Datasheet CX4C0

Document overview

  • PDF pages: 2

Technical content

Page 1

Product Datasheet

CX4C0 (FB14)

CATV Trunk Cable

Rev. 2/ 2005-11-30 2/2

Application

Low loss coaxial cable offer an optimum attenuation performance in cable broadband communication networks where longer runs are required. Designed according the European Standard EN 50117-1 and draft EN 50117-2-4 May 2002, EN 50083-2/A1 Screening class A+ Construction & Dimensions 4 3.2 3.1 2 1

  1. Conductor
  1. Dielectric

3.1 Foil 3.2 Braid

  1. Jacket
  1. Inner Conductor Innenleiter - Conduttore Interno – Conducteur – Conductor - Проводник Material

solid, bare copper

Diameter

2.23 mm

  1. Dielectric Dielektrikum – Dielettrico – Diélectrique – Dieléctrico - Диэлектрик Material

Gas injected PE

Diameter over insulation

10.2 mm

  1. Outer Conductor Aussenleiter - Conduttore Esterno - Conducteur extérieur - Conductor externo - Внешний проводник Material

foil + braid

Diameter screen

11.0 mm

3.1 Shielding foil

cu foil

Coverage:

100%

3.2 Shielding braid

bare copper braid

Coverage

60% ± 5%

  1. Jacket Aussenmantel – Guaina – Gaine – Revestimiento - Оболочка Material Diameter: Color and text: Requirements and test methods

Electrical characteristics

Mean characteristic impedance:

PE 13.80 + 0.2 mm see table Marking

75 ± 3 Ω

Wellenwiderstand - Impedenza Caratteristica Principale - Impédance nominale - Características eléctricas - Электрические характеристики Nominal capacitance conductor to shield:

54 pF/m

Kapazitaet - Capacità Nominale Conduttore/Schermo - Capacité nominale entre conducteur et blindage - Capacitancia nominal de conductor a blindaje - Номинальная емкость “проводник-экран” Nominal velocity of propagation:

82%

Ausbreitungsgeschwindigkeit - Velocità Nominale di Propagazione - Vitesse de propagation nominale - Velocidad nominal de propagación - Номинальная скорость распространения сигнала Max. DC loop resistance:

9.0 Ω/km

 Belden Wire & Cable B.V. Netherlands Tel. +31-(0)77-3878-555 - Fax. +31-(0)77-3878-488 - E-mail: Venlo.salesinfo@beldencdt.com All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of the copyright owner. All printing errors are subject to correction. Technical specifications are subject to change without notice.

Page 2

Product Datasheet

CX4C0 (FB14)

CATV Trunk Cable

Rev. 2/ 2005-11-30 2/2

Schleifenwiderstand – Resistenza continua di Loop – Resistenza (DC) di Loop - Resistencia de bucle CC - Сопротиление петли пост. Тока

Max. inner conductor DC resistance @ 20 ˚C: 4.5 Ω/km

Gleichstromwiderstand Innenleiter - Resistenza Nominale DC del Conduttore Interno - Résistance du conducteur intérieur - Resistencia CC nominal del conductor interno - Номин. сопротивление пост. тока внутреннего проводника при

Max. outer conductor DC resistance @ 20 ˚C: 4.5 Ω/km

Gleichstromwiderstand Aussenleiter - Resistenza Nominale DC del Conduttore Esterno - Résistance du conducteur extérieur - Resistencia CC nominal del conductor externo - Номин. сопротивление пост. тока внутреннего проводника при

 Belden Wire & Cable B.V. Netherlands Tel. +31-(0)77-3878-555 - Fax. +31-(0)77-3878-488 - E-mail: Venlo.salesinfo@beldencdt.com All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of the copyright owner. All printing errors are subject to correction. Technical specifications are subject to change without notice.