DS401 BRIDGELUX

Document overview

  • PDF pages: 24

Technical content

Page 1

PDF page 1 diagram

Page 2

PDF page 2 diagram

V Series™ HD LED array product, an ultra-high lumen density COB product line, is designed for high intensity spotlights used in commercial and retail settings. V Series HD arrays offer industry leading color over angle uniformity, and replace ceramic metal halide lamps by providing equal or greater center beam candle power at lower power and at greater lifetimes. Their tight beam control and exceptional quality of light is well suited for demanding directional spot applications.

The V6 HD LED array is available in a variety of CCT and CRI combinations providing substantial design flexibility and energy efficiencies.

Lighting system designs incorporating these LED arrays deliver increased system level efficacy and longer service life. Typical applications include, but are not limited to, commercial and residential down lights, accent, spot and track lights.

Bridgelux Décor Series™ is our state of the art color line designed specifically for premium applications, producing unmatched LED light quality with brilliant color-rendering options and offer pleasing and inspiring lighting palettes. Bridgelux Décor Series color points are available on Vero® SE Series, Vero® Series, V Series™ and V Series™ HD.

Décor Series Class A is based on human response testing, providing color points with a combined GAI and CRI metric.

Décor Series™ Ultra products provide a high CRI of 97 and a minimum R9 value of 91, which emphasizes the reds and color tones to which the human eye is most receptive - perfect for the most luxurious retail shops and world renowned museums. Décor Series Ultra is designed as a replacement for halogen.

Décor Series™ Showcase is the optimal solution for replacing ceramic metal halide lamps, incorporating the same pure white light with enhanced spectrum coverage and higher efficacy.

Features

  • Efficacy of 125 lm/W typical, 3000K 80 CRI
  • Compact high flux density light source
  • Uniform high quality illumination
  • Minimum 80, 90 and 95 CRI options
  • Streamlined thermal path
  • ENERGY STAR® / ANSI compliant color binning structure with 3 SDCM options
  • More energy efficient than incandescent, halogen and fluorescent lamps
  • Low voltage DC operation
  • Instant light with unlimited dimming
  • Vf bin code backside marking

Benefits

  • Enhanced optical control
  • Clean white light without pixelation
  • High quality true color reproduction
  • Significantly reduced thermal resistance and increased operating temperatures
  • Uniform consistent white light
  • Lower operating costs
  • Easy to use with daylight and motion detectors to enable increased energy savings
  • Reduced maintenance costs
  • Environmentally friendly, no disposal issue

Page 3

PDF page 3 diagram
PDF page 3 diagram

Page 4

PDF page 4 diagram

Bridgelux arrays are fully engineered devices that provide consistent thermal and optical performance on an engineered mechanical platform. The V Series HD arrays are the most compact chip-on-board devices across all of

Designed to comply with global

Bridgelux’s LED array products. The arrays incorporate several features to simplify design integration and assembly. Please visit www.bridgelux.com for more information on the V Series HD family of products.

Polarity symbols

safety standards for creepage and clearance distances

PDF page 4 diagram

Fully engineered substrate for consistent thermal, mechanical and optical properties

White ring around LES

Yellow phosphor Light Emitting Surface (LES)

Case Temperature (Tc) Measurement Point

Solder Pads

Note: Part number and lot codes are scribed on back of array

PDF page 4 diagram

Page 5

PDF page 5 diagram

The following product configurations are available:

Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C)

Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 T = 25ºC c (lm) Minimum Pulsed Flux6,7 T = 25ºC c (lm) Typical V f (V) Typical Power (W) Typical Efficacy (lm/W)
BXRH-27E1000-B-73 2700 80 350 1508 1297 36.4 12.7 118
BXRH-27E1000-G-73 2700 80 700 1508 1297 18.2 12.7 118
BXRH-27G1000-B-73 2700 90 350 1254 1078 36.4 12.7 98
BXRH-27G1000-G-73 2700 90 700 1254 1078 18.2 12.7 98
BXRH-27G10H0-B-73 2700 90 350 1385 1191 36.4 12.7 109
BXRH-27G10H0-G-73 2700 90 700 1385 1191 18.2 12.7 109
BXRH-27H1000-B-73 2700 97 350 1111 955 36.4 12.7 87
BXRH-27H1000-G-73 2700 97 700 1111 955 18.2 12.7 87
BXRH-30E1000-B-73 3000 80 350 1587 1365 36.4 12.7 125
BXRH-30E1000-G-73 3000 80 700 1587 1365 18.2 12.7 125
BXRH-30G1000-B-73 3000 90 350 1333 1146 36.4 12.7 105
BXRH-30G1000-G-73 3000 90 700 1333 1146 18.2 12.7 105
BXRH-30G10H0-B-73 3000 90 350 1455 1251 36.4 12.7 105
BXRH-30G10H0-G-73 3000 90 700 1455 1251 18.2 12.7 105
BXRH-30G100C-B-73 3000 90 350 1222 1051 36.4 12.7 96
BXRH-30G100C-G-73 3000 90 700 1222 1051 18.2 12.7 96
BXRH-30H1000-B-73 3000 97 350 1174 1010 36.4 12.7 92
BXRH-30H1000-G-73 3000 97 700 1174 1010 18.2 12.7 92
BXRH-35A1001-B-738,9 3500 93 350 1333 1146 36.4 12.7 105
BXRH-35A1001-G-738,9 3500 93 700 1333 1146 18.2 12.7 105
BXRH-35E1000-B-73 3500 80 350 1635 1406 36.4 12.7 128
BXRH-35E1000-G-73 3500 80 700 1635 1406 18.2 12.7 128
BXRH-35G1000-B-73 3500 90 350 1365 1174 36.4 12.7 107
BXRH-35G1000-G-73 3500 90 700 1365 1174 18.2 12.7 107
BXRH-35H1000-B-73 3500 97 350 1339 1151 36.4 12.7 105
BXRH-35H1000-G-73 3500 97 700 1339 1151 18.2 12.7 105
BXRH-40E1000-B-73 4000 80 350 1650 1419 36.4 12.7 130
BXRH-40E1000-G-73 4000 80 700 1650 1419 18.2 12.7 130
BXRH-40G1000-B-73 4000 90 350 1397 1201 36.4 12.7 110
BXRH-40G1000-G-73 4000 90 700 1397 1201 18.2 12.7 110
BXRH-40H1000-B-73 4000 97 350 1374 1182 36.4 12.7 108
BXRH-40H1000-G-73 4000 97 700 1374 1182 18.2 12.7 108

Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. 2. CRI values are typical for Decor Series Ultra and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 91. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance.

  1. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance.

Page 6

PDF page 6 diagram

Table 2: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5

Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 T = 85ºC c(lm) Minimum DC Flux6 T = 85ºC c(lm) Typical V (V) f Typical Power (W) Typical Efficacy (lm/W)
BXRH-27E1000-B-73 2700 80 350 1327 1141 35.4 12.4 107
BXRH-27E1000-G-73 2700 80 700 1327 1141 17.7 12.4 107
BXRH-27G1000-B-73 2700 90 350 1103 949 35.4 12.4 89
BXRH-27G1000-G-73 2700 90 700 1103 949 17.7 12.4 89
BXRH-27G10H0-B-7x 2700 90 350 1219 1048 35.4 12.4 98
BXRH-27G10H0-G-7x 2700 90 700 1219 1048 17.7 12.4 98
BXRH-27H1000-B-73 2700 97 350 978 841 35.4 12.4 79
BXRH-27H1000-G-73 2700 97 700 978 841 17.7 12.4 79
BXRH-30E1000-B-73 3000 80 350 1397 1201 35.4 12.4 113
BXRH-30E1000-G-73 3000 80 700 1397 1201 17.7 12.4 113
BXRH-30G1000-B-73 3000 90 350 1173 1009 35.4 12.4 95
BXRH-30G1000-G-73 3000 90 700 1173 1009 17.7 12.4 95
BXRH-30G10H0-B-73 3000 90 350 1280 1101 35.4 12.4 103
BXRH-30G10H0-G-73 3000 90 700 1280 1101 17.7 12.4 103
BXRH-30G100C-B-73 3000 90 350 1075 925 35.4 12.4 87
BXRH-30G100C-G-73 3000 90 700 1075 925 17.7 12.4 87
BXRH-30H1000-B-73 3000 97 350 1033 889 35.4 12.4 83
BXRH-30H1000-G-73 3000 97 700 1033 889 17.7 12.4 83
BXRH-35A1001-B-738,9 3500 93 350 1173 1009 35.4 12.4 95
BXRH-35A1001-G-738,9 3500 93 700 1173 1009 17.7 12.4 95
BXRH-35E1000-B-73 3500 80 350 1438 1237 35.4 12.4 116
BXRH-35E1000-G-73 3500 80 700 1438 1237 17.7 12.4 116
BXRH-35G1000-B-73 3500 90 350 1201 1033 35.4 12.4 97
BXRH-35G1000-G-73 3500 90 700 1201 1033 17.7 12.4 97
BXRH-35H1000-B-73 3500 97 350 1178 1013 35.4 12.4 95
BXRH-35H1000-G-73 3500 97 700 1178 1013 17.7 12.4 95
BXRH-40E1000-B-73 4000 80 350 1452 1249 35.4 12.4 117
BXRH-40E1000-G-73 4000 80 700 1452 1249 17.7 12.4 117
BXRH-40G1000-B-73 4000 90 350 1229 1057 35.4 12.4 99
BXRH-40G1000-G-73 4000 90 700 1229 1057 17.7 12.4 99
BXRH-40H1000-B-73 4000 97 350 1209 1040 35.4 12.4 98
BXRH-40H1000-G-73 4000 97 700 1209 1040 17.7 12.4 98

Notes for Table 2: 1. Nominal CCT as defined by ANSI C78.377-2011. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI prod­ ucts is 91. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface

material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.

  1. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance.

Page 7

PDF page 7 diagram

The European Product Registry for Energy Labeling (EPREL) is defined in the EU Regulation 2017/1369 to provide import­

ant energy efficiency information to consumers. Together with Energy Labeling Regulation ELR (EU) 2019/2015 which was

amended by regulation (EU) 2021/340 for energy labelling of light sources, manufacturers are required to declare an ener­ gy class based on key technical specifications from each of their product and register it in an open data base managed by EPREL It is now a legal requirement for a vendor of light sources to upload information about their products into the EPREL

database before placing these products on the market in the EU.

Table 3 below provides a list of part numbers that are in compliance with ELR and are currently listed in the EPREL data­

base.

At Bridgelux, we are fully committed to supplying products that are compliant with pertinent laws, rules, and obligation

imposed by relevant government bodies including the European Energy Labeling regulation. Customers can use these

Table 3: Part numbers registered in European Product Registry for Energy Labeling

PART NUMBER1 CCT (K) CRI Current2 (mA) Vf (V) Useful flux3 (Φuse) at 85C (lm) Pow­ er (W) Efficacy (lm/W) Energy efficiency class4 Regis­ tration No URL to Product Information Sheet in EPREL Database
BXRH-27E1000-B-73 2700 80 360 36.8 1416 13.3 107 F 875781 https://eprel.ec.europa.eu/qr/875781
BXRH-27E1000-G-73 2700 80 740 17.9 1416 13.3 107 F 875785 https://eprel.ec.europa.eu/qr/875785
BXRH-27G1000-B-73 2700 90 270 36.0 926 9.7 95 F 875803 https://eprel.ec.europa.eu/qr/875803
BXRH-27G1000-G-73 2700 90 560 17.4 926 9.7 95 F 875807 https://eprel.ec.europa.eu/qr/875807
BXRH-27H1000-B-73 2700 95 220 36.2 698 8.0 88 G 875837 https://eprel.ec.europa.eu/qr/875837
BXRH-27H1000-G-73 2700 95 460 17.3 698 8.0 88 G 875841 https://eprel.ec.europa.eu/qr/875841
BXRH-30E1000-B-73 3000 80 410 36.6 1634 15.0 109 F 875867 https://eprel.ec.europa.eu/qr/875867
BXRH-30E1000-G-73 3000 80 830 18.1 1634 15.0 109 F 875871 https://eprel.ec.europa.eu/qr/875871
BXRH-30G1000-B-73 3000 90 320 35.9 1123 11.5 98 F 875899 https://eprel.ec.europa.eu/qr/875899
BXRH-30G1000-G-73 3000 90 650 17.7 1123 11.5 98 F 875903 https://eprel.ec.europa.eu/qr/875903
BXRH-30G100C-B-73 3000 90 260 34.0 836 8.8 95 F 875911 https://eprel.ec.europa.eu/qr/875911
BXRH-30G100C-G-73 3000 90 530 16.7 836 8.8 95 F 875915 https://eprel.ec.europa.eu/qr/875915
BXRH-30H1000-B-73 3000 95 250 35.4 804 8.8 91 G 875946 https://eprel.ec.europa.eu/qr/875946
BXRH-30H1000-G-73 3000 95 520 17.0 804 8.8 91 G 875950 https://eprel.ec.europa.eu/qr/875950
BXRH-35A1001-B-73 3500 90 320 35.9 1123 11.5 98 F 875969 https://eprel.ec.europa.eu/qr/875969
BXRH-35A1001-G-73 3500 90 650 17.7 1123 11.5 98 F 875971 https://eprel.ec.europa.eu/qr/875971
BXRH-35G1000-B-73 3500 90 330 34.8 1150 11.5 100 F 876004 https://eprel.ec.europa.eu/qr/876004
BXRH-35G1000-G-73 3500 90 680 16.9 1150 11.5 100 F 876008 https://eprel.ec.europa.eu/qr/876008
BXRH-40E1000-B-73 4000 80 450 37.3 1837 16.8 109 F 876046 https://eprel.ec.europa.eu/qr/876046
BXRH-40E1000-G-73 4000 80 910 18.5 1837 16.8 109 F 876050 https://eprel.ec.europa.eu/qr/876050
BXRH-40G1000-B-73 4000 90 350 35.4 1245 12.4 101 F 876068 https://eprel.ec.europa.eu/qr/876068
BXRH-40G1000-G-73 4000 90 720 17.2 1245 12.4 101 F 876072 https://eprel.ec.europa.eu/qr/876072

Notes for Table 3: 1. All device listed here must be disposed as e-waste upon its end of life according to local country guideline in each country. 2. For information on performance values at alternative drive conditions. please refer to the Product Selection Guide, Absolute Maximum Rating Table and Performance Curves in this data sheet. 3. For a definition of useful luminous flux (ΦΦuse), please see the ELR regulations at https://tinyurl.com/4b6zvt4m. 4. EPREL requires an arrow symbol containing the letter of the energy efficiency class to be displayed. on technical promotional material. Refer to this energy efficiency class column for specific energy efficiency class on each part number.

Page 8

PDF page 8 diagram

V Series HD LED arrays are tested to the specifications shown using the nominal drive currents in Table 1. V Series HD LED arrays may also be driven at other drive currents dependent on specific application design requirements. The performance at any drive current can be derived from the current vs. voltage characteristics shown in Figure 1 & 2 and the flux vs. current characteristics shown in Figure 3 & 4. The performance at commonly used drive currents is summarized in Table 4.

Table 4: Product Performance at Commonly Used Drive Currents

Part Number CRI Drive Current1 (mA) Typical V f T = 25ºC c (V) Typical Power T = 25ºC c (W) Typical Flux2 T = 25ºC c (lm) Typical DC Flux3 T = 85ºC c (lm) Typical Efficacy T = 25ºC c (lm/W)
BXRH-27E1000-B-73 80 175 34.2 6.0 813 715 136
250 35.2 8.8 1123 988 128
350 36.4 12.7 1508 1327 118
440 37.3 16.4 1833 1613 112
480 37.7 18.1 1970 1734 109
BXRH-27E1000-G-73 80 350 16.9 5.9 813 715 137
500 17.4 8.7 1123 988 129
700 18.2 12.7 1508 1327 118
880 18.5 16.3 1833 1613 113
960 18.7 17.9 1970 1734 110
BXRH-27G1000-B-73 90 175 34.2 6.0 676 595 113
250 35.2 8.8 934 822 106
350 36.4 12.7 1254 1103 98
440 37.3 16.4 1524 1341 93
480 37.7 18.1 1638 1442 90
BXRH-27G1000-G-73 90 350 16.9 5.9 676 595 114
500 17.4 8.7 934 822 107
700 18.2 12.7 1254 1103 98
880 18.5 16.3 1524 1341 94
960 18.7 17.9 1638 1442 91
BXRH-27G10H0-B-73 90 175 34.2 6.0 747 672 125
250 35.2 8.8 1030 927 117
350 36.4 12.7 1385 1246 109
440 37.3 16.4 1684 1516 103
480 37.7 18.1 1810 1629 100
BXRH-27G10H0-G-73 90 350 16.9 5.9 747 672 126
500 17.4 8.7 1030 927 118
700 18.2 12.7 1385 1246 109
880 18.5 16.3 1684 1516 103
960 18.7 18.0 1810 1629 101
BXRH-27H1000-B-73 97 (typcal) 175 34.2 6.0 599 527 100
250 35.2 8.8 827 728 94
350 36.4 12.7 1111 978 87
440 37.3 16.4 1351 1189 82
480 37.7 18.1 1452 1277 80
BXRH-27H1000-G-73 97 (typcal) 350 16.9 5.9 599 527 101
500 17.4 8.7 827 728 95
700 18.2 12.7 1111 978 87
880 18.5 16.3 1351 1189 83
960 18.7 17.9 1452 1277 81

Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Page 9

PDF page 9 diagram

Table 4: Product Performance at Commonly Used Drive Currents (Continued)

Part Number CRI Drive Current1 (mA) Typical V f T = 25ºC c (V) Typical Power T = 25ºC c (W) Typical Flux2 T = 25ºC c (lm) Typical DC Flux3 T = 85ºC c (lm) Typical Efficacy T = 25ºC c (lm/W)
BXRH-30E1000-B-73 80 175 34.2 6.0 855 753 143
250 35.2 8.8 1182 1040 134
350 36.4 12.7 1587 1397 125
440 37.3 16.4 1930 1698 117
480 37.7 18.1 2074 1825 114
BXRH-30E1000-G-73 80 350 16.9 5.9 855 753 144
500 17.4 8.7 1182 1040 136
700 18.2 12.7 1587 1397 125
880 18.5 16.3 1930 1698 119
960 18.7 17.9 2074 1825 116
BXRH-30G1000-B-73 90 175 34.2 6.0 718 632 120
250 35.2 8.8 993 874 113
350 36.4 12.7 1333 1173 105
440 37.3 16.4 1621 1426 99
480 37.7 18.1 1742 1533 96
BXRH-30G1000-G-73 90 350 16.9 5.9 718 632 121
500 17.4 8.7 993 874 114
700 18.2 12.7 1333 1173 105
880 18.5 16.3 1621 1426 100
960 18.7 17.9 1742 1533 97
BXRH-30G10H0-B-73 90 175 34.2 6.0 784 706 131
250 35.2 8.8 1082 974 123
350 36.4 12.7 1455 1309 114
440 37.3 16.4 1769 1592 108
480 37.7 18.1 1901 1711 105
BXRH-30G10H0-G-73 90 350 16.9 5.9 784 706 133
500 17.4 8.7 1082 974 124
700 18.2 12.7 1455 1309 114
880 18.5 16.3 1769 1592 109
960 18.7 18.0 1901 1711 106
BXRH-30G100C-B-73 90 175 34.2 6.0 659 580 110
250 35.2 8.8 910 801 103
350 36.4 12.7 1222 1075 96
440 37.3 16.4 1486 1308 90
480 37.7 18.1 1597 1405 88
BXRH-30G100C-G-73 90 350 16.9 5.9 659 580 111
500 17.4 8.7 910 801 105
700 18.2 12.7 1222 1075 96
880 18.5 16.3 1486 1308 91
960 18.7 17.9 1597 1405 89
BXRH-30H1000-B-73 97 (typcal) 175 34.2 6.0 633 557 106
250 35.2 8.8 874 770 99
350 36.4 12.7 1174 1033 92
440 37.3 16.4 1428 1257 87
480 37.7 18.1 1535 1350 85

Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Page 10

PDF page 10 diagram

Table 4: Product Performance at Commonly Used Drive Currents (Continued)

Part Number CRI Drive Current1 (mA) Typical V f T = 25ºC c (V) Typical Power T = 25ºC c (W) Typical Flux2 T = 25ºC c (lm) Typical DC Flux3 T = 85ºC c (lm) Typical Efficacy T = 25ºC c (lm/W)
BXRH-30H1000-G-73 97 (typcal) 350 16.9 5.9 633 557 107
500 17.4 8.7 874 770 100
700 18.2 12.7 1174 1033 92
880 18.5 16.3 1428 1257 88
960 18.7 17.9 1535 1350 86
BXRH-35A1001-B-73 93 (typcal) 175 34.2 6.0 718 632 120
250 35.2 8.8 993 874 113
350 36.4 12.7 1333 1173 105
440 37.3 16.4 1621 1426 99
480 37.7 18.1 1742 1533 96
BXRH-35A1001-G-73 93 (typcal) 350 16.9 5.9 718 632 121
500 17.4 8.7 993 874 114
700 18.2 12.7 1333 1173 105
880 18.5 16.3 1621 1426 100
960 18.7 17.9 1742 1533 97
BXRH-35E1000-B-73 80 175 34.2 6.0 881 775 147
250 35.2 8.8 1217 1071 138
350 36.4 12.7 1635 1438 128
440 37.3 16.4 1988 1749 121
480 37.7 18.1 2136 1880 118
BXRH-35E1000-G-73 80 350 17.1 6.0 881 775 147
500 17.6 8.8 1217 1071 138
700 18.2 12.7 1635 1438 128
880 18.7 16.4 1988 1749 121
960 18.9 18.1 2136 1880 118
BXRH-35G1000-B-73 90 175 34.2 5.9 736 647 123
250 35.2 8.8 1016 894 116
350 36.4 12.7 1365 1201 107
440 37.3 16.4 1659 1460 101
480 37.7 18.1 1783 1569 98
BXRH-35G1000-G-73 90 350 16.9 6.0 736 647 124
500 17.4 8.7 1016 894 117
700 18.2 12.7 1365 1201 107
880 18.5 16.3 1659 1460 102
960 18.7 17.9 1783 1569 99
BXRH-35H1000-B-73 97 (typcal) 175 34.2 6.0 722 650 121
250 35.2 8.8 996 896 113
350 36.4 12.7 1339 1205 105
440 37.3 16.4 1628 1465 99
480 37.7 18.1 1750 1575 97
BXRH-35H1000-G-73 97 (typcal) 350 16.9 5.9 722 650 122
500 17.4 8.7 996 896 114
700 18.2 12.7 1339 1205 105
880 18.5 16.3 1628 1465 100
960 18.7 18.0 1750 1575 97

Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Page 11

PDF page 11 diagram

Table 4: Product Performance at Commonly Used Drive Currents (Continued)

Part Number CRI Drive Current1 (mA) Typical V f T = 25ºC c (V) Typical Power T = 25ºC c (W) Typical Flux2 T = 25ºC c (lm) Typical DC Flux3 T = 85ºC c (lm) Typical Efficacy T = 25ºC c (lm/W)
BXRH-40E1000-B-73 80 175 34.2 6.0 889 783 149
250 35.2 8.8 1229 1082 140
350 36.4 12.7 1650 1452 130
440 37.3 16.4 2007 1766 122
480 37.7 18.1 2157 1898 119
BXRH-40E1000-G-73 80 350 16.9 5.9 889 783 150
500 17.4 8.7 1229 1082 141
700 18.2 12.7 1650 1452 130
880 18.5 16.3 2007 1766 123
960 18.7 17.9 2157 1898 120

Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Page 12

PDF page 12 diagram

Table 5: Electrical Characteristics

Part Number Drive Current (mA) Forward Voltage Pulsed, T = 25ºC (V) 1, 2, 3, 8 c Typical Coefficient of Forward Voltage4 ∆V/∆T f c (mV/ºC) Typical Thermal Resistance Junction to Case5,6 R (ºC/W) j-c Driver Selection Voltages7 (V)
Minimum Typical Maximum
V Min. f Hot T = 105ºC c (V) V Max. f Cold T = -40ºC c (V)
BXRH-xxx100x-B-73 350 34.1 36.4 39.1 -16.2 0.36 32.8 40.2
480 35.2 37.7 40.4 -16.2 0.39 33.9 41.5
BXRH-xxx100x-G-73 700 17.0 18.2 19.6 -8.1 0.36 16.4 20.1
960 17.6 18.7 20.2 -8.1 0.39 16.9 20.8

Notes for Table 5: 1. Parts are tested in pulsed conditions, Tc = 25°C. Pulse width is 10ms. 2. Voltage minimum and maximum are provided for reference only and are not a guarantee of performance. 3. Bridgelux maintains a tester tolerance of ± 0.10V on forward voltage measurements. 4. Typical coefficient of forward voltage tolerance is ± 0.1mV for nominal current. 5. Thermal resistance values are based from test data of a 3000K 80 CRI product. 6. Thermal resistance value was calculated using total electrical input power; optical power was not subtracted from input power. The thermal interface material used during testing is not included in the thermal resistance value.

  1. Vf min hot and max cold values are provided as reference only and are not guaranteed by test. These values are provided to aid in driver design and selection over the operating range of the product. 8. This product has been designed and manufactured per IEC 62031:2018. This product has passed dielectric withstand voltage testing at 500 V. The working voltage designated for the insulation is 50V d.c. The maximum allowable voltage across the array must be determined in the end product application.

Page 13

PDF page 13 diagram

Table 6: Eye Safety Risk Group (RG) Classifications

Part Number Drive Current3 (mA) CCT1,3
2700K/3000K 4000K2
BXRH-xxx100x-B-73 350 RG1 RG2
480 RG1 RG2
BXRH-xxx100x-G-73 700 RG1 RG2
960 RG1 RG2

Notes for Table 6: 1. Eye safety classification for the use of Bridgelux V Series HD LED arrays is in accordance with specification IEC/TR 62778: Application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires. 2. For products classified as RG2 at 4000K, Ethr= 1760 lx. 3. Please contact your Bridgelux sales representative for Ethr values at specific drive currents and CCTs not listed.

Page 14

PDF page 14 diagram

Table 7: Maximum Ratings

Parameter Maximum Rating
LED Junction Temperature (T) j 125°C
Storage Temperature -40°C to +105°C
Operating Case Temperature1 (T) c 105°C
Soldering Temperature2 300°C or lower for a maximum of 6 seconds
BXRH-xxx100x-B-73 BXRH-xxx100x-G-73
Maximum Drive Current3 480mA 960mA
Maximum Peak Pulsed Drive Current4 680mA 1360mA
Maximum Reverse Voltage5 -60V -35V

Notes for Table 7: 1. For IEC 62717 requirement, please consult your Bridgelux sales representative. 2. Refer to Bridgelux Application Note AN101: Handling and Assembly of Bridgelux V Series LED Arrays. 3. Arrays may be driven at higher currents however lumen maintenance may be reduced, and product warranty will be void. 4. Bridgelux recommends a maximum duty cycle of 10% and pulse width of 20 ms when operating LED Arrays at maximum peak pulsed current specified. Maximum peak pulsed currents indicate values where LED Arrays can be driven without catastrophic failures. 5. Light emitting diodes are not designed to be driven in reverse voltage and will not produce light under this condition. Maximum rating

provided for reference only.

Page 15

PDF page 15 diagram

Figure 1: Drive Current vs. Voltage V6B HD2

PDF page 15 diagram

Figure 3: Typical Relative Flux vs. Current V6B HD1,2

PDF page 15 diagram

Figure 5: Typical DC Flux vs. Case Temperature3

PDF page 15 diagram

Figure 2: Drive Current vs. Voltage V6G HD2

PDF page 15 diagram

Figure 4: Typical Relative Flux vs. Current V6G HD1,2

PDF page 15 diagram
  1. Bridgelux does not recommend driving high power LEDs at low currents. Doing so may produce unpredictable results. Pulse width modulation (PWM) is

recommended for dimming effects.

  1. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 3. Characteristics shown for warm white based on 3000K and 80 CRI. Characteristics shown for neutral white based on 4000K and 80 CRI. Characteristics

shown for warm white includes Decor Series Class A

Page 16

PDF page 16 diagram

Figure 6: Typical DC ccx Shift vs. Case Temperature4

PDF page 16 diagram

Figure 8: 2700K, 97 CRI Color Shift vs. Case Temperature1

PDF page 16 diagram

Figure 10: 3500K Class A Color Shift vs. Case Temperature1

PDF page 16 diagram

1. Measurements made under DC test conditions at the nominal drive current.

2. Typical color shift is shown with a tolerance of ±0.002. 3. Characteristics shown for Decor Series Showcase products, BXRH-30G100C-x-73

Figure 7: Typical DC ccy Shift vs. Case Temperature4

PDF page 16 diagram

Figure 9: 3000K, 97 CRI Color Shift vs. Case Temperature1

PDF page 16 diagram

Figure 11: 3000K, 90 CRI Color Shift vs. Case Temperature3

PDF page 16 diagram
  1. For other color SKUs, the shift in color will vary. Please contact your Bridgelux Sales Representative for more information.

Page 17

PDF page 17 diagram

Figure 12: Typical Spatial Radiation Pattern

PDF page 17 diagram

Notes for Figure 12: 1. Typical viewing angle is 120⁰. 2. The viewing angle is defined as the off axis angle from the centerline where intensity is ½ of the peak value.

Figure 13: Typical Polar Radiation Pattern

PDF page 17 diagram

Page 18

PDF page 18 diagram

Figure 14: Typical Color Spectrum

PDF page 18 diagram

100%

90%

PDF page 18 diagram

Notes for Figure 14: 1. Color spectra measured at nominal current for Tj = Tc = 25°C. 2. Color spectra shown is 2700K and 80 CRI. 3. Color spectra shown is 3000K and 80 CRI. 4. Color spectra shown is 4000K and 80 CRI.

Figure 15: Typical Color Spectrum for Décor Series

100%

27H
30H 30G (Décor Series Showcase)

90%

PDF page 18 diagram

Note for Figure 15: 1. Color spectra measured at nominal current for Tj = Tc = 25°C.

Page 19

PDF page 19 diagram

Figure 16: Drawing for V6 HD LED Array

PDF page 19 diagram

Notes for Figure 16: 1. Drawings are not to scale. 2. Drawing dimensions are in millimeters. 3. Unless otherwise specified, tolerances are ±0.1mm. 4. Solder pad labeled “+” denotes positive contact. 5. Refer to Application Notes AN101 for product handling, mounting and heat sink recommendations. 6. The optical center of the LED Array is nominally defined by the mechanical center of the array to a tolerance of ± 0.2mm. 7. Bridgelux maintains a flatness of 0.10mm across the mounting surface of the array.

Page 20

PDF page 20 diagram

Figure 17: Warm and Neutral White Test Bins in xy Color Space

PDF page 20 diagram

Note: Pulsed Test Conditions, Tc = 25°C

Table 8: Warm and Neutral White xy Bin Coordinates and Associated Typical CCT

Bin Code 2700K 3000K1 3500K1 4000K1
ANSI Bin (for reference only) (2580K - 2870K) (2870K - 3220K) (3220K - 3710K) (3710K - 4260K)
73 (3 SDCM) (2651K - 2794K) (2968K - 3136K) (3369K - 3586K) (3851K - 4130K)
Center Point (x,y) (0.4578, 0.4101) (0.4338, 0.403) (0.4465, 0.4024)2 (0.4073, 0.3917) (0.3818, 0.3797)

Notes for Table 8: 1. Color Binning information excludes Décor Series Class A products. Please contact your Bridgelux Sales Representative for more information. 2. Center Point for Decor Series Showcase. 3. Bridgelux maintains a tolerance of +/- 0.007 on x and y color coordinates in the CIE 1931 color Space.

Page 21

PDF page 21 diagram

Figure 18: V6 HD Packaging Tube

PDF page 21 diagram
PDF page 21 diagram

Notes for Figure 18: 1. Each tube holds 35 V6 HD COB arrays. 2. One tube is sealed in an anti-static bag. Four bags are placed in a shipping box. Depending on quantities ordered, a bigger shipping box, containing four boxes may be used to ship products. 3. Each bag and box is to be labeled as shown above. 4. Dimensions for each tube are 15.4 (W) x 8.3 (H) x 430 (L) mm. Dimensions for the anti-static bag are 75 (W) x 615 (L) x 0.075 (T) mm. Dimensions for the shipping box are 58.7 x 13.3 x 7.9 cm

Page 22

PDF page 22 diagram

Figure 19: V Series HD Product Labeling

Bridgelux COB arrays have laser markings on the back side of the substrate to help with product identification. In addition to the product identification markings, Bridgelux COB arrays also contain markings for internal Bridgelux manufacturing use only. The image below shows which markings are for customer use and which ones are for Bridgelux internal use only. The Bridgelux internal manufacturing markings are subject to change without notice, however these will not impact the form, function or performance of the COB array.

PDF page 22 diagram

Customer Use- 2D Barcode Scannable barcode provides product part number and other Bridgelux internal production information.

30E1000B 7 3

Customer Use- Product part number

Internal Bin Code

Page 23

PDF page 23 diagram

Application Notes

Bridgelux has developed a comprehensive set of application notes and design resources to assist customers in successfully designing with the V Series HD product family of LED array products. For all available application notes visit www.bridgelux.com.

Optical Source Models

Optical source models and ray set files are available for all Bridgelux products. For a list of available formats, visit www.bridgelux.com.

Precautions

CAUTION: CHEMICAL EXPOSURE HAZARD

Exposure to some chemicals commonly used in luminaire manufacturing and assembly can cause damage to the LED array. Please consult Bridgelux Application Note AN101 for additional information.

CAUTION: RISK OF BURN

Do not touch the V Series HD LED array during operation. Allow the array to cool for a sufficient period of time before handling. The V Series HD LED array may reach elevated temperatures such that could burn skin when touched.

Disclaimers

MINOR PRODUCT CHANGE POLICY

The rigorous qualification testing on products offered by Bridgelux provides performance assurance. Slight cosmetic changes that do not affect form, fit, or function may occur as Bridgelux continues product optimization.

3D CAD Models

Three dimensional CAD models depicting the product outline of all Bridgelux V Series HD LED arrays are available in both IGS and STEP formats. Please contact your Bridgelux sales representative for assistance.

LM80

LM80 testing has been completed and the LM80 report is now available. Please contact your Bridgelux sales rep­ resentative for LM-80 report.

PDF page 23 diagram

STANDARD TEST CONDITIONS

Unless otherwise stated, array testing is performed at the nominal drive current.

Page 24

PDF page 24 diagram

At Bridgelux, we help companies, industries and people experience the power and possibility of light. Since 2002, we’ve designed LED solutions that are high performing, energy efficient, cost effective and easy to integrate. Our focus is on light’s impact on human behavior, delivering products that create better environments, experiences and returns—both experiential and financial. And our patented technology drives new platforms for commercial and industrial luminaires.

For more information about the company, please visit

bridgelux.com

twitter.com/Bridgelux

facebook.com/Bridgelux

youtube.com/user/Bridgelux

linkedin.com/company/bridgelux-inc-_2

WeChat ID: BridgeluxInChina

46410 Fremont Boulevard Fremont, CA 94538 U.S.A. Tel (925) 583-8400 www.bridgelux.com

© 2021 Bridgelux, Inc. All rights reserved 2020. Product specifications are subject to change without notice. Bridgelux, the Bridgelux stylized logo design and Vero are registered trademarks, V Series and Decor Series are trademarks of Bridgelux, Inc. All other trademarks are the property of their respective owners.

Bridgelux V6 HD Array Series Product Data Sheet DS401 Rev. K (11/2022)