 | S | TRL | PbF |
| 1 2 3 4 5 6 7 8 9 | ||||||||

| LINKS TO RELATED DOCUMENTS | |
| Dimensions | TO-263AB (D2PAK): www.vishay.com/doc?95046 |
| TO-262AA : www.vishay.com/doc?95419 | |
| Part marking information | TO-263AB (D2PAK): www.vishay.com/doc?95054 |
| TO-262AA : www.vishay.com/doc?95420 | |
| Packaging information | www.vishay.com/doc?95032 |
| SPICE model | www.vishay.com/doc?95357 |
Page 7
Outline Dimensions
D2PAK
DIMENSIONS in millimeters and inches
Conforms to JEDEC outline D2PAK (SMD-220)
B
Pad layout
A


MIN.
MIN.
2 x b
± 0.004 M B
Base
0.010 M M A B


| Gauge plane o 8° | H B | |
| L3 | L L4 | A1 |
2., 4. - Cathode
Detail “A”
- - Anode
Rotated 90 °CW Scale: 8:1

Notes (1) Dimensioning and tolerancing per ASME Y14.5 M-1994 (2) Dimension D and E do not include mold flash. Mold flash shall not exceed 0.127 mm (0.005") per side. These dimensions are measured at the outmost extremes of the plastic body (3) Thermal pad contour optional within dimension E, L1, D1 and E1 (4) Dimension b1 and c1 apply to base metal only (5) Datum A and B to be determined at datum plane H (6) Controlling dimension: inch (7) Outline conforms to JEDEC outline TO-263AB
For technical questions within your region, please contact one of the following:
Document Number: 95046
DiodesAmericas@vishay.com, DiodesAsia@vishay.com, DiodesEurope@vishay.com
Revision: 31-Mar-11
This document is subject to change without notice.
THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Page 8
Outline Dimensions
TO-262
DIMENSIONS in millimeters and inches

| SYMBOL | MILLIMETERS | INCHES | NOTES | ||
|---|---|---|---|---|---|
| MIN. | MAX. | MIN. | MAX. | ||
| A | 4.06 | 4.83 | 0.160 | 0.190 | |
| A1 | 2.03 | 3.02 | 0.080 | 0.119 | |
| b | 0.51 | 0.99 | 0.020 | 0.039 | |
| b1 | 0.51 | 0.89 | 0.020 | 0.035 | 4 |
| b2 | 1.14 | 1.78 | 0.045 | 0.070 | |
| b3 | 1.14 | 1.73 | 0.045 | 0.068 | 4 |
| c | 0.38 | 0.74 | 0.015 | 0.029 | |
| c1 | 0.38 | 0.58 | 0.015 | 0.023 | 4 |
| c2 | 1.14 | 1.65 | 0.045 | 0.065 | |
| D | 8.51 | 9.65 | 0.335 | 0.380 | 2 |
| D1 | 6.86 | 8.00 | 0.270 | 0.315 | 3 |
| E | 9.65 | 10.67 | 0.380 | 0.420 | 2, 3 |
| E1 | 7.90 | 8.80 | 0.311 | 0.346 | 3 |
| e | 2.54 BSC | 0.100 BSC | |||
| L | 13.46 | 14.10 | 0.530 | 0.555 | |
| L1 | - | 1.65 | - | 0.065 | 3 |
| L2 | 3.56 | 3.71 | 0.140 | 0.146 | |
Notes (1) Dimensioning and tolerancing as per ASME Y14.5M-1994 (2) Dimension D and E do not include mold flash. Mold flash shall not exceed 0.127 mm (0.005") per side. These dimensions are measured at the outmost extremes of the plastic body (3) Thermal pad contour optional within dimension E, L1, D1 and E1
(4) Dimension b1 and c1 apply to base metal only (5) Controlling dimension: inches (6) Outline conform to JEDEC TO-262 except A1 (maximum), b (minimum) and D1 (minimum) where dimensions derived the actual package outline
For technical questions within your region, please contact one of the following:
Document Number: 95419
DiodesAmericas@vishay.com, DiodesAsia@vishay.com, DiodesEurope@vishay.com
Revision: 04-Oct-10
Page 9
Legal Disclaimer Notice
Vishay
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase, including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining applications or for any other application in which the failure of the Vishay product could result in personal injury or death. Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk and agree to fully indemnify and hold Vishay and its distributors harmless from and against any and all claims, liabilities, expenses and damages arising or resulting in connection with such use or sale, including attorneys fees, even if such claim alleges that Vishay or its distributor was negligent regarding the design or manufacture of the part. Please contact authorized Vishay personnel to
obtain written terms and conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
Document Number: 91000 Revision: 11-Mar-11