GC0351M CUID
Document overview
- PDF pages: 3
Technical content
Page 1
date 08/05/2022 page 1 of 3
MODEL: GC0351M | DESCRIPTION: SPEAKER

FEATURES
- 16 x 35 mm
- rectangular frame
- 0.5 W
- 8 Ω
- neodymium magnet
- cloth cone
SPECIFICATIONS
parameter
conditions/description
min
typ
max
units
input power
0.5
1.0
W Ω
impedance
at 1.0 kHz, 1.0 V
6.8
8 9.2
resonant frequency (Fo)
at 1.0 V
520
650
780
Hz
frequency response
Fo
20,000
Hz
sound pressure level
at 1.0 W, 50 cm, avg at 0.8, 1.0, 1.2, 1.5 kHz
78
81
84
dB
buzz, rattle, etc.
must be normal at sine wave
2.83
V
dimensions
35 x 16 x 5
mm
magnet
Nd-Fe-B
cone material
cloth
terminal
solder pads
weight
2.6
g
operating temperature
-25
60
°C
hand soldering
for maximum 3 seconds
340
350
360
°C
RoHS
yes
Page 2
CUI DEVICES | MODEL: GC0351M | DESCRIPTION: SPEAKER
date 08/05/2022 | page 2 of 3
MECHANICAL DRAWING
units: mm tolerance: ±0.2 mm

FREQUENCY RESPONSE CURVE
parameter
conditions/description
potentiometer range
50 dB
rectifier
RMS
lower limit frequency
20 Hz
wr. speed
100 mm/sec
zero level
60 dB

Page 3
CUI DEVICES | MODEL: GC0351M | DESCRIPTION: SPEAKER
date 08/05/2022 | page 3 of 3
REVISION HISTORY
| rev. | description | date |
|---|---|---|
| 1.0 | initial release | 03/03/2009 |
| 1.01 | brand update | 05/20/2020 |
| 1.02 | logo, datasheet style update | 08/05/2022 |
The revision history provided is for informational purposes only and is believed to be accurate.
CUI Devices offers a one (1) year limited warranty. Complete warranty information is listed on our website.
CUI Devices reserves the right to make changes to the product at any time without notice. Information provided by CUI Devices is believed to be accurate and reliable. However, no responsibility is assumed by CUI Devices for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI Devices products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.