1. General description

The HEF4069UB is a hex unbuffered inverter. Inputs include clamp diodes. This enables the use of current limiting resistors to interface inputs to voltages in excess of VDD.

2. Features and benefits

  • Wide supply voltage range from 3.0 V to 15.0 V
  • CMOS low power dissipation
  • High noise immunity
  • Fully static operation
  • 5 V, 10 V, and 15 V parametric ratings
  • Standardized symmetrical output characteristics
  • Complies with JEDEC standard JESD 13-B
  • ESD protection:
  • HBM JESD22-A114F exceeds 2000 V
  • MM JESD22-A115-B exceeds 200 V
  • Specified from -40 °C to +85 °C and -40 °C to +125 °C

3. Applications

  • Oscillator

4. Ordering information

Table 1. Ordering information

Type number Package
Temperature rannge Name Description Version
HEF4069UBT -40 °C to +125 °C SO14 plastic small outline package; 14 leads; body width 3.9 mm SOT108-1
HEF4069UBTT -40 °C to +125 °C TSSOP14 plastic thin shrink small outline package; 14 leads; body width 4.4 mm SOT402-1

Page 2

5. Functional diagram

PDF page 2 diagram

6. Pinning information

6.1. Pinning

PDF page 2 diagram

6.2. Pin description

Table 2. Pin description

Symbol Pin Description
1A, 2A, 3A, 4A, 5A, 6A 1, 3, 5, 9, 11, 13 input
1Y, 2Y, 3Y, 4Y, 5Y, 6Y 2, 4, 6, 8, 10, 12 output
V SS 7 ground (0 V)
V DD 14 supply voltage

2 / 13

Page 3

7. Limiting values

Table 3. Limiting values In accordance with the Absolute Maximum Rating System (IEC 60134).

Symbol Parameter Conditions Min Max Unit
V DD supply voltage -0.5 +18 V
I IK input clamping current V < -0.5 V or V > V + 0.5 V I I DD - ±10 mA
V I input voltage -0.5 V + 0.5 DD V
I OK output clamping current V < -0.5 V or V > V + 0.5 V O O DD - ±10 mA
I I/O input/output current - ±10 mA
I DD supply current - 50 mA
T stg storage temperature -65 +150 °C
T amb ambient temperature -40 +125 °C
P tot total power dissipation T = -40 °C to +125 °C [1] amb - 500 mW
P power dissipation per output - 100 mW

[1] For SOT108-1 (SO14) package: Ptot derates linearly with 10.1 mW/K above 100 °C. For SOT402-1 (TSSOP14) package: Ptot derates linearly with 7.3 mW/K above 81 °C.

8. Recommended operating conditions

Table 4. Recommended operating conditions

Symbol Parameter Conditions Min Typ Max Unit
V DD supply voltage 3 - 15 V
V I input voltage 0 - V DD V
T amb ambient temperature in free air -40 - +125 °C

9. Static characteristics

Table 5. Static characteristics VSS = 0 V; VI = VSS or VDD; unless otherwise specified.

Symbol Parameter Conditions V DD T = -40 °C amb T = +25 °C amb T = +85 °C amb T = +125 °C amb Unit
Min Max Min Max Min Max Min Max
V IH HIGH-level input voltage |I | < 1 μA O 5 V 4 - 4 - 4 - 4 - V
10 V 8 - 8 - 8 - 8 - V
15 V 12.5 - 12.5 - 12.5 - 12.5 - V
V IL LOW-level input voltage |I | < 1 μA O 5 V - 1 - 1 - 1 - 1 V
10 V - 2 - 2 - 2 - 2 V
15 V - 2.5 - 2.5 - 2.5 - 2.5 V
V OH HIGH-level output voltage |I | < 1 μA O 5 V 4.95 - 4.95 - 4.95 - 4.95 - V
10 V 9.95 - 9.95 - 9.95 - 9.95 - V
15 V 14.95 - 14.95 - 14.95 - 14.95 - V
V OL LOW-level output voltage |I | < 1 μA O 5 V - 0.05 - 0.05 - 0.05 - 0.05 V
10 V - 0.05 - 0.05 - 0.05 - 0.05 V
15 V - 0.05 - 0.05 - 0.05 - 0.05 V

3 / 13

Page 4

Symbol Parameter Conditions V DD T = -40 °C amb T = +25 °C amb T = +85 °C amb T = +125 °C amb Unit
Min Max Min Max Min Max Min Max
I OH HIGH-level output current V = 2.5 V O 5 V - -1.7 - -1.4 - -1.1 - -1.1 mA
V = 4.6 V O 5 V - -0.64 - -0.5 - -0.36 - -0.36 mA
V = 9.5 V O 10 V - -1.6 - -1.3 - -0.9 - -0.9 mA
V = 13.5 V O 15 V - -4.2 - -3.4 - -2.4 - -2.4 mA
I OL LOW-level output current V = 0.4 V O 5 V 0.64 - 0.5 - 0.36 - 0.36 - mA
V = 0.5 V O 10 V 1.6 - 1.3 - 0.9 - 0.9 - mA
V = 1.5 V O 15 V 4.2 - 3.4 - 2.4 - 2.4 - mA
I I input leakage current 15 V - ±0.1 - ±0.1 - ±1.0 - ±1.0 μA
I DD supply current all valid input combinations; I = 0 A O 5 V - 0.25 - 0.25 - 7.5 - 7.5 μA
10 V - 0.5 - 0.5 - 15.0 - 15.0 μA
15 V - 1.0 - 1.0 - 30.0 - 30.0 μA
C I input capacitance digital inputs - - - 7.5 - - - - pF

10. Dynamic characteristics

Table 6. Dynamic characteristics Tamb = 25 °C; for waveforms see Fig. 4; for test circuit see Fig. 5.

Symbol Parameter Conditions V DD Extrapolation formula [1] Min Typ Max Unit
t PHL HIGH to LOW propagation delay nA to nY 5 V 18 ns + (0.55 ns/pF)C L - 45 90 ns
10 V 9 ns + (0.23 ns/pF)C L - 20 40 ns
15 V 7 ns + (0.16 ns/pF)C L - 15 25 ns
t PLH LOW to HIGH propagation delay nA to nY 5 V 13 ns + (0.55 ns/pF)C L - 40 80 ns
10 V 9 ns + (0.23 ns/pF)C L - 20 40 ns
15 V 7 ns + (0.16 ns/pF)C L - 15 30 ns
t THL HIGH to LOW output transition time output nY 5 V 10 ns + (1.00 ns/pF)C L - 60 120 ns
10 V 9 ns + (0.42 ns/pF)C L - 30 60 ns
15 V 6 ns + (0.28 ns/pF)C L - 20 40 ns
t TLH LOW to HIGH output transition time output nY 5 V 10 ns + (1.00 ns/pF)C L - 60 120 ns
10 V 9 ns + (0.42 ns/pF)C L - 30 60 ns
15 V 6 ns + (0.28 ns/pF)C L - 20 40 ns

[1] The typical value of the propagation delay and output transition time can be calculated with the extrapolation formula (CL in pF).

Table 7. Dynamic power dissipation VSS = 0 V; tr = tf ≤ 20 ns; Tamb = 25 °C.

Symbol Parameter V DD Typical formula Where
P D dynamic power dissipation 5 V P = 600 × f + Σ(f × C ) × V 2 (μW) D i o L DD f = input frequency in MHz; i f = output frequency in MHz; o C = output load capacitance in pF; L Σ(f × C ) = sum of the outputs; o L V = supply voltage in V. DD
10 V P = 4000 × f + Σ(f × C ) × V 2 (μW) D i o L DD
15 V P = 22000 × f + Σ(f × C ) × V 2 (μW) D i o L DD

4 / 13

Page 5

10.1. Waveforms and test circuit

PDF page 5 diagram
PDF page 5 diagram

Table 8. Test data

Supply voltage Input Load
V DD V I t, t r f C L
5 V to 15 V V or V SS DD ≤ 20 ns 50 pF

5 / 13

Page 6

10.2. Transfer characteristics

PDF page 6 diagram

6 / 13

Page 7

11. Application information

Some examples of applications for HEF4069UB.

Fig. 7 shows an astable relaxation oscillator using two HEF4069UB inverters and two BAW62 diodes. The oscillation frequency is mainly determined by R1 × C1, provided R1 << R2 and R2 × C2 << R1 × C1.

The function of R2 is to minimize the influence of the forward voltage across the protection diodes on the frequency; C2 is a stray (parasitic) capacitance.

The period Tp is given by Tp = T1 + T2, where:

VST = the signal threshold level of the inverter. The period is fairly independent of VDD, VST and temperature. The duty factor, however, is influenced by VST.

PDF page 7 diagram

Fig. 8 shows a crystal oscillator for frequencies up to 10 MHz using two HEF4069UB inverters. The second inverter amplifies the oscillator output voltage to a level sufficient to drive other Local Oxidation CMOS (LOCMOS) circuits.

PDF page 7 diagram

7 / 13

Page 8

Fig. 9 and Fig. 10 show voltage gain and supply current. Fig. 11 shows the test set-up and an example of an analog amplifier using one HEF4069UB.

PDF page 8 diagram
PDF page 8 diagram

Fig. 12 shows typical forward transconductance. Fig. 13 shows the test set-up.

PDF page 8 diagram

8 / 13

Page 9

12. Package outline

SO14: plastic small outline package; 14 leads; body width 3.9 mm

SOT108-1

PDF page 9 diagram
PDF page 9 diagram
PDF page 9 diagram

Fig. 14. Package outline SOT108-1 (SO14)

9 / 13

Page 10

TSSOP14: plastic thin shrink small outline package; 14 leads; body width 4.4 mm

SOT402-1

PDF page 10 diagram
PDF page 10 diagram
PDF page 10 diagram

Fig. 15. Package outline SOT402-1 (TSSOP14)

10 / 13

Page 11

13. Abbreviations

Table 9. Abbreviations

Acronym Description
CMOS Complementary Metal-Oxide Semiconductor
DUT Device Under Test
ESD ElectroStatic Discharge
HBM Human Body Model
LOCMOS Local Oxidation Complementary Metal-Oxide Semiconductor
MM Machine Model

14. Revision history

Table 10. Revision history

Document ID Release date Data sheet status Change notice Supersedes
HEF4069UB v.10 20220210 Product data sheet - HEF4069UB v.9
Modifications: • The format of this data sheet has been redesigned to comply with the identity guidelines of Nexperia. • Legal texts have been adapted to the new company name where appropriate. • Section 1 and Section 2 updated. • Table 3: Derating values for P total power dissipation updated. tot
HEF4069UB v.9 20151216 Product data sheet - HEF4069UB v.8
Modifications: • Type number HEF4069UBP (SOT27-1) removed.
HEF4069UB v.8 20111116 Product data sheet - HEF4069UB v.7
Modifications: • Legal pages updated. • Changes in "General description", "Features and benefits" and "Applications".
HEF4069UB v.7 20110511 Product data sheet - HEF4069UB v.6
HEF4069UB v.6 20091208 Product data sheet - HEF4069UB v.5
HEF4069UB v.5 20090723 Product data sheet - HEF4069UB v.4
HEF4069UB v.4 20080704 Product data sheet - HEF4069UB_CNV v.3
HEF4069UB_CNV v.3 19950101 Product specification - HEF4069UB_CNV v.2
HEF4069UB_CNV v.2 19950101 Product specification - -

11 / 13

Page 12

15. Legal information

Data sheet status

Document status [1][2] Product status [3] Definition
Objective [short] data sheet Development This document contains data from the objective specification for product development.
Preliminary [short] data sheet Qualification This document contains data from the preliminary specification.
Product [short] data sheet Production This document contains the product specification.

[1] Please consult the most recently issued document before initiating or completing a design. [2] The term 'short data sheet' is explained in section "Definitions". [3] The product status of device(s) described in this document may have changed since this document was published and may differ in case of multiple devices. The latest product status information is available on the internet at https://www.nexperia.com.

Definitions

Draft — The document is a draft version only. The content is still under internal review and subject to formal approval, which may result in modifications or additions. Nexperia does not give any representations or warranties as to the accuracy or completeness of information included herein and shall have no liability for the consequences of use of such information.

Short data sheet — A short data sheet is an extract from a full data sheet with the same product type number(s) and title. A short data sheet is intended for quick reference only and should not be relied upon to contain detailed and full information. For detailed and full information see the relevant full data sheet, which is available on request via the local Nexperia sales office. In case of any inconsistency or conflict with the short data sheet, the full data sheet shall prevail.

Product specification — The information and data provided in a Product data sheet shall define the specification of the product as agreed between Nexperia and its customer, unless Nexperia and customer have explicitly agreed otherwise in writing. In no event however, shall an agreement be valid in which the Nexperia product is deemed to offer functions and qualities beyond those described in the Product data sheet.

Disclaimers

Limited warranty and liability — Information in this document is believed to be accurate and reliable. However, Nexperia does not give any representations or warranties, expressed or implied, as to the accuracy or completeness of such information and shall have no liability for the consequences of use of such information. Nexperia takes no responsibility for the content in this document if provided by an information source outside of Nexperia.

In no event shall Nexperia be liable for any indirect, incidental, punitive, special or consequential damages (including - without limitation - lost profits, lost savings, business interruption, costs related to the removal or replacement of any products or rework charges) whether or not such damages are based on tort (including negligence), warranty, breach of contract or any other legal theory.

Notwithstanding any damages that customer might incur for any reason whatsoever, Nexperia’s aggregate and cumulative liability towards customer for the products described herein shall be limited in accordance with the Terms and conditions of commercial sale of Nexperia.

Right to make changes — Nexperia reserves the right to make changes to information published in this document, including without limitation specifications and product descriptions, at any time and without notice. This document supersedes and replaces all information supplied prior to the publication hereof.

Suitability for use — Nexperia products are not designed, authorized or warranted to be suitable for use in life support, life-critical or safety-critical systems or equipment, nor in applications where failure or malfunction of an Nexperia product can reasonably be expected to result in personal

injury, death or severe property or environmental damage. Nexperia and its suppliers accept no liability for inclusion and/or use of Nexperia products in such equipment or applications and therefore such inclusion and/or use is at the customer’s own risk.

Quick reference data — The Quick reference data is an extract of the product data given in the Limiting values and Characteristics sections of this document, and as such is not complete, exhaustive or legally binding.

Applications — Applications that are described herein for any of these products are for illustrative purposes only. Nexperia makes no representation or warranty that such applications will be suitable for the specified use without further testing or modification.

Customers are responsible for the design and operation of their applications and products using Nexperia products, and Nexperia accepts no liability for any assistance with applications or customer product design. It is customer’s sole responsibility to determine whether the Nexperia product is suitable and fit for the customer’s applications and products planned, as well as for the planned application and use of customer’s third party customer(s). Customers should provide appropriate design and operating safeguards to minimize the risks associated with their applications and products.

Nexperia does not accept any liability related to any default, damage, costs or problem which is based on any weakness or default in the customer’s applications or products, or the application or use by customer’s third party customer(s). Customer is responsible for doing all necessary testing for the customer’s applications and products using Nexperia products in order to avoid a default of the applications and the products or of the application or use by customer’s third party customer(s). Nexperia does not accept any liability in this respect.

Limiting values — Stress above one or more limiting values (as defined in the Absolute Maximum Ratings System of IEC 60134) will cause permanent damage to the device. Limiting values are stress ratings only and (proper) operation of the device at these or any other conditions above those given in the Recommended operating conditions section (if present) or the Characteristics sections of this document is not warranted. Constant or repeated exposure to limiting values will permanently and irreversibly affect the quality and reliability of the device.

Terms and conditions of commercial sale — Nexperia products are sold subject to the general terms and conditions of commercial sale, as published at http://www.nexperia.com/profile/terms, unless otherwise agreed in a valid written individual agreement. In case an individual agreement is concluded only the terms and conditions of the respective agreement shall apply. Nexperia hereby expressly objects to applying the customer’s general terms and conditions with regard to the purchase of Nexperia products by customer.

No offer to sell or license — Nothing in this document may be interpreted or construed as an offer to sell products that is open for acceptance or the grant, conveyance or implication of any license under any copyrights, patents or other industrial or intellectual property rights.

Export control — This document as well as the item(s) described herein may be subject to export control regulations. Export might require a prior authorization from competent authorities.

Non-automotive qualified products — Unless this data sheet expressly states that this specific Nexperia product is automotive qualified, the product is not suitable for automotive use. It is neither qualified nor tested in accordance with automotive testing or application requirements. Nexperia accepts no liability for inclusion and/or use of non-automotive qualified products in automotive equipment or applications.

In the event that customer uses the product for design-in and use in automotive applications to automotive specifications and standards, customer (a) shall use the product without Nexperia’s warranty of the product for such automotive applications, use and specifications, and (b) whenever customer uses the product for automotive applications beyond Nexperia’s specifications such use shall be solely at customer’s own risk, and (c) customer fully indemnifies Nexperia for any liability, damages or failed product claims resulting from customer design and use of the product for automotive applications beyond Nexperia’s standard warranty and Nexperia’s product specifications.

Translations — A non-English (translated) version of a document is for reference only. The English version shall prevail in case of any discrepancy between the translated and English versions.

Trademarks

Notice: All referenced brands, product names, service names and trademarks are the property of their respective owners.

12 / 13

Page 13

Contents

  1. General description......................................................1 2. Features and benefits.................................................. 1 3. Applications.................................................................. 1 4. Ordering information....................................................1 5. Functional diagram.......................................................2 6. Pinning information......................................................2 6.1. Pinning.........................................................................2 6.2. Pin description.............................................................2 7. Limiting values............................................................. 3
  1. Recommended operating conditions..........................3 9. Static characteristics....................................................3 10. Dynamic characteristics............................................ 4 10.1. Waveforms and test circuit........................................ 5 10.2. Transfer characteristics..............................................6 11. Application information..............................................7 12. Package outline.......................................................... 9 13. Abbreviations............................................................11 14. Revision history........................................................11
  1. Legal information......................................................12

For more information, please visit: http://www.nexperia.com For sales office addresses, please send an email to: salesaddresses@nexperia.com Date of release: 10 February 2022

13 / 13