C5601 BELDEN
Document overview
- PDF pages: 2
Technical content
Page 1

Product: C5601
Teck90 1000V, 3+G C #4+8 Str BC, XLPE Ins M4, PVC Jkt, AIA Armor, Blk PVC Jkt, CSA HL SUN RES -40C
Product Description
Teck90 1000V, 3+G Conductor 4+8AWG (7x12) Bare Copper, XLPE Insulation M4 Color Code, PVC Inner Jacket, Aluminum Interlock Armor, Black PVC
Outer Jacket, CSA HL SUN RES -40C
Technical Specifications
Product Overview
Suitable Applications:
Power and Control Applications up to 600V
Construction Details
Conductor
| Element | No. of Elements | Size | Stranding | Material |
| Conductor(s) | 3 | 4 | 7x12 | BC - Bare Copper |
| Ground | 1 | 8 | 7x16 | BC - Bare Copper |
Insulation
| Material | Nom. Thickness | Nom. Insulation Diameter | Color Code |
| XLP, XLPO, XLPE (Thermoset) | 0.061 in (1.5 mm) | 0.347 in (8.81 mm) | Black, Red, Blue |
Inner Jacket
| Material | Nom. Thickness | Nom. Diameter |
| PVC - Polyvinyl Chloride | 0.083 in (2.1 mm) | 0.840 in (21.3 mm) |
Armor
| Armor Type & Material | Diameter Over Armor |
|---|---|
| AIA - Aluminum Interlock Armor | 1.174 in (29.82 mm) |
Outer Jacket
| Material | Nom. Thickness | Nom. Diameter | Ripcord |
| PVC - Polyvinyl Chloride | 0.048 in (1.2 mm) | 1.270 in (32.26 mm) | Yes |
Electrical Characteristics
Electricals
| Element | Nom. Conductor DCR | Max. Current |
|---|---|---|
| Conductor(s) | 0.26 Ohm/1000ft | 95 Amps per Conductor at 30ºC |
| Ground | 0.654 Ohm/1000ft (2.15 Ohm/km) |
Voltage
Voltage Rating
1000 V (TECK 90)
Mechanical Characteristics
Temperature
UL Temperature Operating
Installation
Page 2
90°C
-40°C To +90°C -25°C To +90°C
Bend Radius
| Stationary Min. | Installation Min. | |
|---|---|---|
| 10.16 in (258.1 mm) | 10.16 in (258.1 mm) | |
| Max. Pull Tension: 2077.4 lbs (942.29 kg) | ||
| Bulk Cable Weight: 936 lbs/1000ft | ||
Standards and Compliance
Environmental Suitability:
Indoor, Outdoor, Sunlight Resistance, Burial
CEC / C(UL) Compliance:
TECK 90, HL
European Directive Compliance: EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC Compliance:
China RoHS II (GB/T 26572-2011)
History
Update and Revision:
Revision Number: 0.196 Revision Date: 05-31-2024
Part Numbers
Variants
Item # Putup Type
C5601 0101640 Reel
C5601 0102000 Reel
C5601 0103000 Reel
C5601 0103280 Reel
C5601 0106000 Reel
© 2024 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product
Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product.