CX9D0 BELDEN

Document overview

  • PDF pages: 2

Technical content

Page 1

PDF page 1 diagram

Product: CX9D0

CX9D0 - Broadband Coax 9, 17 AWG Solid BC, Trishield, PVC Jkt

Product Description

Broadband Coax 9, 17 AWG Solid Bare Copper Conductor, PE Insulation, Foil + 50% Tinned Copper Braid + Foil Shield, PVC Jacket.

Technical Specifications

Product Overview

Broadband, Cable Television (CATV), RF drop cable, Over-The-Air (OTA) antennas

Suitable Applications:

Construction Details

Conductor

No. of Elements Size Stranding Nom. Diameter Material
1 18 AWG Solid 1.1 mm BC - Bare Copper

Insulation

Material Nom. Insulation Diameter
PE - Polyethylene (Foam) 4.8 mm (0.19 in)
Table Notes: Gas Injected

Outer Shield

Layer Outer Shield Type Material Coverage
1 Tape Tri-Laminate (Alum+Poly+Alum) 100%
2 Braid Tinned Copper (TC) 70%
3 Tape Bi-Laminate (Alum+Poly) 100%
Table Notes: Foil Tape has L-Fold and is bonded to the sheath

Outer Jacket

Material Nom. Diameter
PVC - Polyvinyl Chloride 7.1 mm
Table Notes: According to European Standard EN 50290-2-20

Electrical Characteristics

Regularity of Impedance:

40 dB

Return Loss (RL)

Frequency Min. Return Loss
30-470 MHz 27 dB
470-1000 MHz 24 dB
1000-2000 MHz 18 dB
2000-3000 MHz 16 dB

Attenuation

PDF page 1 diagram

Page 2

200 MHz 8.2 dB/100m
400 MHz 11.8 dB/100m
600 MHz 14.7 dB/100m
800 MHz 17.2 dB/100m
1000 MHz 19.4 dB/100m
1350 MHz 23.0 dB/100m
1750 MHz 27.0 dB/100m
2000 MHz 28.7 dB/100m
2150 MHz 30.0 dB/100m
2400 MHz 32.0 dB/100m
3000 MHz 36.0 dB/100m
Table Notes: Maximum attenuation is 10% higher

Electricals

Max. Conductor DCR Nom. Outer Shield DCR Nom. Capacitance Cond-to-Shield Nom. Characteristic Impedance Nom. Velocity of Prop.
19 Ohm/km (5.8 Ohm/1000ft) 14 Ohm/km (4.3 Ohm/1000ft) 51 pF/m (16 pF/ft) 75 Ohm 86%

Transfer Impedance

Frequency Max. Transfer Impedance
5-30 MHz max. 2.5 mOhm/m

Screening

Frequency Min. Screening Attenuation
30-1000 MHz 95 dB
1000-2000 MHz 85 dB
2000-3000 MHz 75 dB
Screening Class: A+

Mechanical Characteristics

Temperature

Operating

Storage

-40°C To +70°C -40°C To +70°C

Bend Radius

Stationary Min.
35 mm (1.4 in)
Max. Pull Tension: 60 N (13 lbf)
Bulk Cable Weight: 51 kg/km

Standards and Compliance

Environmental Suitability:

Indoor - Euroclass Eca

Flammability / Reaction to Fire:

IEC 60332-1-2

CPR Compliance:

CPR Euroclass: Eca

CENELEC Compliance:

EN 50117-1

UK Regulation Compliance:

UKCA Mark

History

Update and Revision:

Revision Number: 0.110 Revision Date: 12-19-2022

© 2024 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,

negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product

Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product.