HFA08SD60S-M3 VISHAY

Document overview

  • PDF pages: 8

Technical content

Page 1

FEATURES

PDF page 1 diagram

2, 4

  • Ultrafast recovery time
  • Ultrasoft recovery
  • Very low IRRM
  • Very low Qrr
  • Guaranteed avalanche

1 3

  • Specified at operating conditions

N/C Anode

  • Compliant to RoHS Directive 2002/95/EC
  • Halogen-free according to IEC 61249-2-21 definition
  • Meets MSL level 1, per J-STD-020, LF maximum peak of 260 °C
PRODUCT SUMMARY
Package D-PAK (TO-252AA)
I F(AV) 8 A
V R 600 V
V at I F F 1.7 V
t typ. rr 18 ns
T max. J 150 °C
Diode variation Single die

BENEFITS

  • Reduced RFI and EMI
  • Reduced power loss in diode and switching transistor
  • Higher frequency operation
  • Reduced snubbing
  • Reduced parts count

DESCRIPTION

These diodes are optimized to reduce losses and EMI/RFI in high frequency power conditioning systems. The softness of the recovery eliminates the need for a snubber in most applications. These devices are ideally suited for freewheeling, flyback, power converters, motor drives, and other applications where high speed and reduced switching losses are design requirements.

ABSOLUTE MAXIMUM RATINGS
PARAMETER SYMBOL TEST CONDITIONS VALUES UNITS
Cathode to anode voltage V RRM 600 V
Maximum continuous forward current I F T = 100 °C C 8 A
Single pulse forward current I FSM 60
Peak repetitive forward current I FRM 24
Maximum power dissipation P D T = 100 °C C 14 W
Operating junction and storage temperature range T , T J Stg - 55 to + 150 °C
ELECTRICAL SPECIFICATIONS (T = 25 °C unless otherwise specified) J
PARAMETER SYMBOL TEST CONDITIONS MIN. TYP. MAX. UNITS
Breakdown voltage, blocking voltage V , BR V R I = 100 μA R 600 - - V
Forward voltage V F I = 8 A F See fig. 1 - 1.4 1.7
I = 16 A F - 1.7 2.1
I = 8 A, T = 125 °C F J - 1.4 1.7
Maximum reverse leakage current I R V = V rated R R - 0.3 5.0 μA
T = 125 °C, V = 0.8 x V rated J R R - 100 500
Junction capacitance C T V = 200 V R See fig. 3 - 10 25 pF
Series inductance L S Measured lead to lead 5 mm from package body - 8.0 - nH

Page 2

DYNAMIC RECOVERY CHARACTERISTICS (T = 25 °C unless otherwise specified) J
PARAMETER SYMBOL TEST CONDITIONS MIN. TYP. MAX. UNITS
Reverse recovery time t rr I = 1.0 A, dI /dt = 200 A/μs, V = 30 V F F R - 18 - ns
T = 25 °C J I = 8 A F dI /dt = 200 A/μs F V = 200 V R - 37 55
T = 125 °C J - 55 90
Peak recovery current I RRM T = 25 °C J - 3.5 5.0 A
T = 125 °C J - 4.5 8.0
Reverse recovery charge Q rr T = 25 °C J - 65 138 nC
T = 125 °C J - 124 360
Rate of fall of recovery current dI /dt (rec)M T = 25 °C J - 240 - A/μs
T = 125 °C J - 210 -
THERMAL - MECHANICAL SPECIFICATIONS
PARAMETER SYMBOL TEST CONDITIONS MIN. TYP. MAX. UNITS
Maximum junction and storage temperature range T , T J Stg - 55 - 150 °C
Thermal resistance, junction to case R thJC - - 3.5 °C/W
Thermal resistance, junction to ambient R thJA Typical socket mount - - 80
Weight - 2.0 - g
- 0.07 - oz.
Marking device Case style D-PAK HFA08SD60S

Page 3

PDF page 3 diagram
PDF page 3 diagram

Fig. 1 - Typical Forward Voltage Drop Characteristics

Fig. 2 - Typical Values of Reverse Current vs.

Reverse Voltage

PDF page 3 diagram

Fig. 3 - Typical Junction Capacitance vs. Reverse Voltage

PDF page 3 diagram

Fig. 4 - Maximum Thermal Impedance ZthJC Characteristics

Page 4

PDF page 4 diagram

Fig. 5 - Typical Reverse Recovery Time vs. dIF/dt

PDF page 4 diagram

Fig. 6 - Typical Recovery Current vs. dIF/dt

PDF page 4 diagram

Fig. 7 - Typical Stored Charge vs. dIF/dt

PDF page 4 diagram

Fig. 8 - Typical dI(rec)M/dt vs. dIF/dt

Page 5

PDF page 5 diagram

Fig. 9 - Reverse Recovery Parameter Test Circuit

PDF page 5 diagram

Fig. 10 - Reverse Recovery Waveform and Definitions

Page 6

ORDERING INFORMATION TABLE

PDF page 6 diagram
VS- HF A 08 SD 60 S TR -M3
1 2 3 4 5 6 7 8 9
PDF page 6 diagram
ORDERING INFORMATION (Example)
PREFERRED P/N QUANTITY PER T/R MINIMUM ORDER QUANTITY PACKAGING DESCRIPTION
VS-HFA08SD60S-M3 75 3000 Antistatic plastic tube
VS-HFA08SD60STR-M3 2000 2000 13" diameter reel
VS-HFA08SD60SL-M3 3000 3000 13" diameter reel
VS-HFA08SD60SR-M3 3000 3000 13" diameter reel
LINKS TO RELATED DOCUMENTS
Dimensions www.vishay.com/doc?95016
Part marking information www.vishay.com/doc?95176
Packaging information www.vishay.com/doc?95033

Page 7

Outline Dimensions

Vishay High Power Products

D-PAK (TO-252AA)

PDF page 7 diagram

Notes (1) Dimensioning and tolerancing as per ASME Y14.5M-1994 (2) Lead dimension uncontrolled in L5 (3) Dimension D1, E1, L3 and b3 establish a minimum mounting surface for thermal pad (4) Section C - C dimension apply to the flat section of the lead between 0.13 and 0.25 mm (0.005 and 0.10") from the lead tip (5) Dimension D, and E do not include mold flash. Mold flash shall not exceed 0.127 mm (0.005") per side. These dimensions are measured at the outermost extremes of the plastic body (6) Dimension b1 and c1 applied to base metal only (7) Datum A and B to be determined at datum plane H (8) Outline conforms to JEDEC outline TO-252AA

For technical questions concerning discrete products, contact: diodes-tech@vishay.com

Document Number: 95016

For technical questions concerning module products, contact: ind-modules@vishay.com

Revision: 04-Nov-08

Page 8

Legal Disclaimer Notice

Vishay

Disclaimer

ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.

Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product.

Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability.

Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All operating parameters, including typical parameters, must be validated for each customer application by the customer’s

technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase, including but not limited to the warranty expressed therein.

Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining applications or for any other application in which the failure of the Vishay product could result in personal injury or death. Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk and agree to fully indemnify and hold Vishay and its distributors harmless from and against any and all claims, liabilities, expenses and damages arising or resulting in connection with such use or sale, including attorneys fees, even if such claim alleges that Vishay or its distributor was negligent regarding the design or manufacture of the part. Please contact authorized Vishay personnel to

obtain written terms and conditions regarding products designed for such applications.

No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.

Document Number: 91000 Revision: 11-Mar-11