HFA08PB60PBF VISHAY

Document overview

  • PDF pages: 7

Technical content

Page 1

FEATURES

PDF page 1 diagram
  • Ultrafast recovery
  • Ultrasoft recovery

Available

RoHS\*

  • Very low IRRM

COMPLIANT

  • Very low Qrr
  • Specified at operating conditions
  • Lead (Pb)-free
  • Designed and qualified for industrial level

BENEFITS

  • Reduced RFI and EMI
  • Reduced power loss in diode and switching transistor
  • Higher frequency operation
  • Reduced snubbing
  • Reduced parts count

DESCRIPTION

HFA08PB60 is a state of the art ultrafast recovery diode. Employing the latest in epitaxial construction and advanced processing techniques it features a superb combination of characteristics which result in performance which is unsurpassed by any rectifier previously available. With basic ratings of 600 V and 8 A continuous current, the HFA08PB60

PRODUCT SUMMARY
V R 600 V
V at 8 A at 25 °C F 1.7 V
I F(AV) 8 A
t (typical) rr 18 ns
T (maximum) J 150 °C
Q (typical) rr 65 nC
dI /dt (typical) at 125 °C (rec)M 210 A/µs
I (typical) RRM 3.5 A

is especially well suited for use as the companion diode for IGBTs and MOSFETs. In addition to ultrafast recovery time, the HEXFRED® product line features extremely low values of peak recovery current (IRRM) and does not exhibit any tendency to “snap-off” during the tb portion of recovery. The HEXFRED features combine to offer designers a rectifier with lower noise and significantly lower switching losses in both the diode and the switching transistor. These HEXFRED advantages can help to significantly reduce snubbing, component count and heatsink sizes. The HEXFRED HFA08PB60 is ideally suited for applications in power supplies and power conversion systems (such as

inverters), motor drives, and many other similar applications where high speed, high efficiency is needed.

ABSOLUTE MAXIMUM RATINGS
PARAMETER SYMBOL TEST CONDITIONS VALUES UNITS
Cathode to anode voltage V R 600 V
Maximum continuous forward current I F T = 100 °C C 8 A
Single pulse forward current I FSM 60
Maximum repetitive forward current I FRM 24
Maximum power dissipation P D T = 25 °C C 36 W
T = 100 °C C 14
Operating junction and storage temperature range T, T J Stg - 55 to + 150 °C

\* Pb containing terminations are not RoHS compliant, exemptions may apply

Page 2

ELECTRICAL SPECIFICATIONS (T = 25 °C unless otherwise specified) J
PARAMETER SYMBOL TEST CONDITIONS MIN. TYP. MAX. UNITS
Cathode to anode breakdown voltage V BR I = 100 µA R 600 - - V
Maximum forward voltage V FM I = 8.0 A F See fig. 1 - 1.4 1.7
I = 16 A F - 1.7 2.1
I = 8.0 A, T = 125 °C F J - 1.4 1.7
Maximum reverse leakage current I RM V = V rated R R See fig. 2 - 0.3 5.0 µA
T = 125 °C, V = 0.8 x V rated J R R - 100 500
Junction capacitance C T V = 200 V R See fig. 3 - 10 25 pF
Series inductance L S Measured lead to lead 5 mm from package body - 8.0 - nH
DYNAMIC RECOVERY CHARACTERISTICS (T = 25 °C unless otherwise specified) J
PARAMETER SYMBOL TEST CONDITIONS MIN. TYP. MAX. UNITS
Reverse recovery time See fig. 5, 10 t rr I = 1.0 A, dI /dt = 200 A/µs, V = 30 V F F R - 18 - ns
t rr1 T = 25 °C J I = 8.0 A F dI /dt = 200 A/µs F V = 200 V R - 37 55
t rr2 T = 125 °C J - 55 90
Peak recovery current See fig. 6 I RRM1 T = 25 °C J - 3.5 5.0 A
I RRM2 T = 125 °C J - 4.5 8.0
Reverse recovery charge See fig. 7 Q rr1 T = 25 °C J - 65 138 nC
Q rr2 T = 125 °C J - 124 360
Peak rate of recovery current during t b See fig. 8 dI /dt1 (rec)M T = 25 °C J - 240 - A/µs
dI /dt2 (rec)M T = 125 °C J - 210 -
THERMAL - MECHANICAL SPECIFICATIONS
PARAMETER SYMBOL TEST CONDITIONS MIN. TYP. MAX. UNITS
Lead temperature T lead 0.063" from case (1.6 mm) for 10 s - - 300 °C
Thermal resistance, junction to case RθJC - - 3.5 K/W
Thermal resistance, junction to ambient RθJA Typical socket mount - - 40
Thermal resistance, case to heatsink RθCS Mounting surface, flat, smooth and greased - 0.25 -
Weight - 6.0 - g
- 0.21 - oz.
Mounting torque 6.0 (5.0) - 12 (10) kgf · cm (lbf · in)
Marking device Case style TO-247AC modified (JEDEC) HFA08PB60

Page 3

PDF page 3 diagram

Fig. 1 - Maximum Forward Voltage Drop vs. Instantaneous Forward Current

PDF page 3 diagram

Fig. 2 - Typical Reverse Current vs. Reverse Voltage

PDF page 3 diagram

Fig. 3 - Typical Junction Capacitance vs. Reverse Voltage

PDF page 3 diagram

Fig. 4 - Maximum Thermal Impedance ZthJC Characteristics

Page 4

PDF page 4 diagram

Fig. 5 - Typical Reverse Recovery Time vs. dIF/dt

(Per Leg)

PDF page 4 diagram

Fig. 6 - Typical Recovery Current vs. dIF/dt

(Per Leg)

PDF page 4 diagram

Fig. 7 - Typical Stored Charge vs. dIF/dt

(Per Leg)

PDF page 4 diagram

Fig. 8 - Typical dI(rec)M/dt vs. dIF/dt (Per Leg)

Page 5

PDF page 5 diagram

Fig. 9 - Reverse Recovery Parameter Test Circuit

PDF page 5 diagram

Fig. 10 - Reverse Recovery Waveform and Definitions

Page 6

ORDERING INFORMATION TABLE

PDF page 6 diagram
HF A 08 PB 60 PbF
1 2 3 4 5 6
PDF page 6 diagram
LINKS TO RELATED DOCUMENTS
Dimensions http://www.vishay.com/doc?95253
Part marking information http://www.vishay.com/doc?95255

Page 7

Legal Disclaimer Notice

Vishay

Disclaimer

All product specifications and data are subject to change without notice.

Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained herein or in any other disclosure relating to any product.

Vishay disclaims any and all liability arising out of the use or application of any product described herein or of any information provided herein to the maximum extent permitted by law. The product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase, including but not limited to the warranty expressed therein, which apply to these products.

No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay.

The products shown herein are not designed for use in medical, life-saving, or life-sustaining applications unless otherwise expressly indicated. Customers using or selling Vishay products not expressly indicated for use in such applications do so entirely at their own risk and agree to fully indemnify Vishay for any damages arising or resulting from such use or sale. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications.

Product names and markings noted herein may be trademarks of their respective owners.

Document Number: 91000 Revision: 18-Jul-08