CAX100 PHILIPS
Document overview
- Manufacturer or author: Provided By www.digicamel.com(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 1
Technical content
Philips Competence Centre Plastics B.V. Optical Components specification sheet 190 -1 page 1/1 1997 -12-10 1999-07-13 author: G Verkade 5722 600 20173 N.V. PHILIPS' ELECTRONICS All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of the copyright owner. Alle rechten voorbehouden. Verveelvoudiging, geheel of gedeeltelijk is niet toegestaan dan met schriftelijke toestemming van de auteursrechthebbende. Datasheet Plastic Collimator Lens CAX100 These data concern a full plastic aspherical plano -convex lens. It is specified for use as a collimator in combination with a diode laser. It can be mounted by use of glue or spring -loaded. Mechanical lock - mounting is not advisable because of possible distortions. Parameters Wavelength Unit 670 nm Design conditions N.A. 0.20 -- Clear Aperture CA 4.1 mm Designed with laser cover glass ( BK7) on source side: Distance from source 0.55 mm Glass thickness 0.25 mm Optical parameters Focal Length 10.0 mm Back Focal Length BFL (incl BK7 -glass) mm Free Working Distance FWD 9.21 8.48 mm RMS mean on axis 35 mλ RMS max. (±3 σ) on axis 80 mλ Optical Tolerance 0.1 mm Field Radius 0.2 mm Mechanical parameters Mounting hole diameter Dmh ∅ 6.28 mm Other parameters: see drawing Environmental stability Storage Temperature -25 to 100 °C Operating Temperature -10 to 75 °C General Data: Transmission [%]: 90 Lens Material: Polycarbonate Specifications subject to change without notice. Zemax catalogue file available.