CPS12E EH

Document overview

  • Manufacturer or author: Provided By www.digicamel.com(free datasheet download site)
  • PDF pages: 12

Technical content

Digital with Memosens 2.0 technology Application

  • Long-term monitoring and limit control in processes with stable process conditions
  • Chemical industry
  • Pulp and paper industry
  • Power plants (e. g. flue gas cleaning)
  • Incinerator plants
  • Water treatment
  • Drinking water
  • Cooling water
  • Well water With ATEX, IECEx, CSA C/US, NEPSI, Japan and INMETRO approvals for use in hazardous areas Zone 0, Zone 1 and Zone 2. Your benefits
  • Robust sensor with long diffusion path for poisoning substances
  • Low-maintenance due to large, dirt-repellent PTFE diaphragm
  • Suitable for tough applications: process glass for highly alkaline media
  • Can be used at pressures up to 17 bar (246.5 psi) (absolute)
  • Integrated NTC 30K temperature sensor
  • Different measuring elements for use in oxidizing and reducing media Other advantages provided by Memosens technology
  • Maximum process safety thanks to non-contact, inductive signal transmission
  • Data security thanks to digital data transmission
  • Very easy to use as sensor data are saved in the sensor
  • Predictive maintenance can be performed by recording sensor load data in the sensor Products Solutions Services Technical Information Memosens CPS12E ORP sensor for standard applications in process technology and environmental engineering TI01494C/07/EN/01.20 71486979 2020-06-29

2 Endress+Hauser

Function and system design Measuring principle ORP measurement The ORP potential is a unit of measurement for the state of equilibria between oxidizing and reducing components of a medium. The ORP is measured using a platinum or gold electrode. Similar to pH measurement, an integrated Ag/AgCl reference system is used as a reference electrode. Measuring system The complete measuring system comprises at least:

  • ORP sensor CPS12E
  • Memosens data cable CYK10 or CYK20
  • Transmitter, e. g. Liquiline CM44, Liquiline CM42
  • Assembly
  • Immersion assembly, e. g. Dipfit CPA111
  • Flow assembly, e. g. Flowfit CPA250
  • Retractable assembly, e. g. Cleanfit CPA871
  • Permanent installation assembly, e. g. Unifit CPA842 Additional options are available depending on the application: Automatic cleaning and calibration system, e. g. Liquiline Control CDC90 A0032144  1 Example of a measuring system for ORP measurement

1 Retractable assembly Cleanfit CPA871

2 ORP sensor CPS12E

3 Memosens data cable CYK10

4 Transmitter Liquiline CM44x

The ORP sensor is available with a gold or platinum electrode:

  • Gold electrode For oxidizing media, e. g. cyanide oxidization, nitrite oxidization, ozone measurement, hydrogen superoxide measurement
  • Platinum electrode For reducing media, e. g. chromate reduction or for chlorine dosing in swimming pools Communication and data processing Communication with the transmitter Always connect digital sensors with Memosens technology to a transmitter with Memosens technology. Data transmission to a transmitter for analog sensors is not possible.

Digital sensors can store measuring system data in the sensor. These include the following:

  • Manufacturer data
  • Serial number
  • Order code
  • Date of manufacture
  • Calibration data
  • Calibration date
  • Offset of integrated temperature sensor
  • Offset of ORP measurement
  • Number of calibrations
  • Calibration history
  • Serial number of the transmitter used to perform the last calibration or adjustment
  • Operating data
  • Temperature application range
  • ORP application range
  • Date of initial commissioning
  • Maximum temperature value
  • Hours of operation under extreme conditions
  • Number of sterilizations
  • CIP counter Dependability Reliability Easy handling Sensors with Memosens technology have integrated electronics that store calibration data and other information (e. g. total hours of operation or operating hours under extreme measuring conditions). Once the sensor has been connected, the sensor data are transferred automatically to the transmitter and used to calculate the current measured value. As the calibration data are stored in the sensor, the sensor can be calibrated and adjusted independently of the measuring point. The result:
  • Easy calibration in the measuring lab under optimum external conditions increases the quality of the calibration.
  • Pre-calibrated sensors can be replaced quickly and easily, resulting in a dramatic increase in the availability of the measuring point.
  • Thanks to the availability of the sensor data, maintenance intervals can be accurately defined and predictive maintenance is possible.
  • The sensor history can be documented on external data carriers and in evaluation programs.
  • The saved application data of the sensor can be used to determine the continued use of the sensor in a targeted manner. Interference immunity Data security thanks to digital data transmission Memosens technology digitizes the measured values in the sensor and transmits the data to the transmitter via a non-contact connection that is free from potential interference. The result:
  • If the sensor fails or there is an interruption in the connection between the sensor and transmitter, this is reliably detected and reported.
  • The availability of the measuring point is reliably detected and reported. Safety Maximum process safety With inductive transmission of the measured value using a non-contact connection, Memosens guarantees maximum process safety and offers the following benefits:
  • All problems caused by moisture are eliminated:
  • No corrosion at the connection
  • Measured values cannot be distorted by moisture
  • The transmitter is galvanically decoupled from the medium. Issues concerning "symmetrical high- impedance" or "asymmetry" or the type of impedance converter are a thing of the past.
  • Electromagnetic compatibility (EMC) is guaranteed by screening measures for the digital transmission of measured values.
  • Intrinsically safe electronics mean operation in hazardous areas is not a problem. Complete flexibility thanks to individual Ex approvals for all components, such as sensors, cables and transmitters.

4 Endress+Hauser

Measuring range –1 500 to 1 500 mV Pay attention to the operating conditions in the process. Power supply Electrical connection GN/YE YE GN BN WH GND Com A Com B GY A0024019  2 Measuring cable CYK10 or CYK20 ‣ Memosens measuring cable, e. g. Connect the CYK10 or CYK20 to the sensor. For further information on cable CYK10, see BA00118C. Performance characteristics Reference system Ag/AgCl reference lead with Advanced Gel 3 M KCl Installation Orientation • Do not install the sensors upside-down.

  • The installation angle from the horizontal must be at least 15°. An installation angle < 15° is not permitted, as otherwise the electrolyte may separate from the diaphragm at elevated temperatures. The electrolytic contact is then no longer guaranteed. 15° 15° A B A0028039  3 Installation angle at least 15° from the horizontal A Permitted orientation B Incorrect orientation

Installation instructions • Before screwing in the sensor, make sure the assembly thread, the O-rings and the sealing surface are clean and undamaged and that the thread runs smoothly.

  • Pay attention to the installation instructions provided in the Operating Instructions of the assembly used. ‣ Screw in the sensor and tighten by hand with a torque of 3 Nm (2.21 lbf ft) (specifications only apply if installing in Endress+Hauser assemblies). For detailed information on removing the moistening cap, see BA01988C Environment Ambient temperature range NOTICE Risk of damage from frost! ‣ Do not use the sensor at temperatures below –15 °C (5 °F) . Storage temperature 0 to 50 °C (32 to 122 °F) Degree of protection IP 68 (10 m (33 ft) water column, 25 °C (77 °F), 45 days, 1 M KCl) Electromagnetic compatibility (EMC) Interference emission and interference immunity as per EN 61326-1: 2013 Process Process temperature range –15 to 135 °C (5 to 275 °F) Process pressure range 0.8 to 17 bar (11.6 to 246.5 psi) absolute LCAUTION Pressurization of sensor due to prolonged use under increased process pressure Possibility of sudden rupture and injury from glass splinters! ‣ Avoid fast heating of these pressurized sensors if they are used under reduced process pressure or under atmospheric pressure. ‣ When handling these sensors, always wear protective goggles and appropriate protective gloves. Conductivity Reference system AA: minimum 50 μS/cm (minimized flow; pressure and temperature must be stable)

6 Endress+Hauser

-15 232 16 5 212 0 100 [°C] T [°F] 20 40 60 80 120 24832 68 104 140 176 [psi] p [bar] 116 145 174 203 0 0 x 284 140 A 18261 A0041477-EN  4 Pressure-temperature ratings A Applications G and P x Atmospheric pressure Mechanical construction Design, dimensions Ø 12 (0.47) 120 / 225 / 360 50 (1.97) A0042537  5 CPS12E with Memosens plug-in head. Engineering unit: mm (in)

1 Memosens plug-in head with process connection

2 O-ring with thrust collar

3 Internal reference lead

4 Reference lead

5 Temperature sensor

6 Junction

7 Gold or platinum electrode

Weight Installed length 120 mm (4.72 in) 225 mm (8.86 in) 360 mm (14.17 in) 425 mm (16.73 in) Weight 40 g (1.4 oz) 60 g (2.1 oz) 90 g (3.2 oz) 100 g (3.5 oz) Materials Sensor shaft Glass to suit process ORP measuring element Platinum or gold Metal lead Ag/AgCl Aperture Ring-shaped PTFE diaphragm, sterilizable O-ring FKM Process coupling PPS fibre-glass reinforced Nameplate ceramic metal oxide Temperature sensor NTC 30K Plug-in head Memosens plug-in head for digital, non-contact data transmission, pressure resistance 16 bar (232 psi)(relative) Process connections Pg 13.5 Certificates and approvals  mark The product meets the requirements of the harmonized European standards. As such, it complies with the legal specifications of the EU directives. The manufacturer confirms successful testing of the product by affixing to it the  mark. Ex approval ATEX II 1G Ex ia IIC T3/T4/T6 Ga IECEx Ex ia IIC T3/T4/T6 Ga NEPSI Ex ia IIC T3/T4/T6 Ga CSA C/US

  • IS Cl. I Div 1, GP A-D Ex ia IIC T3/T4/T6
  • IS Cl. I Zone 0, AEx ia IIC T3/T4/T6 Japan Ex Ex ia IIC T3/T4/T6 Ga INMETRO Ex ia IIC T3/T4/T6 Ga Ex versions of digital sensors with Memosens technology are identified by an orange-red ring on the plug-in head. Pay attention to the instructions for Memosens data cable CYK10 and transmitter CM82. TÜV certificate for Memosens plug-in head Pressure resistance 16 bar (232 psi) relative, minimum three times the safety pressure EAC The product has been certified according to guidelines TP TC 004/2011 and TP TC 020/2011 which apply in the European Economic Area (EEA). The EAC conformity mark is affixed to the product.

Ordering information

Product page www.endress.com/cps12e

8 Endress+Hauser

Product Configurator On the product page there is a Configure button to the right of the product image. 1. Click this button.  The Configurator opens in a separate window. 2. Select all the options to configure the device in line with your requirements.  In this way, you receive a valid and complete order code for the device. 3. Export the order code as a PDF or Excel file. To do so, click the appropriate button on the right above the selection window. For many products you also have the option of downloading CAD or 2D drawings of the selected product version. Click the CAD tab for this and select the desired file type using picklists. Scope of delivery The delivery comprises:

  • Sensor in the version ordered
  • Operating Instructions
  • Safety instructions for the hazardous area (for sensors with Ex approval) Accessories The following are the most important accessories available at the time this documentation was issued. ‣ For accessories not listed here, please contact your Service or Sales Center. Device-specific accessories Assemblies Unifit CPA842
  • Installation assembly for food, biotechnology and pharmaceutics
  • With EHEDG and 3A certificate
  • Product Configurator on the product page: www.endress.com/cpa842 Technical Information TI01367C Cleanfit CPA875
  • Retractable process assembly for sterile and hygienic applications
  • For in-line measurement with standard sensors with 12 mm diameter, e.g. for pH, ORP, oxygen
  • Product Configurator on the product page: www.endress.com/cpa875 Technical Information TI01168C Dipfit CPA140
  • pH/ORP immersion assembly with flange connection for very demanding processes
  • Product Configurator on the product page: www.endress.com/cpa140 Technical Information TI00178C Cleanfit CPA871
  • Flexible process retractable assembly for water, wastewater and the chemical industry
  • For applications with standard sensors with 12 mm diameter
  • Product Configurator on the product page: www.endress.com/cpa871 Technical Information TI01191C Cleanfit CPA450
  • Manual retractable assembly for installing sensors with a diameter of 120 mm in tanks and pipes
  • Product Configurator on the product page: www.endress.com/cpa450 Technical Information TI00183C
  • Stainless steel process retractable assembly with ball valve shutoff for particularly reliable separation of the medium from the environment
  • Product Configurator on the product page: www.endress.com/cpa473 Technical Information TI00344C Cleanfit CPA474
  • Plastic process retractable assembly with ball valve shutoff for particularly reliable separation of the medium from the environment
  • Product Configurator on the product page: www.endress.com/cpa474 Technical Information TI00345C Dipfit CPA111
  • Immersion and installation assembly made of plastic for open and closed vessels
  • Product Configurator on the product page: www.endress.com/cpa111 Technical Information TI00112C Flowfit CPA240
  • pH/ORP flow assembly for processes with stringent requirements
  • Product Configurator on the product page: www.endress.com/cpa240 Technical Information TI00179C Flowfit CPA250
  • Flow assembly for pH/ORP measurement
  • Product Configurator on the product page: www.endress.com/cpa250 Technical Information TI00041C Ecofit CPA640
  • Set comprising adapter for 120 mm pH/ORP sensors and sensor cable with TOP68 coupling
  • Product Configurator on the product page: www.endress.com/cpa640 Technical Information TI00246C Buffer solutions ORP buffer solution CPY3
  • 220 mV, pH 7, 250 ml (8.5 fl oz)
  • 468 mV, pH 0.1, 250 ml (8.5 fl oz) Product Configurator on the product page: www.endress.com/cpy3 Measuring cable Memosens data cable CYK10
  • For digital sensors with Memosens technology
  • Product Configurator on the product page: www.endress.com/cyk10 Technical Information TI00118C Memosens laboratory cable CYK20
  • For digital sensors with Memosens technology
  • Product Configurator on the product page: www.endress.com/cyk20

www.addresses.endress.com