CX4C1 BELDEN
Document overview
- PDF pages: 2
Technical content
Page 1

Product: CX4C1
CX4C1 - Broadband Coax 4, 11 AWG Solid BC, BC Foil, PE Jkt
Product Description
Broadband Coax 4,11 AWG Solid Bare Copper Conductor, PE Insulation, Copper Foil Shield, PE Jacket.
Technical Specifications
Product Overview
Suitable Applications:
Broadband, Cable Television (CATV)
Construction Details
Series Type:
CATV-Trunk Type
Conductor
| No. of Elements | Size | Stranding | Nom. Diameter | Material |
| 1 | 12 AWG | Solid | 2.23 mm | BC - Bare Copper |
Insulation
| Element | Material | Nom. Insulation Diameter | |
| Insulated Conduct | or PE - Polyethylene (Foam) | 10.2 mm (0.402 in) | |
| Table Notes: Centricity min. 85% | |||
Outer Shield
| Outer Shield Typ | e Material | Coverage |
|---|---|---|
| Tape | Bare Copper (BC) | 100% |
Outer Jacket
| Material | Nom. Diameter | |
| PE - Polyethylene | 13.8 mm | |
| Table Notes: According to European Standard EN 50290-2-20 | ||
Electrical Characteristics
Regularity of Impedance:
Min. 46 dB
Return Loss (RL)
| Frequency | Min. Return Loss | |
| 5 - 30 MHz | 26 dB | |
| 30 - 470 MHz | 26 dB | |
| 470 - 862 MHz | 23 dB | |
| 862 - 2400 MHz | 18 dB | |
| Table Notes: In each frequency band, 3 peak values up to 4 dB lower are allowed | ||
Attenuation

Page 2
| 400 MHz | 5.9 dB/100m | |
| 600 MHz | 7.4 dB/100m | |
| 800 MHz | 8.8 dB/100m | |
| 1000 MHz | 10 dB/100m | |
| 1350 MHz | 11.9 dB/100m | |
| 1750 MHz | 13.9 dB/100m | |
| 2150 MHz | 15.7 dB/100m | |
| 2400 MHz | 16.8 dB/100m | |
| Table Notes: Max. attenuation 10% higher | ||
Electricals
| Max. Conductor DCR | Nom. Outer Shield DCR | Nom. Capacitance Cond-to-Shield | Nom. Characteristic Impedance | Nom. Velocity of Prop. |
|---|---|---|---|---|
| 4.5 Ohm/km (1.4 Ohm/1000ft) | 4.5 Ohm/km (1.4 Ohm/1000ft) | 54 pF/m (16 pF/ft) | 75 Ohm | 82% |
Transfer Impedance
Max. Transfer Impedance
Max. 1.9 mOhm/m
Screening
| Frequency | Min. Screening Attenuation | |
|---|---|---|
| 30 - 1000 MHz | 90 dB | |
| Screening Class: A+ | ||
Mechanical Characteristics
Temperature
| Operating | Installation | Storage |
| -40°C To +70°C | -5°C To +50°C | -40°C To +70°C |
Bend Radius
| Stationary Min. | |
|---|---|
| 150 mm (5.9 in) | |
| Max. Pull Tension: 600 N (130 lbf) | |
| Bulk Cable Weight: 164 kg/km | |
Standards and Compliance
Environmental Suitability:
Outdoor
ISO/IEC Compliance:
IEC 61196
CENELEC Compliance:
EN 50117-1
European Directive Compliance:
EU CE Mark
History
Update and Revision:
Revision Number: 0.199 Revision Date: 04-08-2022
© 2024 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product
Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product.