HEF4073B NEXPERIA
Document overview
- PDF pages: 11
Technical content
Page 1
1 General description
The HEF4073B is a triple 3-input AND gate. The outputs are fully buffered for highest noise immunity and pattern insensitivity to output impedance variations.
It operates over a recommended VDD power supply range of 3 V to 15 V referenced to VSS (usually ground). Unused inputs must be connected to VDD, VSS, or another input.
2 Features and benefits
- Fully static operation
- 5 V, 10 V, and 15 V parametric ratings
- Standardized symmetrical output characteristics
- Inputs and outputs are protected against electrostatic effects
- Specified from -40 °C to +85 °C
- Complies with JEDEC standard JESD 13-B
3 Ordering information
Table 1. Ordering information
| Type number | Package | |||
|---|---|---|---|---|
| Temperature range | Name | Description | Version | |
| HEF4073BT | -40 °C to +85 °C | SO14 | plastic small outline package; 14 leads; body width 3.9 mm | SOT108-1 |
4 Functional diagram

Page 2
5 Pinning information
5.1 Pinning

5.2 Pin description
Table 2. Pin description
| Symbol | Pin | Description |
|---|---|---|
| 1A, 2A, 3A | 3, 1, 11 | data input |
| 1B, 2B, 3B | 4, 2, 12 | data input |
| 1C, 2C, 3C | 5, 8, 13 | data input |
| 1Y, 2Y, 3Y | 6, 9, 10 | data output |
| V SS | 7 | ground (0 V) |
| V DD | 14 | supply voltage |
6 Functional description
Table 3. Function selection [1]
| Input | Output | ||
| nA | nB | nC | nY |
| L | X | X | L |
| X | L | X | L |
| X | X | L | L |
| H | H | H | H |
[1] H = HIGH voltage level; L = LOW voltage level; X = don’t care
2 / 11
Page 3
7 Limiting values
Table 4. Limiting values In accordance with the Absolute Maximum Rating System (IEC 60134). Voltages are referenced to VSS = 0 V (ground).
| Symbol | Parameter | Conditions | Min | Max | Unit |
|---|---|---|---|---|---|
| V DD | supply voltage | -0.5 | +18 | V | |
| I IK | input clamping current | V < -0.5 V or V > V + 0.5 V I I DD | - | ±10 | mA |
| V I | input voltage | -0.5 | V + 0.5 DD | V | |
| I OK | output clamping current | V < -0.5 V or V > V + 0.5 V O O DD | - | ±10 | mA |
| I I/O | input/output current | - | ±10 | mA | |
| I DD | supply current | - | 50 | mA | |
| T stg | storage temperature | -65 | +150 | °C | |
| T amb | ambient temperature | -40 | +85 | °C | |
| P tot | total power dissipation | T = -40 °C to + 85 °C [1] amb | - | 500 | mW |
| P | power dissipation | per output | - | 100 | mW |
[1] For SO14 packages: above Tamb = 70 °C, Ptot derates linearly with 8 mW/K.
8 Recommended operating conditions
Table 5. Recommended operating conditions
| Symbol | Parameter | Conditions | Min | Max | Unit |
|---|---|---|---|---|---|
| V DD | supply voltage | 3 | 15 | V | |
| V I | input voltage | 0 | V DD | V | |
| T amb | ambient temperature | in free air | -40 | +85 | °C |
| Δt/ΔV | input transition rise and fall rate | V = 5 V DD | - | 3.75 | ns/V |
| V = 10 V DD | - | 0.5 | ns/V | ||
| V = 15 V DD | - | 0.08 | ns/V |
3 / 11
Page 4
9 Static characteristics
Table 6. Static characteristics VSS = 0 V; VI = VSS or VDD; unless otherwise specified.
| Symbol | Parameter | Conditions | V DD | T = -40 °C amb | T = +25 °C amb | T = +85 °C amb | Unit | |||
|---|---|---|---|---|---|---|---|---|---|---|
| Min | Max | Min | Max | Min | Max | |||||
| V IH | HIGH-level input voltage | |I | < 1 μA O | 5 V | 3.5 | - | 3.5 | - | 3.5 | - | V |
| 10 V | 7.0 | - | 7.0 | - | 7.0 | - | V | |||
| 15 V | 11.0 | - | 11.0 | - | 11.0 | - | V | |||
| V IL | LOW-level input voltage | |I | < 1 μA O | 5 V | - | 1.5 | - | 1.5 | - | 1.5 | V |
| 10 V | - | 3.0 | - | 3.0 | - | 3.0 | V | |||
| 15 V | - | 4.0 | - | 4.0 | - | 4.0 | V | |||
| V OH | HIGH-level output voltage | |I | < 1 μA O | 5 V | 4.95 | - | 4.95 | - | 4.95 | - | V |
| 10 V | 9.95 | - | 9.95 | - | 9.95 | - | V | |||
| 15 V | 14.95 | - | 14.95 | - | 14.95 | - | V | |||
| V OL | LOW-level output voltage | |I | < 1 μA O | 5 V | - | 0.05 | - | 0.05 | - | 0.05 | V |
| 10 V | - | 0.05 | - | 0.05 | - | 0.05 | V | |||
| 15 V | - | 0.05 | - | 0.05 | - | 0.05 | V | |||
| I OH | HIGH-level output current | V = 2.5 V O | 5 V | - | -1.7 | - | -1.4 | - | -1.1 | mA |
| V = 4.6 V O | 5 V | - | -0.52 | - | -0.44 | - | -0.36 | mA | ||
| V = 9.5 V O | 10 V | - | -1.3 | - | -1.1 | - | -0.9 | mA | ||
| V = 13.5 V O | 15 V | - | -3.6 | - | -3.0 | - | -2.4 | mA | ||
| I OL | LOW-level output current | V = 0.4 V O | 5 V | 0.52 | - | 0.44 | - | 0.36 | - | mA |
| V = 0.5 V O | 10 V | 1.3 | - | 1.1 | - | 0.9 | - | mA | ||
| V = 1.5 V O | 15 V | 3.6 | - | 3.0 | - | 2.4 | - | mA | ||
| I I | input leakage current | 15 V | - | ±0.3 | - | ±0.3 | - | ±1.0 | μA | |
| I DD | supply current | all valid input combinations; I = 0 A O | 5 V | - | 1.0 | - | 1.0 | - | 7.5 | μA |
| 10 V | - | 2.0 | - | 2.0 | - | 15.0 | μA | |||
| 15 V | - | 4.0 | - | 4.0 | - | 30.0 | μA | |||
| C I | input capacitance | - | - | - | 7.5 | - | - | pF | ||
4 / 11
Page 5
10 Dynamic characteristics
Table 7. Dynamic characteristics VSS = 0 V; Tamb = 25 °C; for test circuit see Figure 5.
| Symbol | Parameter | Conditions | Extrapolation formula[1] | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|---|
| t PHL | HIGH to LOW propagation delay | nA, nB, nC to nY; see Figure 4 | |||||
| V = 5 V DD | 23 + 0.55 × C L | - | 55 | 110 | ns | ||
| V = 10 V DD | 14 + 0.23 × C L | - | 25 | 50 | ns | ||
| V = 15V DD | 12 + 0.16 × C L | - | 20 | 40 | ns | ||
| t PLH | LOW to HIGH propagation delay | nA, nB, nC to nY; see Figure 4 | |||||
| V = 5 V DD | 13 + 0.55 × C L | - | 45 | 90 | ns | ||
| V = 10 V DD | 9 + 0.23 × C L | - | 20 | 40 | ns | ||
| V = 15V DD | 7 + 0.16 × C L | - | 15 | 30 | ns | ||
| t t | output transition time | nY; see Figure 4 [2] | 10 + 1.0 × C L | - | 60 | 120 | ns |
| 9 + 0.42 × C L | - | 30 | 60 | ns | |||
| 6 + 0.28 × C L | - | 20 | 40 | ns |
[1] The typical value of the propagation delay and output transition time can be calculated with the extrapolation formula (CL in pF). [2] tt is the same as tTHL and tTLH.
Table 8. Dynamic power dissipation VSS = 0 V; Tamb = 25 °C.
| Symbol | Parameter | V DD | Typical formula | where: |
|---|---|---|---|---|
| P D | dynamic power dissipation | 5 V | P = 600 × f + Σ(f × C ) × V 2 (μW) D i o L DD | f = input frequency in MHz; i f = output frequency in MHz; o C = output load capacitance in pF; L Σ(f × C ) = sum of the outputs; o L V = supply voltage in V. DD |
| 10 V | P = 2700 × f + Σ(f × C ) × V 2 (μW) D i o L DD | |||
| 15 V | P = 8400 × f + Σ(f × C ) × V 2 (μW) D i o L DD |
5 / 11
Page 6
10.1 Waveforms and test circuit

Table 9. Measurement points
| Supply voltage | Input | Output |
| V DD | V M | V M |
| 5 V to 15 V | 0.5V DD | 0.5V DD |

Table 10. Test data
| Supply voltage | Input | Load | |
| V DD | V I | t, t r f | C L |
| 5 V to 15 V | V or V SS DD | ≤ 20 ns | 50 pF |
6 / 11
Page 7
11 Package outline



7 / 11
Page 8
12 Abbreviations
Table 11. Abbreviations
| Acronym | Description |
|---|---|
| DUT | Device Under Test |
13 Revision history
Table 12. Revision history
| Document ID | Release date | Data sheet status | Change notice | Supersedes |
| HEF4073B v.4 | 20171006 | Product data sheet | - | HEF4073B_CNV v.3 |
| Modifications: | • The format of this data sheet has been redesigned to comply with the identity guidelines of Nexperia. • Legal texts have been adapted to the new company name where appropriate. • Type numbers HEF4073BP and HEF4073BD removed. | |||
| HEF4073B_CNV v.3 | 19950101 | Product specification | - | - |
8 / 11
Page 9
14 Legal information
14.1 Data sheet status
| Document status[1][2] | Product status[3] | Definition |
| Objective [short] data sheet | Development | This document contains data from the objective specification for product development. |
| Preliminary [short] data sheet | Qualification | This document contains data from the preliminary specification. |
| Product [short] data sheet | Production | This document contains the product specification. |
[1] Please consult the most recently issued document before initiating or completing a design. [2] The term 'short data sheet' is explained in section "Definitions". [3] The product status of device(s) described in this document may have changed since this document was published and may differ in case of multiple devices. The latest product status information is available on the Internet at URL http://www.nexperia.com.
14.2 Definitions
Draft — The document is a draft version only. The content is still under internal review and subject to formal approval, which may result in modifications or additions. Nexperia does not give any representations or warranties as to the accuracy or completeness of information included herein and shall have no liability for the consequences of use of such information.
Short data sheet — A short data sheet is an extract from a full data sheet with the same product type number(s) and title. A short data sheet is intended for quick reference only and should not be relied upon to contain detailed and full information. For detailed and full information see the relevant full data sheet, which is available on request via the local Nexperia sales office. In case of any inconsistency or conflict with the short data sheet, the full data sheet shall prevail.
Product specification — The information and data provided in a Product data sheet shall define the specification of the product as agreed between Nexperia and its customer, unless Nexperia and customer have explicitly agreed otherwise in writing. In no event however, shall an agreement be valid in which the Nexperia product is deemed to offer functions and qualities beyond those described in the Product data sheet.
14.3 Disclaimers
Limited warranty and liability — Information in this document is believed to be accurate and reliable. However, Nexperia does not give any representations or warranties, expressed or implied, as to the accuracy or completeness of such information and shall have no liability for the consequences of use of such information. Nexperia takes no responsibility for the content in this document if provided by an information source outside of Nexperia. In no event shall Nexperia be liable for any indirect, incidental, punitive, special or consequential damages (including - without limitation - lost profits, lost savings, business interruption, costs related to the removal
or replacement of any products or rework charges) whether or not such damages are based on tort (including negligence), warranty, breach of contract or any other legal theory. Notwithstanding any damages that customer might incur for any reason whatsoever, Nexperia's aggregate and cumulative liability towards customer for the products described herein shall be limited in accordance with the Terms and conditions of commercial sale of Nexperia.
Right to make changes — Nexperia reserves the right to make changes to information published in this document, including without limitation specifications and product descriptions, at any time and without notice. This document supersedes and replaces all information supplied prior to the publication hereof.
Suitability for use — Nexperia products are not designed, authorized or warranted to be suitable for use in life support, life-critical or safety-critical
systems or equipment, nor in applications where failure or malfunction of an Nexperia product can reasonably be expected to result in personal injury, death or severe property or environmental damage. Nexperia and its suppliers accept no liability for inclusion and/or use of Nexperia products in such equipment or applications and therefore such inclusion and/or use is at the customer’s own risk.
Applications — Applications that are described herein for any of these products are for illustrative purposes only. Nexperia makes no representation or warranty that such applications will be suitable for the specified use without further testing or modification. Customers are responsible for the design and operation of their applications and products using Nexperia products, and Nexperia accepts no liability for any assistance with applications or customer product design. It is customer’s sole responsibility to determine whether the Nexperia product is suitable and fit for the customer’s applications and products planned, as well as for the planned application and use of customer’s third party customer(s). Customers should
provide appropriate design and operating safeguards to minimize the risks associated with their applications and products. Nexperia does not accept any liability related to any default, damage, costs or problem which is based on any weakness or default in the customer’s applications or products, or the application or use by customer’s third party customer(s). Customer is responsible for doing all necessary testing for the customer’s applications and products using Nexperia products in order to avoid a default of the applications and the products or of the application or use by customer’s third party customer(s). Nexperia does not accept any liability in this respect.
Limiting values — Stress above one or more limiting values (as defined in the Absolute Maximum Ratings System of IEC 60134) will cause permanent damage to the device. Limiting values are stress ratings only and (proper) operation of the device at these or any other conditions above those given in the Recommended operating conditions section (if present) or the Characteristics sections of this document is not warranted. Constant or repeated exposure to limiting values will permanently and irreversibly affect the quality and reliability of the device.
Terms and conditions of commercial sale — Nexperia products are sold subject to the general terms and conditions of commercial sale, as published at http://www.nexperia.com/profile/terms, unless otherwise agreed in a valid written individual agreement. In case an individual agreement is concluded only the terms and conditions of the respective agreement shall apply. Nexperia hereby expressly objects to applying the customer’s general terms and conditions with regard to the purchase of Nexperia products by customer.
No offer to sell or license — Nothing in this document may be interpreted or construed as an offer to sell products that is open for acceptance or the grant, conveyance or implication of any license under any copyrights, patents or other industrial or intellectual property rights.
Export control — This document as well as the item(s) described herein may be subject to export control regulations. Export might require a prior authorization from competent authorities.
9 / 11
Page 10
Non-automotive qualified products — Unless this data sheet expressly states that this specific Nexperia product is automotive qualified, the product is not suitable for automotive use. It is neither qualified nor tested in accordance with automotive testing or application requirements. Nexperia accepts no liability for inclusion and/or use of non-automotive qualified products in automotive equipment or applications. In the event that customer uses the product for design-in and use in automotive applications to automotive specifications and standards, customer (a) shall use the product without Nexperia's warranty of the product for such automotive applications,
use and specifications, and (b) whenever customer uses the product for automotive applications beyond Nexperia's specifications such use shall be solely at customer’s own risk, and (c) customer fully indemnifies Nexperia for any liability, damages or failed product claims resulting from customer
design and use of the product for automotive applications beyond Nexperia's standard warranty and Nexperia's product specifications.
Translations — A non-English (translated) version of a document is for reference only. The English version shall prevail in case of any discrepancy between the translated and English versions.
14.4 Trademarks
Notice: All referenced brands, product names, service names and trademarks are the property of their respective owners.
10 / 11
Page 11
Contents
1 General description ............................................ 1 2 Features and benefits .........................................1 3 Ordering information .......................................... 1 4 Functional diagram .............................................1 5 Pinning information ............................................ 2 5.1 Pinning ...............................................................2 5.2 Pin description ...................................................2 6 Functional description ........................................2 7 Limiting values ....................................................3 8 Recommended operating conditions ................3
9 Static characteristics ..........................................4 10 Dynamic characteristics .....................................5 10.1 Waveforms and test circuit ................................ 6 11 Package outline ...................................................7 12 Abbreviations ...................................................... 8 13 Revision history .................................................. 8 14 Legal information ................................................9
Please be aware that important notices concerning this document and the product(s) described herein, have been included in section 'Legal information'.
© Nexperia B.V. 2017.
All rights reserved.
For more information, please visit: http://www.nexperia.com For sales office addresses, please send an email to: salesaddresses@nexperia.com
Date of release: 6 October 2017 Document identifier: HEF4073B