FEATURES: Universal Input 80~264VAC Medical safety design refer to (2 X MOPP) according to ANSI/AAMI ES60601-1 and IEC/EN60601-1 Suitable for BF application with appropriate system consideration No load power consumption<0.1W Extremely low leakage current EMI class B for class Ⅱ configuration Protection: Short Circuit / Overload / Over Voltage / Over Temperature No minimum load required 3 Years Warranty ROHS Compliant Applications: Portable medical device Mobile clinical workstaion Medical computer monitor Medical examination instrument AC-DC Converter GA10M SERIES 10Watt 4KVac Isolated Single Output 2” x 1” Package Module Specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified Part Number Output Wattage Output Voltage Output Current Ripple & Noise Efficiency (W) (VDC) (mA) (mV) max(Note) (TYP %) GA10M-S05 10 5 2000 100 79 GA10M-S12 10.2 12 850 180 82 GA10M-S15 10 15 670 180 82 GA10M-S24 11 24 460 200 83 YUAN DEAN SCIENTIFIC YUAN DEAN SCIENTIFIC CO.,LTD Rev:0 2017/12/25 GA10M SERIES Temperature Derating Graph 100 OutPut Power(%) -25 60 Nature Convection Ambient Temperature(℃) 70 8085 Input Specifications Parameters Conditions Min Typ Max Units Rated Input Voltage Vo, Io nom 100~240 Vac Voltage Range Vo, Io nom AC in 80 264 Vac DC in 105 370 Vdc Line frequency Vi nom, Io nom 47 50/60 63 Hz Inrush Current Io nom Vi:115VAC 25 A Vi:230VAC 45 A Input Current (Full load) 0.3A (115Vac) 0.2A (230Vac) Input Fuse VDE/UL/CCC FUSE 2.5A/250V (Slow blow) Notes: Ripple & noise is measured by using 20 MHz bandwidth, measured with a 47uf paralleled with a high-frequency 0.47uf capacitor across each output by full load.
Parameters Conditions Min Typ Max Units Isolation Voltage Input / Output 4KVac/ 5mA/60Secs Isolation Resistance Input / Output, @500 Vdc 100 MΩ Operating Temperature Operating at Vi nom, Io nom -25 +85 ℃ Storage Temperature Non Operational -40 +100 ℃ Relative Humidity Vi nom, Io nom 95 % RH Dimension L50.80x W25.40 x H17.02mm Cooling Free air convection Output Derating VS Input Voltage GA10M SERIES YUAN DEAN SCIENTIFIC CO.,LTD Rev:0 2017/12/25 Output Specifications Parameters Conditions Min Typ Max Units Output Voltage Accuracy Vi nom, Io nom 5V Models ±3 % 12/15/24V Models ±2 % Minimum Load Vi nom 0 % Line Regulation Io nom, Vi min…Vi max ±0.3 % Load Regulation Vi nom, Io min…Io nom ±0.5 % Protection Over load Above 110% rated output power Protection type: Recovers automatically after fault condition is removed Short circuit Recovers automatically after fault condition is removed Over Voltage 110%-150% rated output Voltage Protection type: Zener diode clamp Over Temperature Protection type: Shut down o/p voltage, recovers automatically after temperature goes down Part Number GA10M - S 05 A B C A : Series B : Single Output C : Output Voltage 6.0TYP 1.0±0.05 45.72 20.32 25.40 50.80 10.16 20.32 17.02 BOTTOM VIEW FRONT VIEW Markings and Dimensions Unit:mm Unless otherwise specified, all tolerances are ±0.50 PIN Connection PIN 1 2 3 4 GA10M ACN ACL -Vo +Vo Circuit Schematic Rectifier Line Filter Inrush Current Limiter and Rectifier Switching Device Control Circuit Opto- Isolation Reference & Error Amp L N Vo + Vo - Fuse Load(%) Input Voltage(V)60Hz 95 100 115 120 140 160 180 200 220 240 264 100