CLA-SERIES SKYWORKS
Document overview
- PDF pages: 9
Technical content
Page 1
DATA SHEET
CLA Series: Silicon Limiter Diodes and Ceramic Hermetic
Packaged Devices
Applications
LNA receiver protection Commercial and defense radar
Features
Established limiter diode process High power, mid-range, and cleanup designs Low insertion loss: 0.1 dB @ 10 GHz Peak power handling to +74 dBm Ultra low spike leakage power Tight control of I layer base width

Description
The Isolink CLA series of silicon limiter diodes provides passive receiver protection over a wide range of frequencies from 100 MHz to over 20 GHz. These devices use a well-established silicon technology resulting in high resistivity and tightly controlled base width PIN limiter diodes. Limiter circuits using these devices perform with strong limiting action and low loss. The CLA series consists of ten individual chip designs of different intrinsic region base widths and capacitances designed to accommodate multi-stage limiter applications. The mesa-constructed, thin base width, low capacitance CLA4601 series, CLA4602 series, CLA4604 series, and CLA4605 series
are designed for low-level and cleanup applications. The CLA4603 series, CLA4606 series, CLA4607 series, CLA4608 series and CLA4610 series are planar designs designated for high-power and mid-range applications. The CLA4609 series thick base width mesa diode is designed for coarse limiter-stage applications. The absolute maximum ratings of the CLA diode series are provided in Table 1. Electrical specifications are specified in Table 2. Typical performance characteristics are provided in Table 3 and Figures 1 through 4.
Page 2
Table 1. CLA Series Absolute Maximum Ratings1

1 Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other parameters set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device.
ESD HANDLING: Although this device is designed to be as robust as possible, electrostatic discharge (ESD) can damage this device.
This device must be protected at all times from ESD when handling or transporting. Static charges may easily produce
potentials of several kilovolts on the human body or equipment, which can discharge without detection.
Industry-standard ESD handling precautions should be used at all times.
Table 2. CLA Series Electrical Specifications1,2 (1 of 2)
| Part Number | Breakdown Voltage (V) | I Region (μm) | Total Capacitance (CT) @ 0 V (pF) | Total Capacitance (CT) @ 6 V (pF) | Series Resistance (RS) @ 10 mA (Ω) | Minority Carrier Lifetime (TL) @ 10 mA (ns) | Thermal Resistance (θ) 3 Average (°C/W) |
|---|---|---|---|---|---|---|---|
| Min to Max | Nominal | Typical | Maximum | Typical | Typical | Maximum | |
| CLA4601-203 | 15 to 30 | 1.0 | 0.37 | 0.35 | 2.0 | 5 | 150 |
| CLA4601-210 | 15 to 30 | 1.0 | 0.37 | 0.35 | 2.0 | 5 | 140 |
| CLA4601-219 | 15 to 30 | 1.0 | 0.37 | 0.35 | 2.0 | 5 | 200 |
| CLA4601-240 | 15 to 30 | 1.0 | 0.37 | 0.35 | 2.0 | 5 | 200 |
| CLA4602-203 | 15 to 30 | 1.0 | 0.45 | 0.40 | 1.5 | 5 | 110 |
| CLA4602-210 | 15 to 30 | 1.0 | 0.45 | 0.40 | 1.5 | 5 | 100 |
| CLA4602-219 | 15 to 30 | 1.0 | 0.45 | 0.35 | 1.5 | 5 | 160 |
| CLA4602-240 | 15 to 30 | 1.0 | 0.45 | 0.40 | 1.5 | 5 | 160 |
| CLA4603-203 | 20 to 45 | 1.5 | 0.45 | 0.35 | 1.5 | 5 | 130 |
| CLA4603-210 | 20 to 45 | 1.5 | 0.45 | 0.40 | 1.5 | 5 | 120 |
| CLA4603-219 | 20 to 45 | 1.5 | 0.45 | 0.40 | 1.5 | 5 | 180 |
| CLA4603-240 | 20 to 45 | 1.5 | 0.45 | 0.35 | 1.5 | 5 | 180 |
| CLA4604-203 | 30 to 60 | 2.0 | 0.37 | 0.30 | 2.0 | 7 | 130 |
| CLA4604-210 | 30 to 60 | 2.0 | 0.37 | 0.35 | 2.0 | 7 | 120 |
| CLA4604-219 | 30 to 60 | 2.0 | 0.37 | 0.30 | 2.0 | 7 | 160 |
| CLA4604-240 | 30 to 60 | 2.0 | 0.37 | 0.30 | 2.0 | 7 | 180 |
Page 3
Table 2. CLA Series Electrical Specifications1,2 (2 of 2)
| Part Number | Breakdown Voltage (V) | I Region (μm) | Total Capacitance (CT) @ 0 V (pF) | Total Capacitance (CT) @ 6 V (pF) | Series Resistance (RS) @ 10 mA (Ω) | Minority Carrier Lifetime (TL) @ 10 mA (ns) | Thermal Resistance (θ)3 Average (°C/W) |
|---|---|---|---|---|---|---|---|
| Min to Max | Nominal | Typical | Maximum | Typical | Typical | Maximum | |
| CLA4605-203 | 30 to 60 | 2.0 | 0.45 | 0.30 | 1.5 | 7 | 100 |
| CLA4605-210 | 30 to 60 | 2.0 | 0.45 | 0.40 | 1.5 | 7 | 90 |
| CLA4605-219 | 30 to 60 | 2.0 | 0.45 | 0.40 | 1.5 | 7 | 150 |
| CLA4605-240 | 30 to 60 | 2.0 | 0.45 | 0.35 | 1.5 | 7 | 150 |
| CLA4606-203 | 45 to 75 | 2.5 | 0.45 | 0.35 | 1.5 | 10 | 110 |
| CLA4606-210 | 45 to 75 | 2.5 | 0.45 | 0.40 | 1.5 | 10 | 100 |
| CLA4606-219 | 45 to 75 | 2.5 | 0.45 | 0.40 | 1.5 | 10 | 160 |
| CLA4606-240 | 45 to 75 | 2.5 | 0.45 | 0.35 | 1.5 | 10 | 106 |
| CLA4607-203 | 120 to 180 | 7.0 | 0.45 | 0.35 @ 38 V | 1.5 | 50 | 70 |
| CLA4607-210 | 120 to 180 | 7.0 | 0.45 | 0.40 @ 38 V | 1.5 | 50 | 60 |
| CLA4607-219 | 120 to 180 | 7.0 | 0.45 | 0.40 @ 38 V | 1.5 | 50 | 120 |
| CLA4607-240 | 120 to 180 | 7.0 | 0.45 | 0.35 @ 38 V | 1.5 | 50 | 120 |
| CLA4608-203 | 120 to 180 | 7.0 | 0.85 | 0.75 @ 38 V | 0.5 | 100 | 45 |
| CLA4608-210 | 120 to 180 | 7.0 | 0.85 | 0.75 @ 38 V | 0.5 | 100 | 35 |
| CLA4608-219 | 120 to 180 | 7.0 | 0.85 | 0.70 @ 38 V | 0.5 | 100 | 100 |
| CLA4608-240 | 120 to 180 | 7.0 | 0.85 | 0.70 @ 38 V | 0.5 | 100 | 100 |
| CLA4609-203 | 250 (Min) | 20.0 | 0.51 | 0.40 | 1.0 | 1175 | 45 |
| CLA4609-210 | 250 (Min) | 20.0 | 0.51 | 0.45 | 1.0 | 1175 | 35 |
| CLA4609-219 | 250 (Min) | 20.0 | 0.51 | 0.40 | 1.0 | 1175 | 100 |
| CLA4609-240 | 250 (Min) | 20.0 | 0.51 | 0.40 | 1.0 | 1175 | 100 |
| CLA4610-203 | 80 to 120 | 4.5 | 0.38 | 0.40 | 1.7 | 20 | 182 |
| CLA4610-210 | 80 to 120 | 4.5 | 0.38 | 0.45 | 1.7 | 20 | 81 |
| CLA4610-219 | 80 to 120 | 4.5 | 0.38 | 0.40 | 1.7 | 20 | 152 |
| CLA4610-240 | 80 to 120 | 4.5 | 0.38 | 0.40 | 1.7 | 20 | 163 |
1 Performance is guaranteed only under the conditions listed in this table and is not guaranteed over the full operating or storage temperature ranges. Operation at elevated temperatures may reduce reliability of the device. 2 TOP = +25 C, CJ measured at 1 MHz, RS measured at 500 MHz, CW thermal resistance for infinite heat sink, unless otherwise noted. 3 Thermal resistance is calculated from the measured power dissipation @ f = 2.6 GHz, TJ max = 175 C and TCASE = 85 C
Page 4
Table 3. Typical Performance @ 25 °C @ 2.6 GHz, Z0 = 50 Ω1
| Part Number | Insertion Loss @ –10 dBm (dB) | CW Input Power for 1 dB Insertion Loss (dBm) | Maximum CW Input Power (dBm) | Maximum Pulsed Input Power (dBm) 2 | Output @ Maximum Pulsed Input (dBm) 2 | Recovery Time (ns) 3 | Spike Leakage (ergs) 4 |
|---|---|---|---|---|---|---|---|
| CLA4601 | 0.1 | 12 | 36 | 65 | 21 | 5 | Note 5 |
| CLA4602 | 0.1 | 12 | 36 | 65 | 24 | 5 | Note 5 |
| CLA4603 | 0.1 | 10 | 38 | 67 | 22 | 5 | Note 5 |
| CLA4604 | 0.1 | 11 | 40 | 70 | 24 | 5 | Note 5 |
| CLA4605 | 0.1 | 12 | 40 | 70 | 27 | 5 | 0.08 |
| CLA4606 | 0.1 | 14 | 41 | 71 | 27 | 5 | 0.03 |
| CLA4607 | 0.1 | 26 | 43 | 73 | 39 | 5 | 0.21 |
| CLA4608 | 0.2 | 26 | 43 | 73 | 44 | 5 | 0.15 |
| CLA4609 | 0.3 | 37 | 44 | 74 | 50 | 5 | 25.77 |
| CLA4610 | 0.1 | 24 | 40 | 57 | 32 | 5 | Note 5 |
1 Diode chip is mounted on a 0.5 oz Cu PC board using 1 to 2 mils of conductive epoxy. Bond wire connections are made with 0.8 mil Au wire. Limiter configured with shunt connected diode and 22 nH ground return and 100 pF DC blocking capacitors. 2 Pulsed power measurements taken at 1 μs pulse width, @ f = 10 KHz, and 0.1% duty cycle. 3 Recovery time represents the transition time from the high-loss state to the low-loss state following the removal of a high-power input. It is defined as the time from the end of the highpower pulse to the time when insertion loss has returned to within 3 dB of the quiescent (low-power) state. 4 Spike Leakage (ergs) = ts x Ps x 107 where ts is the spike width at the half-power point (in seconds) and PS is the maximum spike amplitude in watts.
5 Not detectable under current test conditions described in Note 2.
Page 5
Typical Performance Characteristics
(Tested at 25 °C, Board and Connector Loss Are Not De-Embedded)

Figure 1. CLA4601 to CLA4606 CW Output vs Input Power

0 5 10 15 20 25 30 35 40 45
Power In (dBm)
Figure 3. LCA4601 to CLA4606 Insertion Loss vs CW Input Power

Input Power (dBm)
Figure 2. CLA4607 to CLA4610 CW Output vs Input Power

45
Power In (dBm)
Figure 4. CLA4607 to CLA4610 Insertion Loss vs CW Input Power
Page 6
Technical Description
The limiter can be used in various configurations to meet different application requirements. For example, in low-to- medium power applications, a single-stage limiter can be used.
In this case, an inductor must be used in parallel with the limiter to create a DC return choke.
A dual-stage limiter design can handle much higher power. The first stage works as the coarse stage (CLA4607 through
Package Outline Drawings
CLA4610), and the second stage works as the cleanup stage (CLA4601 through CLA4606).
Package dimension drawings are provided in Figures 5 through 8.
For detailed application information, refer to the Skyworks Application Note: PIN Limiter Diodes in Receiver Protectors at
www.skyworksinc.com.

Schematic N-Type 1
2
0.055 (1.40 mm) 0.051 (1.30 mm) Dia.
Dimensions are in inches (millimeters shown in parentheses)
203235-005
Figure 5. -203 Package
Schematic 1
0.064 (1.63 mm)
0.124 (3.15 mm) 0.119 (3.02 mm) Dia.
0.060 (1.52 mm)

Dimensions are in inches (millimeters shown in parentheses)
203235-006
Figure 6. -210 Package
Page 7

Version A
Schematic
1
0.075 (1.91 mm) 0.065 (1.65 mm) Sq.
Cathode
0.033 (0.84 mm) Min.
1 2
0.010 (0.25 mm) Ref.

2
0.020 (0.51 mm) Typ.
0.045 (1.14 mm) 0.030 (0.76 mm)
Dimensions are in inches (millimeters shown in parentheses)
Version B
203235-007
Figure 7. -219 Package
Isolink, Inc. • Phone [408] 946-1968 • Fax [408] 946-1960 • hirel.sales@skyworksinc.com • www.skyworksinc.com
Page 8
Schematic
2
1
Colored Dot Denotes Cathode

0.104 (2.64 mm) 0.092 (2.34 mm)

0.005 (0.127 mm) 0.003 (0.076 mm)
0.028 (0.71 mm)
Dimensions are in inches (millimeters shown in parentheses)
203235-008
Figure 8. -240 Package
Page 9
Copyright © 2014, 2017 Isolink, Inc. All Rights Reserved.
Information in this document is provided in connection with Isolink, Inc. (“Isolink”), a wholly-owned subsidiary of Skyworks Solutions, Inc. These materials, including the information contained herein, are provided by Isolink as a service to its customers and may be used for informational purposes only by the customer. Isolink assumes no responsibility for errors or omissions in these materials or the information contained herein. Isolink may change its documentation, products, services, specifications or product descriptions at any time, without notice. Isolink makes no commitment to update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes.
No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Isolink assumes no liability for any materials, products or information provided hereunder, including the sale, distribution, reproduction or use of Isolink products, information or materials, except as may be provided in Isolink Terms and Conditions of Sale.
THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY DISCLAIMED. ISOLINK DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. ISOLINK SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST
REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
Customers are responsible for their products and applications using Isolink products, which may deviate from published specifications as a result of design defects, errors, or operation of products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Isolink assumes no liability for applications assistance, customer product design, or damage to any equipment resulting from the use of Isolink products outside of stated published specifications or parameters.
Isolink is a trademark of Isolink Inc. in the United States and other countries. Skyworks and the Skyworks symbol are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands and names are for identification purposes only, and are the property of their respective owners.
Isolink, Inc. • Phone [408] 946-1968 • Fax [408] 946-1960 • hirel.sales@skyworksinc.com • www.skyworksinc.com