DS100 BRIDGELUX

Document overview

  • PDF pages: 31

Technical content

Page 1

PDF page 1 diagram

Page 2

PDF page 2 diagram

The V Series™ LED Array products deliver high quality light in a compact and cost-effective solid-state lighting package. These chip on board (CoB) arrays can be efficiently driven at twice the nominal drive current, enabling design flexibility not previously possible. This high flux density light source is designed to support a wide range of high quality, low cost directional luminaires and replacement lamps for commercial and residential applications.

The V10 LED array is available in a variety of electrical, CCT and CRI combinations providing substantial design flexibility and energy efficiencies.

Lighting system designs incorporating these LED arrays deliver increased system level efficacy and longer service life. Typical applications include, replacement lamps, and task, accent, spot, track, wide area, security, wall pack and down lights.

Bridgelux Décor Series is our state of the art color line designed specifically for premium applications, producing unmatched LED light quality with brilliant color-rendering options and offer pleasing and inspiring lighting palettes. Bridgelux Décor Series color points are available on Vero® SE Series, Vero® Series, V Series™ and H Series™.

Décor Series Class A is based on human response testing, providing color points with a combined GAI and CRI metric.

Décor Series™ Ultra products provide a high CRI of 97 and a minimum R9 value of 93, which emphasizes the reds and color tones to which the human eye is most receptive - perfect for the most luxurious retail shops and world renowned museums. Décor Series Ultra is designed as a replacement for halogen.

Décor Series™ Street and Landmark is designed to be a direct replacement for high pressure sodium lamps.

Décor Series™ Showcase is the optimal solution for replacing ceramic metal halide lamps, incorporating the same pure white light with enhanced spectrum coverage and higher efficacy.

Features

  • Efficacy of 167 lm/W typical
  • Compact high flux density light source
  • Uniform high quality illumination
  • Minimum 65, 70, 80 and 90 and 95 CRI options
  • Streamlined thermal path
  • ENERGY STAR® / ANSI compliant color binning structure with 2, 3 and 4 SDCM options
  • More energy efficient than incandescent, halogen and fluorescent lamps
  • Low voltage DC operation
  • Instant light with unlimited dimming
  • Vf bin code backside marking

Benefits

  • Enhanced optical control
  • Clean white light without pixilation
  • High quality true color reproduction
  • Significantly reduced thermal resistance and increased operating temperatures
  • Uniform consistent white light
  • Lower operating costs
  • Easy to use with daylight and motion detectors to enable increased energy savings
  • Reduced maintenance costs
  • Environmentally friendly, no disposal issue

Page 3

PDF page 3 diagram
PDF page 3 diagram

Page 4

PDF page 4 diagram

Bridgelux arrays are fully engineered devices that provide consistent thermal and optical performance on an engineered mechanical platform. The V Series arrays are the most compact chip-on-board devices across all of

Bridgelux’s LED Array products. The arrays incorporate several features to simplify design integration and assembly. Please visit www.bridgelux.com for more information on the V Series family of products.

PDF page 4 diagram

Designed to comply with global safety standards for creepage and clearance distances

Fully engineered substrate for consistent thermal, mechanical and optical properties

White ring around LES

Yellow phosphor Light Emitting Surface (LES)

Case Temperature (Tc) Measurement Point

Note: Part number and lot codes are scribed on back of array

PDF page 4 diagram

Page 5

PDF page 5 diagram

The following product configurations are available:

Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C)

Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 T = 25ºC c (lm) Minimum Pulsed Flux6,7 T = 25ºC c (lm) Typical V f (V) Typical Power (W) Typical Efficacy (lm/W)
BXRE-20B1001-B-7x 2000 65 270 1439 1266 34.8 9.5 152
BXRE-27E1000-B-7x 2700 80 270 1458 1283 34.8 9.4 155
BXRE-27E1000-C-7x 2700 80 360 1944 1711 34.8 12.5 155
BXRE-27G10H0-B-7x 2700 90 270 1249 1099 34.8 9.4 133
BXRE-27G10H0-C-7x 2700 90 360 1665 1465 34.8 12.5 133
BXRE-27G1000-B-7x 2700 90 270 1203 1059 34.8 9.4 128
BXRE-27G1000-C-7x 2700 90 360 1604 1412 34.8 12.5 128
BXRE-27H1000-B-7x 2700 97 270 1066 938 34.8 9.4 113
BXRE-27H1000-C-7x 2700 97 360 1422 1251 34.8 12.5 113
BXRE-30C1001-B-7x 3000 70 270 1622 1428 34.8 9.4 173
BXRE-30C1001-C-7x 3000 70 360 2163 1904 34.8 12.5 173
BXRE-30E1000-B-7x 3000 80 270 1549 1363 34.8 9.4 165
BXRE-30E1000-C-7x 3000 80 360 2066 1818 34.8 12.5 165
BXRE-30G10H0-B-7x 3000 90 270 1312 1155 34.8 9.4 140
BXRE-30G10H0-C-7x 3000 90 360 1750 1540 34.8 12.5 140
BXRE-30G1000-B-7x 3000 90 270 1258 1107 34.8 9.4 134
BXRE-30G1000-C-7x 3000 90 360 1677 1476 34.8 12.5 134
BXRE-30G100C-B-7x 3000 90 270 1212 1067 34.8 9.4 129
BXRE-30G100C-C-7x 3000 90 360 1616 1422 34.8 12.5 129
BXRE-30A1001-B-7x8,9 3000 93 270 1130 995 34.8 9.4 120
BXRE-30A1001-C-7x8,9 3000 93 360 1507 1326 34.8 12.5 120
BXRE-30H1000-B-7x 3000 97 270 1139 1003 34.8 9.4 121
BXRE-30H1000-C-7x 3000 97 360 1519 1337 34.8 12.5 121
BXRE-35E1000-B-7x 3500 80 270 1586 1396 34.8 9.4 169
BXRE-35E1000-C-7x 3500 80 360 2114 1861 34.8 12.5 169
BXRE-35G1000-B-7x 3500 90 270 1303 1147 34.8 9.4 139
BXRE-35G1000-C-7x 3500 90 360 1738 1529 34.8 12.5 139
BXRE-35A1001-B-7x8,9 3500 93 270 1203 1059 34.8 9.4 128
BXRE-35A1001-C-7x8,9 3500 93 360 1604 1412 34.8 12.5 128
BXRE-35H1000-B-7x 3500 97 270 1175 1034 34.8 9.4 125
BXRE-35H1000-C-7x 3000 97 360 1566 1378 34.8 12.5 125

Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are typical for Decor Series Ultra, Décor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, Minimum R9 value is 60 for 90 CRI products on 2700K/3000K/3500K and 4000K, it is 50 on 5000K/5700K and 6500K. But for the CRI90 H0 products (higher efficiency CRI90 version), minimum R9 value is 55 on 2700K/3000K/3500K and 4000K. Minimum R9 value for 97 CRI products is 93 on 2700K and 3000K,and it is 85 on 3500K /4000K/5000K and 5700K. Bridgelux maintains a ± 3 tolerance on

R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary

depending on fixture design and performance.

Page 6

PDF page 6 diagram

Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C)(Continued)

Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 T = 25ºC c (lm) Minimum Pulsed Flux6,7 T = 25ºC c (lm) Typical V f (V) Typical Power (W) Typical Efficacy (lm/W)
BXRE-40C1001-B-7x 4000 70 270 1668 1468 34.8 9.4 178
BXRE-40C1001-C-7x 4000 70 360 2224 1957 34.8 12.5 178
BXRE-40E1000-B-7x 4000 80 270 1595 1404 34.8 9.4 170
BXRE-40E1000-C-7x 4000 80 360 2127 1871 34.8 12.5 170
BXRE-40G1000-B-7x 4000 90 270 1331 1171 34.8 9.4 142
BXRE-40G1000-C-7x 4000 90 360 1774 1561 34.8 12.5 142
BXRE-40H1000-B-7x 3500 97 270 1203 1059 34.8 9.4 128
BXRE-40H1000-C-7x 3000 97 360 1604 1412 34.8 12.5 128
BXRE-50C1001-B-7x 5000 70 270 1677 1476 34.8 9.4 178
BXRE-50C1001-C-7x 5000 70 360 2236 1968 34.8 12.5 178
BXRE-50E1001-B-7x 5000 80 270 1613 1420 34.8 9.4 172
BXRE-50E1001-C-7x 5000 80 360 2151 1893 34.8 12.5 172
BXRE-50G1001-B-7x 5000 90 270 1394 1227 34.8 9.4 148
BXRE-50G1001-C-7x 5000 90 360 1859 1636 34.8 12.5 148
BXRE-57C1001-B-7x 5700 70 270 1631 1436 34.8 9.4 174
BXRE-57C1001-C-7x 5700 70 360 2175 1914 34.8 12.5 174
BXRE-57E1001-B-7x 5700 80 270 1549 1363 34.8 9.4 165
BXRE-57E1001-C-7x 5700 80 360 2066 1818 34.8 12.5 165
BXRE-65C1001-B-7x 6500 70 270 1631 1436 34.8 9.4 174
BXRE-65C1001-C-7x 6500 70 360 2175 1914 34.8 12.5 174
BXRE-65E1001-B-7x 6500 80 270 1568 1380 34.8 9.4 167
BXRE-65E1001-C-7x 6500 80 360 2090 1839 34.8 12.5 167

Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are typical for Decor Series Ultra, Décor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, Minimum R9 value is 60 for 90 CRI products on 2700K/3000K/3500K and 4000K, it is 50 on 5000K/5700K and 6500K. But for the CRI90 H0 products (higher efficiency CRI90 version), minimum R9 value is 55 on 2700K/3000K/3500K and 4000K. Minimum R9 value for 97 CRI products is 93 on 2700K and 3000K,and it is 85 on 3500K /4000K/5000K and 5700K. Bridgelux maintains a ± 3 tolerance on

R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary

depending on fixture design and performance.

Page 7

PDF page 7 diagram

Table 2: Selection Guide, Stabilized DC Performance (Tc = 70°C) 7,8

Part Number Nominal CCT1 (K) GAI2 CRI3 Nominal Drive Current4 (mA) Typical DC Flux5,6 T = 70ºC c (lm) Minimum DC Flux6,9 T = 70ºC c (lm) Typical V f (V) Typical Power (W) Typical Efficacy (lm/W)
BXRE-30A1001-B-7x 3000 80 93 270 1051 925 34.3 9.3 113
BXRE-30A1001-C-7x 3000 80 93 360 1401 1233 34.3 12.3 113
BXRE-35A1001-B-7x 3500 80 93 270 1119 985 34.3 9.3 121
BXRE-35A1001-C-7x 3500 80 93 360 1492 1313 34.3 12.3 121

Notes for Table 2: 1. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 2. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance. 3. All CRI values are measured at Tj = Tc = 25°C. CRI Values are specified as typical. 4. Drive current is referred to as nominal drive current. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements.

  1. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 8. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at specified temperature. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 9. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.

Page 8

PDF page 8 diagram

Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5

Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 T = 85ºC c(lm) Minimum DC Flux6 T = 85ºC c(lm) Typical V (V) f Typical Power (W) Typical Efficacy (lm/W)
BXRE-20B1001-B-7x 2000 65 270 1295 1140 33.8 9.1 142
BXRE-27E1000-B-7x 2700 80 270 1312 1155 33.8 9.1 144
BXRE-27E1000-C-7x 2700 80 360 1750 1540 33.8 12.2 144
BXRE-27G10H0-B-7x 2700 90 270 1124 989 33.8 9.1 123
BXRE-27G10H0-C-7x 2700 90 360 1498 1319 33.8 12.2 123
BXRE-27G1000-B-7x 2700 90 270 1083 953 33.8 9.1 119
BXRE-27G1000-C-7x 2700 90 360 1444 1270 33.8 12.2 119
BXRE-27H1000-B-7x 2700 97 270 960 845 33.8 9.1 105
BXRE-27H1000-C-7x 2700 90 360 1280 1126 33.8 12.2 105
BXRE-30C1001-B-7x 3000 70 270 1460 1285 33.8 9.1 160
BXRE-30C1001-C-7x 3000 70 360 1947 1713 33.8 12.2 160
BXRE-30E1000-B-7x 3000 80 270 1394 1227 33.8 9.1 153
BXRE-30E1000-C-7x 3000 80 360 1859 1636 33.8 12.2 153
BXRE-30G10H0-B-7x 3000 90 270 1181 1039 33.8 9.1 129
BXRE-30G10H0-C-7x 3000 90 360 1575 1386 33.8 12.2 129
BXRE-30G1000-B-7x 3000 90 270 1132 996 33.8 9.1 124
BXRE-30G1000-C-7x 3000 90 360 1509 1328 33.8 12.2 124
BXRE-30G100C-B-7x 3000 90 270 1091 960 33.8 9.1 120
BXRE-30G100C-C-7x 3000 90 360 1455 1280 33.8 12.2 120
BXRE-30A1001-B-7x7,8 3000 93 270 1017 895 33.8 9.1 111
BXRE-30A1001-C-7x7,8 3000 93 360 1356 1193 33.8 12.2 111
BXRE-30H1000-B-7x 3000 97 270 1025 902 33.8 9.1 112
BXRE-30H1000-C-7x 3000 97 360 1367 1203 33.8 12.2 112
BXRE-35E1000-B-7x 3500 80 270 1427 1256 33.8 9.1 156
BXRE-35E1000-C-7x 3500 80 360 1903 1675 33.8 12.2 156
BXRE-35G1000-B-7x 3500 90 270 1173 1032 33.8 9.1 128
BXRE-35G1000-C-7x 3500 90 360 1564 1376 33.8 12.2 128
BXRE-35A1001-B-7x7,8 3500 93 270 1083 953 33.8 9.1 119
BXRE-35A1001-C-7x7,8 3500 93 360 1444 1270 33.8 12.2 119
BXRE-35H1000-B-7x 3000 97 270 1057 930 33.8 9.1 116
BXRE-35H1000-C-7x 3000 97 360 1409 1240 33.8 12.2 116

Notes for Table 3: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Décor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, Minimum R9 value is 60 for 90 CRI products on 2700K/3000K/3500K and 4000K, it is 50 on 5000K/5700K and 6500K. But for the CRI90 H0 products (higher efficiency CRI90 version), minimum R9 value is 55 on 2700K/3000K/3500K and 4000K. Minimum R9 value for 97 CRI products is 93 on 2700K and 3000K,and it is 85 on 3500K /4000K/5000K and

5700K. Bridgelux maintains a ± 3 tolerance on R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test

setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance.

Page 9

PDF page 9 diagram

Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5(Continued)

Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 T = 85ºC c(lm) Minimum DC Flux6 T = 85ºC c(lm) Typical V (V) f Typical Power (W) Typical Efficacy (lm/W)
BXRE-40C1001-B-7x 4000 70 270 1501 1321 33.8 9.1 164
BXRE-40C1001-C-7x 4000 70 360 2001 1761 33.8 12.2 164
BXRE-40E1000-B-7x 4000 80 270 1435 1263 33.8 9.1 157
BXRE-40E1000-C-7x 4000 80 360 1914 1684 33.8 12.2 157
BXRE-40G1000-B-7x 4000 90 270 1198 1054 33.8 9.1 131
BXRE-40G1000-C-7x 4000 90 360 1597 1405 33.8 12.2 131
BXRE-40H1000-B-7x 3000 97 270 1083 953 33.8 9.1 119
BXRE-40H1000-C-7x 3000 97 360 1444 1270 33.8 12.2 119
BXRE-50C1001-B-7x 5000 70 270 1509 1328 33.8 9.1 165
BXRE-50C1001-C-7x 5000 70 360 2012 1771 33.8 12.2 165
BXRE-50E1001-B-7x 5000 80 270 1452 1278 33.8 9.1 159
BXRE-50E1001-C-7x 5000 80 360 1936 1704 33.8 12.2 159
BXRE-50G1001-B-7x 5000 90 270 1255 1104 33.8 9.1 137
BXRE-50G1001-C-7x 5000 90 360 1673 1473 33.8 12.2 137
BXRE-57C1001-B-7x 5700 70 270 1468 1292 33.8 9.1 161
BXRE-57C1001-C-7x 5700 70 360 1958 1723 33.8 12.2 161
BXRE-57E1001-B-7x 5700 80 270 1394 1227 33.8 9.1 153
BXRE-57E1001-C-7x 5700 80 360 1859 1636 33.8 12.2 153
BXRE-65C1001-B-7x 6500 70 270 1468 1292 33.8 9.1 161
BXRE-65C1001-C-7x 6500 70 360 1958 1723 33.8 12.2 161
BXRE-65E1001-B-7x 6500 80 270 1411 1242 33.8 9.1 154
BXRE-65E1001-C-7x 6500 80 360 1881 1655 33.8 12.2 154

Notes for Table 3: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Décor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, Minimum R9 value is 60 for 90 CRI products on 2700K/3000K/3500K and 4000K, it is 50 on 5000K/5700K and 6500K. But for the CRI90 H0 products (higher efficiency CRI90 version), minimum R9 value is 55 on 2700K/3000K/3500K and 4000K. Minimum R9 value for 97 CRI products is 93 on 2700K and 3000K,and it is 85 on 3500K /4000K/5000K and

5700K. Bridgelux maintains a ± 3 tolerance on R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test

setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance.

Page 10

PDF page 10 diagram

The European Product Registry for Energy Labeling (EPREL) is defined in the EU Regulation 2017/1369 to provide import­

ant energy efficiency information to consumers. Together with Energy Labeling Regulation ELR (EU) 2019/2015 which was

amended by regulation (EU) 2021/340 for energy labelling of light sources, manufacturers are required to declare an ener­ gy class based on key technical specifications from each of their product and register it in an open data base managed by EPREL It is now a legal requirement for a vendor of light sources to upload information about their products into the EPREL

database before placing these products on the market in the EU.

Table 4 below provides a list of part numbers that are in compliance with ELR and are currently listed in the EPREL data­

base.

At Bridgelux, we are fully committed to supplying products that are compliant with pertinent laws, rules, and obligation

imposed by relevant government bodies including the European Energy Labeling regulation. Customers can use these

products with full confidence for any projects that fall under the ELR.

Table 4: Part numbers registered in European Product Registry for Energy Labeling

PART NUMBER1 CCT (K) CRI Current2 (mA) Vf (V) Useful flux3 (Φuse) at 85C (lm) Pow­ er (W) Efficacy (lm/W) Energy efficiency class4 Regis­ tration No URL to Product Information Sheet in EPREL Database
BXRE-20B1000-B-7x 2000 65 540 35.1 2347 19.0 124 E 869034 https://eprel.ec.europa.eu/qr/869034
BXRE-27E1000-B-7x 2700 80 540 35.1 2392 19.0 126 E 869104 https://eprel.ec.europa.eu/qr/869104
BXRE-27E1000-C-7x 2700 80 720 35.1 3186 25.3 126 E 869108 https://eprel.ec.europa.eu/qr/869108
BXRE-27G10H0-B-7x 2700 90 540 35.1 2048 19.0 108 F 869235 https://eprel.ec.europa.eu/qr/869235
BXRE-27G10H0-C-7x 2700 90 720 35.1 2728 25.3 108 F 869239 https://eprel.ec.europa.eu/qr/869239
BXRE-27G1000-B-7x 2700 90 540 35.1 1973 19.0 104 F 869219 https://eprel.ec.europa.eu/qr/869219
BXRE-27G1000-C-7x 2700 90 670 34.8 2477 23.3 106 F 869224 https://eprel.ec.europa.eu/qr/869224
BXRE-27H1000-B-7x 2700 95 430 34.1 1446 14.6 99 F 869343 https://eprel.ec.europa.eu/qr/869343
BXRE-30C1001-B-7x 3000 70 540 35.1 2661 19.0 140 E 869436 https://eprel.ec.europa.eu/qr/869436
BXRE-30C1001-C-7x 3000 70 720 35.1 3544 25.3 140 E 869442 https://eprel.ec.europa.eu/qr/869442
BXRE-30E1000-B-7x 3000 80 540 35.1 2542 19.0 134 E 869534 https://eprel.ec.europa.eu/qr/869534
BXRE-30E1000-C-7x 3000 80 720 35.1 3385 25.3 134 E 869539 https://eprel.ec.europa.eu/qr/869539
BXRE-30G10H0-B-7x 3000 90 540 35.1 2153 19.0 113 F 869665 https://eprel.ec.europa.eu/qr/869665
BXRE-30G10H0-C-7x 3000 90 720 35.1 2867 25.3 113 F 869669 https://eprel.ec.europa.eu/qr/869669
BXRE-30G1000-B-7x 3000 90 540 35.1 2063 19.0 109 F 869646 https://eprel.ec.europa.eu/qr/869646
BXRE-30G1000-C-7x 3000 90 720 35.1 2748 25.3 109 F 869651 https://eprel.ec.europa.eu/qr/869651
BXRE-30G100C-B-7x 3000 90 540 35.1 2063 19.0 109 F 869661 https://eprel.ec.europa.eu/qr/869661
BXRE-30G100C-C-7x 3000 90 720 35.1 2748 25.3 109 F 869663 https://eprel.ec.europa.eu/qr/869663

Notes for Table 4: 1. All device listed here must be disposed as e-waste upon its end of life according to local country guideline in each country. 2. For information on performance values at alternative drive conditions. please refer to the Product Selection Guide, Absolute Maximum Rating Table and Performance Curves in this data sheet. 3. For a definition of useful luminous flux (ΦΦuse), please see the ELR regulations at https://tinyurl.com/4b6zvt4m. 4. EPREL requires an arrow symbol containing the letter of the energy efficiency class to be displayed. on technical promotional material. Refer to this energy efficiency class column for specific energy efficiency class on each part number.

Page 11

PDF page 11 diagram

Table 4: Part numbers registered in European Product Registry for Energy Labeling (Continued)

PART NUMBER1 CCT (K) CRI Current2 (mA) Vf (V) Useful flux3 (Φuse) at 85C (lm) Pow­ er (W) Efficacy (lm/W) Energy efficiency class4 Regis­ tration No URL to Product Information Sheet in EPREL Database
BXRE-30A1001-B-7x 3000 90 460 34.4 1624 15.8 103 F 869405 https://eprel.ec.europa.eu/qr/869405
BXRE-30A1001-C-7x 3000 90 570 34.0 2031 19.4 105 F 869406 https://eprel.ec.europa.eu/qr/869406
BXRE-30H1000-B-7x 3000 95 500 34.7 1754 17.4 101 F 869795 https://eprel.ec.europa.eu/qr/869795
BXRE-35E1000-B-7x 3500 80 540 35.1 2601 19.0 137 E 869905 https://eprel.ec.europa.eu/qr/869905
BXRE-35E1000-C-7x 3500 80 720 35.1 3464 25.3 137 E 869910 https://eprel.ec.europa.eu/qr/869910
BXRE-35G1000-B-7x 3500 90 540 35.1 2138 19.0 113 F 869997 https://eprel.ec.europa.eu/qr/869997
BXRE-35G1000-C-7x 3500 90 720 35.1 2847 25.3 113 F 870002 https://eprel.ec.europa.eu/qr/870002
BXRE-35A1001-B-7x 3500 90 540 35.1 1973 19.0 104 F 869859 https://eprel.ec.europa.eu/qr/869859
BXRE-35A1001-C-7x 3500 90 670 34.8 2477 23.3 106 F 869860 https://eprel.ec.europa.eu/qr/869860
BXRE-40C1001-B-7x 4000 70 540 35.1 2736 19.0 144 E 870117 https://eprel.ec.europa.eu/qr/870117
BXRE-40C1001-C-7x 4000 70 720 35.1 3644 25.3 144 E 870123 https://eprel.ec.europa.eu/qr/870123
BXRE-40E1000-B-7x 4000 80 540 35.1 2616 19.0 138 E 870212 https://eprel.ec.europa.eu/qr/870212
BXRE-40E1000-C-7x 4000 80 720 35.1 3484 25.3 138 E 870217 https://eprel.ec.europa.eu/qr/870217
BXRE-40G1000-B-7x 4000 90 540 35.1 2183 19.0 115 F 870314 https://eprel.ec.europa.eu/qr/870314
BXRE-40G1000-C-7x 4000 90 720 35.1 2907 25.3 115 F 870319 https://eprel.ec.europa.eu/qr/870319
BXRE-50C1001-B-7x 5000 70 540 35.1 2751 19.0 145 E 870444 https://eprel.ec.europa.eu/qr/870444
BXRE-50C1001-C-7x 5000 70 720 35.1 3664 25.3 145 E 870448 https://eprel.ec.europa.eu/qr/870448
BXRE-50E1001-B-7x 5000 80 540 35.1 2646 19.0 139 E 870515 https://eprel.ec.europa.eu/qr/870515
BXRE-50E1001-C-7x 5000 80 720 35.1 3524 25.3 139 E 870519 https://eprel.ec.europa.eu/qr/870519
BXRE-50G1001-B-7x 5000 90 540 35.1 2287 19.0 121 E 870584 https://eprel.ec.europa.eu/qr/870584
BXRE-50G1001-C-7x 5000 90 720 35.1 3046 25.3 120 E 870588 https://eprel.ec.europa.eu/qr/870588
BXRE-57C1001-B-7x 5700 70 540 35.1 2676 19.0 141 E 870702 https://eprel.ec.europa.eu/qr/870702
BXRE-57C1001-C-7x 5700 70 720 35.1 3564 25.3 141 E 870706 https://eprel.ec.europa.eu/qr/870706
BXRE-57E1001-B-7x 5700 80 540 35.1 2542 19.0 134 E 870757 https://eprel.ec.europa.eu/qr/870757
BXRE-57E1001-C-7x 5700 80 720 35.1 3385 25.3 134 E 870761 https://eprel.ec.europa.eu/qr/870761
BXRE-65C1001-B-7x 6500 70 540 35.1 2676 19.0 141 E 870830 https://eprel.ec.europa.eu/qr/870830
BXRE-65C1001-C-7x 6500 70 720 35.1 3564 25.3 141 E 870834 https://eprel.ec.europa.eu/qr/870834
BXRE-65E1001-B-7x 6500 80 540 35.1 2572 19.0 136 E 870886 https://eprel.ec.europa.eu/qr/870886
BXRE-65E1001-C-7x 6500 80 720 35.1 3425 25.3 135 E 870890 https://eprel.ec.europa.eu/qr/870890

Notes for Table 4: 1. All device listed here must be disposed as e-waste upon its end of life according to local country guideline in each country. 2. For information on performance values at alternative drive conditions. please refer to the Product Selection Guide, Absolute Maximum Rating Table and Performance Curves in this data sheet. 3. For a definition of useful luminous flux (ΦΦuse), please see the ELR regulations at https://tinyurl.com/4b6zvt4m. 4. EPREL requires an arrow symbol containing the letter of the energy efficiency class to be displayed. on technical promotional material. Refer to this energy efficiency class column for specific energy efficiency class on each part number.

Page 12

PDF page 12 diagram

V Series LED arrays are tested to the specifications shown using the nominal drive currents in Table 1. V Series LED Arrays may also be driven at other drive currents dependent on specific application design requirements. The performance at any drive current can be derived from the current vs. voltage characteristics shown in Figures 1 & 2 and the flux vs. current characteristics shown in Figures 3 & 4. The performance at commonly used drive currents is summarized in Table 5.

Table 5: Product Performance at Commonly Used Drive Currents

Part Number CRI Drive Current1 (mA) Typical V f T = 25ºC c (V) Typical Power T = 25ºC c (W) Typical Flux2 T = 25ºC c (lm) Typical DC Flux3 T = 85ºC c (lm) Typical Efficacy T = 25ºC c (lm/W)
BXRE-20B1001-B-7x 65 135 33.2 4.5 767 689 171
180 34.0 6.1 1006 902 164
270 34.8 9.4 1439 1295 153
405 35.6 14.4 2111 1878 146
540 36.1 19.5 2705 2394 139
BXRE-27E1000-B-7x 80 135 33.2 4.5 777 698 173
180 34.0 6.1 1019 914 166
270 34.8 9.4 1458 1312 155
405 35.6 14.4 2139 1903 148
540 36.1 19.5 2741 2426 140
BXRE-27E1000-C-7x 80 180 33.2 6.0 1034 922 173
240 34.0 8.2 1354 1203 166
360 34.8 12.5 1944 1750 155
540 35.6 19.2 2831 2460 147
720 36.1 26.0 3617 3096 139
BXRE-27G10H0-B-7x 90 135 33.2 4.5 665 598 148
180 34.0 6.1 872 783 143
270 34.8 9.4 1249 1124 133
405 35.6 14.4 1832 1630 127
540 36.1 19.5 2347 2077 120
BXRE-27G10H0-C-7x 90 180 33.2 6.0 885 790 148
240 34.0 8.2 1160 1030 142
360 34.8 12.5 1665 1498 133
540 35.6 19.2 2424 2106 126
720 36.1 26.0 3097 2651 119
BXRE-27G1000-B-7x 90 135 33.2 4.5 641 576 143
180 34.0 6.1 841 754 137
270 34.8 9.4 1203 1083 128
405 35.6 14.4 1765 1570 122
540 36.1 19.5 2261 2001 116
BXRE-27G1000-C-7x 90 180 33.2 6.0 853 761 143
240 34.0 8.2 1117 993 137
360 34.8 12.5 1604 1444 128
540 35.6 19.2 2336 2029 121
720 36.1 26.0 2984 2554 115
BXRE-27H1000-B-7x 97 135 33.2 4.5 568 511 127
180 34.0 6.1 745 668 122
270 34.8 9.4 1066 960 113
405 35.6 14.4 1564 1392 108
540 36.1 19.5 2004 1774 103

Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Page 13

PDF page 13 diagram

Table 5: Product Performance at Commonly Used Drive Currents (Continued)

Part Number CRI Drive Current1 (mA) Typical V f T = 25ºC c (V) Typical Power T = 25ºC c (W) Typical Flux2 T = 25ºC c (lm) Typical DC Flux3 T = 85ºC c (lm) Typical Efficacy T = 25ºC c (lm/W)
BXRE-27H1000-C-7x 97 180 33.2 6.0 756 675 126
240 34.0 8.2 990 880 121
360 34.8 12.5 1422 1509 113
540 35.6 19.2 2070 1799 108
720 36.1 26.0 2645 2264 102
BXRE-30C1001-B-7x 70 135 33.2 4.5 864 777 193
180 34.0 6.1 1134 1017 185
270 34.8 9.4 1622 1460 173
405 35.6 14.4 2380 2117 165
540 36.1 19.5 3049 2699 156
BXRE-30C1001-C-7x 70 180 33.2 6.0 1150 1026 192
240 34.0 8.2 1507 1338 185
360 34.8 12.5 2163 1947 173
540 35.6 19.2 3150 2736 164
720 36.1 26.0 4023 3444 155
BXRE-30E1000-B-7x 80 135 33.2 4.5 826 742 184
180 34.0 6.1 1083 971 177
270 34.8 9.4 1549 1394 165
405 35.6 14.4 2273 2022 157
540 36.1 19.5 2912 2577 149
BXRE-30E1000-C-7x 80 180 33.2 6.0 1098 980 184
240 34.0 8.2 1439 1278 176
360 34.8 12.5 2066 1859 165
540 35.6 19.2 3008 2613 156
720 36.1 26.0 3843 3289 148
BXRE-30G10H0-B-7x 90 135 33.2 4.5 699 628 156
180 34.0 6.1 917 823 150
270 34.8 9.4 1312 1181 140
405 35.6 14.4 1925 1713 133
540 36.1 19.5 2467 2183 126
BXRE-30G10H0-C-7x 90 180 33.2 6.0 930 830 156
240 34.0 8.2 1219 1083 149
360 34.8 12.5 1750 1575 140
540 35.6 19.2 2548 2214 132
720 36.1 26.0 3255 2786 125
BXRE-30G1000-B-7x 90 135 33.2 4.5 670 602 149
180 34.0 6.1 879 788 144
270 34.8 9.4 1258 1132 134
405 35.6 14.4 1845 1641 128
540 36.1 19.5 2364 2092 121
BXRE-30G1000-C-7x 90 180 33.2 6.0 892 796 149
240 34.0 8.2 1168 1038 143
360 34.8 12.5 1677 1509 134
540 35.6 19.2 2442 2121 127
720 36.1 26.0 3119 2670 120

Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Page 14

PDF page 14 diagram

Table 5: Product Performance at Commonly Used Drive Currents (Continued)

Part Number CRI Drive Current1 (mA) Typical V f T = 25ºC c (V) Typical Power T = 25ºC c (W) Typical Flux2 T = 25ºC c (lm) Typical DC Flux3 T = 85ºC c (lm) Typical Efficacy T = 25ºC c (lm/W)
BXRE-30G100C-B-7x 90 135 33.2 4.5 646 580 144
180 34.0 6.1 847 760 138
270 34.8 9.4 1212 1091 129
405 35.6 14.4 1778 1582 123
540 36.1 19.5 2278 2016 117
BXRE-30G100C-C-7x 90 180 33.2 6.0 859 767 144
240 34.0 8.2 1126 1000 138
360 34.8 12.5 1616 1455 129
540 35.6 19.2 2353 2045 122
720 36.1 26.0 3006 2573 116
BXRE-30A1001-B-7x 93 135 33.2 4.5 602 541 134
180 34.0 6.1 790 708 129
270 34.8 9.4 1130 1017 120
405 35.6 14.4 1658 1475 115
540 36.1 19.5 2124 1880 109
BXRE-30A1001-C-7x 93 180 33.2 6.0 801 715 134
240 34.0 8.2 1050 932 129
360 34.8 12.5 1507 1356 120
540 35.6 19.2 2194 1906 114
720 36.1 26.0 2803 2399 108
BXRE-30H1000-B-7x 97 135 33.2 4.5 607 546 135
180 34.0 6.1 796 714 130
270 34.8 9.4 1139 1025 121
405 35.6 14.4 1671 1487 116
540 36.1 19.5 2141 1895 110
BXRE-30H1000-C-7x 97 180 33.2 6.0 808 721 135
240 34.0 8.2 1058 940 130
360 34.8 12.5 1519 1409 121
540 35.6 19.2 2212 1922 115
720 36.1 26.0 2825 2419 109
BXRE-35E1000-B-7x 80 135 33.2 4.5 845 759 188
180 34.0 6.1 1108 994 181
270 34.8 9.4 1586 1427 169
405 35.6 14.4 2327 2070 161
540 36.1 19.5 2981 2638 153
BXRE-35E1000-C-7x 80 180 33.2 6.0 1124 1003 188
240 34.0 8.2 1473 1308 180
360 34.8 12.5 2114 1903 169
540 35.6 19.2 3079 2675 160
720 36.1 26.0 3933 3367 151
BXRE-35G1000-B-7x 90 135 33.2 4.5 695 624 155
180 34.0 6.1 911 817 149
270 34.8 9.4 1303 1173 139
405 35.6 14.4 1912 1701 132
540 36.1 19.5 2450 2168 126

Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Page 15

PDF page 15 diagram

Table 5: Product Performance at Commonly Used Drive Currents (Continued)

Part Number CRI Drive Current1 (mA) Typical V f T = 25ºC c (V) Typical Power T = 25ºC c (W) Typical Flux2 T = 25ºC c (lm) Typical DC Flux3 T = 85ºC c (lm) Typical Efficacy T = 25ºC c (lm/W)
BXRE-35G1000-C-7x 90 180 33.2 6.0 924 824 155
240 34.0 8.2 1210 1075 148
360 34.8 12.5 1738 1564 139
540 35.6 19.2 2530 2198 131
720 36.1 26.0 3232 2767 124
BXRE-35A1001-B-7x 93 135 33.2 4.5 641 576 143
180 34.0 6.1 841 754 137
270 34.8 9.4 1203 1083 128
405 35.6 14.4 1765 1570 122
540 36.1 19.5 2261 2001 116
BXRE-35A1001-C-7x 93 180 33.2 6.0 853 761 143
240 34.0 8.2 1117 993 137
360 34.8 12.5 1604 1444 128
540 35.6 19.2 2336 2029 121
720 36.1 26.0 2984 2554 115
BXRE-35H1000-B-7x 97 135 33.2 4.5 626 562 140
180 34.0 6.1 821 736 134
270 34.8 9.4 1175 1057 125
405 35.6 14.4 1723 1533 119
540 36.1 19.5 2207 1954 113
BXRE-35H1000-C-7x 97 180 33.2 6.0 833 743 139
240 34.0 8.2 1091 969 134
360 34.8 12.5 1566 1409 125
540 35.6 19.2 2280 1981 118
720 36.1 26.0 2913 2493 112
BXRE-40C1001-B-7x 70 135 33.2 4.5 889 799 198
180 34.0 6.1 1165 1045 190
270 34.8 9.4 1668 1501 178
405 35.6 14.4 2447 2177 170
540 36.1 19.5 3135 2775 161
BXRE-40C1001-C-7x 70 180 33.2 6.0 1182 1055 198
240 34.0 8.2 1549 1376 190
360 34.8 12.5 2224 2001 178
540 35.6 19.2 3238 2813 168
720 36.1 26.0 4136 3541 159
BXRE-40E1000-B-7x 80 135 33.2 4.5 850 764 190
180 34.0 6.1 1114 1000 182
270 34.8 9.4 1595 1435 170
405 35.6 14.4 2340 2082 162
540 36.1 19.5 2998 2653 154
BXRE-40E1000-C-7x 80 180 33.2 6.0 1131 1009 189
240 34.0 8.2 1481 1316 181
360 34.8 12.5 2127 1914 170
540 35.6 19.2 3097 2690 161
720 36.1 26.0 3956 3386 152

Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Page 16

PDF page 16 diagram

Table 5: Product Performance at Commonly Used Drive Currents (Continued)

Part Number CRI Drive Current1 (mA) Typical V f T = 25ºC c (V) Typical Power T = 25ºC c (W) Typical Flux2 T = 25ºC c (lm) Typical DC Flux3 T = 85ºC c (lm) Typical Efficacy T = 25ºC c (lm/W)
BXRE-40G1000-B-7x 90 135 33.2 4.5 709 637 158
180 34.0 6.1 930 834 152
270 34.8 9.4 1331 1198 142
405 35.6 14.4 1952 1737 135
540 36.1 19.5 2501 2214 128
BXRE-40G1000-C-7x 90 180 33.2 6.0 943 842 158
240 34.0 8.2 1236 1098 151
360 34.8 12.5 1774 1597 142
540 35.6 19.2 2584 2244 134
720 36.1 26.0 3300 2825 127
BXRE-40H1000-B-7x 97 135 33.2 4.5 641 576 143
180 34.0 6.1 841 754 137
270 34.8 9.4 1203 1083 128
405 35.6 14.4 1765 1570 122
540 36.1 19.5 2261 2001 116
BXRE-40H1000-C-7x 97 180 33.2 6.0 853 761 143
240 34.0 8.2 1117 993 137
360 34.8 12.5 1604 1444 128
540 35.6 19.2 2336 2029 121
720 36.1 26.0 2984 2554 115
BXRE-50C1001-B-7x 70 135 33.2 4.5 894 803 199
180 34.0 6.1 1172 1051 191
270 34.8 9.4 1677 1509 178
405 35.6 14.4 2460 2189 170
540 36.1 19.5 3152 2790 161
BXRE-50C1001-C-7x 70 180 33.2 6.0 1189 1061 199
240 34.0 8.2 1557 1384 191
360 34.8 12.5 2236 2012 178
540 35.6 19.2 3256 2828 169
720 36.1 26.0 4159 3560 160
BXRE-50E1001-B-7x 80 135 33.2 4.5 860 773 192
180 34.0 6.1 1127 1011 184
270 34.8 9.4 1613 1452 172
405 35.6 14.4 2367 2105 164
540 36.1 19.5 3032 2684 155
BXRE-50E1001-C-7x 80 180 33.2 6.0 1144 1020 191
240 34.0 8.2 1498 1331 184
360 34.8 12.5 2151 1936 172
540 35.6 19.2 3132 2721 163
720 36.1 26.0 4001 3425 154
BXRE-50G1001-B-7x 90 135 33.2 4.5 743 668 166
180 34.0 6.1 974 874 159
270 34.8 9.4 1394 1255 148
405 35.6 14.4 2046 1820 142
540 36.1 19.5 2621 2320 134

Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Page 17

PDF page 17 diagram

Table 5: Product Performance at Commonly Used Drive Currents (Continued)

Part Number CRI Drive Current1 (mA) Typical V f T = 25ºC c (V) Typical Power T = 25ºC c (W) Typical Flux2 T = 25ºC c (lm) Typical DC Flux3 T = 85ºC c (lm) Typical Efficacy T = 25ºC c (lm/W)
BXRE-50G1001-C-7x 90 180 33.2 6.0 989 882 165
240 34.0 8.2 1295 1150 159
360 34.8 12.5 1859 1673 148
540 35.6 19.2 2707 2352 141
720 36.1 26.0 3458 2960 133
BXRE-57C1001-B-7x 70 135 33.2 4.5 869 781 194
180 34.0 6.1 1140 1022 186
270 34.8 9.4 1631 1468 174
405 35.6 14.4 2393 2129 166
540 36.1 19.5 3066 2714 157
BXRE-57C1001-C-7x 70 180 33.2 6.0 1156 1032 193
240 34.0 8.2 1515 1346 186
360 34.8 12.5 2175 1958 174
540 35.6 19.2 3167 2752 165
720 36.1 26.0 4046 3463 155
BXRE-57E1001-B-7x 80 135 33.2 4.5 826 742 184
180 34.0 6.1 1083 971 177
270 34.8 9.4 1549 1394 165
405 35.6 14.4 2273 2022 157
540 36.1 19.5 2912 2577 149
BXRE-57E1001-C-7x 80 180 33.2 6.0 1098 980 184
240 34.0 8.2 1439 1278 176
360 34.8 12.5 2066 1859 165
540 35.6 19.2 3008 2613 156
720 36.1 26.0 3843 3289 148
BXRE-65C1001-B-7x 70 135 33.2 4.5 869 781 194
180 34.0 6.1 1140 1022 186
270 34.8 9.4 1631 1468 174
405 35.6 14.4 2393 2129 166
540 36.1 19.5 3066 2714 157
BXRE-65C1001-C-7x 70 180 33.2 6.0 1156 1032 193
240 34.0 8.2 1515 1346 186
360 34.8 12.5 2175 1958 174
540 35.6 19.2 3167 2752 165
720 36.1 26.0 4046 3463 155
BXRE-65E1001-B-7x 80 135 33.2 4.5 835 751 186
180 34.0 6.1 1095 982 179
270 34.8 9.4 1568 1411 167
405 35.6 14.4 2300 2046 159
540 36.1 19.5 2946 2608 151
BXRE-65E1001-C-7x 80 180 33.2 6.0 1111 992 186
240 34.0 8.2 1456 1293 178
360 34.8 12.5 2090 1881 167
540 35.6 19.2 3044 2644 158
720 36.1 26.0 3888 3328 149

Notes for Table 5: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.

Page 18

PDF page 18 diagram

Table 6: Electrical Characteristics

Part Number Drive Current (mA) Forward Voltage Pulsed, T = 25ºC (V) 1, 2, 3, 8 c Typical Coefficient of Forward Voltage4 ∆V/∆T f c (mV/ºC) Typical Thermal Resistance Junction to Case5,6 R (ºC/W) j-c Driver Selection Voltages7 (V)
Minimum Typical Maximum
V Min. f Hot T = 105ºC c (V) V Max. f Cold T = -40ºC c (V)
BXRE-xxx100x-B-7x 270 32.2 34.8 37.4 -16.1 0.49 30.9 38.5
540 33.4 36.1 38.8 -16.1 0.56 32.1 39.9
BXRE-xxx100x-C-7x 360 32.2 34.8 37.4 -16.1 0.37 30.9 38.5
720 33.4 36.1 38.8 -16.1 0.45 32.1 39.9

Notes for Table 6: 1. Parts are tested in pulsed conditions, Tc = 25°C. Pulse width is 10ms. 2. Voltage minimum and maximum are provided for reference only and are not a guarantee of performance. 3. Bridgelux maintains a tester tolerance of ± 0.10V on forward voltage measurements. 4. Typical coefficient of forward voltage tolerance is ± 0.1mV for nominal current. 5. Thermal resistance values are based from test data of a 3000K 80 CRI product. 6. Thermal resistance value was calculated using total electrical input power; optical power was not subtracted from input power. The thermal interface material used during testing is not included in the thermal resistance value.

  1. Vf min hot and max cold values are provided as reference only and are not guaranteed by test. These values are provided to aid in driver design and selection over the operating range of the product. 8. This product has been designed and manufactured per IEC 62031:2018. This product has passed dielectric withstand voltage testing at 1160 V. The working voltage designated for the insulation is 80V d.c. The maximum allowable voltage across the array must be determined in the end product application.

Page 19

PDF page 19 diagram

Table 7: Eye Safety Risk Group (RG) Classifications

Part Number Drive Current 5 (mA) CCT1,5
2700K/3000K 4000K2 5000K3 6500K4
BXRE-xxx100x-B-7x 270 RG1 RG1 RG1 RG1
405 RG1 RG1 RG1 RG2
540 RG1 RG1 RG2 RG2
BXRE-xxx100x-C-7x 360 RG1 RG1 RG1 RG2
540 RG1 RG1 RG2 RG2
720 RG1 RG2 RG2 RG2

Notes for Table 7: 1. Eye safety classification for the use of Bridgelux V Series LED arrays is in accordance with specification IEC/TR 62778: Application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires. 2. For products classified as RG2 at 4000K, Ethr= 1847.5 lx. 3. For products classified as RG2 at 5000K Ethr= 1315.8 lx. 4. For products classified as RG2 at 6500K, Ethr= 1124.5 lx. 5. Please contact your Bridgelux sales representative for Ethr values at specific drive currents and CCTs not listed.

Page 20

PDF page 20 diagram

Table 8: Maximum Ratings

Parameter Maximum Rating
LED Junction Temperature (T) j 150°C
Storage Temperature -40°C to +105°C
Operating Case Temperature1 (T) c 105°C
Soldering Temperature2 300°C or lower for a maximum of 6 seconds
BXRE-xxx100x-B-7x BXRE-xxx100x-C-7x
Maximum Drive Current3 540mA 720mA
Maximum Peak Pulsed Drive Current4 770mA 1030mA
Maximum Reverse Voltage5 -60V -60V

Notes for Table 8: 1. For IEC 62717 requirement, please consult your Bridgelux sales representative. 2. Refer to Bridgelux Application Note AN101: Handling and Assembly of Bridgelux V Series LED Arrays. 3. Arrays may be driven at higher currents however lumen maintenance may be reduced. 4. Bridgelux recommends a maximum duty cycle of 10% and pulse width of 20 ms when operating LED Arrays at maximum peak pulsed current specified. Maximum peak pulsed currents indicate values where LED Arrays can be driven without catastrophic failures. 5. Light emitting diodes are not designed to be driven in reverse voltage and will not produce light under this condition. Maximum rating

provided for reference only.

Page 21

PDF page 21 diagram

Figure 1: V10B Drive Current vs. Voltage

PDF page 21 diagram

Figure 3: V10B Typical Relative Flux vs. Current

PDF page 21 diagram

Notes for Figures 1-4:

Figure 2: V10C Drive Current vs. Voltage

PDF page 21 diagram

Figure 4: V10C Typical Relative Flux vs. Current

PDF page 21 diagram
  1. Bridgelux does not recommend driving high power LEDs at low currents. Doing so may produce unpredictable results. Pulse width modulation (PWM) is recommended for dimming effects. 2. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C.

Page 22

PDF page 22 diagram

Figure 5: Typical DC Flux vs. Case Temperature5

Figure 6: Typical DC ccy Shift vs. Case Temperature

PDF page 22 diagram
PDF page 22 diagram

Figure 7: Typical DC ccx Shift vs. Case Temperature

PDF page 22 diagram

Notes for Figures 5-7:

1. Characteristics shown for warm white based on 3000K and 80 CRI.

2. Characteristics shown for neutral white based on 4000K and 80 CRI.

3. Characteristics shown for cool white based on 5000K and 70 CRI.

4. Characteristics shown for warm white includes Decor Series Class A

  1. For other color SKUs, the shift in color will vary. Please contact your Bridgelux Sales Representative for more information.

Page 23

PDF page 23 diagram

Figure 8: 2000K, 65 CRI Color Shift vs. Case Temperature

PDF page 23 diagram

Figure 10: 2700K, 97 CRI Color Shift vs. Case Temperature1

PDF page 23 diagram

Figure 12: 3000K Class A Color Shift vs. Case Temperature1

PDF page 23 diagram

Note for Figures 8-13:

1. Measurements made under DC test conditions at the nominal drive current.

2. Typical color shift is shown with a tolerance of ±0.002. 3. Characteristics shown for Decor Series Showcase products, BXRE-30G100C-x-73

Figure 9: 3000K, 90 CRI Color Shift vs. Case Temperature1,3

PDF page 23 diagram

Figure 11: 3000K, 97 CRI Color Shift vs. Case Temperature1

PDF page 23 diagram

Figure 13: 3500K Class A Color Shift vs. Case Temperature1

PDF page 23 diagram

Page 24

PDF page 24 diagram

Figure 14: Typical Spatial Radiation Pattern

PDF page 24 diagram

Note for Figure 14: 1. Typical viewing angle is 120⁰. 2. The viewing angle is defined as the off axis angle from the centerline where intensity is ½ of the peak value.

Figure 15: Typical Polar Radiation Pattern

PDF page 24 diagram

Page 25

PDF page 25 diagram

Figure 16: Typical Color Spectrum

PDF page 25 diagram

Notes for Figure 16: 1. Color spectra measured at nominal current for Tj = Tc = 25°C. 2. Color spectra shown is 3000K and 80 CRI. 3. Color spectra shown is 4000K and 80 CRI. 4. Color spectra shown is 5000K and 70 CRI. 4. Color spectra shown is 6500K and 70 CRI.

Figure 17: Typical Color Spectrum for Décor Series

1

20B 27H
30H 30G (Décor Series Showcase)

0.9

PDF page 25 diagram

Note for Figure 17: 1. Color spectra measured at nominal current for Tj = Tc = 25°C.

Page 26

PDF page 26 diagram

Figure 18: Drawing for V10 LED Array

PDF page 26 diagram

Notes for Figure 18: 1. Drawings are not to scale. 2. Drawing dimensions are in millimeters. 3. Unless otherwise specified, tolerances are ±0.1mm. 4. Solder pad labeled “+” denotes positive contact. 5. Refer to Application Notes AN101 for product handling, mounting and heat sink recommendations. 6. The optical center of the LED Array is nominally defined by the mechanical center of the array to a tolerance of ± 0.2mm. 7. Bridgelux maintains a flatness of 0.10mm across the mounting surface of the array.

Page 27

PDF page 27 diagram

Figure 19: Warm and Neutral White Test Bins in xy Color Space

PDF page 27 diagram

Note: Pulsed Test Conditions, Tc = 25°C

Figure 20: Cool White Test Bins in xy Color Space

PDF page 27 diagram

Note: Pulsed Test Conditions, Tc = 25°C

Table 9: Warm and Neutral White xy Bin Coordinates and Associated Typical CCT

Bin Code 2000K 2700K 3000K1 3500K1 4000K1
ANSI Bin (for reference only) - (2580K - 2870K) (2870K - 3220K) (3220K - 3710K) (3710K - 4260K)
73 (3 SDCM) - (2651K - 2794K) (2968K - 3136K) (3369K - 3586K) (3851K - 4130K)
72 (2 SDCM) - (2674K - 2769K) (2995K - 3107K) (3404K - 3548K) (3895K - 4081K)
Center Point (x,y) (0.5280, 0.4100) (0.4578, 0.4101) (0.4338, 0.403) (0.4465, 0.4024)2 (0.4073, 0.3917) (0.3818, 0.3797)

Notes for Table 9: 1. Color Binning information excludes Décor Series Class A products. Please contact your Bridgelux Sales Representative for more information. 2. Center Point for Decor Series Showcase. 3. Bridgelux maintains a tolerance of +/- 0.007 on x and y color coordinates in the CIE 1931 color Space.

Table 10: Cool White xy Bin Coordinates and Associated Typical CCT (product is hot targeted to Tc = 85°C)

Bin Code 5000K 5700K 6500K
ANSI Bin (for reference only) (4745K - 5311K) (5312K - 6022K) (6022K - 7042K)
74 (4 SDCM) (4801K - 5282K) (5395K - 5970K)) (6200K - 6910K)
73 (3 SDCM) (4835K - 5215K) (5460K - 5891K)) (6279K - 6811K)
Center Point (x,y) (0.3447, 0.3553) (0.3287, 0.3417) (0.3123, 0.3282)

Note for Table 10: 1. Bridgelux maintains a tolerance of +/- 0.007 on x and y color coordinates in the CIE 1931 color Space.

Page 28

PDF page 28 diagram

Figure 21: V10 Packaging Tube

PDF page 28 diagram
PDF page 28 diagram

Notes for Figure 21: 1. Each tube holds 30 V10 COB arrays. 2. One tube is sealed in an anti-static bag. Four bags are placed in a shipping box. Depending on quantities ordered, a bigger shipping box, containing four boxes may be used to ship products. 3. Each bag and box is to be labeled as shown above. 4. Dimensions for each tube are 8.3 (W) x 15.4 (H) x 430 (L). Dimensions for the anti-static bag are 75 (W) x 615 (L) x 3.1 (T) mm. Dimensions for the shipping box are 58.7 x 13.3 x 7.9 cm

Page 29

PDF page 29 diagram

Figure 22: Gen. 7 Product Labeling

Bridgelux COB arrays have laser markings on the back side of the substrate to help with product identification. In

addition to the product identification markings, Bridgelux COB arrays also contain markings for internal Bridgelux

manufacturing use only. The image below shows which markings are for customer use and which ones are for

Bridgelux internal use only. The Bridgelux internal manufacturing markings are subject to change without notice,

however these will not impact the form, function or performance of the COB array.

PDF page 29 diagram

Customer Use- 2D Barcode Scannable barcode provides product part number and other Bridgelux internal production information.

30E1000C 7 3

Customer Use- Vf Bin Code

Customer Use- Product part number

included to enable greater luminaire design flexibility. Refer to AN92 for bin code definitions.

Internal Bin Code

Page 30

PDF page 30 diagram

Application Notes

Bridgelux has developed a comprehensive set of application notes and design resources to assist customers in successfully designing with the V Series product family of LED array products. For all available application notes visit www.bridgelux.com.

Optical Source Models

Optical source models and ray set files are available for all Bridgelux products. For a list of available formats, visit www.bridgelux.com.

Precautions

CAUTION: CHEMICAL EXPOSURE HAZARD

Exposure to some chemicals commonly used in luminaire manufacturing and assembly can cause damage to the LED array. Please consult Bridgelux Application Note AN101 for additional information.

CAUTION: RISK OF BURN

Do not touch the V Series LED array during operation. Allow the array to cool for a sufficient period of time before handling. The V Series LED array may reach elevated temperatures such that could burn skin when touched.

Disclaimers

MINOR PRODUCT CHANGE POLICY

The rigorous qualification testing on products offered by Bridgelux provides performance assurance. Slight cosmetic changes that do not affect form, fit, or function may occur as Bridgelux continues product optimization.

3D CAD Models

Three dimensional CAD models depicting the product outline of all Bridgelux V Series LED arrays are available in both IGS and STEP formats. Please contact your Bridgelux sales representative for assistance.

LM80

LM80 testing has been completed and the LM80 report is now available. Please contact your Bridgelux sales representative for LM-80 report.

PDF page 30 diagram

STANDARD TEST CONDITIONS

Unless otherwise stated, array testing is performed at the nominal drive current.

Page 31

PDF page 31 diagram

At Bridgelux, we help companies, industries and people experience the power and possibility of light. Since 2002, we’ve designed LED solutions that are high performing, energy efficient, cost effective and easy to integrate. Our focus is on light’s impact on human behavior, delivering products that create better environments, experiences and returns—both experiential and financial. And our patented technology drives new platforms for commercial and industrial luminaires.

For more information about the company, please visit

bridgelux.com

twitter.com/Bridgelux

facebook.com/Bridgelux

youtube.com/user/Bridgelux

linkedin.com/company/bridgelux-inc-_2

WeChat ID: BridgeluxInChina

46410 Fremont Boulevard Fremont, CA 94538 U.S.A. Tel (925) 583-8400 www.bridgelux.com

© 2021 Bridgelux, Inc. All rights reserved. Product specifications are subject to change without notice. Bridgelux, the Bridgelux stylized logo design, Vero, V Series and V Series HD are registered trademarks, and Decor Series is a trademark of Bridgelux, Inc. All other trademarks are the property of their respective owners.

Bridgelux Gen 7 V10 Array Series Product Data Sheet DS100 Rev. T (11/2022)