BMXDRC0805 SCHNEIDER

Document overview

  • PDF pages: 5

Technical content

Page 1

Specifications

discrete module X80 - 8 NO/NC

PDF page 1 diagram

Type C - Isolated relays - 125 V

DC/250 V AC

BMXDRC0805

Main

Modicon X80

Range of product

Relay discrete output module

Product or component type

8 conforming to EN/IEC 61131-2

Discrete output number

Positive or negative

Discrete output logic

5...125 V 5...150 V DC

Discrete output voltage

24...240 V 19...264 V AC

Complementary

40 ways terminal block

Electrical connection

50/60 Hz

Network frequency

47…63 Hz

Network frequency limits

5...150 V

Sensor power supply

19...264 V

4 A 40 °C

[Ith] conventional free air

3 A 50 °C

thermal current

2 A 60 °C

10 MOhm 500 V DC

Insulation resistance

3.6 W

Power dissipation in W

<= 10 ms activation

Response time on output

<= 13 ms deactivation

40 mA at 3.3 V DC

Typical current consumption

101 mA at 24 V DC

2683411 H

MTBF reliability

External short-circuit protection

Protection type

External overload protection External overvoltage protection, inductive AC network External overvoltage protection, inductive DC network

Use 1 fast blow fuse per channel or group of channel

Output overload protection

Use discharge diode on each output DC

Output overvoltage protection

Use RC circuit on each output AC Use ZNO surge limiter on each output AC

Use 1 fast blow fuse per channel or group of channel

Output short-circuit protection

10 mA 5 V DC

Minimum switching current

AC-12: 200000 cycles at 48 VA 24 V at 0…60 °C

Electrical durability

AC-12: 300000 cycles at 48 VA 48 V at 0…60 °C AC-12: 150000 cycles at 96 VA 48 V at 0…60 °C AC-12: 300000 cycles at 110 VA 100...120 V at 0…60 °C AC-12: 150000 cycles at 220 VA 100...120 V at 0…60 °C

PDF page 1 diagram

Page 2

AC-12: 300000 cycles at 220 VA 200...250 V at 0…60 °C AC-12: 150000 cycles at 500 VA 200...250 V at 0…60 °C AC-15: 700000 cycles at 10 VA 24 V at 0…60 °C (load factor 0.4) AC-15: 500000 cycles at 24 VA 24 V at 0…60 °C (load factor 0.4) AC-15: 200000 cycles at 48 VA 24 V at 0…60 °C (load factor 0.4) AC-15: 700000 cycles at 10 VA 48 V at 0…60 °C (load factor 0.4) AC-15: 500000 cycles at 24 VA 48 V at 0…60 °C (load factor 0.4) AC-15: 300000 cycles at 48 VA 48 V at 0…60 °C (load factor 0.4) AC-15: 100000 cycles at 96 VA 48 V at 0…60 °C (load factor 0.4) AC-15: 1000000 cycles at 10 VA 100...120 V at 0…60 °C (load factor 0.4) AC-15: 300000 cycles at 50 VA 100...120 V at 0…60 °C (load factor 0.4)

AC-15: 200000 cycles at 110 VA 100...120 V at 0…60 °C (load factor 0.4) AC-15: 70000 cycles at 220 VA 100...120 V at 0…60 °C (load factor 0.4) AC-15: 1000000 cycles at 10 VA 200...250 V at 0…60 °C (load factor 0.4) AC-15: 500000 cycles at 50 VA 200...250 V at 0…60 °C (load factor 0.4) AC-15: 200000 cycles at 110 VA 200...250 V at 0…60 °C (load factor 0.4) AC-15: 150000 cycles at 220 VA 200...250 V at 0…60 °C (load factor 0.4) DC-12: 200000 cycles at 24 W 24 V at 0…60 °C DC-12: 150000 cycles at 48 W 24 V at 0…60 °C DC-12: 150000 cycles at 40 W 48...60 V at 0…60 °C DC-12: 100000 cycles at 45 W 100...125 V at 0…60 °C DC-13: 100000 cycles at 10 W 24 V at 0…60 °C

DC-13: 60000 cycles at 24 W 24 V at 0…60 °C DC-13: 40000 cycles at 48 W 24 V at 0…60 °C DC-13: 40000 cycles at 40 W 48...60 V at 0…60 °C DC-13: 100000 cycles at 15 W 100...125 V at 0…60 °C

1 LED (green)RUN

Status LED

1 LED per channel (green)channel diagnostic 1 LED (red)ERR 1 LED (red)I/O

0.189 kg

Net weight

Environment

IP20

IP degree of protection

1780 V AC at 50/60 Hz 1 min

Dielectric strength

3 gn

Vibration resistance

30 gn

Shock resistance

0…95 % at 0…60 °C without condensation

Relative humidity

0...2000 m

Operating altitude

2000...5000 m with derating factor

Packing Units

PCE

Unit Type of Package 1

1

Number of Units in Package 1

332.0 g

Package 1 Weight

5.5 cm

Package 1 Height

18 cm

Package 1 width

26 cm

Package 1 Length

S03

Unit Type of Package 2

8

Number of Units in Package 2

2.656 kg

Package 2 Weight

30 cm

Package 2 Height

30 cm

Package 2 width

40 cm

Package 2 Length

Offer Sustainability

Green Premium product

Sustainable offer status

REACh Regulation

REACh Declaration

Pro-active compliance (Product out of EU RoHS legal scope)

EU RoHS Directive

EU RoHS Declaration

Page 3

Yes

Mercury free

RoHS exemption information

Yes

China RoHS Regulation

China RoHS declaration

Environmental Disclosure

Product Environmental Profile

Circularity Profile

End of Life Information

The product must be disposed on European Union markets following specific waste collection and

WEEE

never end up in rubbish bins

WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is

California proposition 65

known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Page 4

BMXDRC0805

Dimensions Drawings

Dimensions

PDF page 4 diagram

(1) Front view (2) Right view (3) Top view

Page 5

BMXDRC0805

Connections and Schema

Connecting the Module

Output Circuit Diagram

PDF page 5 diagram

(1) Module (2) Output (3) Command (4) Pre-actuator (5) Power supply NO : Normally open output NC : Normally closed output

Module Connection

PDF page 5 diagram

(1) Pre-actuator (2) Power supply : 24...125 Vdc or 24...240 Vac (3) Fuse : Use appropriate fast-blow fuse for each relay (4) We recommend installing this type of protection on the terminals of each pre-actuator N/C : Not connected