G3NA ETC
Document overview
- Manufacturer or author: Provided By www.digicamel.com(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 9
Technical content
A Wide Range of Models with 5- to 40-A Output Currents and Up to 480-VAC/200-VDC Output Voltages All models feature the same compact dimensions to provide a uniform mounting pitch. Built-in varistor effectively absorb external surges. Operation indicator (red LED) enables monitoring operation. Protective cover for greater safety. Standard models approved by UL/CSA and -UTU models by VDE (TÜV). RCE
Ordering Information
Indicator Rated output load (Applicable output load) Rated input voltage Model Phototriac Yes Yes 5 A at 24 to 240 VAC* (19 t 264 VAC) 5 to 24 VDC G3NA-205B Photocoupler 5a o 0 C (19 to 264 VAC) 100 to 120 VACPhotocou ler 200 to 240 VAC Phototriac 10 A at 24 to 240 VAC* (19 t 264 VAC) 5 to 24 VDC G3NA-210B Photocoupler 0a o 0 C (19 to 264 VAC) 100 to 120 VACo ocou e 200 to 240 VAC
10 A at 200 to 480 VAC*
(180 t 528 VAC) 5 to 24 VDC G3NA-410B0 a 00 o 80 C (180 to 528 VAC) 100 to 240 VAC --- 10 A at 5 to 200 VDC (4 t 220 VDC) 5 to 24 VDC G3NA-D210B0 a5o 0 0 C (4 to 220 VDC) 100 to 240 VAC Phototriac Yes 20 A at 24 to 240 VAC* (19 t 264 VAC) 5 to 24 VDC G3NA-220B Photocoupler 0a o 0 C (19 to 264 VAC) 100 to 120 VACo ocou e 200 to 240 VAC
20 A at 200 to 480 VAC*
(180 t 528 VAC) 5 to 24 VDC G3NA-420B0 a 00 o 80 C (180 to 528 VAC) 100 to 240 VAC Phototriac 40 A at 24 to 240 VAC* (19 t 264 VAC) 5 to 24 VDC G3NA-240B Photocoupler 0a o 0 C (19 to 264 VAC) 100 to 120 VACo ocou e 200 to 240 VAC
40 A at 200 to 480 VAC*
(180 t 528 VAC) 5 to 24 VDC G3NA-440B0 a 00 o 80 C (180 to 528 VAC) 100 to 240 VAC
50 A at 200 to 480 VAC*
(180 to 528 VAC) 5 to 24 VDC G3NA-450B *Loss time increases under 75 VAC. (Refer to page 164.) Note: When ordering a TÜV-approved model, add “-UTU” to the model number as shown below: Example: G3NA-210B-UTU
Accessories (Order Separately) Heat Sink The following heat sinks are thin and can be DIN-track mounted (except Y92B-P250). See Dimensions for details. Model Applicable SSR Y92B-N50 G3NA-205B, G3NA-210B, G3NA-D210B, G3NA-410B, G3NE-205T(L), G3NE-210T(L) Y92B-N100 G3NA-220B, G3NA-420B, G3NE-220T(L) Y92B-N150 G3NA-240B, G3NA-440B Y92B-P250 G3NA-450B Low-cost Models Model Applicable SSR Y92B-A100 G3NA-205B, G3NA-210B, G3NA-D210B, G3NA-220B, G3NA-410B, G3NA-420B Y92B-A150N G3NA-240B, G3NA-440B Y92B-A250 G3NA-440B Mounting Bracket Used to mount the G3NA with a mounting dimension of 56 mm. Model Applicable SSR R99-11 G3NA-240B, G3NA-440B See Dimensions for details. (Refer to page 164.) Specifications Ratings Input (Ambient Temperature: 25°C) Model Rated voltage Operating voltage Impedance Voltage level Must operate voltage Must release voltage G3NA-2 B 5 to 24 VDC 4 to 32 VDC 7 mA max.* 4 VDC max. 1 VDC min. 100 to 120 VAC 75 to 132 VAC 36 kΩ ±20% 75 VAC max. 20 VAC min. 200 to 240 VAC 150 to 264 VAC 72 kΩ ±20% 150 VAC max. 40 VAC min. G3NA-4 B 5 to 24 VDC 4 to 32 VDC 5 mA max.* 4 VDC max. 1 VDC min. G3NA-D210B 100 to 240 VAC 75 to 264 VAC 72 kΩ ±20% 75 VAC max. 20 VAC min. Note: The input impedance is measured at the maximum value of the rated supply voltage (for example, with the model rated at 100 to 120 VAC, the input impedance is measured at 120 VAC). *With constant current input circuit system. The impedance for the G3NA-B-UTU is 15 mA max. **Refer to the Engineering Data for further details. Output Model Applicable load Rated load voltage Load voltage range Load current Inrush current W ith heat sink* W ithout heat sink G3NA-205B 24 to 240 VAC 19 to 264 VAC 0.1 to 5 A 0.1 to 3 A 60 A (60 Hz, 1 cycle) G3NA-210B 0.1 to 10 A 0.1 to 4 A 150 A (60 Hz, 1 cycle) G3NA-410B 200 to 480 VAC 180 to 528 VAC 0.2 to 10 A 0.2 to 4 A G3NA-220B 24 to 240 VAC 19 to 264 VAC 0.1 to 20 A 0.1 to 4 A 220 A (60 Hz, 1 cycle) G3NA-420B 200 to 480 VAC 180 to 528 VAC 0.2 to 20 A 0.2 to 4 A G3NA-240B 24 to 240 VAC 19 to 264 VAC 0.1 to 40 A 0.1 to 6 A 440 A (60 Hz, 1 cycle) G3NA-440B 200 to 480 VAC 180 to 528 VAC 0.2 to 40 A 0.2 to 6 A G3NA-450B 200 to 480 VAC 180 to 528 VAC 0.2 to 50 A 0.2 to 6 A G3NA-D210B 5 to 200 VDC 4 to 220 VDC 0.1 to 10 A 0.1 to 4 A 20 A (10 ms) *When OMRON’ s heat sink (refer to the accessories) or a heat sink of specified size is used.
Item G3NA-205B, -210B, -220B G3NA-240B G3NA-410B, -420B, -440B, -450B G3NA-D210B Operate time 1/2 of load power source cycle + 1 ms max. (DC input) 3/2 of load power source cycle + 1 ms max. (AC input) 1 ms max. (DC input) 30 ms max. (AC input) Release time 1/2 of load power source cycle + 1 ms max. (DC input) 3/2 of load power source cycle + 1 ms max. (AC input) 5 ms max. (DC input) 30 ms max. (AC input) Leakage current 5 mA max. (at 100 VAC) 10 mA max. (at 200 VAC) 10 mA max. (at 200 VAC) 20 mA max. (at 400 VAC) 5 mA max. (at 200 VDC) Insulation resistance 100 MΩ min. (at 500 VDC) Dielectric strength 2,500 VAC, 50/60 Hz for 1 min Vibration resistance Malfunction: 10 to 55 Hz, 1.5-mm double amplitude Shock resistance Malfunction: 1,000 m/s2 Ambient temperature Operating: –30°C to 80°C (with no icing or condensation) Storage: –30°C to 100°C (with no icing or condensation) TÜV R9151660 (EN60950) (except for G3NA-40B) Ambient humidity Operating: 45% to 85% Weight Approx. 60 g Approx. 70 g Approx. 80 g Approx. 70 g
Load Current vs. Ambient Temperature Characteristics G3NA-205B G3NA-210B/410B G3NA-220B/420B Ambient temperature (°C) Ambient temperature (°C) Ambient temperature (°C) Load current (A) Load current (A) Load current (A) With standard heat sink (Y92B-A100 or Y92B- N50) or aluminum plate measuring 75 mm x 75 mm x 13.2 mm (W x H x D) Without heat sink With standard heat sink (Y92B-A100 or Y92B-N50) or aluminum plate measur- ing 150 mm x 150 mm x 13.2 mm (W x H x D) With iron plate measuring 100 x 100 x 0.8 (W x H x D) Without heat sink With standard heat sink (Y92B-A100 or Y92B-N100) or alumi- num plate measuring 200 mm x 200 mm x 13.2 mm (W x H x D) With iron plate measuring 100 x 100 x 0.8 (W x H x D) Without heat sink G3NA-240B G3NA-440B G3NA-D210B Load current (A) Ambient temperature (°C) Load current (A) Ambient temperature (°C) Load current (A) Ambient temperature (°C) With standard heat sink (Y92B-A150N or Y92B-N150) With iron plate measuring 100 x 100 x 0.8 (W x H x D) Without heat sink With Y92B- A250 or heat sink with a ra- diation efficien- cy of 1°C/W. With standard heat sink (Y92B-A150N or Y92B-N150) With iron plate measuring 100 x 100 x 0.8 (W x H x D) Without heat sink With standard heat sink (Y92B-A100 or Y92B-N50) or aluminum plate measur- ing 150 mm x 150 mm x 13.2 mm (W x H x D) With iron plate measuring 100 x 100 x 0.8 (W x H x D) Without heat sink G3NA-450B Load current (A) Ambient temperature (°C) With standard heat sink (Y92B-P250) Without heat sink
Inrush Current Resistivity Non-repetitive (Keep the inrush current to half the rated value if it occurs repetitively.) G3NA-205B G3NA-210B/410B G3NA-220B/420B Inrush current (A. Peak) Energizing time (ms) Inrush current (A. Peak) Energizing time (ms) Inrush current (A. Peak) Energizing time (ms) Ambient temperature (°C) G3NA-240B/440B/450B G3NA-D210B Temperature Characteristics (with Must Operate Voltage and Must Release Voltage) G3NA-2 B AC Input Inrush current (A. Peak) Energizing time (ms) Inrush current (A. Peak) Energizing time (ms) Variation rate (%) Heat Sink Size vs. Load Current G3NA-220BHeat sink size (cm )2 Ambient temperature 80°C Ambient temperature 40°C Aluminum plate 3.2 mm thick Load current (A) Note: The heat sink size refers to the combined area of the sides of the heat sink that radiate heat. For example, when a current of 18 A is allowed to flow through the SSR at 40°C, the graph shows that the heat sink size is about 450 cm2. Therefore, if the heat sink is square, one side of the heat sink must be 15 cm (152 x 2 = 450) or longer.
Note: All units are in millimeters unless otherwise indicated. In the case of surface mounting, a 30% derating of the load current is required. The orientation indicated by the external dimensions is not the correct mounting orientation. When opening mounting holes, refer to the mount- ing hole dimensions. G3NA-205B, G3NA-210B, G3NA-220B, G3NA-410B, G3NA-420B 13.8 Mounting Holes Terminal Arrangement/ Internal Connections (Top View) 47.6±0.2 Two, 4.3-dia. or M4 holes Load Input (-) (+) Load power supply Load 25 max. 27 max. 4.5 dia. Four, M4 x 8 screws 4.5 43 max. 58 max.47.5 44 Operating indicator Mounting Holes Terminal Arrangement/ Internal Connections (Top View) 47.6±0.2 Two, 4.3-dia. or M4 holes Load Input (-) (+) Load power supply Load G3NA-240B, G3NA-440B, G3NA-450B 13.8 25 max. 27 max. 58 min.47.5 44 4.5 dia.Two, M5 x 12 screws Two, M 4 x 8 4.5 43 max. Operating indicator G3NA-D210B 47.6±0.2 Two, 4.3-dia. or M4 holes Mounting Holes Terminal Arrangement/ Internal Connections (Top View) Load Input (-) (+) Load Load power supply 25 max. 27 max. 4.5 dia. Four, M4 x 8 screws 4.5 43 max. 58 max.47.5 44 Operating indicator 13.8 Note: The load can be connected to either the positive or negative side. Mounting HolesHeat Sink Y92B-N50 4.6 dia. Two, M3 holes Two, M4 holes 5.647.6 77 max. 90±0.3 100 max. 35 30.5±0.3 44 max. 30 5 4.56 47 max. Two, 3.2-dia. holes 35±0.2 90±0.4 Two, 4.4-dia. or M4 holes Weight: approx. 200 g 51 max.
4.6 dia. Two, M3 holes Two, M4 holes 35 30.5±0.3 47.6 77 max. 90±0.3 100 max. 5.6 3071 max. 100 max. 4.5 75 max. Two, 3.2-dia. holes 35±0.2 90±0.4 Two, 4.4-dia. or M4 holes Mounting Holes W eight: approx. 400 g 28 13 Y92B-N150 4.6 dia. 47.6 77 max. 5.6 100 max. 100 max. 5 4.5 30100 max. 90±0.3 Two, 3.2-dia. holes 104 max. 35±0.2 90±0.4 Two, 4.4-dia. or M4 holes Mounting Holes W eight: approx. 560 g 56±0.3 1328 Three, holes Mounting Holes Y92B-A100 Y92B-A150 Y92B-A250 Y92B-A100 Y92B-A150N Two, M4 holes 47.6 50±0.1 100 max. Three, M4 holes 47.6 50±0.1 56±0.5 150 max. R2.2 Three, M4 holes R2.2 47.6 50±0.1 56±0.5 250 max. 100.5 max. 80.5 max.1.5 9.6 1.5 Y92B-A250 90±0.1 50±0.1 Four, 4.3-dia. or M4 holes 45.5 max. 90 0.1± 90 0.1± 90 0.1± 70 max. Four, M4 Four, R2.5 130.5 max. 190.5 max. Mounting Holes Four, 4.5 dia. or M4
12.5 4 4.6 Use Mounting Bracket R99-11 so that the G3NA-240B can be mounted with the same pitch as that of the G3N-240B. Y92B-P250 70 max. Four, M4 Four, R2.5 130.5 max. 190.5 max. Mounting Holes Four, 4.5 dia. or M4 Precautions Refer to pages 11 to 19 for general precautions. Load Connection For an AC load, use a power supply rated at 50 or 60 Hz. The maximum operating frequency is 10 Hz. The G3NA has a built-in varistor for overvoltage protection. Zero Cross Function An SSR with a zero cross function operates when an AC load volt- age reaches the zero point or its vicinity. This reduces clicking noises when the load is input, and minimizes the influence of an in- ductive load, such as a lamp, heater, or motor, on the power supply because the inrush current of the load is reduced. This can also minimize the scale of the inrush current protection circuit. Output (load voltage) InputON OFF At a low applied voltage, such as 24 VAC, the load current is not fully supplied. When the Unit is switched ON, the voltage required to power the Unit deprives the output signal of the necessary voltage level and thus creates loss time. The lower the load voltage is, the greater the loss time is. This condition, however, will not create any serious problems. Loss time For a DC or L load, a diode should be connected in parallel the load to absorb the counter electromotive force of the load. SSRInput Load Load power supply
When attaching a heat sink to the G3NA, apply Silicone Grease or equivalent heat conductive grease on the heat sink. (Toshiba Sili- con, Shinetsu Silicon, etc.) Tighten the mounting screws of the heat sink with a torque of 0.78 to 0.98 N /C0083 m. EN5501 1 Measurement of Mains Terminal Disturbance Voltage The G3NA-UTU conforms to EN55011 standards when a capacitor is connected to the load power supply as shown in the following cir- cuit diagram. G3NA-UTU Output Load Input Recommended Capacitor: Nissei Denki’s MKT-series R40 (1 µF) The output terminal side of the G3NA-D210B is connected to a built- in diode for protecting the SSR from damage that may result from reverse connection. The SSR, however, cannot withstand one min- ute or more if the wires are connected in reverse order. Therefore, pay the utmost attention not to make polarity mistakes on the load side. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. K067-E1-1D