SERIES: CP90H │ DESCRIPTION: PELTIER MODULE cuidevices.com
FEATURES
- arcTEC™ structure on select models
- enhanced reliability for high thermal cycling
- superior thermal performance
- silicon sealed
- wide ΔT max
- low profile
- precise temperature control
- solid state construction MODEL input voltage1 input current2 internal resistance3 output Qmax4 output ∆Tmax5 max (Vdc) max (A) typ (Ω±10%) Th=27°C (W) Th=50°C (W) Th=27°C (°C) Th=50°C (°C) CP9040335H6 15.4 9.0 1.29 79 92 70 77 CP906262576 15.4 9.0 1.31 79 92 70 77 Notes: 1. Maximum voltage at ΔT max and Th=27°C 2. Maximum current to achieve ΔT max 3. Measured by AC 4-terminal method at 25°C 4. Maximum heat absorbed at cold side occurs at Imax, Vmax, and ∆T=0°C 5. Maximum temperature difference occurs at Imax, Vmax, and Q=0W (ΔT max measured in a vacuum at 1.3 Pa) 6. Designed with arcTEC™ structure. Additional Resources: Product Page | 3D Model
date 11/12/2020 │ page 2 of 6CUI Devices │ SERIES: CP90H │ DESCRIPTION: PELTIER MODULE cuidevices.com COLD SIDE HOT SIDE0.05 0.05 THICKNESS COLD SIDE Black (-) Red (+) WIDTH LENGTH 100.0 5.0 10.0 3.0 SPECIFICATIONS parameter conditions/description min typ max units solder melting temperature connection between thermoelectric pairs 235 °C assembly compression 1 MPa RoHS yes MECHANICAL DRAWING units: mm MATERIAL PLATING ceramic plate 96% AL2O3 wire leads (CP90626257) 18 AWG tin wire leads (all other models) 20 AWG tin sealer silicon rubber 703 RTV (between cold and hot side plates) joint cover silicon rubber 703 RTV marking P/N & S/N printed on cold side surface MODEL NO. LENGTH (mm) WIDTH (mm) THICKNESS (mm) CP902015343H 20 ±0.3 15 ±0.3 3.43 ±0.03 CP9040335H 40 ±0.3 40 ±0.3 3.35 ±0.025 CP90626257 62 ±0.3 62 ±0.3 5.7 ±0.05 Additional Resources: Product Page | 3D Model
date 11/12/2020 │ page 3 of 6CUI Devices │ SERIES: CP90H │ DESCRIPTION: PELTIER MODULE cuidevices.com 60 50 40 30 20 10 0 Input Voltage (V)Heat Pumped, Q (W) 1.8 A 3.6 A 5.4 A 9 A 7.2 A 1.8 A 3.6 A 5.4 A 7.2 A 9 A ΔT=Th-Tc (°C) 4.0 2.0 3.0 1.0 CP902015343H PERFORMANCE (Th=27°C) 60 50 40 30 20 10 0 Input Voltage (V)Heat Pumped, Q (W) 1.8 A 3.6 A 5.4 A 9 A 7.2 A 1.8 A 3.6 A 5.4 A 7.2 A 9 A ΔT=Th-Tc (°C) 4.0 2.0 3.0 1.0 CP902015343H PERFORMANCE (Th=50°C) Additional Resources: Product Page | 3D Model
date 11/12/2020 │ page 4 of 6CUI Devices │ SERIES: CP90H │ DESCRIPTION: PELTIER MODULE cuidevices.com 60 50 40 30 20 10 0 Input Voltage (V)Heat Pumped, Q (W) 1.8 A 3.6 A 5.4 A 9 A 7.2 A 1.8 A 3.6 A 5.4 A
7.2 A9 A
ΔT=Th-Tc (°C) 8.0 4.0 CP9040335H PERFORMANCE (Th=27°C) 60 50 40 30 20 10 0 Input Voltage (V)Heat Pumped, Q (W) 1.8 A 3.6 A 5.4 A 9 A 7.2 A 1.8 A 3.6 A 5.4 A 7.2 A 9 A ΔT=Th-Tc (°C) 8.0 4.0 CP9040335H PERFORMANCE (Th=50°C) Additional Resources: Product Page | 3D Model
date 11/12/2020 │ page 5 of 6CUI Devices │ SERIES: CP90H │ DESCRIPTION: PELTIER MODULE cuidevices.com 60 50 40 30 20 10 0 Input Voltage (V)Heat Pumped, Q (W) 1.8 A 3.6 A 5.4 A 9 A 7.2 A 1.8 A 3.6 A 5.4 A 7.2 A 9 A ΔT=Th-Tc (°C) CP90626257 PERFORMANCE (Th=27°C) 60 50 40 30 20 10 0 Input Voltage (V)Heat Pumped, Q (W) 1.8 A 3.6 A 5.4 A 9 A 7.2 A 1.8 A 3.6 A 5.4 A 7.2 A 9 A ΔT=Th-Tc (°C) CP90626257 PERFORMANCE (Th=50°C) Additional Resources: Product Page | 3D Model
date 11/12/2020 │ page 6 of 6CUI Devices │ SERIES: CP90H │ DESCRIPTION: PELTIER MODULE cuidevices.com CUI Devices offers a one (1) year limited warranty. Complete warranty information is listed on our website. CUI Devices reserves the right to make changes to the product at any time without notice. Information provided by CUI Devices is believed to be accurate and reliable. However, no responsibility is assumed by CUI Devices for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI Devices products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. rev. description date 1.0 initial release 10/16/2019 1.01 added models CP902015343H & CP9040335H 11/12/2020 The revision history provided is for informational purposes only and is believed to be accurate.