HEF4521B_V01 NEXPERIA

Document overview

  • PDF pages: 15

Technical content

Page 1

1. General description

The HEF4521B consists of a chain of 24 toggle flip-flops with an overriding asynchronous master reset input (MR), and an input circuit that allows three modes of operation. The single inverting stage (A2 to Y2) functions as: a crystal oscillator, an input buffer for an external oscillator or in combination with A1 as an RC oscillator. The crystal oscillator operates in Low-power mode when pins VSS1 and VDD1 are supplied via external resistors. Each flip-flop divides the frequency of the previous flip-flop by two, consequently the HEF4521B counts up to 224 = 16777216. The counting advances on the HIGH-to-LOW transition of the clock (A2). The outputs from each of the last seven stages (218 to 224) are available for additional

flexibility.

It operates over a recommended VDD power supply range of 3 V to 15 V referenced to VSS (usually ground). Unused inputs must be connected to VDD, VSS, or another input.

2. Features and benefits

  • Wide supply voltage range from 3.0 V to 15.0 V
  • CMOS low power dissipation
  • High noise immunity
  • Low power crystal oscillator operation
  • Fully static operation
  • 5 V, 10 V, and 15 V parametric ratings
  • Standardized symmetrical output characteristics
  • Complies with JEDEC standard JESD 13-B
  • ESD protection:
  • HBM JESD22-A114F exceeds 2000 V
  • MM JESD22-A115-A exceeds 200 V
  • Specified from -40 °C to +85 °C

3. Ordering information

Table 1. Ordering information

Type number Package
Temperature range Name Description Version
HEF4521BT -40 °C to +85 °C SO16 plastic small outline package; 16 leads; body width 3.9 mm SOT109-1

Page 2

4. Functional diagram

PDF page 2 diagram

2 / 15

Page 3

PDF page 3 diagram

3 / 15

Page 4

5. Pinning information

5.1. Pinning

PDF page 4 diagram

5.2. Pin description

Table 2. Pin description

Symbol Pin Description
MR 2 master reset input
V SS1 3 ground supply voltage 1
V DD1 5 supply voltage 1
Y1, Y2 7, 4 external oscillator connection
V SS 8 ground supply voltage
A1, A2 9, 6 external oscillator connection
Q18, Q19, Q20, Q21, Q22, Q23, Q24 10, 11, 12, 13, 14, 15, 1 output
V DD 16 supply voltage

6. Count capacity

Table 3. Count capacity

Output Count capacity
Q18 218 = 262144
Q19 219 = 524288
Q20 220 = 1048576
Q21 221 = 2097152
Q22 222 = 4194304
Q23 223 = 8388608
Q24 224 = 16777216

4 / 15

Page 5

7. Functional test

A test function has been included to reduce the test time required to test all 24 counter stages. This test function divides the counter into three 8-stage sections by connecting VSS1 to VDD and VDD1 to VSS. 255 counts are loaded into each of the 8-stage sections in parallel via A2 (connected to Y2). All flip-flops are now at a HIGH level. The counter is now returned to the normal 24-stage in series configuration by connecting VSS1 to VSS and VDD1 to VDD. Entering one more pulse into input A2 causes the counter to ripple from an all HIGH state to an all LOW state.

Table 4. Functional test sequence H = HIGH voltage level; L = LOW voltage level; ↓ = HIGH to LOW transition.

Inputs Control terminals Outputs Remarks
MR A2 Y2 V SS1 V DD1 Q18 to Q24
H L L V DD V SS L Counter is in three 8-stage sections in parallel mode; A2 and Y2 are interconnected (Y2 is now input); counter is reset by MR.
L [1] [1] V DD V SS H
L L L V SS V SS H V is connected to V . SS1 SS
L H L V SS V SS H The input A2 is made HIGH.
L H L V SS V DD H V is connected to V ; Y2 is now made floating and DD1 DD becomes an output; the device is now in the 224 mode.
L ↓ V SS V DD L Counter ripples from an all HIGH state to an all LOW state.

[1] 255 pulses are clocked into A2, Y2. The counter advances on the LOW to HIGH transition.

8. Limiting values

Table 5. Limiting values In accordance with the Absolute Maximum Rating System (IEC 60134).

Symbol Parameter Conditions Min Max Unit
V DD supply voltage -0.5 +18 V
I IK input clamping current V < -0.5 V or V > V + 0.5 V I I DD - ±10 mA
V I input voltage -0.5 V + 0.5 DD V
I OK output clamping current V < -0.5 V or V > V + 0.5 V O O DD - ±10 mA
I I/O input/output current - ±10 mA
I DD supply current to any supply terminal - ±100 mA
T stg storage temperature -65 +150 °C
T amb ambient temperature -40 +85 °C
P tot total power dissipation T -40 °C to +85 °C amb - 500 mW
P power dissipation per output - 100 mW

5 / 15

Page 6

9. Recommended operating conditions

Table 6. Recommended operating conditions

Symbol Parameter Conditions Min Typ Max Unit
V DD supply voltage 3 - 15 V
V I input voltage 0 - V DD V
T amb ambient temperature in free air -40 - +85 °C
Δt/ΔV input transition rise and fall rate V = 5 V DD - - 3.75 μs/V
V = 10 V DD - - 0.5 μs/V
V = 15 V DD - - 0.08 μs/V

10. Static characteristics

Table 7. Static characteristics VSS = 0 V; VI = VSS or VDD unless otherwise specified.

Symbol Parameter Conditions V DD T = -40 °C amb T = +25 °C amb T = +85 °C amb Unit
Min Max Min Max Min Max
V IH HIGH-level input voltage |I | < 1 μA O 5 V 3.5 - 3.5 - 3.5 - V
10 V 7.0 - 7.0 - 7.0 - V
15 V 11.0 - 11.0 - 11.0 - V
V IL LOW-level input voltage |I | < 1 μA O 5 V - 1.5 - 1.5 - 1.5 V
10 V - 3.0 - 3.0 - 3.0 V
15 V - 4.0 - 4.0 - 4.0 V
V OH HIGH-level output voltage |I | < 1 μA O 5 V 4.95 - 4.95 - 4.95 - V
10 V 9.95 - 9.95 - 9.95 - V
15 V 14.95 - 14.95 - 14.95 - V
V OL LOW-level output voltage |I | < 1 μA O 5 V - 0.05 - 0.05 - 0.05 V
10 V - 0.05 - 0.05 - 0.05 V
15 V - 0.05 - 0.05 - 0.05 V
I OH HIGH-level output current V = 2.5 V O 5 V - -1.7 - -1.4 - -1.1 mA
V = 4.6 V O 5 V - -0.52 - -0.44 - -0.36 mA
V = 9.5 V O 10 V - -1.3 - -1.1 - -0.9 mA
V = 13.5 V O 15 V - -3.6 - -3.0 - -2.4 mA
I OL LOW-level output current V = 0.4 V O 5 V 0.52 - 0.44 - 0.36 - mA
V = 0.5 V O 10 V 1.3 - 1.1 - 0.9 - mA
V = 1.5 V O 15 V 3.6 - 3.0 - 2.4 - mA
I I input leakage current 15 V - ±0.3 - ±0.3 - ±1.0 μA
I DD supply current I = 0 A O 5 V - 20 - 20 - 150 μA
10 V - 40 - 40 - 300 μA
15 V - 80 - 80 - 600 μA
C I input capacitance - - - - 7.5 - - pF

6 / 15

Page 7

11. Dynamic characteristics

Table 8. Dynamic characteristics VSS = 0 V; Tamb = 25 °C unless otherwise specified; for test circuit see Fig. 6.

Symbol Parameter Conditions V DD Extrapolation formula[1] Min Typ Max Unit
t PHL HIGH to LOW propagation delay A2 to Q18; see Fig. 5 5 V 923 ns + (0.55 ns/pF)C L - 950 1900 ns
10 V 339 ns + (0.23 ns/pF)C L - 350 700 ns
15 V 212 ns + (0.16 ns/pF)C L - 220 440 ns
Qn to Qn + 1; see Fig. 5 5 V 13 ns + (0.55 ns/pF)C L - 40 80 ns
10 V 4 ns + (0.23 ns/pF)C L - 15 30 ns
15 V 2 ns + (0.16 ns/pF)C L - 10 20 ns
MR to Qn 5 V 93 ns + (0.55 ns/pF)C L - 120 240 ns
10 V 44 ns + (0.23 ns/pF)C L - 55 110 ns
15 V 32 ns + (0.16 ns/pF)C L - 40 80 ns
A1 to Y1; see Fig. 5 5 V 63 ns + (0.55 ns/pF)C L - 90 180 ns
10 V 24 ns + (0.23 ns/pF)C L - 35 70 ns
15 V 17 ns + (0.16 ns/pF)C L - 25 50 ns
t PLH LOW to HIGH propagation delay A2 to Q18; see Fig. 5 5 V 923 ns + (0.55 ns/pF)C L - 950 1900 ns
10 V 339 ns + (0.23 ns/pF)C L - 350 700 ns
15 V 212 ns + (0.16 ns/pF)C L - 220 440 ns
Qn to Qn + 1; see Fig. 5 5 V 13 ns + (0.55 ns/pF)C L - 40 80 ns
10 V 4 ns + (0.23 ns/pF)C L - 15 30 ns
15 V 2 ns + (0.16 ns/pF)C L - 10 20 ns
A1 to Y1; see Fig. 5 5 V 33 ns + (0.55 ns/pF)C L - 60 120 ns
10 V 19 ns + (0.23 ns/pF)C L - 30 60 ns
15 V 12 ns + (0.16 ns/pF)C L - 20 40 ns
t t transition time Qn; see Fig. 5 5 V 10 ns + (1.00 ns/pF)C L - 60 120 ns
10 V 9 ns + (0.42 ns/pF)C L - 30 60 ns
15 V 6 ns + (0.28 ns/pF)C L - 20 40 ns
t W pulse width A2 HIGH; minimum width; see Fig. 5 5 V 80 40 - ns
10 V 40 20 - ns
15 V 30 15 - ns
MR HIGH; minimum width; see Fig. 5 5 V 70 35 - ns
10 V 40 20 - ns
15 V 30 15 - ns
t rec recovery time MR; see Fig. 5 5 V +20 -10 - ns
10 V +15 -5 - ns
15 V 15 0 - ns
f max maximum frequency A1; see Fig. 5 5 V 6 12 - MHz
10 V 12 25 - MHz
15 V 17 35 - MHz

[1] The typical values of the propagation delay and transition times are calculated from the extrapolation formulas shown (CL in pF).

7 / 15

Page 8

Table 9. Dynamic power dissipation PD PD can be calculated from the formulas shown. VSS = 0 V; tr = tf ≤ 20 ns; Tamb = 25 °C.

Symbol Parameter V DD Typical formula for P (μW) D where:
P D dynamic power dissipation 5 V P = 1200 × f + Σ(f × C ) × V 2 D i o L DD f = input frequency in MHz, i f = output frequency in MHz, o C = output load capacitance in pF, L V = supply voltage in V, DD Σ(C × f ) = sum of the outputs. L o
10 V P = 5100 × f + Σ(f × C ) × V 2 D i o L DD
15 V P = 13050 × f + Σ(f × C ) × V 2 D i o L DD

11.1. Waveforms and test circuit

PDF page 8 diagram

Table 10. Measurement points

Supply voltage Input Output
V DD V M V M
5 V to 15 V 0.5V DD 0.5V DD

8 / 15

Page 9

PDF page 9 diagram

Table 11. Test data

Supply Input Load
V DD V I t, t r f C L
5 V to 15 V V or V SS DD ≤ 20 ns 50 pF

12. Application information

PDF page 9 diagram

9 / 15

Page 10

Table 12. Typical characteristics for crystal oscillator

Parameter 500 kHz circuit 50 kHz circuit Unit
Crystal characteristics
Resonance frequency 500 50 kHz
Crystal cut S N -
Equivalent resistance; R S 1 6.2 kΩ
External resistor/capacitor values
R o 47 750 kΩ
C T 82 82 pF
C S 20 20 pF
PDF page 10 diagram

10 / 15

Page 11

PDF page 11 diagram
001aae716 75 gain (VO/VI) 50 typ 25 0 0 5 10 15 VDD (V) For test setup, see Fig. 14. Fig. 12. Voltage gain V /V as a function of supply O I voltage 001aae717 20 IDD (mA) 15 typ 10 5 0 0 5 10 15 VDD (V) For test setup, see Fig. 14. Fig. 13. Supply current as a function of supply voltage
330 kΩ A2 Y2 001aae718 Fig. 14. Test setup for measuring the voltage gain and supply current graphs

11 / 15

Page 12

13. Package outline

SO16: plastic small outline package; 16 leads; body width 3.9 mm

SOT109-1

PDF page 12 diagram
PDF page 12 diagram

Note 1. Plastic or metal protrusions of 0.15 mm (0.006 inch) maximum per side are not included.

PDF page 12 diagram

Fig. 15. Package outline SOT109-1 (SO16)

12 / 15

Page 13

14. Abbreviations

Table 13. Abbreviations

Acronym Description
CMOS Complementary Metal Oxide Semiconductor
DUT Device Under Test
ESD ElectroStatic Discharge
HBM Human Body Model
MM Machine Model

15. Revision history

Table 14. Revision history

Document ID Release date Data sheet status Change notice Supersedes
HEF4521B v.8 20211203 Product data sheet - HEF4521B v.7
Modifications: • The format of this data sheet has been redesigned to comply with the identity guidelines of Nexperia. • Legal texts have been adapted to the new company name where appropriate. • Section 2 updated. • Section 14 added.
HEF4521B v.7 20160330 Product data sheet - HEF4521B v.6
Modifications: • Type number HEF4521BP (SOT38-4) removed.
HEF4521B v.6 20111121 Product data sheet - HEF4521B v.5
Modifications: • Section Applications removed • Table 4: added references to Table note [1] and [2] • Table 7: I minimum values changed to maximum OH • Fig. 11: space between "2" and "s" removed in figure notes [1] and [3]
HEF4521B v.5 20091105 Product data sheet - HEF4521B v.4
HEF4521B v.4 20090421 Product data sheet - HEF4521B_CNV v.3
HEF4521B_CNV v.3 19950101 Product specification - HEF4521B_CNV v.2
HEF4521B_CNV v.2 19950101 Product specification - -

13 / 15

Page 14

16. Legal information

Data sheet status

Document status [1][2] Product status [3] Definition
Objective [short] data sheet Development This document contains data from the objective specification for product development.
Preliminary [short] data sheet Qualification This document contains data from the preliminary specification.
Product [short] data sheet Production This document contains the product specification.

[1] Please consult the most recently issued document before initiating or completing a design. [2] The term 'short data sheet' is explained in section "Definitions". [3] The product status of device(s) described in this document may have changed since this document was published and may differ in case of multiple devices. The latest product status information is available on the internet at https://www.nexperia.com.

Definitions

Draft — The document is a draft version only. The content is still under internal review and subject to formal approval, which may result in modifications or additions. Nexperia does not give any representations or warranties as to the accuracy or completeness of information included herein and shall have no liability for the consequences of use of such information.

Short data sheet — A short data sheet is an extract from a full data sheet with the same product type number(s) and title. A short data sheet is intended for quick reference only and should not be relied upon to contain detailed and full information. For detailed and full information see the relevant full data sheet, which is available on request via the local Nexperia sales office. In case of any inconsistency or conflict with the short data sheet, the full data sheet shall prevail.

Product specification — The information and data provided in a Product data sheet shall define the specification of the product as agreed between Nexperia and its customer, unless Nexperia and customer have explicitly agreed otherwise in writing. In no event however, shall an agreement be valid in which the Nexperia product is deemed to offer functions and qualities beyond those described in the Product data sheet.

Disclaimers

Limited warranty and liability — Information in this document is believed to be accurate and reliable. However, Nexperia does not give any representations or warranties, expressed or implied, as to the accuracy or completeness of such information and shall have no liability for the consequences of use of such information. Nexperia takes no responsibility for the content in this document if provided by an information source outside of Nexperia.

In no event shall Nexperia be liable for any indirect, incidental, punitive, special or consequential damages (including - without limitation - lost profits, lost savings, business interruption, costs related to the removal or replacement of any products or rework charges) whether or not such damages are based on tort (including negligence), warranty, breach of contract or any other legal theory.

Notwithstanding any damages that customer might incur for any reason whatsoever, Nexperia’s aggregate and cumulative liability towards customer for the products described herein shall be limited in accordance with the Terms and conditions of commercial sale of Nexperia.

Right to make changes — Nexperia reserves the right to make changes to information published in this document, including without limitation specifications and product descriptions, at any time and without notice. This document supersedes and replaces all information supplied prior to the publication hereof.

Suitability for use — Nexperia products are not designed, authorized or warranted to be suitable for use in life support, life-critical or safety-critical systems or equipment, nor in applications where failure or malfunction of an Nexperia product can reasonably be expected to result in personal

injury, death or severe property or environmental damage. Nexperia and its suppliers accept no liability for inclusion and/or use of Nexperia products in such equipment or applications and therefore such inclusion and/or use is at the customer’s own risk.

Quick reference data — The Quick reference data is an extract of the product data given in the Limiting values and Characteristics sections of this document, and as such is not complete, exhaustive or legally binding.

Applications — Applications that are described herein for any of these products are for illustrative purposes only. Nexperia makes no representation or warranty that such applications will be suitable for the specified use without further testing or modification.

Customers are responsible for the design and operation of their applications and products using Nexperia products, and Nexperia accepts no liability for any assistance with applications or customer product design. It is customer’s sole responsibility to determine whether the Nexperia product is suitable and fit for the customer’s applications and products planned, as well as for the planned application and use of customer’s third party customer(s). Customers should provide appropriate design and operating safeguards to minimize the risks associated with their applications and products.

Nexperia does not accept any liability related to any default, damage, costs or problem which is based on any weakness or default in the customer’s applications or products, or the application or use by customer’s third party customer(s). Customer is responsible for doing all necessary testing for the customer’s applications and products using Nexperia products in order to avoid a default of the applications and the products or of the application or use by customer’s third party customer(s). Nexperia does not accept any liability in this respect.

Limiting values — Stress above one or more limiting values (as defined in the Absolute Maximum Ratings System of IEC 60134) will cause permanent damage to the device. Limiting values are stress ratings only and (proper) operation of the device at these or any other conditions above those given in the Recommended operating conditions section (if present) or the Characteristics sections of this document is not warranted. Constant or repeated exposure to limiting values will permanently and irreversibly affect the quality and reliability of the device.

Terms and conditions of commercial sale — Nexperia products are sold subject to the general terms and conditions of commercial sale, as published at http://www.nexperia.com/profile/terms, unless otherwise agreed in a valid written individual agreement. In case an individual agreement is concluded only the terms and conditions of the respective agreement shall apply. Nexperia hereby expressly objects to applying the customer’s general terms and conditions with regard to the purchase of Nexperia products by customer.

No offer to sell or license — Nothing in this document may be interpreted or construed as an offer to sell products that is open for acceptance or the grant, conveyance or implication of any license under any copyrights, patents or other industrial or intellectual property rights.

Export control — This document as well as the item(s) described herein may be subject to export control regulations. Export might require a prior authorization from competent authorities.

Non-automotive qualified products — Unless this data sheet expressly states that this specific Nexperia product is automotive qualified, the product is not suitable for automotive use. It is neither qualified nor tested in accordance with automotive testing or application requirements. Nexperia accepts no liability for inclusion and/or use of non-automotive qualified products in automotive equipment or applications.

In the event that customer uses the product for design-in and use in automotive applications to automotive specifications and standards, customer (a) shall use the product without Nexperia’s warranty of the product for such automotive applications, use and specifications, and (b) whenever customer uses the product for automotive applications beyond Nexperia’s specifications such use shall be solely at customer’s own risk, and (c) customer fully indemnifies Nexperia for any liability, damages or failed product claims resulting from customer design and use of the product for automotive applications beyond Nexperia’s standard warranty and Nexperia’s product specifications.

Translations — A non-English (translated) version of a document is for reference only. The English version shall prevail in case of any discrepancy between the translated and English versions.

Trademarks

Notice: All referenced brands, product names, service names and trademarks are the property of their respective owners.

14 / 15

Page 15

Contents

  1. General description......................................................1 2. Features and benefits.................................................. 1 3. Ordering information....................................................1 4. Functional diagram.......................................................2 5. Pinning information......................................................4 5.1. Pinning.........................................................................4 5.2. Pin description.............................................................4 6. Count capacity..............................................................4 7. Functional test..............................................................5
  1. Limiting values............................................................. 5 9. Recommended operating conditions..........................6 10. Static characteristics..................................................6 11. Dynamic characteristics.............................................7 11.1. Waveforms and test circuit........................................ 8 12. Application information............................................. 9 13. Package outline........................................................ 12 14. Abbreviations............................................................13 15. Revision history........................................................13
  1. Legal information......................................................14

For more information, please visit: http://www.nexperia.com For sales office addresses, please send an email to: salesaddresses@nexperia.com Date of release: 3 December 2021

15 / 15