CX9A2 BELDEN

Document overview

  • PDF pages: 2

Technical content

Page 1

PDF page 1 diagram

Product: CX9A2

CX9A2 - Broadband Coax 9, 17 AWG Solid BC, Foil + 70% BC Braid, PVC Jkt

Product Description

Broadband Coax 9, 17 AWG Solid Bare Copper Conductor, PE Insulation, Foil + 70% Tinned Copper Braid Shield, PVC Jacket.

Technical Specifications

Product Overview

Broadband, Cable Television (CATV), RF drop cable, Over-The-Air (OTA) antennas

Suitable Applications:

Construction Details

RG Type:

6

Conductor

No. of Elements Size Stranding Nom. Diameter Material
1 17 AWG Solid 1.13 mm BC - Bare Copper

Insulation

Material Nom. Insulation Diameter
PE - Polyethylene (Foam) 4.8 mm (0.19 in)
Table Notes: Gas Injected

Outer Shield

Layer Outer Shield Type Material Coverage
1 Tape Tri-Laminate (Alum+Poly+Alum) 100%
2 Braid Tinned Copper (TC) 70%

Outer Jacket

Material Nom. Diameter
PVC - Polyvinyl Chloride 6.8 mm

Electrical Characteristics

Regularity of Impedance:

40 dB

Return Loss (RL)

Frequency Min. Return Loss
5-470 MHz 23 dB
470-1000 MHz 20 dB
1000-2000 MHz 18 dB
2000-3000 MHz 16 dB
Table Notes: Max. 3 peak values 4 dB lower than specified

Attenuation

PDF page 1 diagram

Page 2

400 MHz 11.8 dB/100m

600 MHz 14.7 dB/100m

800 MHz 17.2 dB/100m

1000 MHz 19.4 dB/100m

1350 MHz 23.0 dB/100m

1750 MHz 27 dB/100m

2000 MHz 28.7 dB/100m

2150 MHz 30 dB/100m

2400 MHz 32 dB/100m

3000 MHz 36 dB/100m

Electricals

Max. Conductor DCR Nom. Outer Shield DCR Nom. Capacitance Cond-to-Shield Nom. Characteristic Impedance Nom. Velocity of Prop.
19 Ohm/km (5.8 Ohm/1000ft) 14 Ohm/km (4.3 Ohm/1000ft) 51 pF/m (16 pF/ft) 75 Ohm 87%

Screening

Frequency Min. Screening Attenuation
30-1000 MHz 85 dB
1000-2000 MHz 75 dB
2000-3000 MHz 65 dB
Screening Class: A

Mechanical Characteristics

Temperature

Operating Storage
-40°C To +70°C -40°C To +70°C
Bulk Cable Weight: 49 kg/km

Standards and Compliance

Environmental Suitability:

Indoor/Outdoor

CENELEC Compliance:

EN 50117-1

History

Update and Revision:

Revision Number: 0.155 Revision Date: 04-08-2022

© 2024 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,

negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product

Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product.