HFA120FA60P VISHAY

Document overview

  • PDF pages: 7

Technical content

Page 1

Ultrafast Soft Recovery Diode, 60 A

FEATURES

PDF page 1 diagram
  • Fast recovery time characteristic
  • Electrically isolated base plate

RoHS

  • Large creepage distance between terminal

COMPLIANT

  • Simplified mechanical designs, rapid assembly
  • UL pending
  • Totally lead (Pb)-free
  • Designed for industrial level

DESCRIPTION

PRODUCT SUMMARY
V R 600 V
V (typical) at 125 °C F 1.4 V
Q (typical) rr 270 nC
I (typical) RRM 7.0 A
t (typical) rr 65 ns
dI /dt (typical) at 125 °C (rec)M 270 A/µs
I at T F(DC) C 40 A at 100 °C

This SOT-227 modules with HEXFRED® rectifier are available in two basic configurations. They are the antiparallel and the parallel configurations. The antiparallel configuration (HFA120EA60) is used for simple series rectifier and high voltage application. The parallel configuration (HFA120FA60) is used for simple parallel rectifier and high current application. The semiconductor in the SOT-227 package is isolated from the copper base plate, allowing for common heatsinks and compact assemblies to be built. These modules are intended for general applications such as power supplies, battery chargers, electronic welders, motor control, DC chopper, and inverters.

ABSOLUTE MAXIMUM RATINGS PER LEG
PARAMETER SYMBOL TEST CONDITIONS VALUES UNITS
Cathode to anode voltage V R 600 V
Continuous forward current I F T = 25 °C C 75 A
T = 100 °C C 40
Single pulse forward current I FSM TBD
Maximum repetitive forward current I FRM 180
RMS isolation voltage, any terminal to case V ISOL t = 1 minute 2500 V
Maximum power dissipation P D T = 25 °C C 180 W
T = 100 °C C 71
Operating junction and storage temperature range T, T J Stg - 55 to 150 °C
ELECTRICAL SPECIFICATIONS PER LEG (T = 25 °C unless otherwise specified) J
PARAMETER SYMBOL TEST CONDITIONS MIN. TYP. MAX. UNITS
Cathode to anode breakdown voltage V BR I = 100 µA R 600 - - V
Maximum forward voltage V FM I = 60 A F See fig. 1 - 1.5 1.7
I = 120 A F - 1.9 2.1
I = 60 A, T = 125 °C F J - 1.4 1.6
Maximum reverse leakage current I RM V = V rated R R See fig. 2 - 2.5 20 µA
T = 125 °C, V = 0.8 x V rated J R R - 130 2000
Junction capacitance C T V = 200 V R See fig. 3 - 120 170 pF

Page 2

Diode, 60 A

DYNAMIC RECOVERY CHARACTERISTICS PER LEG (T = 25 °C unless otherwise specified) J
PARAMETER SYMBOL TEST CONDITIONS MIN. TYP. MAX. UNITS
Reverse recovery time See fig. 5, 6 and 16 t rr I = 1.0 A, dI /dt = 200 A/µs, V = 30 V F F R - 34 - ns
t rr1 T = 25 °C J I = 60 A F dI /dt = 200 A/µs F V = 200 V R - 65 98
t rr2 T = 125 °C J - 130 200
Peak recovery current See fig. 7 and 8 I RRM1 T = 25 °C J - 7.0 13 A
I RRM2 T = 125 °C J - 13 23
Reverse recovery charge See fig. 9 and 10 Q rr1 T = 25 °C J - 270 410 nC
Q rr2 T = 125 °C J - 490 740
Peak rate of recovery current during t b See fig. 11 and 12 dI /dt1 (rec)M T = 25 °C J - 350 - A/µs
dI /dt2 (rec)M T = 125 °C J - 270 -
THERMAL - MECHANICAL SPECIFICATIONS
PARAMETER SYMBOL MIN. TYP. MAX. UNITS
Junction to case, single leg conducting R thJC - - 0.70 °C/W K/W
Junction to case, both legs conducting - - 0.35
Case to sink, flat, greased surface R thCS - 0.05 -
Weight - 30 - g
Mounting torque - 1.3 - Nm

Page 3

Diode, 60 A

PDF page 3 diagram

Fig. 1 - Maximum Forward Voltage Drop vs. Instantaneous Forward Current (Per Leg)

PDF page 3 diagram

Fig. 2 - Typical Reverse Current vs. Reverse Voltage (Per Leg)

PDF page 3 diagram

Fig. 3 - Typical Junction Capacitance vs. Reverse Voltage (Per Leg)

PDF page 3 diagram

Fig. 4 - Maximum Thermal Impedance ZthJC Characteristics (Per Leg)

Page 4

Diode, 60 A

PDF page 4 diagram

Fig. 5 - Typical Reverse Recovery Time vs. dIF/dt (Per Leg)

PDF page 4 diagram

Fig. 6 - Typical Recovery Current vs. dIF/dt (Per Leg)

PDF page 4 diagram

Fig. 7- Typical Stored Charge vs. dIF/dt (Per Leg)

PDF page 4 diagram

Fig. 8 - Typical dI(rec)M/dt vs. dIF/dt (Per Leg)

Page 5

Diode, 60 A

PDF page 5 diagram

Fig. 9 - Reverse Recovery Parameter Test Circuit

PDF page 5 diagram

Fig. 10 - Reverse Recovery Waveform and Definitions

PDF page 5 diagram

Fig. 11 - Avalanche Test Circuit and Waveforms

Page 6

Diode, 60 A

ORDERING INFORMATION TABLE

PDF page 6 diagram
HF A 120 FA 60 P
1 2 3 4 5 6
PDF page 6 diagram
LINKS TO RELATED DOCUMENTS
Dimensions http://www.vishay.com/doc?95036
Packaging information http://www.vishay.com/doc?95037

Page 7

Legal Disclaimer Notice

Vishay

Disclaimer

All product specifications and data are subject to change without notice.

Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained herein or in any other disclosure relating to any product.

Vishay disclaims any and all liability arising out of the use or application of any product described herein or of any information provided herein to the maximum extent permitted by law. The product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase, including but not limited to the warranty expressed therein, which apply to these products.

No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay.

The products shown herein are not designed for use in medical, life-saving, or life-sustaining applications unless otherwise expressly indicated. Customers using or selling Vishay products not expressly indicated for use in such applications do so entirely at their own risk and agree to fully indemnify Vishay for any damages arising or resulting from such use or sale. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications.

Product names and markings noted herein may be trademarks of their respective owners.

Document Number: 91000 Revision: 18-Jul-08