EI0601NACS ETC2
Document overview
- Manufacturer or author: Provided By www.digicamel.com(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 2
Technical content
Specifications are subject to change without notice (20.08.01) 1 Housing Rated operating distance Ordering no. diameter (S n) NAMUR Ø 6.5 mm 1 mm 1) EI 0601 NACS M8 1 mm 1) EI 0801 NACS 1) For flush mounting in metal M8 2 mm 2) EI 0802 NACS 2) For non-flush mounting in metal
- Stainless steel housing, cylindrical
- Diameter: Ø 6.5, M8
- Short versions
- Sensing distance: 1 to 2 mm
- Output: NAMUR (DIN 19234)
- P rotection: Reverse polarity
- 2 m cable Proximity Sensors Inductive Stainless Steel Housing Types EI, Ø 6.5, M8, NAMUR Proximity switch in Ø 6.5 and M8 housings. Made in accor- dance with NAMUR DIN 19 234. Short version in standard stainless steel housing. Ampli- fier relay SD ... is available. Type Housing diameter (mm) Rated operating dist. (mm) Output type Housing material Type Selection Rated operational volt. (Ue) 8.2 VDC (UB)7 to 9 VDC (6 to 35 VDC, all specifica- tions not observed in extended supply range) Self-inductance Max. 500 µH Self-capacitance Max. 120 nF Current consumption (Io) Activated: ≤1 mA Not activated: ≥ 2.2 mA Max.: 9.35 mA Protection Reverse polarity Transient voltage ≤ 1 kV/0.5 J (prepared) Frequency of operating cycles (f) EI 0601 2000 Hz EI 0801 2000 Hz EI 0802 1500 Hz Assured operating dist. (Sa)0 ≤ Sa ≤ 0.81 x Sn Repeat accuracy (R) ≤ 5% Hysteresis (H) (Differential travel) Dependent on amplifier relay Product Description Ordering Key Specifications Effective operating dist. (Sr)0 . 9 x Sn ≤ Sr ≤ 1.1 x Sn Usab le operating dist. (Su)0 . 9 x Sr ≤ Su ≤ 1.1 x SrZ Ambient temperature Operating -25° to +70°C (-13° to +158°F) Storage -30° to +80°C (-22° to +176°F) Degree of protection IP 67 Housing material Body Stainless steel (1.4301) Front Thermoplastic polyester Back Black PVC Cable EI 06 2 m, 2 x 0.14 mm2 EI 08 2 m, 2 x 0.14 mm2 grey PVC, oil proof Weight (cable included) EI 06 30 g EI 08 50 g Tightening torque EI 08 3.0 Nm (x)
7.0 Nm (y)
Refer to "Terms Used" Technical information. Approvals UL, CSA CE-marking Yes EI 0601 NAC S
2 Specifications are subject to change without notice (20.08.01) Dimensions EI, Ø 6.5, M8, NAMUR EI 0601 EI 08 Type A B C D E F G H I SW K Ø mm mm mm mm mm mm mm mm mm Ø mm EI 0801 M8 x 1 6.7 51 2000 0 35 16 Ø 6.5 4 13 3 EI 0802 M8 x 1 6.7 54 2000 3 35 16 Ø 6.5 4 13 3 > SD 110/210. > SD 170/270. Refer to Technical informa- tion. NAMUR, Amplifier Relays Installation Hints Relief of cable strain Protection of the sensing face Switch mounted on mobile carrierTo avoid interference from inductive voltage/ current peaks, separate the prox. switch pow- er cables from any other power cables, e.g. motor, contactor or solenoid cables Incorrect Correct The cable should not be pulled A proximity switch should not serve as mechanical stop Any repetitive flexing of the cable should be avoided Wiring Diagram BN R BU 1 K 8.2 V