FRH080-250UF RFE

Document overview

  • PDF pages: 2

Technical content

Page 1

Radial Leaded PPTC FRH Series

FEATURES

  • Low hold current, Solid state Radial-leaded product ideal for

up to 60V/250V/600V

  • Application: Telecommunication and Data transmitting
  • Operation Current: 0.08A ~ 0.18A
  • Maximum Voltage: 60V/250V/600V
  • Temperature Range: -40°C to 85°C

ELECTRICAL CHARACTERISTICS (23°C)

RoHS

ü

AGENCY RECOGNITION

  • UL (E211981)
  • C-UL (E211981)
  • TÜV (R50004084)
Part Number Hold Current Trip Current Max. Time to Trip Maximum Current Max. Oper. Voltage Max. Int. Voltage Resistance Tolerance
RMIN R1MAX
IH, A IT, A A Sec IMAX, A VMAX, VDC VI-MAX, V OHMS OHMS
FRH080-250UF 0.08 0.16 0.35 4.0 3.0 60 250 14.0 33.0
FRH080-250F 0.08 0.16 0.35 4.0 3.0 60 250 14.0 33.0
FRH110-250UF 0.11 0.22 1.0 2.0 3.0 60 250 5.0 16.0
FRH110-250F 0.11 0.22 1.0 2.0 3.0 60 250 5.0 16.0
FRH120-250UF 0.12 0.24 1.0 2.0 3.0 60 250 6.0 16.0
FRH120-250F 0.12 0.24 1.0 2.0 3.0 60 250 4.0 16.0
FRH145-250UF 0.15 0.29 1.0 2.5 3.0 60 250 3.5 12.0
FRH145-250F 0.15 0.29 1.0 2.5 3.0 60 250 3.0 12.0
FRH180-250UF 0.18 0.65 1.5 10.0 10.0 60 250 0.8 4.0
FRH180-250F 0.18 0.65 1.5 11.0 10.0 60 250 0.8 4.0
FRH150-600F 0.15 0.30 1.0 5.0 3.0 60 600 6.0 22.0
FRH160-600F 0.16 0.32 1.0 7.0 3.0 60 600 4.0 18.0

IH=Hold current-maximum current at which the device will not trip at 23°C still air. IT=Trip current-maximum current at which the device will always trip at 23°C still air. V MAX=Maximum voltage device can withstand without damage at its rated current. VI-MAX=Maximum interrupt voltage device can withstand for short period of time. (Not for long term.) I MAX=Maximum fault current device can withstand without damage at rated voltage (V MAX). Pd=Typical power dissipated from device when in the tripped state in 23°C still air environment. R MIN=Minimum device resistance at 23°C. R1MAX=Maximum device resistance at 23°C, 1 hour after tripping. Physical specifications:

Lead material: FRH080-250~FRH180-250 Tin plated copper, 22 AWG. FRH150-600~FRH160-600 Tin plated copper, 22 AWG. Soldering characteristics: MIL-STD-202, Method 208E. Insulating coating: Flame retardant epoxy, meet UL-94V-0 requirement.

FRH PRODUCT DIMENSIONS (MILLIMETERS)

NOTE: All FRH products are designed to assist equipment to pass ITU, UL1950 or GR1089 specification.

Part A B C D E
Number Maximum Maximum Typical Minimum Maximum
FRH080-250UF 4.8 9.1 5 4.7 3.8
FRH080-250F 5.3 9.6 5 4.7 4.6
FRH110-250UF 5.3 9.4 5 4.7 3.8
FRH110-250F 5.8 9.9 5 4.7 4.6
FRH120-250UF 6.0 10.0 5 4.7 3.8
FRH120-250F 6.5 11.0 5 4.7 4.6
FRH145-250UF 6.0 10.0 5 4.7 3.8
FRH145-250F 6.5 11.0 5 4.7 4.6
FRH180-250UF 10.4 12.6 5 4.7 3.8
FRH180-250F 10.9 13.6 5 4.7 4.6
FRH150-600F 13.5 12.6 5 4.7 6
FRH160-600F 16.0 12.6 5 4.7 6

Figure 1

PDF page 1 diagram

Lead Size: 22AWG (0.65mm)

Figure 2

PDF page 1 diagram

Lead Size: 22AWG (0.65mm)

CAUTION: FRH devices are not intended for continous use of Line Voltage such as 120 VAC\`600VAC and above.

C5EB08

RFE International • Tel:(949) 833-1988 • Fax:(949) 833-1788 • E-Mail Sales@rfeinc.com

REV 2007.03.1

Page 2

Radial Leaded PPTC

RoHS

ü

FRH Series

THERMAL DERATING CURVE

PDF page 2 diagram

TYPICAL TIME-TO-TRIP AT 23°C

PDF page 2 diagram

A= FRH080(U)-250 B= FRH110(U)-250 C= FRH120(U)-250 D= FRH145(U)-250 E= FRH180(U)-250 F= FRH150-600 G= FRH160-600

CAUTION: FRH devices are not intended for continous use of Line Voltage such as 120 VAC\`600VAC and above.

NOTE: All Specification subject to change without notice.

C5EB08

RFE International • Tel:(949) 833-1988 • Fax:(949) 833-1788 • E-Mail Sales@rfeinc.com