Maximum Flow Rate: 248.7 l/min (65.7 gpm) Maximum Pressure: 48 bar (700 psi) for Metallic Pump Heads 17 bar (250 psi) for Non-metallic Pump Heads G66 Version 4b 07/19 G66 with Ductile Iron pump head G66 with Polypropylene pump head
2 • www.Hydra-Cell.co.uk G66 Version 4b 07/19 Metering & Dosing For applications requiring API 675 performance testing, please contact Wanner International. G66 Series Performance Flow Max. Max. Flow Input @ 48 bar (700 psi) Model rpm gpm l/min G66-X 1000 65.7 248.7 Pressure Maximum Inlet Pressure Metallic Pump Heads: 17 bar (250 psi) Non-metallic Pump Heads: 3.4 bar (50 psi) Maximum Discharge Pressure Metallic Pump Heads: 48 bar (700 psi) Non-metallic Pump Heads: 17 bar (250 psi) Capacities Maximum Flow at Designated Pressure Performance and specification ratings apply to G66 configurations unless specifically noted otherwise. 70.0 60.0 50.0 40.0 30.0 20.0 10.0 0 1000800600400200 14 bar (200 psi) 48 bar (700 psi) G66-X Gallons Per Minute Litres Per Minute Revolutions Per Minute 264.9 227.1 189.3 151.4 113.6 75.7 37.9
www.Hydra-Cell.co.uk • 3 G66 Series API 674 Performance 0 200 400 600 800 1000 1200 Pressure (bar) Pump Speed (rpm) G66 G66Operation on or below line complies with Item 6.8.2 of API-674 Flow Max. Max. Flow Input @ 48 bar (700 psi) Model rpm gpm l/min G66-X 1000 65.7 248 Pressure Maximum Inlet Pressure Metallic Pump Heads: 17 bar (250 psi) Non-metallic Pump Heads: 3.4 bar (50 psi) Maximum Discharge Pressure Metallic Pump Heads: 48 bar (700 psi) @ 1000 rpm max. Non-metallic Pump Heads: 17 bar (250 psi) Capacities Maximum RPM at Designated Pressure Performance and specification ratings apply to G66 configurations unless specifically noted otherwise. G66 Version 4b 07/19
4 • www.Hydra-Cell.co.uk G66 Version 4b 07/19 G66 Series Specifications Flow Capacities @ 14 bar (200 psi) Model rpm gpm l/min G66-X (Metallic) 1000 67.8 256 Flow Capacities @ 17 bar (250 psi) Model rpm gpm l/min G66-X (Non-metallic) 1000 67.5 255 Flow Capacities @ 48 bar (700 psi) Model rpm gpm l/min G66-X (Metallic) 1000 65.7 248 Delivery @ 14 bar (200 psi) Model gal/rev liters/rev G66-X (Metallic) 0.0678 0.256 Delivery @ 17 bar (250 psi) Model gal/rev liters/rev G66-X (Non-metallic) 0.0675 0.255 Delivery @ 48 bar (700 psi) Model gal/rev liters/rev G66-X (Metallic) 0.0657 0.248 Maximum Discharge Pressure Metallic Heads: 48 bar (700 psi) Non-metallic Heads: 17 bar (250 psi) Maximum Inlet Pressure Metallic Heads: 17 bar (250 psi) Non-metallic Heads: 3.4 bar (50 psi) Maximum Operating Temperature Metallic Heads: 93.3˚C (200˚F) - Consult factory for correct component selection for temperatures from 71˚C Non-metallic Heads: 49˚C (120˚F) - Consult factory for temperatures above 49˚C (120˚F). Maximum Solids Size 800 microns Inlet Port 3 inch BSPT 3 inch NPT 2-1/2 inch SAE J518 Flange (Non-metallic) 3 inch SAE J518 Flange (Metallic) Discharge Port 1-1/2 inch BSPT 1-1/2 inch NPT 1-1/2 inch SAE Shaft Diameter 50.8 mm (2 inch) Shaft Rotation Reverse (bi-directional) Bearings Tapered roller bearings Oil Capacity 7.5 litres (8 US quarts) Weight Metallic Heads: 226 kg (500 lbs.) Non-metallic Heads: 133 kg (295 lbs.) Calculating Required Power When using a variable frequency drive (VFD) controller, calculate the hp or kW at minimum and maximum pump speed to ensure the correct hp or kW motor is selected. Note that motor manufacturers typically de-rate the service factor to 1.0 when operating with a VFD. Net Positive Suction Head (NPSHr) Self-priming: Each Hydra-Cell pump has different lift capability depending on model size, cam angle, speed, and fluid characteristics. T o ensure that your specific lift characteristics are met, refer to the inlet calculations regarding friction, and acceleration head losses in your Hydra-Cell Installation & Service Manual. Compare those calculations to the NPSHr curves above. Revolutions Per Minute NPSHr (feet of water) NPSHr (meters of water) 0 100 200 300 400 500 600 700 800 900 1000 1.5 2.5 3.5 4.5 100 x rpm + gpm x psi = electric motor hp 63,000 1,460 100 x rpm + l/min x bar = electric motor kW 84,428 511 motor pulley OD = pump pulley OD pump rpm motor rpm Calculating Pulley Size
www.Hydra-Cell.co.uk • 5 G66 Version 4b 07/19 Note: Dimensions are for reference only. Contact factory for certified drawings. G66 Series Representative Drawings G66 Models with BSPT Inlet/Outlet Ports mm (Inches) Metallic pump head models shown. 596.12 (23.47) Ø 50.82 (2.00) 224.41 (8.84) 85.58 (3.37) 553.96 (21.81) 411.99 (16.22) Outlet 1-1/2 BSPT 1-1/2 NPT 468.31 (18.44) Inlet
3 BSPT
3 NPT
250.70 (9.87) 292.86 (11.53) 21.08 (.83) 345.06 (13.59) 224.41 (8.84) 165.10 (6.50) 172.97 (6.81) 12.73 (0.50) 596.12 (23.47) Ø 50.82 (2.00) 224.41 (8.84) 85.58 (3.37) 553.96 (21.81) 411.99 (16.22) Outlet 1-1/2 BSPT 1-1/2 NPT 468.31 (18.44) Inlet 250.70 (9.87) 292.86 (11.53) 21.08 (.83) 345.06 (13.59) 224.41 (8.84) 165.10 (6.50) 172.97 (6.81) 12.73 (0.50)
6 • www.Hydra-Cell.co.uk G66 Version 4b 07/19 G66 Series Representative Drawings G66 Models with SAE Flange Inlet/Outlet Ports mm (Inches) G66 Models with SAE Flange Inlet/Outlet Ports mm (Inches) Note: Dimensions are for reference only. Contact factory for certified drawings. Metallic pump head models shown. Non-metallic pump head models shown. 584.06 (22.99) Ø 50.82 (2.00) 224.41 (8.84) 85.58 (3.37) 553.96 (21.81) 411.99 (16.22) Outlet 1-1/2 SAE 468.31 (18.44) Inlet 2-1/2 SAE 250.70 (9.87) 292.86 (11.53) 21.08 (.83) 345.86 (13.62) 180.85 (7.12) 165.10 (6.50) 172.97 (6.81) 37.13 (1.46) 43.55 (1.71) 12.73 (0.50) 596.12 (23.47) Ø 50.82 (2.00) 12.73 (0.50) 224.41 (8.84) 85.58 (3.37) 553.96 (21.81) 411.99 (16.22) Outlet 1-1/2 SAE 468.31 (18.44) Inlet
3 SAE
250.70 (9.87) 292.86 (11.53) 21.08 (.83) 345.06 (13.59) 224.41 (8.84) 165.10 (6.50) 172.97 (6.81)
www.Hydra-Cell.co.uk • 7 G66 Version 4b 07/19 G66 Series How to Order
Ordering Information
A complete G66 Series Model Number contains 12 digits including 7 customer-specified design and materials options, for example: G66XKCGHFEMH. 1-3 Pump Configuration G66 Shaft-driven (BSPT Ports) D66 Shaft-driven (NPT Ports)
4 Hydraulic End Cam
X Max 248.7 l/min (65.7 gpm) @ 1000 rpm
5 Pump Head Version
K Kel-Cell (NPT or BSPT Ports) E Kel-Cell (SAE Ports)
6 Pump Head Material
C Ductile Iron (Nickel-plated) N Polypropylene (with Hastelloy C followers and follower screws) P Polypropylene (with 316 SST followers and follower screws) S 316L Stainless Steel
7 Diaphragm & O-ring Material
G FKM (used with metallic heads only) H FKM (used with non-metallic heads only) T Buna-N (used with metallic heads only) U Buna-N (used with non-metallic heads only)
8 Valve Seat Material
9 Valve Material
10 Valve Springs
11 Valve Spring Retainers
12 Hydra-Oil
H 15W50 high-temp severe-duty synthetic oil Order Digit Code Description 6 6 X H
WANNER ENGINEERING - WORLD HEADQUARTERS & MANUFACTURING Minneapolis USA t: (612) 332-5681 e: sales@wannereng.com WANNER ENGINEERING Latin American Office t: +55 (11) 4081-7098 e: sales@wannereng.com WANNER PUMPS Shanghai CHINA t: +86-21-6876 3700 e: sales@wannerpumps.com WANNER PUMPS Kowloon HONG KONG t: +852 3428 6534 e: sales@wannerpumps.com WANNER INTERNATIONAL Hampshire UK t: +44 (0) 1252 816847 e: sales@wannerint.com www.hydra-cell.co.uk G66 Version 4b 07/19 Partners in over 70 Countries WANNER