The Liquiline Control CDC90 automates the cleaning and calibration of Memosens pH and ORP measuring points in all industries. Your benefits
- Optimized cleaning and calibration cycles guarantee reliable and reproducible measuring signals that help to improve product yield, quality and raw material consumption.
- Optimized cleaning and calibration cycles, particularly in the event of sensor fouling and clogging, ensure reliable measured values and therefore guarantee your product safety.
- Liquiline Control CDC90 minimizes maintenance and repair activities in environments that are hazardous and difficult to access. This increases workplace safety for your service staff.
- Seamless integration of system into your process control system thanks to certified communication standards such as analog signals (0/4 to 20 mA), PROFIBUS DP, Modbus TCP, EtherNet/IP, Profinet, including web server technology. Products Solutions Services Technical Information Liquiline Control CDC90 The smart system for automated measuring points TI01340C/07/EN/05.22-00 71561674 2022-03-04
2 Endress+Hauser
Digital sensor inputs, passive in the CDC90 control unit ... 11
Function and system design Measuring principle The Liquiline Control CDC90 automates the cleaning and calibration of Memosens pH and ORP measuring points in all industries. It automatically cleans, calibrates, monitors and verifies up to two sensors, thereby reducing maintenance costs, improving workplace safety in hazardous environments and boosting product output and quality. Liquiline Control CDC90 can be easily integrated into existing plant infrastructures and enables the practical remote operation of your measuring points via the control station. Measuring system A complete measuring system comprises the following components:
- Liquiline Control CDC90
- Retractable assembly (e.g. Cleanfit series)
- pH/ORP sensor
- Lines for compressed air, water and electrics
- Digital measuring cable A0035661 1 Example of a complete measuring system
1 Water connection, at installation location 7 CDC90 control unit
2 Retractable assembly (e.g. Cleanfit series) with inductive limit switches with pH/ORP sensor
8 Ethernet switch
3 Process/medium 9 Media (cleaners, buffers)
4 Rinsing block 10 Compressed air line
5 Pump canister unit 11 Electric cable, signal cable
6 Pneumatic control unit
The system is available in different versions. Here is a complete overview comprising all of the system's modules.
4 Endress+Hauser
2 Overview of CDC90
1 CDC90 control unit 5 Canister for buffer solutions and
2 Mounting plate 6 Canister holder
3 Ethernet switch 7 Float switch
4 Pneumatic control unit 8 Pumps
You can choose from the following cleaning and calibration options: Predefined program for:
- Cleaning the sensor
- Cleaning and calibrating the sensor
- Assembly retraction in measuring and service position
- User-definable programs without predefined program steps You can freely configure all programs to suit your requirements. The predefined programs are used for faster configuration. Calibration and measurement Calibration options for pH glass, ISFET and ORP sensors:
- Single-point or two-point calibration The buffer tables e.g. according to DIN, Endress+Hauser etc. are saved by setting the buffers used and automatically calculating the pH values depending on the temperature.
- Automatic acceptance of calibration data for digital sensors with Memosens technology Equipment architecture Inputs and outputs The CDC90 control unit consists of a Liquiline transmitter and a separate industrial PC (IPC). The Liquiline transmitter acts as the peripheral interface for analog and digital signals. These are controlled by an IPC that has a separate software program for the automation of the measuring point.
The IPC is responsible for retracting the assembly and activating the pilot valve manifold, and processes all the states of the float switches and pressure switches. The IPC only establishes digital fieldbus communication to the control station. In both the IPC and the Liquiline transmitter, operation and configuration is possible via the device's web server. Primary operation is via the IPC. As the Liquiline transmitter is preconfigured upon delivery, it generally does not require any further configuration. The assignment of the inputs and outputs is provided in the following table and graphic: Liquiline transmitter IPC Pneumatic control unit Inputs Digital 12x0/24 VDC, passive Analog 1 x 0/4 to 20 mA, passive, potentially isolated from one another and from the sensor inputs Outputs Digital 16x0/24 VDC, 0.5 mA per output Analog 1 or 5 x 0/4 to 20 mA, active, galvanically isolated from each other and from the sensor circuits Fieldbuses • EtherNet/IP via Modbus TCP/ EtherNet/IP coupler
- PROFIBUS DP via Modbus TCP/Profibus DP coupler
- PROFINET via Modbus TCP/PROFINET coupler
- Modbus TCP
6 Endress+Hauser
3 Overview of analog and digital communication
1 Housing of the CDC90 control unit
2 BASE2-E module
3 IPC
4 EtherCAT connection between Ethernet switch and pneumatic control unit (W20-W21-W22)
5 Ethernet switch
6 Connection to PCS
7 Modbus TCP connection between Ethernet switch and BASE2-E (W19-W24)
8 Modbus TCP connection between Ethernet switch and IPC (W18-W23)
9 Pilot valves
10 Pneumatic control unit
11 External remote IO, DIO
Modules:
- Slot 1: base module BASE2-E (contains 2 sensor inputs, 2 current outputs)
- Slot 2-3: empty
- Slot 4: module 2AI (2 current inputs)
- Slot 5-6: 2x module DIO
- Slot 7: retrofittable: module 4AO (4 current outputs) Example of terminal name:
4 Example of port assignment Basic rule for hardware upgrades Please note the following if upgrading the device:
- Upgrade only to 1x 4 AO module possible
- A maximum of two "DIO" modules may be used. IPC ports Connection to Ethernet switch. A0036047 5 IPC ports
1 Connection to Ethernet switch
2 Supply voltage
8 Endress+Hauser
6 Pneumatic control unit for one measuring point 1 100 / 230 VAC terminal 8 Pilot valves 2 +24 V terminal 9 Mounting 3 0 V terminal 10 Cable gland
4 Terminals for float switches and pressure switches 11 24 VDC power unit
5 Output interface terminal for assemblies, limit position
12 F1 system fuse
6 Pressure switch 13 Pilot valve manifold, bus node
7 External remote IO, DIO 14 Ventilation slot
7 Pneumatic control unit for a 2nd measuring point
1 Extension of the output interface terminals for a 2nd measuring point
2 Extension of the pilot valves for a 2nd measuring point
8 Rinsing block
1 Water connection (hose barb D12 PP) 5 Multihose connection
2 Liquid canister 1 6 Liquid canister 2
3 Liquid canister 3 7 Air rinsing block (pilot valve 4)
4 Outlet rinse connection to assembly
A changeover valve is used in conjunction with the rinsing block for a second measuring point.
10 Endress+Hauser
Several digital communication protocols are available to enable the Liquiline Control CDC90 to be integrated into a customer's digital infrastructure (process control system). The data connection is established and managed exclusively via the internal controller of the CDC90, and not via the fieldbus module of the integrated Liquiline transmitter. Additional Special Documentation is available for the integration process. However, if analog signals are used (current inputs/outputs), the current input and output modules of the Liquiline transmitter act as the interface to the customer's control system / PCS. Output 1:2 on the base module and input 4:2 on the AI module are preconfigured. Only the current outputs on the 4 AO module need to be configured for measured value transmission. Liquiline Control CDC90 has an internal communication process via Modbus, which is designed exclusively to ensure safe and reliable processing and the trouble-free operation of the device. These communication processes are not designed for external communication with the customer. Therefore, with the exception of the Liquiline transmitter's web server functionality, do not connect the interfaces of the transmitter to other interfaces. You can choose from the following communication options in the CDC90 control unit:
- Analog current output, current signals (4 to 20 mA) Via AO modules in the CDC90 control unit. The settings can be made via the web server or local display. Power transmission is via the current input/output modules of the CDC90 control unit. The input/ outputs are already preconfigured.
- EtherNet/IP (adapter)
- PROFIBUS DP (slave)
- Modbus TCP (server)
- PROFINET (device) More detailed information on fieldbus communication is provided on the product pages on the Internet:
- EtherNet/IP (adapter) via Modbus TCP - EtherNet/IP gateway: BA02241C
- Modbus TCP (server): BA02238C
- PROFIBUS DP (slave) via Modbus TCP - PROFIBUS DP gateway. BA02239C
- PROFINET (device) via Modbus TCP - PROFINET gateway: BA02240C Dependability Reliability
- Level and consumption indicator The level and amount of buffer or cleaning solution are displayed.
- Information about the current program step Transparent status indication with time information
- Sensor verification Sensor accuracy is verified. If a tolerance range is exceeded during calibration, Liquiline Control rejects the calibration values. Therefore you are guaranteed that your measured value is always accurate.
- Seal condition monitoring Monitoring of the seals on the assembly, pumps, water valve and additional valves. With this function, the system can predict when the assembly will require new sealing rings.
- System pressure monitoring to activate the assembly and pumps. If the pressure drops below the minimum level, the system signals an alarm. Memosens MEMO SENS Memosens makes your measuring point safer and more reliable:
- Non-contact, digital signal transmission enables optimum galvanic isolation
- Completely watertight
- Sensor can be calibrated in a lab, thus increasing the availability of the measuring point in the process
- Maintenance thanks to recording of sensor data, e.g.: Total hours of operation Input Measured variables → Documentation of the connected sensor
Measuring ranges → Documentation of the connected sensor Types of input • Digital sensor inputs for sensors with Memosens protocol (Base-E module in the CDC90 control unit )
- Digital inputs (DIO module in the CDC90 control unit)
- Digital inputs, Namur (pneumatic control unit)
- Analog inputs (AI module in the CDC90 control unit) Input signal Depending on version:
- Max. 2 x binary sensor signal
- Standard: 2 x 0/4 to 20 mA
- 0 to 30 V DC Digital sensor inputs, passive in the CDC90 control unit Span > 0 to 20 mA Signal characteristic Linear Internal resistance Non-linear Test voltage 500 V Digital inputs, passive in the CDC90 control unit Electrical specification
- drawing power (passive)
- Galvanically isolated Span
- High: 11 to 30 V DC
- Low: 0 to 5 V DC Nominal input current max. 8 mA PFM function Minimum pulse width: 500 µs (1 kHz) Test voltage 500 V Cable specification Max. 2.5 mm2 (14 AWG) Digital inputs, passive in pneumatic control unit Span
- High: 11 to 30 V DC
- Low: 0 to 5 V DC Nominal input current max. 8 mA Cable specification Max. 2.5 mm2 (14 AWG)
12 Endress+Hauser
Analog inputs, passive in CDC90 control unit Span > 0 to 20 mA Signal characteristic Linear Internal resistance Non-linear
Output signal • Analog outputs, on the Base-E module, active in the CDC90 control unit
- Digital outputs, on the External Remote IO, DIO, active in the pneumatic control unit Analog outputs, active in CDC90 control unit Signal on alarm Adjustable, as per NAMUR Recommendation NE 43
- In measuring range 0 to 20 mA: failure current from 20 to 23 mA
- In measuring range 4 to 20 mA: failure current from 2.4 to 23 mA
- Factory setting for failure current for both measuring ranges: 22.5 mA The failure current of 22.5 mA represents "Failure-category" alarms of the transmitter. More detailed information is available in the Operating Instructions for the transmitter. In addition, a failure current of 10 mA represents "Failure-category" alarms of the overall system. More detailed information is available in the Special Documentation on Analog Communication. SD02527C Load Max. 500 Ω Linearization/transmission behavior Linear Electrical specification
- Passive
- Open collector, max. 30 V, 15 mA
- Maximum voltage drop 3 V PFM function Minimum pulse width: 500 µs (1 kHz) Digital outputs, active in pneumatic control unit Electrical specification
- Outputs:16
- Max. current: 0.5 A per output
- Total current: max. 8A Cable specification Max. 2.5 mm2 (14 AWG) Protocol-specific data IPC output signals Modbus TCP EtherNet/IP (via gateway) PROFIBUS DP (via gateway) PROFINET (via gateway) Signal encoding IEEE 802.3 (Ethernet) IEEE 802.3 (Ethernet) PROFIBUS-DP- compliant as per IEC 61158 IEEE 802.3 (Ethernet), IEC 61131-3-Code Data transmission rate 10 / 100 Mbit/s 10 / 100 Mbit/s 9.6 kBit/s - 12 MBit/s autodetect 10 / 100 Mbit/s Galvanic isolation Yes Yes Yes Yes Connection M12 See gateway See gateway See gateway Address 77
14 Endress+Hauser
The device uses an EtherCat connection for internal communication. Depending on the network load, EtherCAT may cause failures in the CDC90 IPCs if multiple CDC90 devices are integrated in the same network. ‣ To reduce the network load in the case of a Modbus TCP connection, the networks must be separated. Physical separation with a VLAN-enabled switch, e.g. Layer 2 managed switch, or software-based separation is possible. TCP port 502 TCP connections 3 Log TCP Function codes 03, 04, 06, 08, 16, 23 Broadcast support for function codes 06, 16, 23 Supported features Address can be configured using DHCP or software IO data Input (T → O) Program control
- Output (O → T)
- System Information
- Measured values and status
- IO Feedback
- Program feedback
- Status signals
- Measured values
- Sensor calibration Web server The Liquiline Control's IPC features a web server that allows users to configure the device, visualize measured values and check the status of the entire system. The web server of the CDC90 control unit enables the direct configuration of the connected sensor and peripheral modules for digital/analog inputs and outputs. The two web servers can be accessed via separate IP addresses. Liquiline transmitter TCP port 80 Supported features • Remote-controlled device configuration
- Save/restore device configuration (via SD card)
- Export as SQLite database
- Access to web server via Internet browser IPC TCP port 8080 Supported features • Remote-controlled device configuration
- Access to web server via Internet browser
Supply voltage 100 to 230 V AC Frequency 50/60 Hz Power consumption Max. 50 VA Cable specification Power supply cable (mains) Cable cross-section:
- Minimum cross-section 3 x 0.75 mm² to 10 m length
- Minimum cross-section 3 x 1.5 mm² to 20 m length Overvoltage protection Integrated overvoltage protection according to EN 61326 Protection category 1 and 3 Electrical connection Electrical safety IEC 61010-1, Class I equipment Low voltage: overvoltage category II Environment < 2000 m (< 6562 ft) above MSL
16 Endress+Hauser
Performance characteristics Response time Current outputs t90 = max. 500 ms for an increase from 0 to 20 mA Current inputs t90 = max. 330 ms for an increase from 0 to 20 mA Digital inputs and outputs t90 = max. 330 ms for an increase from low to high Reference temperature 25 °C (77 °F) Measured error for sensor inputs → Documentation of the connected sensor Measured error for current inputs and outputs Typical measured errors: < 20 µA (with current values < 4 mA) < 50 µA (with current values 4 to 20 mA) at 25 ˚C (77˚ F) each Additional measured error depending on the temperature: < 1.5 µA/K Frequency tolerance of digital inputs and outputs ≤ 1% Resolution of current inputs and outputs < 5 µA Repeatability → Documentation of the connected sensor Environment This device is for indoor use only. Ambient temperature range 0 to 45˚C (32 to 113˚F) Storage temperature –20 to 70 °C (–4 to 158 °F) Relative humidity 10 to 90 %, non-condensating Operating height Max. altitude above MSL < 2000 m (< 6562 ft) above MSL Degree of protection CDC90 control unit IP66/Type 4X Pneumatic control unit IP54/Type 12 Climate class As per IEC 60654-1: B2 Electromagnetic compatibility Interference emission and interference immunity as per EN 61326-1:2013, Class A for Industry Pollution degree The product is suitable for pollution degree 2.
Dimensions Dimensions of CDC90 control unit H 5 6 7 8 I GFEDC A 1 2 3 4 B 162 (6.38) 14 (0.55) Ø4 (0.16) Ø9 (0.35) 237 (9.33) 194 (7.64) 76 (2.99) 95 (3.74) A0012396 9 Dimensions of field housing in mm (in) Dimensions of pneumatic control unit 210 (8.27) 380 (15.0) 300 (11.82) A0031929 10 Dimensions of pneumatic control unit in mm (in)
18 Endress+Hauser
Dimensions of canister holder 220 (8.66) 470 (18.50) 300 (11.82) 8.5 (0.33)Ø A0033139 11 Dimensions of canister holder in mm (in) 369.5 (14.55) 65 (2.56) 140 (5.51) A0032277 12 Dimensions of canister with pump in mm (in)
Dimensions of rinsing block 195 (7.68) 240 (9.45) 120 (4.72) 120 (4.72) 108 (4.25) 181 (7.13) 223.5 (8.80) Ø 5,5 (0.22) Ø 5,5 (0.22) A0032267 13 Dimensions of rinsing block PVDF, in mm (in) 222.5 (8.76)Ø 6,4 (0.25) A0033402 14 Dimensions of changeover valve, 2nd measuring point in mm (in)
20 Endress+Hauser
Dimensions of mounting plate 150 (6.00) 380 (15.00) 1170 (46.06) 50 (1.97) 80 (3.15) 45 (1.77) 20 (0.79) 20 (0.79) /UNI23008 (0.31) A0031946 15 Dimensions of mounting plate in mm (in) Weight Device Weight Complete device on mounting plate Approx. 52 kg (114.64 lbs) CDC90 control unit Approx. 2.1 kg (4.63 lbs) depending on the version Pneumatic control unit painted 7.5 kg (16.53 lbs) (empty) Pump canister unit Approx. 1.5 kg (3.30 lbs) Mounting plate (Trespa) Approx. 10 kg (22 lbs) Canister shelf Approx. 3.2 kg (7.05 lbs) SD card Max. 5 g (0.17 oz) Materials Device Material CDC90 control unit Module housing PC (polycarbonate) Soft keys TPE (thermoplastic elastomers) LED POM Cable mounting rail Stainless steel 1.4301 (AISI 304) Display glass Plastic capacitive touchscreen Cable glands PA (polyamide) V0 as per UL94 M12 cable glands PA (polyamide) Housing seals EPDM Cable gland O-ring EPDM
Housing Stainless steel 1.4301 (AISI 304), painted steel Housing seals EPDM (ethylene propylene diene rubber) Cable glands PA (polyamide) V0 as per UL94 Housing seals EPDM Pump canister unit Pump PVDF+CF/PP/NBR+PTFE/PTFE/PP Canister PE Float switch PVC/EPDM/PE Canister fitting ABS/PMMA Bracket M5 L110*B40 W8 PP O-ring EPDM Coupling DMG/8*6 1/4 PVDF Canister shelf PP Rinsing block Process valve EPDM/PP/stainless steel:1.4408/PTFE Rinsing body PVDF/1.4401 Rinse connection PP Check valves PVDF+FKM/PVDF+FFKM/1.4571+FKM Bracket, metal plate 1.4571 Bracket, clamp 1.4404 Hose bracket/cable gland PA Sealing plug Teflon Double nipple PVDF O-ring FKM/FFKM Hoses Compressed air PUN-A Liquid PUN-A+/PTFE Hose specification Medium hoses Max. 6 bar (87 psi) Compressed air hoses Pressure ratings of pilot valve manifold: Max. 10 bar (145 psi) Pressure switch: Max. 12 bar (174 psi) Pump Vacuum pump: Max. 8 bar (116 psi)( (8 bar corresponds to 8 l/min delivery rate, depending on the control air) Pipes: Max. 10 bar (145 psi) Connections Water connection Size Water connection, rinsing block Hose barb D12 PP for hoses with internal diameter 12 mm (0.47 in) Assembly inlet and outlet Hose coupling D6/8 mm (0.24/0.31 in) PVDF
22 Endress+Hauser
Medium ID 6 mm (0.24 in)/ OD 8 mm (0.31 in) Compressed air Compressed air supply, purge air: ID 6 mm (0.24 in)/ OD 8 mm (0.31 in) Compressed air of assemblies, valves, pumps: ID 4 mm (0.16 in)/ OD 6 mm (0.24 in)
16 Touchscreen display The CDC90 can be operated via a touchscreen display. Soft keys are also available for program operation. Menu overview 2 3 4 A0033714 Item Function
1 Time
2 Display and fast access to the most important error message
3 Display and navigation to measuring point 1 and display of pH value or ORP value in mV
4 For one measuring point: second measured value of measuring point 1 and temperature value
For two measuring points: display and navigation to measuring point 2 and display of pH value or ORP value in mV
5 User profile display and log-in
6 Operating mode
7 Overview of main menu
8 Navigation
24 Endress+Hauser
Certificates and approvals Current certificates and approvals that are available for the product can be selected via the Product Configurator at www.endress.com: 1. Select the product using the filters and search field. 2. Open the product page. 3. Select Configuration.
Ordering information
Product page www.endress.com/cdc90 Product Configurator 1. Configure: Click this button on the product page. 2. Select Extended selection. The Configurator opens in a separate window. 3. Configure the device according to your requirements by selecting the desired option for each feature. In this way, you receive a valid and complete order code for the device. 4. Apply: Add the configured product to the shopping cart. For many products, you also have the option of downloading CAD or 2D drawings of the selected product version. 5. Show details: Open this tab for the product in the shopping cart. The link to the CAD drawing is displayed. If selected, the 3D display format is displayed along with the option to download various formats. Scope of delivery The scope of delivery comprises:
- 1 CDC90 control unit in the version ordered
- 1 pneumatic control unit
- Up to 3 pumps for supplying cleaner and buffer with canisters
- Up to 3 float switches, complete with cable to canisters
- 1 rinsing block with bracket for mounting on the process assembly
- 2 hose packages for compressed air and liquid; 3 hose packages if there is more than one measuring point
- 1 x Brief Operating Instructions (hard copy)
- Conduit adapter G 1/4" for hose 6/8 mm (ID/OD) for the assembly rinse connections: x 2 for 1 measuring point/ x 4 for 2 measuring points
- USB stick
- In the case of 2 measuring points: 1 changeover valve to control the supply of medium to the two assemblies The assemblies are pre-assembled on a mounting plate and pre-wired. Accessories The following are the most important accessories available at the time this documentation was issued. ‣ For accessories not listed here, please contact your Service or Sales Center. Assemblies Cleanfit CPA472D
- Robust retractable assembly for pH, ORP and other industrial sensors
- Heavy-duty version made of durable materials
- For manual or pneumatic, remote-controlled operation
- Product Configurator on the product page: www.endress.com/cpa472d Technical Information TI00403C Cleanfit CPA473
- Stainless steel process retractable assembly with ball valve shutoff for particularly reliable separation of the medium from the environment
- Product Configurator on the product page: www.endress.com/cpa473 Technical Information TI00344C
26 Endress+Hauser
- Plastic process retractable assembly with ball valve shutoff for particularly reliable separation of the medium from the environment
- Product Configurator on the product page: www.endress.com/cpa474 Technical Information TI00345C Cleanfit CPA871
- Flexible process retractable assembly for water, wastewater and the chemical industry
- For applications with standard sensors with 12 mm diameter
- Product Configurator on the product page: www.endress.com/cpa871 Technical Information TI01191C Cleanfit CPA875
- Retractable process assembly for sterile and hygienic applications
- For in-line measurement with standard sensors with 12 mm diameter, e.g. for pH, ORP, oxygen
- Product Configurator on the product page: www.endress.com/cpa875 Technical Information TI01168C Sensors Glass electrodes Memosens CPS11E
- pH sensor for standard applications in process and environmental engineering
- Digital with Memosens 2.0 technology
- Product Configurator on the product page: www.endress.com/cps11e Technical Information TI01493C Orbisint CPS11D
- pH sensor for process technology
- With dirt-repellent PTFE diaphragm Technical Information TI00028C Memosens CPS31E
- pH sensor for standard applications in drinking water and swimming pool water
- Digital with Memosens 2.0 technology
- Product Configurator on the product page: www.endress.com/cps31e Technical Information TI01574C Memosens CPS31D
- pH electrode with gel-filled reference system with ceramic diaphragm
- Product Configurator on the product page: www.endress.com/cps31d Technical Information TI00030C Ceraliquid CPS41D pH electrode with ceramic junction and KCl liquid electrolyte Technical Information TI00079C Memosens CPS71E
- pH sensor for chemical process applications
- With ion trap for poison-resistant reference
- Digital with Memosens 2.0 technology
- Product Configurator on the product page: www.endress.com/cps71e Technical Information TI01496C Ceragel CPS71D pH electrode with reference system including ion trap Technical Information TI00245C
- pH electrode for bio-fermenters with digital Memosens technology
- Product Configurator on the product page: www.endress.com/cps171d Technical Information TI01254C Memosens CPS91E
- pH sensor for heavily polluted media
- Digital with Memosens 2.0 technology
- Product Configurator on the product page: www.endress.com/cps91e Technical Information TI01497C Orbipore CPS91D pH electrode with open aperture for media with high dirt load Technical Information TI00375C ORP sensors Memosens CPS12E
- ORP sensor for standard applications in process and environmental engineering
- Digital with Memosens 2.0 technology
- Product Configurator on the product page: www.endress.com/cps12e Technical Information TI01494C Memosens CPS42E
- ORP sensor for process technology
- Digital with Memosens 2.0 technology
- Product Configurator on the product page: www.endress.com/cps42e Technical Information TI01575C Orbisint CPS12D ORP sensor for process technology Technical Information TI00367C Ceraliquid CPS42D ORP electrode with ceramic junction and KCl liquid electrolyte Technical Information TI00373C Memosens CPS72E
- ORP sensor for chemical process applications
- Digital with Memosens 2.0 technology
- Product Configurator on the product page: www.endress.com/cps72e Technical Information TI01576C Ceragel CPS72D ORP electrode with reference system including ion trap Technical Information TI00374C Memosens CPS92E
- ORP sensor for use in heavily polluted media
- Digital with Memosens 2.0 technology
- Product Configurator on the product page: www.endress.com/cps92e Technical Information TI01577C Orbipore CPS92D ORP electrode with open aperture for media with high dirt load Technical Information TI00435C
28 Endress+Hauser
- Sterilizable and autoclavable ISFET sensor for pH measurement
- Refillable KCI liquid electrolyte
- Product Configurator on the product page: www.endress.com/cps47d Technical Information TI01412C Memosens CPS77E
- Sterilizable and autoclavable ISFET sensor for pH measurement
- Digital with Memosens 2.0 technology
- Product Configurator on the product page: www.endress.com/cps77e Technical Information TI01396 Memosens CPS77D
- Sterilizable and autoclavable ISFET sensor for pH measurement
- Product Configurator on the product page: www.endress.com/cps77d Technical Information TI01396 Memosens CPS97D
- ISFET sensor for pH measurement with long-term stability in media with high dirt loads
- Product Configurator on the product page: www.endress.com/cps97d Technical Information TI01405C Tophit CPS441D
- Sterilizable ISFET sensor for low-conductivity media
- Liquid KCl electrolyte Technical Information TI00352C Tophit CPS471D
- Sterilizable and autoclavable ISFET sensor for food and pharmaceutics, process engineering
- Water treatment and biotechnology Technical Information TI00283C Tophit CPS491D ISFET sensor with open aperture for media with high dirt load Technical Information TI00377C Combined sensors Memosens CPS16D
- Combined pH/ORP sensor for process technology
- With dirt-repellent PTFE diaphragm
- With Memosens technology
- Product Configurator on the product page: www.endress.com/cps16D Technical Information TI00503C Memosens CPS76D
- Combined pH/ORP sensor for process technology
- Hygienic and sterile applications
- With Memosens technology
- Product Configurator on the product page: www.endress.com/cps76d Technical Information TI00506C Memosens CPS96D
- Combined pH/ORP sensor for chemical processes
- With poison-resistant reference with ion trap
- With Memosens technology
- Product Configurator on the product page: www.endress.com/cps96d Technical Information TI00507C
Additional functionality Hardware extension modules Kit, extension module DIO
- 2 x digital input
- 2 x digital output
- Auxiliary voltage supply for digital output
- Order number: 71135638 Kit, extension module 4AO
- 4 x analog output 0/4 to 20 mA
- Order number: 71135633 Other accessories Cables Memosens data cable CYK10
- For digital sensors with Memosens technology
- Product Configurator on the product page: www.endress.com/cyk10 Technical Information TI00118C Storage options
- Industrial Flash Drive, 1 GB
- Order number: 71110815 CDC90 USB stick kit
- 64 GB
- Order No. 71518248 Cable glands Kit CM44x: gland M
- Set, 6 pieces
- Order number: 71101768 Kit CM44x: gland NPT
- Set, 6 pieces
- Order number: 71101770 Kit CM44x: gland G
- Set, 6 pieces
- Order number: 71101771 Kit CM44x: dummy plug for cable gland
- Set, 6 pieces
- Order number: 71104942 M12 built-in socket and cable junction with Velcro strip CM442/CM444/CM448/CSF48 kit: M12 built-in socket for digital sensors
- Pre-terminated
- Order number: 71107456 CM442/CM444/CM448/CSF48 kit: M12 built-in socket for Ethernet
- Only for devices with BASE-E module
- D-coded, pre-terminated
- Order number: 71140893 CDC90 Ethernet cable kit, M12-RJ45 90° For devices with BASE2-E module: Order number: 71518244 Kit: external CDI socket, complete
- Retrofit kit for CDI interface, with terminated connecting cables
- Order number: 51517507 Cable junction with Velcro strip
- 4 pieces, for sensor cable
- Order number: 71092051 Graphic display
- For installation in the control cabinet door or panel
- Order number: 71185295
30 Endress+Hauser
- Portable, for commissioning
- Order number: 71185296 Buffer solutions High-quality buffer solutions from Endress+Hauser - CPY20 The secondary buffer solutions have been referenced to primary reference material of the PTB (German Federal Physico-technical Institute) or to standard reference material of NIST (National Institute of Standards and Technology) according to DIN 19266 by a laboratory accredited by the DAkkS (German accreditation body) according to DIN 17025. Product Configurator on the product page: www.endress.com/cpy20 ORP buffer solution CPY3
- 220 mV, pH 7
- 468 mV, pH 0.1 Product Configurator on the product page: www.endress.com/cpy3