BYV12 VISHAY

Document overview

  • Manufacturer or author: Provided By www.digicamel.com(free datasheet download site)
  • PDF pages: 4

Technical content

Features

/C0068Glass passivated junction /C0068Hermetically sealed package /C0068Soft recovery characteristic /C0068Low reverse current

Applications

Fast rectifier and switch for example for TV–line output circuits and switch mode power supply 94 9539 Absolute Maximum Ratings Tj = 25/C0095C Parameter Test Conditions Type Symbol Value Unit Reverse voltage BYV12 VR =VRRM 100 Vg =Repetitive peak reverse voltage BYV13 VR =VRRM 400 V BYV14 VR =VRRM 600 V BYV15 VR =VRRM 800 V BYV16 VR =VRRM 1000 V Peak forward surge current tp=10ms, half sinewave IFSM 40 A Repetitive peak forward current IFRM 9 A Average forward current ϕ=180/C0176, Tamb =25/C0176C IFAV 1.5 A Junction and storage temperature range Tj=Tstg –65...+175 /C0176C Maximum Thermal Resistance Tj = 25/C0095C Parameter Test Conditions Symbol Value Unit Junction ambient l=10mm, TL=constant R thJA 45 K/W on PC board with spacing 25mm R thJA 100 K/W

Electrical Characteristics

Tj = 25/C0095C Parameter Test Conditions Type Symbol Min Typ Max Unit Forward voltage IF=1A VF 1.5 V Reverse current VR =VRRM IR 1 5 /C0109A VR =VRRM , Tj=150/C0176C IR 60 150 /C0109A Reverse recovery time IF=0.5A, IR =1A, iR =0.25A trr 300 ns Reverse recovery chargeIF=1A, di/dt=5A//C0109s Q rr 200 nC

BYV12...BYV16 Vishay Telefunken www.vishay.de • FaxBack +1-408-970-5600 Rev. 2, 24-Jun-984 (4) Document Number 86039 Ozone Depleting Substances Policy Statement It is the policy of Vishay Semiconductor GmbH to 1. Meet all present and future national and international statutory requirements. 2. Regularly and continuously improve the performance of our products, processes, distribution and operating systems with respect to their impact on the health and safety of our employees and the public, as well as their impact on the environment. It is particular concern to control or eliminate releases of those substances into the atmosphere which are known as ozone depleting substances (ODSs). The Montreal Protocol (1987) and its London Amendments (1990) intend to severely restrict the use of ODSs and forbid their use within the next ten years. Various national and international initiatives are pressing for an earlier ban on these substances. Vishay Semiconductor GmbH has been able to use its policy of continuous improvements to eliminate the use of ODSs listed in the following documents. 1. Annex A, B and list of transitional substances of the Montreal Protocol and the London Amendments respectively 2. Class I and II ozone depleting substances in the Clean Air Act Amendments of 1990 by the Environmental Protection Agency (EPA) in the USA 3. Council Decision 88/540/EEC and 91/690/EEC Annex A, B and C (transitional substances) respectively. Vishay Semiconductor GmbH can certify that our semiconductors are not manufactured with ozone depleting substances and do not contain such substances. We reserve the right to make changes to improve technical design and may do so without further notice. Parameters can vary in different applications. All operating parameters must be validated for each customer application by the customer. Should the buyer use Vishay-Telefunken products for any unintended or unauthorized application, the buyer shall indemnify Vishay-Telefunken against all claims, costs, damages, and expenses, arising out of, directly or indirectly, any claim of personal damage, injury or death associated with such unintended or unauthorized use. Vishay Semiconductor GmbH, P.O.B. 3535, D-74025 Heilbronn, Germany Telephone: 49 (0)7131 67 2831, Fax number: 49 (0)7131 67 2423