GA5M YUANDEAN

Document overview

  • Manufacturer or author: Provided By www.digicamel.com(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

FEATURES:  Universal Input 80~264VAC  Medical safety design refer to (2 X MOPP) according to ANSI/AAMI ES60601-1 and IEC/EN60601-1  Suitable for BF application with appropriate system consideration  No load power consumption<0.1W  Extremely low leakage current  EMI class B for class Ⅱ configuration  Protection: Short Circuit / Overload / Over Voltage / Over Temperature  No minimum load required  3 Years Warranty  ROHS Compliant Applications:  Portable medical device  Mobile clinical workstaion  Medical computer monitor  Medical examination instrument AC-DC Converter GA5M SERIES 5Watt 4KVac Isolated Single Output 2” x 1” Package Module Specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified Part Number Output Wattage Output Voltage Output Current Ripple & Noise Efficiency (W) (VDC) (mA) (mV) max(Note) (TYP %) GA5M-S05 5.0 5 1000 100 76 GA5M-S12 5.0 12 420 150 80 GA5M-S15 5.0 15 330 150 81 GA5M-S24 5.0 24 230 180 82 YUAN DEAN SCIENTIFIC YUAN DEAN SCIENTIFIC CO.,LTD Rev:0 2017/10/05 GA5M SERIES Temperature Derating Graph 100 OutPut Power(%) -40 60 Nature Convection Ambient Temperature(℃) 70 8085 Input Specifications Parameters Conditions Min Typ Max Units Rated Input Voltage Vo,Io nom 100~240 Vac Voltage Range Vo,Io nom AC in 80 264 Vac DC in 105 370 Vdc Line frequency Vi nom,Io nom 47 50/60 63 Hz Inrush Current Io nom Vi:115VAC 25 A Vi:230VAC 45 A Input Current (Full load) 0.2A (115Vac) 0.1A (230Vac) Input Fuse VDE/UL/CCC FUSE 2.5A/250V (Slow blow) Notes: Ripple & noise is measured by using 20 MHz bandwidth, measured with a 47uf paralleled with a high-frequency 0.47uf capacitor across each output by full load.

Parameters Conditions Min Typ Max Units Isolation Voltage Input / Output 4KVac/ 5mA/60Secs Isolation Resistance Input / Output, @500 Vdc 100 MΩ Operating Temperature Operating at Vi nom,Io nom -40 +85 ℃ Storage Temperature Non Operational -40 +100 ℃ Relative Humidity Vi nom,Io nom 95 % RH Dimension L50.80x W25.40 x H17.02mm Cooling Free air convection Output Derating VS Input Voltage GA5M SERIES YUAN DEAN SCIENTIFIC CO.,LTD Rev:0 2017/10/05 Output Specifications Parameters Conditions Min Typ Max Units Output Voltage Accuracy Vi nom, Io nom 5V Models ±3 % 12/15/24V Models ±2 % Minimum Load Vi nom 0 % Line Regulation Io nom, Vi min…Vi max ±0.3 % Load Regulation Vi nom, Io min…Io nom ±0.5 % Protection Over load Above 110% rated output power Protection type: Recovers automatically after fault condition is removed Short circuit Recovers automatically after fault condition is removed Over Voltage 110%-150% rated output Voltage Protection type: Zener diode clamp Over Temperature Protection type: Shut down o/p voltage, recovers automatically after temperature goes down Part Number 6.0TYP 1.0±0.05 45.72 20.32 25.40 50.80 10.16 20.32 17.02 BOTTOM VIEW FRONT VIEW Markings and Dimensions Unit:mm , Unless otherwise specified, all tolerances are ±0.50 PIN Connection PIN 1 2 3 4 GA5M ACN ACL -Vo +Vo Circuit Schematic Rectifier Line Filter Inrush Current Limiter and Rectifier Switching Device Control Circuit Opto- Isolation Reference & Error Amp L N Vo + Vo - Fuse Load(%) Input Voltage(V)60Hz 95 100 115 120 140 160 180 200 220 240 264 100